RESUMO
BACKGROUND: Targeting maximal ventricular resynchronization, with the shortest QRS duration (QRSd), is commonly implemented after cardiac resynchronization therapy (CRT). OBJECTIVE: The purpose of this study was to compare optimization of ventricular resynchronization with optimization of left ventricular (LV) filling during CRT by measuring their acute hemodynamic effects. METHODS: Patients with standard CRT indications, recruited from 2 centers, underwent biventricular pacing (BVP) and left bundle branch pacing (LBBP). We performed a within-patient comparison of acute hemodynamic response of systolic blood pressure (SBP) at the atrioventricular delay (AVD) with the shortest QRSd against the AVD with the most efficient LV filling. In a validation substudy, we also performed electrical assessment using QRS area (QRSa) and hemodynamic assessment with the maximum rate of LV pressure rise (dP/dtmax). RESULTS: Thirty patients (age 65 ± 10 years; 53% male) were recruited. The AVD producing maximal ventricular resynchronization was associated with a significantly shorter QRSd (difference 15 ± 12 ms for BVP and 18 ± 13 ms for LBBP, both P <.01) and a significantly smaller improvement in SBP (difference -3 ± 4 mm Hg for BVP and -2 ± 2 mm Hg for LBBP, both P <.01) compared with the AVD that optimized filling. Similar findings were observed in the substudy, with a significantly smaller improvement in dP/dtmax assessed with QRSd and QRSa (difference -9% ± 7% and -6% ± 4% during BVP, and -5% ± 6% and -3% ± 3% during LBBP, all P <.01). CONCLUSION: Targeting the maximal ventricular resynchronization results in suboptimal acute hemodynamic performance with both BVP and LBBP as CRT. These findings support prioritizing LV filling when programming AVD for CRT.
RESUMO
BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.
RESUMO
Implantable cardioverter defibrillators (ICDs) have a long history and have progressed significantly since the 1980s. They have become an essential part of the prevention of sudden cardiac death, with a proven survival benefit in selected patient groups. However, with more recent trials and with the introduction of contemporary heart failure therapy, there is a renewed interest and new questions regarding the role of a primary prevention ICD, especially in patients with heart failure of non-ischaemic aetiology. This review looks at the history and evolution of ICDs, appraises the traditional evidence for ICDs and looks at issues relating to patient selection, risk stratification, competing risk, future directions and a proposed contemporary ICD decision framework.
RESUMO
Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41-0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67-1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.
RESUMO
AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14â ms, P < 0.01 and 83 ± 18 vs. 90 ± 15â ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2â V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8â mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.
Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodosRESUMO
Background: Stroke is a feared complication of transcatheter aortic valve replacement (TAVR), which embolic protection devices (EPDs) may mitigate. This systematic review and meta-analysis synthesized randomized controlled trials (RCTs) to evaluate the effect of EPDs in TAVR. Methods: All RCTs comparing EPDs with control during TAVR were systematically identified. Prespecified primary end points were all stroke, disabling stroke, nondisabling stroke, and all-cause mortality. Safety and neuroimaging parameters were assessed. Sensitivity analyses were stratified by EPD type. Study registration was a priori (CRD42022377939). Results: Eight trials randomizing 4043 patients were included. There was no significant difference between EPDs and control for all stroke (relative risk [RR], 0.88; 95% CI, 0.65-1.18; P = .39; I2 = 0%), disabling stroke (RR, 0.67; 95% CI, 0.31-1.46; P = .32; I2 = 8.6%), nondisabling stroke (RR, 0.99; 95% CI, 0.71-1.40; P = .97; I2 = 0%), or all-cause mortality (RR, 0.87; 95% CI, 0.43-1.78; P = .71; I2 = 2.3%). There were no differences in safety end points of bleeding, vascular complications, or acute kidney injury. EPDs did not result in differences in total lesion volume or the number of new lesions. The Sentinel EPD significantly reduced the risk of disabling stroke (RR, 0.42; 95% CI, 0.20-0.88; P = .022; I2 = 0%) but did not affect all stroke, nondisabling stroke, or all-cause mortality. Conclusions: The totality of randomized data for EPDs during TAVR demonstrated no safety concerns or significant differences in clinical or neuroimaging end points. Analyses restricted to the Sentinel EPD demonstrated large, clinically meaningful reductions in disabling stroke. Ongoing RCTs may help validate these results.
RESUMO
BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.
Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , GadolínioRESUMO
AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodosRESUMO
AIMS: Additional randomized clinical trial (RCT) data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) is available, including longer term follow-up. A meta-analysis comparing TAVI to SAVR was performed. A pragmatic risk classification was applied, partitioning lower-risk and higher-risk patients. METHODS AND RESULTS: The main endpoints were death, strokes, and the composite of death or disabling stroke, occurring at 1 year (early) or after 1 year (later). A random-effects meta-analysis was performed. Eight RCTs with 8698 patients were included. In lower-risk patients, at 1 year, the risk of death was lower after TAVI compared with SAVR [relative risk (RR) 0.67; 95% confidence interval (CI) 0.47 to 0.96, P = 0.031], as was death or disabling stroke (RR 0.68; 95% CI 0.50 to 0.92, P = 0.014). There were no differences in strokes. After 1 year, in lower-risk patients, there were no significant differences in all main outcomes. In higher-risk patients, there were no significant differences in main outcomes. New-onset atrial fibrillation, major bleeding, and acute kidney injury occurred less after TAVI; new pacemakers, vascular complications, and paravalvular leak occurred more after TAVI. CONCLUSION: In lower-risk patients, there was an early mortality reduction with TAVI, but no differences after later follow-up. There was also an early reduction in the composite of death or disabling stroke, with no difference at later follow-up. There were no significant differences for higher-risk patients. Informed therapy decisions may be more dependent on the temporality of events or secondary endpoints than the long-term occurrence of main clinical outcomes.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologiaRESUMO
AIMS: The effect of atrial fibrillation catheter ablation on cardiovascular outcomes in heart failure is an important outstanding research question. We undertook a meta-analysis of randomized controlled trials comparing ablation to medical therapy in patients with AF and heart failure. METHODS AND RESULTS: We systematically identified all trials comparing catheter ablation to medical therapy in patients with heart failure and atrial fibrillation. The pre-specified primary endpoint was all-cause mortality in trials with at least 2 years of follow-up. The secondary endpoint was heart failure hospitalization. Sensitivity analyses were performed for trials with any follow-up and trials deemed at low risk of bias. Eight trials (1390 patients) were included. Seven hundred and seven patients were randomized to catheter ablation and 683 to medical therapy. In the primary analysis (three trials, n = 977), catheter ablation reduced mortality compared with medical therapy [relative risk (RR): 0.61, 95% confidence interval (CI): 0.44 to 0.84, P = 0.003]. Catheter ablation also reduced heart failure hospitalizations compared with medical therapy (RR: 0.60, 95% CI: 0.49-0.74, P < 0.001). The effect on stroke was not statistically significant (RR: 0.62, 95% CI: 0.28-1.37, P = 0.237). There was low heterogeneity between studies. Sensitivity analyses were consistent with the primary analyses. CONCLUSION: In patients with atrial fibrillation and heart failure, catheter ablation reduces mortality and the occurrence of heart failure hospitalizations.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Antiarrítmicos/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ablação por Cateter/métodos , Resultado do TratamentoRESUMO
Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Doença do Sistema de Condução Cardíaco/terapia , Sistema de Condução Cardíaco , Função Ventricular Esquerda , Volume Sistólico/fisiologia , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapiaRESUMO
BACKGROUND: Hemodynamically optimal atrioventricular (AV) delay can be derived by echocardiography or beat-by-beat blood pressure (BP) measurements, but analysis is labor intensive. Laser Doppler perfusion monitoring measures blood flow and can be incorporated into future implantable cardiac devices. We assess whether laser Doppler can be used instead of BP to optimize AV delay. METHODS: Fifty eight patients underwent 94 AV delay optimizations with biventricular or His-bundle pacing using laser Doppler and simultaneous noninvasive beat-by-beat BP. Optimal AV delay was defined using a curve of hemodynamic response to switching from AAI (reference state) to DDD (test state) at several AV delays (40-320 ms), with automatic quality control checking precision of the optimum. Five subsequent patients underwent an extended protocol to test the impact of greater numbers of alternations on optimization quality. RESULTS: 55/94 optimizations passed quality control resulting in an optimal AV delay on laser Doppler similar to that derived by BP (median absolute deviation 12 ms). An extended protocol with increasing number of replicates consistently improved quality and reduced disagreement between laser Doppler and BP optima. With only five replicates, no optimization passed quality control, and the median absolute deviation would be 29 ms. These improved progressively until at 50 replicates, all optimizations passed quality control and the median absolute deviation was only 13 ms. CONCLUSIONS: Laser Doppler perfusion produces hemodynamic optima equivalent to BP. Quality control can be automatic. Adding more replicates, consistently improves quality. Future implantable devices could use such methods to dynamically and reliably optimize AV delays.
Assuntos
Nó Atrioventricular , Marca-Passo Artificial , Biomarcadores , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração , Hemodinâmica , HumanosRESUMO
Aims: Accurately determining atrial arrhythmia mechanisms from a 12-lead electrocardiogram (ECG) can be challenging. Given the high success rate of cavotricuspid isthmus (CTI) ablation, identification of CTI-dependent typical atrial flutter (AFL) is important for treatment decisions and procedure planning. We sought to train a convolutional neural network (CNN) to classify CTI-dependent AFL vs. non-CTI dependent atrial tachycardia (AT), using data from the invasive electrophysiology (EP) study as the gold standard. Methods and results: We trained a CNN on data from 231 patients undergoing EP studies for atrial tachyarrhythmia. A total of 13 500 five-second 12-lead ECG segments were used for training. Each case was labelled CTI-dependent AFL or non-CTI-dependent AT based on the findings of the EP study. The model performance was evaluated against a test set of 57 patients. A survey of electrophysiologists in Europe was undertaken on the same 57 ECGs. The model had an accuracy of 86% (95% CI 0.77-0.95) compared to median expert electrophysiologist accuracy of 79% (range 70-84%). In the two thirds of test set cases (38/57) where both the model and electrophysiologist consensus were in agreement, the prediction accuracy was 100%. Saliency mapping demonstrated atrial activation was the most important segment of the ECG for determining model output. Conclusion: We describe the first CNN trained to differentiate CTI-dependent AFL from other AT using the ECG. Our model matched and complemented expert electrophysiologist performance. Automated artificial intelligence-enhanced ECG analysis could help guide treatment decisions and plan ablation procedures for patients with organized atrial arrhythmias.
RESUMO
BACKGROUND: The efficacy of renal denervation has been controversial, but the procedure has now undergone several placebo-controlled trials. New placebo-controlled trial data has recently emerged, with longer follow-up of one trial and the full report of another trial (which constitutes 27% of the total placebo-controlled trial data). We therefore sought to evaluate the effect of renal denervation on ambulatory and office blood pressures in patients with hypertension. METHODS: We systematically identified all blinded placebo-controlled randomized trials of catheter-based renal denervation for hypertension. The primary efficacy outcome was ambulatory systolic blood pressure change relative to placebo. A random-effects meta-analysis was performed. RESULTS: 6 studies randomizing 1232 patients were eligible. 713 patients were randomized to renal denervation and 519 to placebo. Renal denervation significantly reduced ambulatory systolic blood pressure (-3.52 mmHg; 95% CI -4.94 to -2.09; p < 0.0001), ambulatory diastolic blood pressure (-1.93 mmHg; 95% CI -3.04 to -0.83, p = 0.0006), office systolic blood pressure size (-5.10 mmHg; 95% CI -7.31 to -2.90, p < 0.0001) and office diastolic pressure (effect size -3.11 mmHg; 95% CI -4.43 to -1.78, p < 0.0001). Adverse events were rare and not more common with denervation. CONCLUSIONS: The totality of blinded, randomized placebo-controlled data shows that renal denervation is safe and provides genuine reduction in blood pressure for at least 6 months post-procedure. If this effect continues in the long term, renal denervation might provide a life-long 10% relative risk reduction in major adverse cardiac events and 7.5% relative risk reduction in all-cause mortality.
Assuntos
Anti-Hipertensivos , Hipertensão , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Denervação , Humanos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/cirurgia , Rim , Ensaios Clínicos Controlados Aleatórios como Assunto , Simpatectomia/efeitos adversos , Simpatectomia/métodos , Resultado do TratamentoRESUMO
Background: Guidelines provide class I recommendations for aortic valve intervention for patients with symptomatic severe aortic stenosis (AS) or reduced ejection fraction, but the cornerstone of management for asymptomatic patients has been watchful waiting. This is based on historical nonrandomized data, but randomized controlled trials (RCTs) have now been performed of early surgical aortic valve replacement (SAVR) for asymptomatic severe AS. We performed a meta-analysis of RCTs comparing early SAVR to watchful waiting for asymptomatic severe AS, focusing on individual end points of death and heart failure (HF) hospitalization. Methods: We systematically identified all RCTs comparing early SAVR to watchful waiting in patients with asymptomatic severe AS and synthesized the data in a random-effects meta-analysis. The prespecified primary end point was all-cause mortality. Results: Two trials randomizing 302 patients were included. Early SAVR lead to a 55% reduction in all-cause mortality (hazard ratio, 0.45; 95% confidence interval, 0.24-0.85; P = .014). There was no heterogeneity (I2 = 0.0%). Early SAVR also lead to a 79% reduction in HF hospitalization (hazard ratio, 0.21; 95% confidence interval, 0.05-0.96; P = .044). Conclusions: In patients with severe asymptomatic AS and normal ejection fraction, early SAVR reduces death and HF hospitalization compared to initial conservative management. This challenges current treatment standards and has implications for the clinical care of these patients and for guidelines.
RESUMO
BACKGROUND: His bundle pacing (HBP) can be achieved in 2 ways: selective HBP (S-HBP), where the His bundle is captured alone, and nonselective HBP (NS-HBP), where local myocardium is also captured, resulting a pre-excited electrocardiogram appearance. OBJECTIVE: We assessed the impact of this ventricular pre-excitation on left and right ventricular dyssynchrony. METHODS: We recruited patients who displayed both S-HBP and NS-HBP. We performed noninvasive epicardial electrical mapping for left and right ventricular activation time (LVAT and RVAT) and pattern. RESULTS: Twenty patients were recruited. In the primary analysis, the mean within-patient change in LVAT from S-HBP to NS-HBP was -5.5 ms (95% confidence interval: -0.6 to -10.4, noninferiority P < .0001). NS-HBP did not prolong RVAT (4.3 ms, -4.0 to 12.8, P = .296) but did prolong QRS duration (QRSd, 22.1 ms, 11.8 to 32.4, P = .0003). In patients with narrow intrinsic QRS (n = 6), NS-HBP preserved LVAT (-2.9 ms, -9.7 to 4.0, P = .331) but prolonged QRS duration (31.4 ms, 22.0 to 40.7, P = .0003) and mean RVAT (16.8 ms, -5.3 to 38.9, P = .108) compared to S-HBP. Activation pattern of the left ventricular surface was unchanged between S-HBP and NS-HBP, but NS-HBP produced early basal right ventricular activation that was not seen in S-HBP. CONCLUSION: Compared to S-HBP, local myocardial capture during NS-HBP produces pre-excitation of the basal right ventricle resulting in QRS duration prolongation. However, NS-HBP preserves the left ventricular activation time and pattern of S-HBP. Left ventricular dyssynchrony is not an important factor when choosing between S-HBP and NS-HBP in most patients.