Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Data Brief ; 53: 110145, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38370918

RESUMO

The MONITOOL project (2017-2023) was carried out to describe the relationships between total dissolved and labile metal concentrations measured in spot water samples and in concurrently deployed Diffusive Gradients in Thin-films (DGTs) passive samplers, respectively. The ultimate aim was to adapt existing marine metal Environmental Quality Standards (EQS marine water) for DGTs, enabling their use in the context of the European Directives (the Water Framework Directive (WFD) and the Marine Strategy Framework Directive (MSFD)). Time-integrated metal concentrations provided by DGTs, representing several days, are an advantage compared to conventional spot sampling, especially in highly dynamic systems, such as transitional waters. Hence, the MONITOOL project aimed to provide a robust database of dissolved and labile metal concentrations in transitional and coastal waters, based upon co-deployments of DGTs and collection of spot water samples at several sampling sites (England, France, Ireland, Italy, Northern Ireland, Portugal, Scotland and Spain), followed subsequently by DGT and water metal analysis. Samplings were carried out in 2018 and 2022, following agreed protocols developed in the framework of the project. The MONITOOL dataset includes metal concentrations from DGTs, measured with Inductively Coupled Plasma Mass Spectrometry (ICP-MS: Cd, Co, Cu, Fe, Mn, Ni, Pb, Zn) and in concurrently collected spot water samples by ICP-MS (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) and Anodic/Cathodic Stripping Voltammetry (ASV/CSV: Cd, Pb, Ni). Moreover, data on seawater physical-chemical parameters (salinity, temperature, dissolved oxygen, pH, turbidity, total suspended solids, dissolved organic carbon, and total organic carbon) is provided. This database presents the results obtained using, concurrently, different forms of sampling and analytical techniques, enabling the comparison of the results obtained by these strategies and allowing the adaptation of EQS in marine water (EQS marine water) to DGTs (EQS DGT), in the context of the WFD. Moreover, due to the large number of sampling sites, it could also be used for other types of research, such as those dealing with metal speciation or the determination of baseline levels.

2.
Blood Coagul Fibrinolysis ; 35(1): 14-22, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38051662

RESUMO

Laboratory compliance implies to correlate instruments for coagulation parameter with a wide range of measure using patient samples or commercialized sets of frozen plasmas. The aim of this study was to evaluate the intra, inter-reproducibility and long-term stability of ExpertCor Routine (ECR) plasma sets (Stago) on different parameters. The study was realized in two laboratories on four different instruments. Inter-site and intra-site correlation of ECR sets for PT, aPTT, Fibrinogen, INR, factor V (FV) UFH and LMWH anti-Xa and intra-reproducibility of DDimer (DDI), factor VIII (FVIII:C) and antithrombin (AT) assays were tested. To evaluate ECR long-term stability, samples were tested until 180 after delivery in one laboratory. Intra-site evaluation correlation coefficients is around 1. All predefined criteria to fulfil good comparability between inter-site instruments are met with Passing slopes between 0.9 and 1.1 and intercepts ranging from -0.62 to 2.83%. Long-term stability evaluation does not show any deviation over 180 days for aPTT, fibrinogen, DDI, UFH, LMWH but a drift for FV with STA-NeoPTimal reagent. On contrary, AT and FVIII:C are not stable. PT in second has an excellent stability unlike PT in percentage. Our study validates the use of ECR sets for correlation between instruments and inter-sites agreement, as for parameters claimed on the products than for factor V and FVIII:C. The evaluation of stability confirming the possible extension of use for 180 days after delivery except for FVIII:C and AT. These plasmas sets are an excellent alternative to local plasma patient use to perform instrument comparison.


Assuntos
Fator V , Hemostáticos , Humanos , Heparina de Baixo Peso Molecular , Reprodutibilidade dos Testes , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Fibrinogênio
3.
Sci Total Environ ; 847: 157499, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-35870601

RESUMO

In order to move forward in the acceptance of a novel contaminant monitoring technique (Diffusive Gradients in Thin-films: DGT) for assessment of marine water bodies, sensu the WFD, an Inter-Laboratories Comparison (ILC) exercise (nine Europeans laboratories) was organized in the framework of the Interreg Atlantic Area MONITOOL project, which focused on the use of the DGT technique for the measurement of WFD priority metals (Cd, Ni and Pb). Reproducible results were obtained for each metal by several laboratories, supporting the assertion that DGT analysis can be performed satisfactorily by laboratories experienced in measuring metals at trace levels in marine environments, even if they have limited practice in DGT analysis. According to the Z-score analysis, among the 9 participating laboratories, 3 had 100 % of satisfactory results for Cd, Ni, and Pb, 3 had >80 % satisfactory results and 2 had about 60 % satisfactory results. This work highlights the need to clearly describe the DGT method in order to control sources of contamination during analytical steps, in particular the resin gel retrieval and the elution steps. Such international intercomparison exercise is an important step to develop the laboratory network involved in DGT analysis and contributes to the improvement of data quality.


Assuntos
Monitoramento Ambiental , Poluentes Químicos da Água , Cádmio/análise , Difusão , Monitoramento Ambiental/métodos , Humanos , Chumbo/análise , Água/análise , Poluentes Químicos da Água/análise
4.
Mar Pollut Bull ; 179: 113715, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35526381

RESUMO

This study investigates the relationships among Ni, Cd and Pb's different chemical forms determined by different methodologies in coastal and transitional waters across a broad geographical scale. Concentrations were measured in spot samples and through passive sampling (DGT). High variability of metal concentrations was found among sampling sites and methodologies due to natural water fluctuations rather than to a given metal or method. Total dissolved metal concentrations in spot samples were lower than the EQS-WFD values. The labile fractions of Cd and Pb, measured in spot samples by Anodic Stripping Voltammetry and by DGT-ICPMS, were highly correlated. Similar labilities were found for Cd, while for Pb, the ASV labile fraction was ≈50% lower. These results reflect the pool of mobile and labile species available towards each technique kinetic window, and they seem not to be affected by discrete sampling flaws.


Assuntos
Monitoramento Ambiental , Poluentes Químicos da Água , Cádmio/análise , Monitoramento Ambiental/métodos , Chumbo/análise , Poluentes Químicos da Água/análise
5.
MethodsX ; 8: 101462, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434867

RESUMO

This protocol was developed based on the knowledge acquired in the framework of the Interreg MONITOOL project (EAPA_565/2016) where extensive sampling campaigns were performed in transitional and coastal waters covering eight European countries. It provides detailed procedures and guidelines for the sampling of these waterbodies by concurrent collection of discrete water samples and the deployment of Diffusive Gradient in Thin-films (DGT) passive samplers for the measurement of trace metal concentrations. In order to facilitate the application of this protocol by end-users, it presents steps to follow in the laboratory prior to sampling campaigns, explains the procedures for field campaigns (including in situ measurement of supporting parameters) and subsequent sample processing in the laboratory in preparation for trace metal analyze by inductively coupled plasma-mass spectrometry (ICP-MS) and voltammetry. The protocol provides a systematic, coherent field sampling and sample preparation strategy that was developed in order to ensure comparability and reproducibility of the data obtained from each project Partner in different regions. • Standardization of the concurrent sampling of transitional and coastal waters by DGT passive samplers and spot sampling. • Robust procedures and tips based on existing international standards and comprehensive practical experience. • Links to demonstration videos produced within the MONITOOL project.

6.
Sci Total Environ ; 783: 147001, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-33872893

RESUMO

The current study evaluates the effect of seawater physico-chemical characteristics on the relationship between the concentration of metals measured by Diffusive Gradients in Thin films (DGT) passive samplers (i.e., DGT-labile concentration) and the concentrations measured in discrete water samples. Accordingly, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to measure the total dissolved metal concentrations in the discrete water samples and the labile metal concentrations obtained by DGT samplers; additionally, lead and cadmium conditional labile fractions were determined by Anodic Stripping Voltammetry (ASV) and total dissolved nickel was measured by Cathodic Stripping Voltammetry (CSV). It can be concluded that, in general, the median ratios of DGT/ICP and DGT/ASV(CSV) were lower than 1, except for Ni (median ratio close to 1) and Zn (higher than 1). This indicates the importance of speciation and time-integrated concentrations measured using passive sampling techniques, which is in line with the WFD suggestions for improving the chemical assessment of waterbodies. It is the variability in metal content in waters rather than environmental conditions to which the variability of the ratios can be attributed. The ratios were not significantly affected by the temperature, salinity, pH, oxygen, DOC or SPM, giving a great confidence for all the techniques used. Within a regulatory context such as the EU Water Framework Directive this is a great advantage, since the simplicity of not needing to use corrections to minimize the effects of environmental variables could help in implementing DGTs within monitoring networks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA