Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomech Model Mechanobiol ; 23(1): 61-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37566172

RESUMO

Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.


Assuntos
Dissecção Aórtica , Fenômenos Biológicos , Trombose , Humanos , Hemodinâmica , Estresse Mecânico , Modelos Cardiovasculares
2.
Sci Rep ; 13(1): 12123, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495611

RESUMO

Stent graft-induced new entry tear (SINE) is a serious complication in aortic dissection patients caused by the stent-graft itself after thoracic endovascular aortic repair (TEVAR). The stability of SINE is a key indicator for the need and timing of reinterventions. This study aimed to understand the role of hemodynamics in SINE stability by means of computational fluid dynamics (CFD) analysis based on patient-specific anatomical information. Four patients treated with TEVAR who developed a distal SINE (dSINE) were included; two patients had a stable dSINE and two patients experienced expansion of the dSINE upon follow-up examinations. CFD simulations were performed on geometries reconstructed from computed tomography scans acquired upon early detection of dSINE in these patients. Computational results showed that stable dSINEs presented larger regions with low time-averaged wall shear stress (TAWSS) and high relative residence time (RRT), and partial thrombosis was observed at subsequent follow-ups. Furthermore, significant systolic antegrade flow was observed in the unstable dSINE which also had a larger retrograde flow fraction (RFF) on the SINE plane. In conclusion, this pilot study suggested that high RRT and low TAWSS may indicate stable dSINE by promoting thrombosis, whereas larger RFF and antegrade flows inside dSINE might be associated with its expansion.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose , Humanos , Stents/efeitos adversos , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Projetos Piloto , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Fatores de Risco , Prótese Vascular/efeitos adversos , Trombose/etiologia , Hemodinâmica , Estudos Retrospectivos
3.
Comput Methods Programs Biomed ; 233: 107468, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36921465

RESUMO

BACKGROUND AND OBJECTIVE: Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoratic aortic aneurysms (ATAA). To accurately reproduce in vivo hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow boundary conditions (BCs). However, the limited availability of in vivo velocity measurements, still makes researchers resort to idealized BCs. The aim of this study was to generate and thoroughly characterize a large dataset of synthetic 4D aortic velocity profiles sampled on a 2D cross-section along the ascending aorta with features similar to clinical cohorts of patients with ATAA. METHODS: Time-resolved 3D phase contrast magnetic resonance (4D flow MRI) scans of 30 subjects with ATAA were processed through in-house code to extract anatomically consistent cross-sectional planes along the ascending aorta, ensuring spatial alignment among all planes and interpolating all velocity fields to a reference configuration. Velocity profiles of the clinical cohort were extensively characterized by computing flow morphology descriptors of both spatial and temporal features. By exploiting principal component analysis (PCA), a statistical shape model (SSM) of 4D aortic velocity profiles was built and a dataset of 437 synthetic cases with realistic properties was generated. RESULTS: Comparison between clinical and synthetic datasets showed that the synthetic data presented similar characteristics as the clinical population in terms of key morphological parameters. The average velocity profile qualitatively resembled a parabolic-shaped profile, but was quantitatively characterized by more complex flow patterns which an idealized profile would not replicate. Statistically significant correlations were found between PCA principal modes of variation and flow descriptors. CONCLUSIONS: We built a data-driven generative model of 4D aortic inlet velocity profiles, suitable to be used in computational studies of blood flow. The proposed software system also allows to map any of the generated velocity profiles to the inlet plane of any virtual subject given its coordinate set.


Assuntos
Aorta Torácica , Aneurisma Aórtico , Humanos , Aorta Torácica/fisiologia , Estudos Transversais , Aorta/fisiologia , Imageamento por Ressonância Magnética , Hemodinâmica/fisiologia , Aneurisma Aórtico/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo
4.
Front Bioeng Biotechnol ; 10: 1033450, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36394040

RESUMO

Background: Type B aortic dissection (TBAD) is a dangerous pathological condition with a high mortality rate. TBAD is initiated by an intimal tear that allows blood to flow between the aortic wall layers, causing them to separate. As a result, alongside the original aorta (true lumen), a false lumen (FL) develops. TBAD compromises the whole cardiovascular system, in the worst case resulting in complete aortic rupture. Clinical studies have shown that dilation and rupture of the FL are related to the failure of the FL to thrombose. Complete FL thrombosis has been found to improve the clinical outcomes of patients with chronic TBAD and is the desired outcome of any treatment. Partial FL thrombosis has been associated with late dissection-related deaths and the requirement for re-intervention, thus the level of FL thrombosis is dominant in classifying the risk of TBAD patients. Therefore, it is important to investigate and understand under which conditions complete thrombosis of the FL occurs. Method: Local FL hemodynamics play an essential role in thrombus formation and growth. In this study, we developed a simplified phenomenological model to predict FL thrombosis in TBAD under physiological flow conditions. Based on an existing shear-driven thrombosis model, a comprehensive model reduction study was performed to improve computational efficiency. The reduced model has been implemented in Ansys CFX and applied to a TBAD case following thoracic endovascular aortic repair (TEVAR) to test the model. Predicted thrombus formation based on post-TEVAR geometry at 1-month was compared to actual thrombus formation observed on a 3-year follow-up CT scan. Results: The predicted FL status is in excellent agreement with the 3-year follow-up scan, both in terms of thrombus location and total volume, thus validating the new model. The computational cost of the new model is significantly lower than the previous thrombus model, with an approximate 65% reduction in computational time. Such improvement means the new model is a significant step towards clinical applicability. Conclusion: The thrombosis model developed in this study is accurate and efficient at predicting FL thrombosis based on patient-specific data, and may assist clinicians in choosing individualized treatments in the future.

5.
J Endovasc Ther ; : 15266028221111295, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35852439

RESUMO

PURPOSE: False lumen (FL) expansion often occurs in type B aortic dissection (TBAD) and has been associated with the presence of re-entry tears. This longitudinal study aims to elucidate the role of re-entry tears in the progression of TBAD using a controlled swine model, by assessing aortic hemodynamics through combined imaging and computational modeling. MATERIALS AND METHODS: A TBAD swine model with a primary entry tear at 7 cm distal to the left subclavian artery was created in a previous study. In the current study, reintervention was carried out in this swine model to induce 2 additional re-entry tears of approximately 5 mm in diameter. Computed tomography (CT) and 4-dimensional (4D) flow magnetic resonance imaging (MRI) scans were taken at multiple follow-ups before and after reintervention. Changes in aortic volume were measured on CT scans, and hemodynamic parameters were evaluated based on dynamic data acquired with 4D-flow MRI and computational fluid dynamics simulations incorporating all available in vivo data. RESULTS: Morphological analysis showed FL growth of 20% following the initial TBAD-growth stabilized after the creation of additional tears and eventually FL volume reduced by 6%. Increasing the number of re-entry tears from 1 to 2 caused flow redistribution, with the percentage of true lumen (TL) flow increasing from 56% to 78%; altered local velocities; reduced wall shear stress surrounding the tears; and led to a reduction in FL pressure and pressure difference between the 2 lumina. CONCLUSION: This study combined extensive in vivo imaging data with sophisticated computational methods to show that additional re-entry tears can alter dissection hemodynamics through redistribution of flow between the TL and FL. This helps to reduce FL pressure, which could potentially stabilize aortic growth and lead to reversal of FL expansion. This work provides a starting point for further study into the use of fenestration in controlling undesirable FL expansion. CLINICAL IMPACT: Aortic growth and false lumen (FL) patency are associated with the presence of re-entry tears in type B aortic dissection (TBAD) patients. Guidelines on how to treat re-entry tears are lacking, especially with regards to the control and prevention of FL expansion. Through a combined imagining and computational hemodynamics study of a controlled swine model, we found that increasing the number of re-entry tears reduced FL pressure and cross lumen pressure difference, potentially stabilising aortic growth and leading to FL reduction. Our findings provide a starting point for further study into the use of fenestration in controlling undesirable FL expansion.

6.
Biomedicines ; 10(6)2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35740339

RESUMO

The aortic valve (AoV) is the outflow valve for the left heart [...].

7.
Front Bioeng Biotechnol ; 10: 831903, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35433660

RESUMO

Thoracic endovascular aortic repair (TEVAR) is a common treatment for Stanford type B aortic dissection (TBAD). However, re-entry tears might be found distal to the stented region which transports blood between the true and false lumens. Sealing the re-entry tears, especially for the thoracic tears, could further reduce blood perfusion to the false lumen; however, it might also bring risks by re-intervention or surgery. Wise determination of the necessity to seal the re-entry tears is needed. In this study, patient-specific models of TBAD were reconstructed, and the modified models were established by virtually excluding the thoracic re-entries. Computational hemodynamics was investigated, and the variation of the functional index and first balance position (FBP) of the luminal pressure difference, due to the sealing of the re-entries, was reported. The results showed that the direction of the net flow through the unstented thoracic re-entries varied among cases. Excluding the re-entries with the net flow toward the false lumen may induce the FBP moving distally and the relative particle residence time increasing in the false lumen. This study preliminarily demonstrated that the hemodynamic status of the re-entry tears might serve as an indicator to the necessity of sealing. By quantifying the through-tear flow exchange and shift of FBP, one can predict the hemodynamic benefit by sealing the thoracic re-entries and thus wisely determine the necessity of further interventional management.

8.
Biomech Model Mechanobiol ; 21(1): 261-275, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079931

RESUMO

False lumen thrombosis (FLT) in type B aortic dissection has been associated with the progression of dissection and treatment outcome. Existing computational models mostly assume rigid wall behavior which ignores the effect of flap motion on flow and thrombus formation within the FL. In this study, we have combined a fully coupled fluid-structure interaction (FSI) approach with a shear-driven thrombosis model described by a series of convection-diffusion reaction equations. The integrated FSI-thrombosis model has been applied to an idealized dissection geometry to investigate the interaction between vessel wall motion and growing thrombus. Our simulation results show that wall compliance and flap motion can influence the progression of FLT. The main difference between the rigid and FSI models is the continuous development of vortices near the tears caused by drastic flap motion up to 4.45 mm. Flap-induced high shear stress and shear rates around tears help to transport activated platelets further to the neighboring region, thus speeding up thrombus formation during the accelerated phase in the FSI models. Reducing flap mobility by increasing the Young's modulus of the flap slows down the thrombus growth. Compared to the rigid model, the predicted thrombus volume is 25% larger using the FSI-thrombosis model with a relatively mobile flap. Furthermore, our FSI-thrombosis model can capture the gradual effect of thrombus growth on the flow field, leading to flow obstruction in the FL, increased blood viscosity and reduced flap motion. This model is a step closer toward simulating realistic thrombus growth in aortic dissection, by taking into account the effect of intimal flap and vessel wall motion.


Assuntos
Dissecção Aórtica , Trombose , Simulação por Computador , Humanos , Modelos Cardiovasculares , Estresse Mecânico
9.
Comput Biol Med ; 140: 105053, 2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34847383

RESUMO

Quantitative assessment of the complex hemodynamic environment in type B aortic dissection (TBAD) through computational fluid dynamics (CFD) simulations can provide detailed insights into the disease and its progression. As imaging and computational technologies have advanced, methodologies have been developed to increase the accuracy and physiological relevance of CFD simulations. This study presents a patient-specific workflow to simulate blood flow in TBAD, utilising the maximum amount of in vivo data available in the form of CT images, 4D-flow MRI and invasive Doppler-wire pressure measurements, to implement the recommended current best practice methodologies in terms of patient-specific geometry and boundary conditions. The study aimed to evaluate and verify this workflow through detailed qualitative and quantitative comparisons of the CFD and in vivo data. Based on data acquired from five TBAD patients, a range of essential model inputs was obtained, including inlet flow waveforms and 3-element Windkessel model parameters, which can be utilised in further studies where in vivo flow data is not available. Local and global analysis showed good consistency between CFD results and 4D-MRI data, with the maximum velocity in the primary entry tear differing by up to 0.3 m/s, and 80% of the analysed regions achieving moderate or strong correlations between the predicted and in vivo velocities. CFD predicted pressures were generally well matched to the Doppler-wire measurements, with some deviation in peak systolic values. Overall, this study presents a validated comprehensive workflow with extensive data for CFD simulation of TBAD.

10.
Biomech Model Mechanobiol ; 20(2): 481-490, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33068193

RESUMO

In order for computational fluid dynamics to provide quantitative parameters to aid in the clinical assessment of type B aortic dissection, the results must accurately mimic the hemodynamic environment within the aorta. The choice of inlet velocity profile (IVP) therefore is crucial; however, idealised profiles are often adopted, and the effect of IVP on hemodynamics in a dissected aorta is unclear. This study examined two scenarios with respect to the influence of IVP-using (a) patient-specific data in the form of a three-directional (3D), through-plane (TP) or flat IVP; and (b) non-patient-specific flow waveform. The results obtained from nine simulations using patient-specific data showed that all forms of IVP were able to reproduce global flow patterns as observed with 4D flow magnetic resonance imaging. Differences in maximum velocity and time-averaged wall shear stress near the primary entry tear were up to 3% and 6%, respectively, while pressure differences across the true and false lumen differed by up to 6%. More notable variations were found in regions of low wall shear stress when the primary entry tear was close to the left subclavian artery. The results obtained with non-patient-specific waveforms were markedly different. Throughout the aorta, a 25% reduction in stroke volume resulted in up to 28% and 35% reduction in velocity and wall shear stress, respectively, while the shape of flow waveform had a profound influence on the predicted pressure. The results of this study suggest that 3D, TP and flat IVPs all yield reasonably similar velocity and time-averaged wall shear stress results, but TP IVPs should be used where possible for better prediction of pressure. In the absence of patient-specific velocity data, effort should be made to acquire patient's stroke volume and adjust the applied IVP accordingly.


Assuntos
Dissecção Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Humanos , Pressão , Estresse Mecânico , Sístole/fisiologia , Trombose/patologia , Fatores de Tempo
11.
J Endovasc Ther ; 27(3): 396-404, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32364001

RESUMO

Purpose: To report a study that assesses the influence of the distance between the distal end of a thoracic stent-graft and the first reentry tear (SG-FRT) on the progression of false lumen (FL) thrombosis in patients who underwent thoracic endovascular aortic repair (TEVAR). Materials and Methods: Three patient-specific geometrical models were reconstructed from postoperative computed tomography scans. Two additional models were created by artificially changing the SG-FRT distance in patients 1 and 2. In all 5 models, computational fluid dynamics simulations coupled with thrombus formation modeling were performed at physiological flow conditions. Predicted FL thrombosis was compared to follow-up scans. Results: There was reduced false lumen flow and low time-averaged wall shear stress (TAWSS) in patients with large SG-FRT distances. Predicted thrombus formation and growth were consistent with follow-up scans for all patients. Reducing the SG-FRT distance by 30 mm in patient 1 increased the flow and time-averaged wall shear stress in the upper abdominal FL, reducing the thrombus volume by 9.6%. Increasing the SG-FRT distance in patient 2 resulted in faster thoracic thrombosis and increased total thrombus volume. Conclusion: The location of reentry tears can influence the progression of FL thrombosis following TEVAR. The more distal the reentry tear in the aorta the more likely it is that FL thrombosis will occur. Hence, the distal landing zone of the stent-graft should be chosen carefully to ensure a sufficient SG-FRT distance.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Hemodinâmica , Trombose/fisiopatologia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Fatores de Risco , Stents , Trombose/diagnóstico por imagem , Resultado do Tratamento , Remodelação Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA