Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
2.
Am J Cardiol ; 217: 144-152, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38431052

RESUMO

Coronary angiography (CA) is poorly correlated with non-invasive myocardial stress imaging (NSI) and myocardial ischemia is often observed in patients with unobstructed coronary arteries. Moreover, the diagnostic performance of combined epicardial and microcirculatory angiography-derived physiological assessment and its correlation with NSI remains unknown. A total of 917 coronary vessels in 319 patients who underwent both CA and NSI were included in this multicenter observational retrospective analysis. Quantitative flow ratio (QFR) and angiography-derived index of microcirculatory resistance (IMRangio) analyses were performed to estimate coronary epicardial and microcirculatory function respectively. NSI demonstrated evidence of myocardial ischemia in 76% of the cases. IMRangio (36 [22 to 50] vs 29 [21 to 41], p <0.001) was significantly higher and QFR (0.92 [0.78 to 0.99] vs 0.97 [0.91 to 0.99], p <0.001) was significantly lower in vessels subtending ischemic territories. Overall, the diagnostic accuracy of QFR was moderate (area under the curve of receiver operating characteristic [AUCROC] 0.632 [95% confidence interval [CI] 0.589 to 0.674], p <0.0001) but it was higher in patients with normal microcirculatory function (AUCROC = 0.726 [95% CI 0.669 to 0.784], p <0.0001, p Value for AUCROC comparison = 0.009). Combined QFR/IMRangio assessment provided incremental diagnostic performance compared with the evaluation of epicardial or microcirculatory districts in isolation (p Value for AUC comparison <0.0001) and it was able to identify the predominant mechanism of myocardial ischemia in 77% of the patients with positive NSI. Our study suggests the value of a combined angiography-derived assessment of epicardial and microvascular function for the definition of the predominant mechanism of myocardial ischemia in patients with suspected coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico , Estudos Retrospectivos , Microcirculação , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Isquemia Miocárdica/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
3.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
4.
Circ Cardiovasc Interv ; 17(3): e013556, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38375667

RESUMO

BACKGROUND: Patients with ST-segment-elevation myocardial infarction but no coronary microvascular injury are at low risk of early cardiovascular complications (ECC). We aim to assess whether nonhyperemic angiography-derived index of microcirculatory resistance (NH-IMRangio) could be a user-friendly tool to identify patients at low risk of ECC, potentially candidates for expedited care pathway and early hospital discharge. METHODS: Retrospective analysis of 2 independent, international, prospective, observational cohorts included 568 patients with ST-segment-elevation myocardial infarction. NH-IMRangio was calculated based on standard coronary angiographic views with 3-dimensional-modeling and computational analysis of the coronary flow. RESULTS: Overall, ECC (a composite of cardiovascular death, cardiogenic shock, acute heart failure, life-threatening arrhythmias, resuscitated cardiac arrest, left ventricular thrombus, post-ST-segment-elevation myocardial infarction mechanical complications, and rehospitalization for acute heart failure or acute myocardial infarction at 30 days follow-up), occurred in 54 (9.3%) patients. NH-IMRangio was significantly correlated with pressure/thermodilution-based index of microcirculatory resistance (r=0.607; P<0.0001) and demonstrated good accuracy in predicting ECC (area under the curve, 0.766 [95% CI, 0.706-0.827]; P<0.0001). Importantly, ECC occurred more frequently in patients with NH-IMRangio ≥40 units (18.1% versus 1.4%; P<0.0001). At multivariable analysis, NH-IMRangio provided incremental prognostic value to conventional clinical, angiographic, and echocardiographic features (adjusted-odds ratio, 14.861 [95% CI, 5.177-42.661]; P<0.0001). NH-IMRangio<40 units showed an excellent negative predictive value (98.6%) in ruling out ECC. Discharging patients with NH-IMRangio<40 units at 48 hours after admission would reduce the total in-hospital stay by 943 days (median 2 [1-4] days per patient). CONCLUSIONS: NH-IMRangio is a valuable risk-stratification tool in patients with ST-segment-elevation myocardial infarction. NH-IMRangio guided strategies to early discharge may contribute to safely shorten hospital stay, optimizing resources utilization.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Microcirculação , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Infarto do Miocárdio/etiologia , Alta do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Resultado do Tratamento , Estudos Observacionais como Assunto
5.
Heart ; 110(8): 603-612, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38040448

RESUMO

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Microcirculação , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
6.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982161

RESUMO

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA