Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Childs Nerv Syst ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958731

RESUMO

PURPOSE: Filum terminale lipoma (FTL) causes spinal-cord tethering and is associated with tethered-cord syndrome, which is treated by dissection of the entrapment. The conventional treatment for FTL involves dissection of the spinal cord through a laminotomy open approach (LOA). However, in recent years, the interlaminar approach (ILA) has gained popularity as a minimally invasive surgery. This study compares the effectiveness of the minimally invasive ILA with the conventional LOA in treating FTL. METHODS: We retrospectively evaluated data on the ILA and LOA for FTL at our center. In total, 103 participants were enrolled, including 55 in the ILA group and 48 in the LOA group. RESULTS: The ILA required significantly less surgical time and resulted in less blood loss. The improvement rate of symptoms in symptomatic patients was 84%, and for urinary symptoms and abnormal urodynamic study findings, it was 77%. The postoperative maintenance rate for asymptomatic patients was 100%. Postoperative complications of ILA included delayed wound healing in two patients (3.6%). CONCLUSION: Compared with LOA, ILA offers advantages in terms of shorter operative time and less blood loss, with no significant difference in long-term symptom-improvement rates between the groups.

2.
J Arrhythm ; 32(1): 36-41, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26949429

RESUMO

BACKGROUND: Even with the use of a reduced energy setting (20-25 W), excessive transmural injury (ETI) following catheter ablation of atrial fibrillation (AF) is reported to develop in 10% of patients. However, the incidence of ETI depends on the pulmonary vein isolation (PVI) method and its esophageal temperature monitor setting. Data comparing the incidence of ETI following AF ablation with and without esophageal temperature monitoring (ETM) are still lacking. METHODS: This study was comprised of 160 patients with AF (54% paroxysmal, mean: 24.0±2.9 kg/m(2)). Eighty patients underwent ablation accompanied by ETM. The primary endpoint was defined as the occurrence of ETI assessed by endoscopy within 5 d after the AF ablation. The secondary endpoint was defined as AF recurrence after a single procedure. If the esophageal temperature probe registered >39 °C, the radiofrequency (RF) application was stopped immediately. RF applications could be performed in a point-by-point manner for a maximum of 20 s and 20 W. ETI was defined as any injury that resulted from AF ablation, including esophageal injury or periesophageal nerve injury (peri-ENI). RESULTS: The incidence of esophageal injury was significantly lower in patients whose AF ablation included ETM compared with patients without ETM (0 [0%] vs. 6 [7.5%], p=0.028), but not the incidence of peri-ENI (2 [2.5%] vs. 3 [3.8%], p=1.0). AF recurrence 12 months after the procedure was similar between the groups (20 [25%] in the ETM group vs. 19 [24%] in the non-ETM group, p=1.00). CONCLUSIONS: Catheter ablation using ETM may reduce the incidence of esophageal injury without increasing the incidence of AF recurrence but not the incidence of peri-ENI.

3.
J Magn Reson Imaging ; 43(2): 495-503, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26149175

RESUMO

BACKGROUND: To investigate the feasibility of substituting non-contrast-enhanced MR (non-CE-MR) imaging with a two-dimensional (2D) balanced steady-state free precession (b-SSFP) sequence for contrast-enhanced computed tomography (CE-CT) for atrial fibrillation (AF) ablation. METHODS: Fifty-four patients that underwent AF ablation under the guidance of a 3D electro-anatomical mapping system with CE-CT (n = 27) or non-CE-MR images (n = 27) were studied. Procedural results were compared between the two groups. Furthermore, in 22 patients who underwent both CE-CT and non-CE-MRI, two cardiologists independently scored the multiplanar reformatted images on a scale of 1 to 4 (from 1, poor, to 4, excellent). RESULTS: The image score was nearly 0.5 point higher with the CE-CT method. However, the procedural results such as the surface registration error (1.0 [0.8-1.6] mm versus 1.0 [0.8-1.35] mm, P = 0.88) and procedure time (185 [159-199] min versus 185 [142-221] min, P = 0.86) did not significantly differ between the CE-CT and non-CE-MR groups. CONCLUSION: The non-CE-MR method with a 2D-b-SSFP sequence can give us adequate information on AF ablation without any radiation exposure or contrast medium usage


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Veias Pulmonares/anatomia & histologia , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter , Estudos de Viabilidade , Feminino , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Reprodutibilidade dos Testes
4.
J Arrhythm ; 31(1): 12-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26336517

RESUMO

BACKGROUND: Esophageal injury following catheter ablation of atrial fibrillation (AF) is reported to occur in 35% of patients. Even with a low energy setting (20-25 W), lesions develop in 10% of patients. Body mass index (BMI) has been reported to be a predictor of esophageal injury, indicating that patients with a low BMI (<24.9 kg/m(2)) are at a higher risk. We hypothesized that catheter ablation with a lower energy setting of 20 W controlled by esophageal temperature monitoring (ETM) at 39 °C could prevent esophageal injury even in patients with a BMI <24.9 kg/m(2). METHODS: Twenty patients with AF were included (age, 63±8 years; BMI, 22.9±1.3 kg/m(2), left atrium diameter, 44±11 mm). If the esophageal temperature probe registered a temperature of >39 °C, radiofrequency (RF) application was stopped immediately. RF application could be performed in a "point by point" manner for a maximum of 20 s. Endoscopy was performed 1-5 days after ablation. RESULTS: Esophageal mucosal injury was not observed in any patient in the study. CONCLUSIONS: Catheter ablation using ETM reduced the incidence of esophageal injuries, even in patients with a low BMI.

5.
J Arrhythm ; 31(2): 71-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26336534

RESUMO

BACKGROUND: Atrial tissue fibrosis has previously been identified using delayed-enhancement MRI (DE-MRI) in patients with atrial fibrillation (AF). Although the clinical importance of DE-MRI is well recognized, the visualization of atrial fibrosis and radiofrequency (RF) lesions has still not been achieved in Japan, primarily because of the differences in contrast agents, volume-rendering tools, and technical experience. The objective of this study was to visualize RF lesions by using commercially available tools. METHODS: DE-MRI was performed in 15 patients who had undergone AF ablation (age, 59±4 years, left atrium diameter, 40±2 mm). Specific parameters for MR scanning obtained from previous reports were modified. RESULTS: Of the 15 images, the images of three patients were uninterpretable owing to low image quality. RF lesions could be visualized in 8 (67%) of the 12 patients. CONCLUSIONS: In the current study, we successfully demonstrated that RF lesions could be visualized in Japanese patients using DE-MRI, although only commercially available tools were used.

6.
J Arrhythm ; 31(3): 152-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26336549

RESUMO

BACKGROUND: The radiofrequency (RF) lesions for atrial fibrillation (AF) ablation can be visualized by delayed enhancement magnetic resonance imaging (DE-MRI). However, the quality of anatomical information provided by DE-MRI is not adequate due to its spatial resolution. In contrast, magnetic resonance angiography (MRA) provides similar information regarding the left atrium (LA) and pulmonary veins (PVs) as computed tomography angiography. We hypothesized that DE-MRI fused with MRA will compensate for the inadequate image quality provided by DE-MRI. METHODS: DE-MRI and MRA were performed in 18 patients who underwent AF ablation (age, 60±9 years; LA diameter, 42±6 mm). Two observers independently assessed the DE-MRI and DE-MRI fused with MRA for visualization of the RF lesion (score 0-2; where 0: not visualized and 2: excellent in all 14 segments of the circular RF lesion). RESULTS: DE-MRI fused with MRA was successfully performed in all patients. The image quality score was significantly higher in DE-MRI fused with MRA compared to DE-MRI alone (observer 1: 22 (18, 25) vs 28 (28, 28), p<0.001; observer 2: 24 (23, 25) vs 28 (28, 28), p<0.001). CONCLUSIONS: DE-MRI fused with MRA was superior to DE-MRI for visualization of the RF lesion owing to the precise information on LA and PV anatomy provided by DE-MRI.

7.
J Arrhythm ; 31(4): 189-95, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26336558

RESUMO

BACKGROUND: Usually, the pulmonary venous and left atrial (PV-LA) anatomy is assessed with contrast-enhanced computed tomographic imaging for catheter ablation of atrial fibrillation (AF). A non-contrast-enhanced magnetic resonance (MR) imaging method has not been established. Three-dimensional balanced steady-state free precession (3D b-SSFP) sequences cannot visualize the PV-LA anatomy simultaneously because of the signal intensity defect of pulmonary veins. We compared two-dimensional (2D) b-SSFP sequences with 3D b-SSFP sequences in depicting the PV-LA anatomy with non-contrast-enhanced MR imaging for AF ablation. METHODS: Eleven healthy volunteers underwent non-contrast-enhanced MR imaging with 3D b-SSFP and 2D b-SSFP sequences. The MR images were reconstructed on the 3D PV-LA surface image. Two experienced radiological technicians independently scored the multiplanar reformatted (MPR) images on a scale of 1-4 (from 1, not visualized, to 4, excellent definition). The overall score was a sum of 5 segments (LA and 4 PVs). RESULTS: In the 2D b-SSFP method, MR imaging was successfully performed, and the 3D PV-LA surface image was precisely reconstructed in all healthy volunteers. The image score was significantly higher in the 2D b-SSFP method compared to the 3D b-SSFP method (19 [19; 20] vs. 12 [11; 15], p=0.004, for both observers). No PV signal intensity defects occurred in the 2D b-SSFP method. CONCLUSIONS: The 2D b-SSFP sequence was more useful than the 3D b-SSFP sequence in adequately depicting the PV-LA anatomy.

8.
Circ J ; 79(8): 1727-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25993904

RESUMO

BACKGROUND: The incidence of hematoma formation following implantation of a cardiovascular implantable electronic device (CIED) is estimated to be 5% even if a pressure dressing is applied. It is unclear whether a pressure dressing can really compress the pocket in different positions. Furthermore, the adhesive tape for fixing pressure dressings can tear the skin. We developed a new compression tool for preventing hematomas and skin erosions. METHODS AND RESULTS: We divided 46 consecutive patients receiving anticoagulation therapy who underwent CIED implantation into 2 groups (Group I: conventional pressure dressing, Group II: new compression tool). The pressure on the pocket was measured in both the supine and standing positions. The incidence of hematomas was compared between the 2 groups. The pressure differed between the supine and standing positions in Group I, but not in Group II (Group I: 14.8±7.1 mmHg vs. 11.3±9.9 mmHg, P=0.013; Group II: 13.5±2.8 mmHg vs. 13.5±3.5 mmHg, P=0.99). The incidence of hematomas and skin erosions was documented in 2 (8.7%) and 3 (13%) Group I patients, respectively. No complications were documented in Group II. CONCLUSIONS: The new compression tool can provide adequate continuous pressure on the pocket, regardless of body position. This device may reduce the incidence of hematomas and skin erosions after CIED implantation.


Assuntos
Bandagens Compressivas , Desfibriladores Implantáveis , Hematoma/prevenção & controle , Dermatopatias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
9.
Environ Monit Assess ; 187(1): 4166, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25467412

RESUMO

An emerging alternative to the commonly used analytical methods for asbestos analysis is fluorescence microscopy (FM), which relies on highly specific asbestos-binding probes to distinguish asbestos from interfering non-asbestos fibers. However, all types of microscopic asbestos analysis require laborious examination of large number of fields of view and are prone to subjective errors and large variability between asbestos counts by different analysts and laboratories. A possible solution to these problems is automated counting of asbestos fibers by image analysis software, which would lower the cost and increase the reliability of asbestos testing. This study seeks to develop a fiber recognition and counting software for FM-based asbestos analysis. We discuss the main features of the developed software and the results of its testing. Software testing showed good correlation between automated and manual counts for the samples with medium and high fiber concentrations. At low fiber concentrations, the automated counts were less accurate, leading us to implement correction mode for automated counts. While the full automation of asbestos analysis would require further improvements in accuracy of fiber identification, the developed software could already assist professional asbestos analysts and record detailed fiber dimensions for the use in epidemiological research.


Assuntos
Amianto/análise , Monitoramento Ambiental/métodos , Substâncias Perigosas/análise , Microscopia de Fluorescência , Software , Laboratórios , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA