Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Circulation ; 139(14): 1674-1683, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30813758

RESUMO

BACKGROUND: Procedural results for percutaneous coronary intervention (PCI) in coronary vessels with chronic total occlusion (CTO) have improved in recent years, and PCI strategies have moved toward more complete revascularization with more liberal use of CTO-PCI. However, evidence evaluating CTO-PCI is limited to observational studies and small clinical trials. METHODS: In this open-label, multicenter, randomized, noninferiority trial, PCI-eligible patients were assigned to receive either 1 of 2 strategies: PCI or no PCI for the qualifying de novo CTO lesion with the option for PCI of obstructive non-CTO lesions at the discretion of the operator. The primary end point was a composite of death, myocardial infarction, stroke, or any revascularization. Health-related quality of life was assessed at baseline and at 1, 6, 12, 24, and 36 months. Because of slow recruitment, the trial was stopped before completion of the 1284 planned enrollments. RESULTS: Between March 2010 and September 2016, 834 patients were randomly assigned to the CTO-PCI (n=417) or no CTO-PCI (n=398) strategy. Among the patients assigned to the no CTO-PCI strategy, 78 (19.6%) crossed over to receive staged CTO-PCI within 3 days of randomization. The overall CTO-PCI success rate was 90.6%. Serious nonfatal complications associated with CTO-PCI occurred in 3 patients (1 stroke, 1 cardiac tamponade, and 1 patient with recurrent episodes of ventricular tachyarrhythmia induced by intracoronary thrombus). Approximately half of the patients in each group underwent PCI for an average of 1.3 non-CTO lesions, resulting in a comparable residual SYNTAX score (Synergy Between PCI With TAXUS and Cardiac Surgery; 3.7±5.4 versus 4.0±5.9, P=0.42) confined to non-CTO vessels. During a median follow-up of 4.0 years (interquartile range, 2.4 to 5.1 years), there was no significant difference between the CTO-PCI and the no CTO-PCI strategies in the incidence of the primary end point (22.3% versus 22.4%, hazard ratio, 1.03; 95% CI, 0.77 to 1.37; P=0.86). Both CTO-PCI and no CTO-PCI strategy were associated with significant improvements but without between-group differences in disease-specific health status that was sustained through 36 months. CONCLUSIONS: CTO-PCI was feasible with high success rates. There was no difference in the incidence of major adverse cardiovascular events with CTO-PCI versus no CTO-PCI, but the study was limited by low power for clinical end points and high crossover rates between groups. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01078051.


Assuntos
Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Idoso , Ásia/epidemiologia , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Stents Farmacológicos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Qualidade de Vida , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Taquicardia Ventricular/epidemiologia , Fatores de Tempo , Resultado do Tratamento
2.
Am J Cardiol ; 113(4): 580-7, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24388622

RESUMO

Although lipid-lowering therapy with statin and ezetimibe has been reported to provide greater reduction in low-density lipoprotein cholesterol levels than statin monotherapy, the effect of supplemental therapy on plaque stabilization is yet to be fully elucidated. Cap thickness of fibroatheroma evaluated by optical coherence tomography (OCT) is a major determinant of vulnerable plaque. The primary objective of this study is to evaluate the effect of ezetimibe in addition to fluvastatin on the progression of coronary atherosclerotic plaque evaluated by OCT. Sixty-three patients with angina pectoris with intermediate, nonculprit, lipid-rich plaque lesions evaluated by OCT were enrolled. The patients were divided into 2 groups: ezetimibe (10 mg/day) + fluvastatin (30 mg/day), and fluvastatin (30 mg/day) alone, and serial OCT examinations were performed at baseline and 9-month follow-up. A total of 57 patients (ezetimibe + fluvastatin, n = 31; fluvastatin alone, n = 26) underwent serial OCT examinations. The change in low-density lipoprotein cholesterol level was significantly larger in the ezetimibe + fluvastatin group compared with fluvastatin-alone group (-34.0 ± 32.0 vs -8.3 ± 17.4 mg/dl, p <0.001). Fibrous cap thickness was significantly increased and the angle of the lipid plaque was significantly decreased in both groups. The change in the fibrous cap thickness was significantly greater in the ezetimibe + fluvastatin group (0.08 ± 0.08 mm vs 0.04 ± 0.06 mm, p <0.001). In conclusion, lipid-lowering therapy by ezetimibe + fluvastatin could increase the fibrous cap thickness of lipid-rich plaque compared with fluvastatin monotherapy.


Assuntos
Anticolesterolemiantes/uso terapêutico , Azetidinas/uso terapêutico , Vasos Coronários/patologia , Ácidos Graxos Monoinsaturados/uso terapêutico , Indóis/uso terapêutico , Placa Aterosclerótica/diagnóstico , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticolesterolemiantes/administração & dosagem , Azetidinas/administração & dosagem , LDL-Colesterol/sangue , Progressão da Doença , Quimioterapia Combinada , Ezetimiba , Ácidos Graxos Monoinsaturados/administração & dosagem , Feminino , Fluvastatina , Seguimentos , Humanos , Indóis/administração & dosagem , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/sangue , Placa Aterosclerótica/tratamento farmacológico , Estudos Prospectivos
3.
JACC Cardiovasc Interv ; 7(1): 39-46, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24456717

RESUMO

OBJECTIVES: This study sought to compare the initial success rate of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) in a native coronary artery (NCA) in patients with and without previous coronary artery bypass grafting (CABG) and to assess predictive factors. BACKGROUND: Landmark novel wiring techniques for CTO-PCI have contributed to improvement in the initial success of CTO-PCI. However, challenges persist in CTO-PCI in NCA in pCABG patients. METHODS: Patients who underwent CTO-PCI in an NCA were selected and classified into 2 groups: pCABG (206 PCIs in 153 patients) and nCABG (1,431 PCIs in 1,139 patients). RESULTS: CTO was located more often in the left anterior descending artery (p = 0.0003), and severe calcified lesions were observed more frequently in the pCABG group (p < 0.0001). Although the retrograde attempt was tried more frequently in the pCABG group, the CTO-PCI success rate was significantly lower in the pCABG patients than in the nCABG patients (71% vs. 83%). Longer procedural time and greater radiation exposure were needed in the pCABG patients. Logistic regression analysis among the pCABG patients revealed that intravascular ultrasound use and parallel wiring were positive factors, and lesion tortuosity was a negative factor. CONCLUSIONS: The initial success rate of CTO-PCI of an NCA in the pCABG group was significantly decreased compared with that in the nCABG group. Anatomic complexity and unstable hemodynamic state were unfavorable conditions. This study reveals that the issues to be overcome are lying with CTO revascularization in an NCA in pCABG patients.


Assuntos
Ponte de Artéria Coronária , Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Idoso , Doença Crônica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Feminino , Hemodinâmica , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Doses de Radiação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
JACC Cardiovasc Interv ; 6(7): 746-55, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23769651

RESUMO

OBJECTIVES: The aim of this study was to evaluate the relationship between cholesterol metabolism and coronary plaque vulnerability. BACKGROUND: Cholesterol homeostasis, defined as the balance between absorption and synthesis, influences the progression of coronary atherosclerosis. METHODS: Consecutive stable angina pectoris patients (N = 80) not receiving any lipid-lowering therapy were divided into 2 groups based on the presence of in vivo thin cap fibroatheroma (TCFA) in de novo target vessels assessed by the combined use of virtual histology intravascular ultrasound and optical coherence tomography. RESULTS: Patients with in vivo TCFA (n = 42) showed a higher campesterol-to-lathosterol ratio (3.36 [interquartile range, 2.10 to 4.26] vs. 1.50 [1.20 to 2.50], p < 0.0001). The campesterol-to-lathosterol ratio, low-density lipoprotein (LDL) cholesterol, and high-sensitivity C-reactive protein (hsCRP) were positively correlated with the percentage of necrotic core volume (r = 0.520, p < 0.0001; r = 0.520, p < 0.0001; and r = 0.539, p < 0.0001, respectively) and negatively correlated with thinnest fibrous cap thickness (r = -0.566, p < 0.0001; r = -0.530, p < 0.0001; and r = -0.358, p = 0.007, respectively) . The independent predictors of the incidence of TCFA were the campesterol-to-lathosterol ratio (odds ratio: 3.989, 95% confidence interval: 1.688 to 9.428; p = 0.002), LDL cholesterol (odds ratio: 1.425, 95% confidence interval: 1.023 to 1.985; p = 0.03), hsCRP (odds ratio: 1.025, 95% confidence interval: 1.003 to 1.047; p = 0.02), and the percentage of necrotic core volume (odds ratio:1.084, 95% confidence interval: 1.012 to 1.161; p = 0.02). CONCLUSIONS: Enhanced absorption and reduced synthesis of cholesterol may be related to coronary plaque vulnerability.


Assuntos
Colesterol/sangue , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários , Placa Aterosclerótica , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Angina Estável/sangue , Angina Estável/diagnóstico , Angina Estável/diagnóstico por imagem , Angina Estável/patologia , Angina Estável/fisiopatologia , Biomarcadores/sangue , Proteína C-Reativa/análise , Distribuição de Qui-Quadrado , Colesterol/análogos & derivados , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/metabolismo , Vasos Coronários/patologia , Progressão da Doença , Feminino , Fibrose , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Necrose , Razão de Chances , Fitosteróis/sangue , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco , Ruptura Espontânea
5.
Eur Heart J Cardiovasc Imaging ; 14(3): 276-84, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22945378

RESUMO

AIMS: Restenosis of drug-eluting stents (DESs) might be different from that of bare metal stent restenosis in diverse ways including mechanisms and time course; however, these have not been fully examined. To gain insight into the mechanisms and time course of DES restenosis, we evaluated the characteristics of restenotic lesions of first generation DES using optical coherence tomography (OCT). METHODS AND RESULTS: We compared the morphological characteristics of early in-stent restenosis (<1 year: E-ISR, n = 43), late ISR (1-3 years: L-ISR, n = 22), and very late ISR (>3 years: VL-ISR, n = 21). OCT qualitative restenotic tissue analysis included the assessment of tissue structure [homogeneous or four types of heterogeneous intima (thin-cap fibroatheroma (TCFA)-like, layered, patchy or speckled pattern)], the presence of the peri-strut low intensity area (PLIA), microvessels, disruption with cavity, and intraluminal material and was performed at every 1 mm slice of the entire stent length. In addition to a greater trend for heterogeneous intima at the later phase, TCFA-like pattern image, intra-intima microvessels were increased from the early to the very late phase. On the other hand, the speckled pattern image was decreased from the early to the very late phase. CONCLUSION: The OCT morphological characteristics of DES restenotic tissue varied at different time-points. OCT images in early DES ISR might be associated with delayed arterial healing, and neoatherosclerosis might contribute to late catch-up phenomenon (L-ISR and VL-ISR) after DES implantation.


Assuntos
Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Software , Fatores de Tempo
6.
Catheter Cardiovasc Interv ; 81(1): E29-35, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22517538

RESUMO

OBJECTIVE: We evaluated, using quantitative coronary angiography, the natural history of change that occurred in target lesions after successful sirolimus-eluting stent (SES) implantation. BACKGROUND: Percutaneous coronary intervention with drug-eluting stents (DES) has significantly reduced the rate of repeated target lesion revascularization. However, early studies have raised concerns regarding the "late catch-up" phenomenon of DES. METHODS: Between June 2004 and March 2007, consecutive 217 patients with 306 lesions without restenosis at early angiographic follow-up underwent late angiographic follow-up (early follow-up: 11.2 ± 2.1 months and late follow-up: 29.4 ± 5.2 months). Predictors of late catch-up were identified with univariate and multivariate regression analyses. RESULTS: Although reference vessel diameter did not significantly change during follow-up [3.15 mm (interquartile range (IQR): 2.81-3.49 mm), 3.12 mm (IQR: 2.79-3.47 mm), and 3.08 mm (IQR: 2.76-3.46 mm) at postprocedure, and early and late angiographic follow-up, respectively; P = 0.2653], late loss (LL) significantly increased during follow-up [0.05 mm (IQR: 0.00-0.13 mm) and 0.08 mm (IQR: 0.01-0.19 mm) at early and late follow-up, respectively; P < 0.0001]. Univariate analysis showed previous intervention, adjunctive use of cutting balloon, lesion length, and progression of MLD, LL, %DS at early follow-up as predictors of late catch-up. Multivariate regression analysis identified %DS at early follow-up as a predictor of late catch-up (OR 1.076, CI 1.039-1.114, P < 0.0001). CONCLUSION: Significant and continuous progression of neointima after SES implantation was observed in the present study. Larger LL may be a sign of late catch-up phenomenon.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/administração & dosagem , Idoso , Análise de Variância , Estudos de Coortes , Estenose Coronária/mortalidade , Teste de Esforço , Feminino , Seguimentos , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Análise Multivariada , Falha de Prótese , Análise de Regressão , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
7.
Circ Cardiovasc Interv ; 5(2): 193-201, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22456026

RESUMO

BACKGROUND: Frequency-domain optical coherence tomography (FD-OCT) is a novel, high resolution intravascular imaging modality. Intravascular ultrasound (IVUS) is a widely used conventional imaging modality for achieving optimal stent deployment. The aim of this study was to evaluate the impact of FD-OCT guidance for coronary stent implantation compared with IVUS guidance. METHODS AND RESULTS: A total of 70 patients with de novo coronary artery lesions and either unstable or stable angina pectoris were enrolled in this randomized study (optical coherence tomography [OCT] group: n=35, IVUS group: n=35). In the OCT group, stent implantation was performed under FD-OCT guidance alone and final stent expansion was evaluated by IVUS. In the IVUS group, conventional IVUS guidance was used and final stent apposition was evaluated by FD-OCT. There were no significant differences regarding the procedural, fluoroscopy time, and contrast volume. Although device and clinical success rates also were similar, the visibility of vessel border was significantly lower in the OCT group (P<0.05). Minimum and mean stent area and focal and diffuse stent expansion were smaller (6.1±2.2 mm versus 7.1±2.1 mm, 7.5±2.5 versus 8.7±2.4 mm, 64.7±13.7% versus 80.3±13.4%, 84.2±15.8% versus 98.8±16.5%, P<0.05, respectively), and the frequency of significant residual reference segment stenosis at the proximal edge was higher in the OCT group (P<0.05). Incomplete apposed struts in both groups were similar (P=0.34). CONCLUSIONS: FD-OCT guidance for stent implantation was associated with smaller stent expansion and more frequent significant residual reference segment stenosis compared with conventional IVUS guidance.


Assuntos
Implante de Prótese Vascular , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/cirurgia , Complicações Pós-Operatórias/cirurgia , Cirurgia Assistida por Computador , Idoso , Doença da Artéria Coronariana/patologia , Reestenose Coronária/patologia , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/patologia , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
8.
Atherosclerosis ; 221(2): 405-15, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22341594

RESUMO

BACKGROUND: Conflicting data have been reported about the association between plaque composition and remodelling index (RI). The aim of this study is to evaluate the relationship between plaque morphology obtained by optical coherence tomography (OCT) and arterial remodelling. METHODS AND RESULTS: OCT and intravascular ultrasound imaging pull back was performed at corresponding sites on 94 lesions in 47 patients. OCT plaque characteristics for lipid content, fibrous cap thickness, thin-cap fibroatheroma (TCFA), plaque rupture, thrombus, calcification and erosion were derived using validated criteria. Compared with intermediate/negative remodelling (RI<1.0), positive remodelling (RI>1.0) was associated with presence of higher lipid pool (2.86 ± 0.42 vs. 2.20 ± 0.78; p<0.001), thin fibrous cap (47.86 ± 25.43 µm vs. 74.41 ± 32.41 µm; p<0.001), TCFA>3mm (82.1% vs. 22.7%; p<0.0001), plaque rupture and thrombus (42.8% vs. 19.7%; p = 0.024), and higher plaque burden (73.70 vs. 70.70; p = 0.048). No difference was observed in the presence of calcification and plaque erosions. CONCLUSIONS: Coronary lesions with positive remodelling show higher incidences of vulnerable plaque and plaque rupture across the lesion length. This potentially explains the correlation between unstable coronary syndromes and positive remodelling.


Assuntos
Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Placa Aterosclerótica/patologia , Tomografia de Coerência Óptica , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/metabolismo , Trombose Coronária/patologia , Vasos Coronários/química , Vasos Coronários/diagnóstico por imagem , Feminino , Fibrose , Humanos , Japão , Lipídeos/análise , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/química , Placa Aterosclerótica/diagnóstico por imagem , Ruptura Espontânea , Ultrassonografia de Intervenção , Calcificação Vascular/patologia
9.
Nihon Rinsho ; 69(2): 240-3, 2011 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-21387670

RESUMO

Recently, CTO PCI has come into wide use all over the world and it has been standardized. The 1st step is an antegrade approach using single wire. The 2nd strategy would be parallel wire technique. And the next would be a retrograde approach. In this method, retrograde wiring with Corsair is done at first. If it is successful, externalization is established using 300 cm wire, and this system is able to provide strong back-up support. If it fails, reverse CART technique is the next step. IVUS guided wiring is a last resort. The 2nd wire is manipulated with IVUS guidance. Now, initial success rate is more than 90% with these methods.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária/terapia , Angioplastia Coronária com Balão/métodos , Doença Crônica , Humanos , Ultrassonografia de Intervenção
10.
Int J Cardiol ; 146(3): 390-4, 2011 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-19709763

RESUMO

OBJECTIVE: This study compared the impact of pattern of sirolimus eluting stent restenosis (SES ISR) on the angiographic outcomes following conventional modalities of treatment. METHODS: A total of 344 consecutive patients who underwent treatment for SES ISR were included in the study. Lesions were divided into focal< 10 mm, 156 (45.3%)); and non focal> 10 mm, 188 (54.7%). The endpoints analysed were angiographic restenosis and target lesion revascularisation. A total of 31%, 41%, and 23% patients were treated with cutting balloon angioplasty, balloon angioplasty, and repeat stenting. RESULTS: Baseline characteristics were similar for two patterns, except for young age, more AMI and severe angina, more CTO lesions, long lesions, and more use of repeat stenting in non focal ISR group. Follow up angiography shows binary restenosis was significantly lower in the focal group (32.4% vs. 49.2; p = 0.012) and target lesion revascularisation were also lower with focal pattern ISR (30.6 vs. 42.9; p = 0.06). Restenosis rates are similar between balloon angioplasty and repeat stenting (28 vs. 23%) in focal ISR group, and repeat stenting showed better outcomes in the non focal group (60% vs. 36%). CONCLUSION: The recurrent ISR remains high with available treatments and the pattern of SES ISR predicted the outcomes, with lower restenosis rates with focal pattern of ISR.


Assuntos
Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia , Stents Farmacológicos , Sirolimo/administração & dosagem , Idoso , Reestenose Coronária/epidemiologia , Feminino , Humanos , Masculino , Estudos Prospectivos
11.
Coron Artery Dis ; 22(1): 64-72, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21191287

RESUMO

OBJECTIVES: The purpose of this study was to assess the prevalence and to quantify the thin-cap fibroatheroma (TCFA) and ruptured plaques in patients with coronary artery disease using optical coherence tomography (OCT). BACKGROUND: TCFA lesions are the most prevalent precursors of plaque rupture, and are responsible for acute coronary syndromes (ACS). There are limited data regarding the frequency and distribution of TCFA in diseased coronary arteries. METHODS: Coronary artery OCT was performed in 78 vessels in 47 patients, with stable angina (SA) or ACS. OCT plaque characteristics were derived using criteria that had been validated earlier. TCFA was defined as rich in lipid (two or more quadrants) with thin fibrous cap (<65 µm). Comparison was made between SA and unstable angina, and culprit and nonculprit vessels. RESULTS: There was a higher incidence of TCFA and plaque rupture (65 vs. 24%, P=0.003, and 40 vs. 15%, P=0.04) in ACS patients. This was reflected in a higher lipid pool (2.66 vs. 2.26 quadrants, P=0.04) and minimum fibrous cap thickness (52 vs. 74 µm, P=0.001) in ACS patients. The mean numbers of TCFA (2.5) were similar in patients with SA and ACS. However, the maximal length of TCFA (2.63 vs. 5.54 mm, P=0.026) and plaque rupture sites (P=0.046) were higher in ACS vessels. No relationship was found between baseline characteristics and TCFA incidence and plaque rupture. We identified ACS (P=0.002), higher mean lipid pool (P=0.002), longer TCFA length (P=0.007) and higher number of TCFA (P=0.02) as predictors of plaque rupture sites. CONCLUSION: In this in-vivo study, we identified a higher incidence of longer TCFAs and plaque rupture sites associated with ACS.


Assuntos
Síndrome Coronariana Aguda/etiologia , Angina Pectoris/etiologia , Estenose Coronária/patologia , Tomografia de Coerência Óptica , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/patologia , Idoso , Angina Pectoris/diagnóstico , Angina Pectoris/epidemiologia , Distribuição de Qui-Quadrado , Estenose Coronária/complicações , Estenose Coronária/epidemiologia , Feminino , Fibrose , Humanos , Incidência , Japão , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Ruptura , Índice de Gravidade de Doença
12.
JACC Cardiovasc Interv ; 3(10): 1074-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20965467

RESUMO

OBJECTIVES: We performed this study to investigate with optical coherence tomography (OCT) the vascular response after sirolimus-eluting stent (SES) implantation between patients with and those without diabetes mellitus (DM). BACKGROUND: The difference in vascular response after SES implantation between patients with and those without DM has not been fully evaluated with OCT. METHODS: Optical coherence tomography was performed to examine 74 nonrestenotic SES implanted in 63 patients (32 with DM and 31 without DM) at 9 months after SES implantation. For struts showing neointimal coverage, the neointimal thickness on the luminal side of each strut section was measured, and neointimal characteristics were classified into high, low, and layered signal pattern. RESULTS: Baseline patient characteristics and lesion and procedural characteristics data were similar between the 2 groups. In total, 11,422 struts were analyzed. High signal neointima was observed in 90.2 ± 13.9%, low signal neointima in 7.3 ± 10.0%, and layered neointima in 2.7 ± 5.8%/stents. There was higher incidence of low signal neointima (10.5 ± 10.3% vs. 4.5 ± 5.6%, p = 0.003), neointimal thickness was larger (median: 106.8 µm, interquartile range: 79.3 to 130.4 µm vs. median: 83.5 µm, interquartile range: 62.3 to 89.3 µm; p < 0.0001), and neointimal coverage of stent struts was higher (92.1 ± 6.2% vs. 87.2 ± 11.9%; p = 0.03) in DM patients. CONCLUSIONS: High signal neointimal pattern was predominantly observed, and low or layered signal pattern was observed in some cases. In DM patients, low signal neointima was observed with high frequency. Neointimal coverage and neointimal thickness was also higher in DM patients as compared with non-DM patients.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Diabetes Mellitus/patologia , Stents Farmacológicos , Tomografia de Coerência Óptica , Túnica Íntima/patologia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Proliferação de Células , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/patologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 75(6): 919-27, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20432398

RESUMO

OBJECTIVES: The aim of this study was to examine the binary re-stenosis rates, procedural success, and in hospital outcomes following treatment of fibro-calcified coronary lesion with rotational atherectomy in drug eluting stent era. BACKGROUND: Binary restenosis rates have remained high with the use of bare metal stents following rotational atherectomy in calcified lesions. There is limited data available following rotational atherectomy in drug eluting stent era. METHODS: We evaluated the procedural and angiographic outcomes following a consecutive series of 516 procedures treated with rotational atherectomy followed by stenting. We compared the results between Rota + Drug eluting stent (DES) and Rota + bare metal stent (BMS) groups. RESULTS: Procedural success was achieved in 97.1% of the lesions with overall low in hospital adverse events (death in 1.1%, Q MI in 1.3%, Non Q MI in 5.3%, and urgent repeat PCI in 0.4%). There was significant reduction in the binary restenosis rates following Rota + DES use as compared to Rota + BMS use (11% vs. 28.1%, P < 0.001; OR = 3.17, 95% CI: 1.76-5.93) and similar reduction was seen in the target lesion revascularization (10.6% vs. 25%, P = 0.001; OR = 2.81, 95% CI: 1.53-5.14). We have identified ostial lesions, chronic total occlusion lesions, and use of bare metal stents as independent predictors of restenosis in this group of patients. CONCLUSIONS: Rotational atherectomy can be performed with high success rates and low complications, and rotational atherectomy followed by drug eluting stent implantation significantly reduces binary restenosis rates in fibrocalcific lesions as compared to rotational atherectomy and bare metal stents.


Assuntos
Aterectomia Coronária , Calcinose/cirurgia , Cardiomiopatias/cirurgia , Idoso , Angiografia Coronária , Reestenose Coronária/epidemiologia , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Stents , Ultrassonografia de Intervenção
14.
EuroIntervention ; 5(7): 841-6, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20142201

RESUMO

AIMS: This paper studies in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) following bare-metal stent (BMS) and drug-eluting stent (DES) in all consecutive patients between 2004 and 2007 undergoing PCI for ISR lesions at our centre. METHODS AND RESULTS: We compared the clinical presentation, pattern and angiographic outcomes in 838 patients with BMS ISR (487) and SES ISR (351). About 18% of the patients presented with acute coronary syndrome with 2% presenting as ST elevation myocardial infarction, similar in both groups. Angiographic pattern was predominantly focal with SES ISR (47%SES ISR vs. 19% BMS ISR; p<0.001) and diffuse with BMS ISR (SES ISR 16% vs. BMS ISR 36%; p=0.003). In our series the use of balloon angioplasty was higher for the treatment of SES ISR patients as compared to BMS ISR (41.6% vs. 18.3%; p<0.001) and the usage of stent was higher in BMS ISR patients (38.6% vs. 23.4%; p<0.001). Angiographic recurrent restenosis with conventional treatment in a consecutive series of patients was 38.6% and target lesion revascularisation was seen in 33.6%. These outcomes were seen slightly higher in SES ISR group (41.1% vs. 36.9%, p=ns). We have identified unstable angina at presentation (OR 3.02; 95%CI: 1.58-5.77, p=0.001), focal pattern of ISR (OR 0.50; 95% CI: .25-.99, p=0.04), stent usage (OR .25; 95% CI .13-.47, p<0.001), and baseline% diameter stenosis (OR1.03; 95%CI: 1.03-1.06, p=0.01) as independent predictors of BMS ISR recurrent restenosis. Unstable angina, focal pattern of ISR, reference vessel diameter, and% diameter stenosis were shown to be independent predictors of SES ISR. CONCLUSIONS: ISR is not a benign condition, and one fifth of the patients presented with acute coronary syndrome. The pattern of restenosis is predominantly non-focal with BMS ISR and focal with SES ISR. Recurrent restenosis rates are high following conventional treatment and further optimal therapies mainly with SES ISR needs to defined.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Reestenose Coronária/etiologia , Estenose Coronária/terapia , Stents Farmacológicos , Metais , Stents , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/terapia , Idoso , Angina Instável/etiologia , Angina Instável/terapia , Fármacos Cardiovasculares/administração & dosagem , Distribuição de Qui-Quadrado , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
15.
Circ Cardiovasc Interv ; 2(2): 124-32, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20031705

RESUMO

BACKGROUND: Retrograde approach through collaterals has been introduced for percutaneous recanalization of chronic total occlusion (CTO) of the coronary arteries. We investigated the safety and efficacy of retrograde approaches used for percutaneous recanalization of CTO in a consecutive series of patients. METHODS AND RESULTS: We studied 157 consecutive patients who underwent retrograde CTO recanalization between 2003 and 2008 at a single center. A total of 118 (75.2%) of these patients have had previously failed antegrade attempts. Septal, epicardial, and saphenous vein graft collaterals were used in 67.5%, 24.8%, and 7.6% of cases, respectively. Collateral channel was crossed by guide wire successfully in 115 (73.2%) cases, and the procedure was successful by retrograde approach in 103 (65.6%) cases. Collateral channels (CCs) were graded as follows: CC0, no continuous connection; CC1, continuous thread-like connection; and CC2, continuous, small sidebranch-like connection. CC1, collateral tortuosity < 90 degrees , and angle with recipient vessel < 90 degrees (P<0.0001) were significant predictors of success. Epicardial channel use (P=0.01), CC0, corkscrew channel (P<0.0001), angle with recipient vessel > 90 degrees (P=0.0007), and nonvisibility of connection with recipient vessel were found to be significant predictors of procedural failure. The CC dissection was observed in 6 patients, with 1 needing coil embolization and others who were managed conservatively. The major adverse cardiac events were low, with 1 coronary artery bypass graft, 1 Q-wave myocardial infarction, 5 non-Q-wave myocardial infarctions, and no deaths in this group of patients. CONCLUSIONS: The retrograde approach in CTO percutaneous coronary intervention is effective in recanalizing CTO. The success rate by retrograde approach was 65.6%, and final success was 85% in this group with acceptable overall adverse events. We have identified predictors of failure related to collateral morphology.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Doença Crônica , Circulação Colateral , Angiografia Coronária , Circulação Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 2(11): 1135-41, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19926057

RESUMO

OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of a new concept for chronic total occlusion (CTO) recanalization-using a bilateral approach that utilizes a Controlled Antegrade and Retrograde subintimal Tracking (CART) technique. BACKGROUND: Successful percutaneous recanalization of coronary CTOs results in improved long-term outcomes. The recanalization of CTOs in native coronary arteries no doubt represents one of the most technically challenging of interventional procedures. METHODS: A total of 224 consecutive patients (mean age 61 +/- 9 years; 86.2% men) were enrolled in this prospective multicenter registry. This technique combines the simultaneous use of antegrade and retrograde approaches. A subintimal dissection is created in both antegrade and retrograde fashion, thereby limiting the extension of the subintimal dissection within the CTO portion. RESULTS: Of 224 CTO lesions (>3 months in duration) undergoing attempted recanalization using the CART technique, 145 cases (64.7%) had undergone previous CTO recanalization attempts. The success rates of crossing in a retrograde fashion with a wire and a balloon were 87.9% and 79.9%, respectively. The overall technical and procedural success rates achieved in this registry were 92.4% and 90.6%, respectively. CONCLUSIONS: A bilateral approach for CTO lesions using the CART technique is feasible, safe, and has a higher success rate than previous approaches. These results indicate that a bilateral technique can solve a major dilemma that commonly affects CTO procedures.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Estudos de Viabilidade , Feminino , Alemanha , Mortalidade Hospitalar , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Reino Unido
17.
EuroIntervention ; 5(3): 349-54, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19736160

RESUMO

AIMS: Drug eluting stents (DES) have been used routinely in a wide variety of clinical situations. The impact of DES on reducing restenosis has not been uniform across complex subsets and limited data is available examining predictors of restenosis in unselected population. METHODS AND RESULTS: We investigated predictors of angiographic restenosis in an unselected population. The study population consisted of 4,143 lesions and angiographic follow-up was available for 3,020 (73%) lesions in 1,885 patients. The intravascular ultrasound (IVUS) was used in 95% of the patients during the procedure. Angiographic restenosis was seen in 339 (11.2%) lesions and target lesion revascularisation was performed in 290 (9.6%) lesions. The patient population included large numbers of renal failure patients on haemodialysis, ISR, and Type C lesions with routine use of intravascular ultrasound. We identified diabetes mellitus, renal failure, Type C lesions, calcified lesion, tortuous lesion, ISR, long lesion, small baseline diameter and final vessel diameter as predictors of restenosis. On multivariate analysis diabetes (OR 1.45, 95% CI 1.07-1.97, p= 0.01), renal failure on haemodialysis (OR 2.02, 95% CI 1.37-3.27, p=0.001), ISR (OR 3.56, 95% CI 2.16-5.89, P<0.001), lesion length (OR 1.02, CI 1.01-1.03.P<0.001), reference vessel diameter (OR 0.50, 95% CI 0.31-0.80, p=0.005) and post-intervention IVUS lumen area (p<0.001) were independent predictors of angiographic restenosis. Female gender (OR 0.61, 95% CI 0.410.91, p=0.015) was found to have a negative correlation for ISR. We did not find any significant difference in restenosis between the usage of sirolimus and paclitaxel eluting stents. CONCLUSIONS: DES usage was associated with overall low in-stent restenosis and we have identified several clinical, angiographic, and IVUS predictors of angiographic restenosis in unselected patients with complex anatomy.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
18.
JACC Cardiovasc Interv ; 2(7): 689-96, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19628194

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of treatment with statins on the progression of coronary atherosclerotic plaques of a nonculprit vessel by serial volumetric virtual histology (VH) intravascular ultrasound (IVUS). BACKGROUND: Recent clinical trials have demonstrated a reduction of atherosclerotic plaque, yet whether statin therapy affects the change in components of plaque remains unknown. METHODS: This study was a nonrandomized and nonblinded design. Eighty patients with stable angina pectoris were divided into either the fluvastatin group (n = 40) or the control group (n = 40) according to their total or low-density lipoprotein (LDL) cholesterol level. The volume of each plaque component (dense calcium, fibrous tissue, fibro-fatty, or necrotic core) was evaluated at baseline and at 12-month follow-up. RESULTS: The LDL cholesterol and high-sensitivity C-reactive protein (hsCRP) levels in the fluvastatin group were significantly decreased at time of follow-up. In VH IVUS findings, fibro-fatty volume was significantly decreased (baseline 80.1 +/- 57.9 mm(3) vs. follow-up 32.5 +/- 27.7 mm(3), p < 0.0001) and fibrous tissue volume was increased (baseline 146.5 +/- 85.6 mm(3) vs. follow-up 163.3 +/- 94.5 mm(3), p < 0.0001) in the fluvastatin group. In the control group, the volumes of all plaque components without fibrous tissue were significantly increased. Change in fibro-fatty volume has a significant correlation with a change in LDL cholesterol level (R = 0.703, p < 0.0001) and change in hsCRP level (R = 0.357, p = 0.006). CONCLUSIONS: One-year lipid-lowering therapy by fluvastatin showed significant regression of plaque volume and alterations in atherosclerotic plaque composition with a significant reduction of fibro-fatty volume.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Ácidos Graxos Monoinsaturados/uso terapêutico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Indóis/uso terapêutico , Ultrassonografia de Intervenção , Interface Usuário-Computador , Idoso , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Calcinose/diagnóstico por imagem , Calcinose/tratamento farmacológico , LDL-Colesterol/sangue , Doença da Artéria Coronariana/sangue , Progressão da Doença , Ácidos Graxos Monoinsaturados/efeitos adversos , Feminino , Fibrose , Fluvastatina , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Indóis/efeitos adversos , Japão , Masculino , Pessoa de Meia-Idade , Necrose , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 2(6): 489-97, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19539251

RESUMO

The aim of this study was to examine the procedural success and in-hospital outcomes after percutaneous coronary intervention (PCI) for chronic total occlusions in the current era during contemporary practice. The technique of PCI has improved over time with the introduction of novel equipment and guidewire crossing techniques. However, there is limited data available from contemporary practice in the recent years. We evaluated the procedural and in-hospital outcomes in a consecutive series of 904 procedures performed at Toyohashi Heart Center for PCI of chronic total occlusions of >3 months in duration. Technical and procedural success was achieved in 87.5% and 86.2%, respectively. In-hospital major adverse cardiac events occurred in only 1.9% of the patients. Single antegrade wire was the predominant strategy for guidewire crossing; however, retrograde guidewire crossing was used in 7.2% of the cases and controlled antegrade and retrograde subintimal tracking in 9.9% of the cases as the final strategy. Logistic regression analysis identified severe tortuosity and moderate-to-severe calcification as significant predictors of procedural failure. This is the first reported large series of patients undergoing PCI for chronic total occlusion with improved wire crossing techniques. We have reported high success rates in recent years and very low complication rates despite the use of more aggressive devices and techniques.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Calcinose/complicações , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Bases de Dados como Assunto , Feminino , Cardiopatias/etiologia , Cardiopatias/prevenção & controle , Humanos , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
20.
J Invasive Cardiol ; 20(11): 571-7, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18987395

RESUMO

BACKGROUND: The success rate of percutaneous coronary intervention (PCI) for chronic total coronary occlusion (CTO) lesions varies depending on the guidewire manipulation skills of the operator. The standardization of guidewire technique is very important. A new technique with a new tapered wire (Conquest, Confianza Pro) was tested to verify effectiveness for higher initial success rates and standardization of PCI for CTO. METHODS: A prospective, multicenter registry was conducted at 6 investigational sites. In the CONQUEST trial, The CTO lesions were treated by using an intermediate guidewire to cross the lesion. If it did not cross, the guidewire was changed to the Conquest guidewire. If it did not cross, "seesaw-wiring" or the "parallel-wire technique" was performed. The primary endpoint was the initial procedural success rate. RESULTS: A total of 110 patients representing 116 CTO lesions were treated from July 2003 through March 2004. The procedural success rate was 86.2% on the first try, and 88.8% on the second try, respectively. The guidewire success rate on the second try was 90.5% during the hospital stay; no deaths, or acute myocardial infarctions were confirmed. Two patients deteriorated into tamponade, and surgical or percutaneous drainage was performed in each patient without any sequelae. CONCLUSIONS: A guidewire technique in PCI for CTOs that starts with the intermediate guidewire and moves to the Confianza Pro tapered guidewire, either alone or by performing a see-saw or parallel-wire technique, can achieve a high initial success rate with an acceptably low major complication rate.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Idoso , Doença Crônica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA