Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Thorac Cardiovasc Surg ; 59(5): 268-73, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21557162

RESUMO

BACKGROUND: The Aristotle score quantifies the complexity involved in congenital heart surgery. It defines surgical performance as complexity score times hospital survival. We studied how expected and observed surgical performance evolved over time. METHODS: 2312 main procedures carried out between 2006 and 2010 were analyzed. The Aristotle basic score, corresponding hospital survival and related observed surgical performance were estimated. Expected survival was based on the mortality risks published by O'Brien and coauthors. Observed performance divided by expected performance was called the standardized ratio of performance. This should trend towards a figure above 100%. Survival rates and performance are given with 95% confidence intervals. RESULTS: The mean Aristotle basic score was 7.88 ± 2.68. 51 patients died: observed hospital survival was 97.8 % (97.1 %-98.3%). 115 deaths were anticipated: expected survival was 95.2% (93.5%-96.3%). Observed and expected surgical performance reached 7.71 (7.65-7.75) and 7.49 (7.37-7.59), respectively. Therefore the overall standardized ratio of performance was 102.94%. The ratio increased from 2006 (ratio = 101.60%) to 2009 (103.92%) and was 103.42% in 2010. Performance was high for the repair of congenital corrected transposition of the great arteries and ventricular septal defect (VSD) by atrial switch and Rastelli procedure, the Norwood procedure, repair of truncus arteriosus, aortic arch repair and VSD closure, and the Ross-Konno procedure, with corresponding standardized ratios of 123.30%, 116.83%, 112.99%, 110.86% and 110.38%, respectively. With a ratio of 82.87%, performance was low for repair of Ebstein's anomaly. CONCLUSION: The standardized ratio of surgical performance integrates three factors into a single value: procedure complexity, postoperative observed survival, and comparison with expected survival. It constitutes an excellent instrument for quality monitoring of congenital heart surgery programs over time. It allows an accurate comparison of surgical performance across institutions with different case mixes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Indicadores de Qualidade em Assistência à Saúde , Análise de Variância , Benchmarking , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Competência Clínica , Alemanha , Cardiopatias Congênitas/mortalidade , Mortalidade Hospitalar , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Indicadores de Qualidade em Assistência à Saúde/estatística & dados numéricos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
2.
Thorac Cardiovasc Surg ; 58(6): 322-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20824582

RESUMO

BACKGROUND: Hospital costs are expected to correlate with clinical complexity. Do costs for congenital heart surgery correlate with Aristotle complexity scores? METHODS: 442 inpatient stays in 2008 were evaluated. Aristotle scores and levels were determined. Costs were estimated according to the German Institute for Hospital Reimbursement system. Pearson and Spearman R correlation coefficients and corresponding goodness-of-fit regression coefficients R2 were calculated. RESULTS: Mean basic and comprehensive Aristotle scores were 7.60 +/- 2.74 and 9.23 +/- 2.94 points, respectively. Mean expenses per hospital stay amounted to 29,369 +/- 30,823 Euros. Aristotle basic and comprehensive scores and levels were positively correlated with hospital costs. With a Spearman R of 1 and related R2 of 0.9436, scores of the 6 Aristotle comprehensive levels correlated best. Mean hospital reimbursement was 26,412 +/- 17,962 Euros. Compensation was higher than expenses for patients in comprehensive levels 1 to 3, but much lower for those in levels 4 to 6. CONCLUSIONS: Aristotle comprehensive complexity scores were highly correlated with hospital costs. The Aristotle score could be used as a scale to establish the correct reimbursement after congenital heart surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/economia , Cardiopatias Congênitas/economia , Cardiopatias Congênitas/cirurgia , Custos Hospitalares , Reembolso de Seguro de Saúde/economia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Cuidados Críticos/economia , Alemanha , Cardiopatias Congênitas/mortalidade , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Pacientes Internados , Tempo de Internação/economia , Modelos Econômicos , Respiração Artificial/economia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
3.
Thorac Cardiovasc Surg ; 58(6): 328-32, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20824583

RESUMO

BACKGROUND: Scores of Aristotle comprehensive complexity (ACC) levels have been demonstrated to correlate with the case-mix index (CMI) (cost-weights) generated by the German Diagnosis-Related Groups (DRG) 2009 version (G-DRG 2009). The equation used was "y = 0.5591 + 0.939 x" whereby y stands for cost-weight and x for ACC score. We hypothesised that each ACC level could be assigned a DRG (ACC DRG) and be used to determine hospital reimbursement. METHODS: 185 patients underwent cardiac surgery between January and June 2009. The ACC scores of these 185 patients were grouped in ACC levels, based on the basic cost-weight value of their DRG. One ACC DRG was assigned to each group and a corresponding cost-weight calculated based on the aforementioned equation. The resulting ACC CMI was compared with the CMI generated by the G-DRG 2009 (G-DRG 2009 CMI). Finally, the ACC surgical performance (complexity x hospital survival) was used to calculate the cost-weight; the obtained CMI was called "effective ACC CMI". RESULTS: Mean ACC score was 9.515 +/- 3.611 points. Derived ACC CMI and related G-DRG 2009 CMI were 9.494 and 8.438, respectively. Hospital survival was 97.8 % (181/184). Therefore ACC surgical performance and "effective ACC CMI" were 9.306 and 9.297, respectively. For each ACC level, the number of patients (n), mean ACC score, ACC CMI and related G-DRG 2009 CMI were as follows: Level 1: n = 25, 4.024 +/- 0.879, 4.338 and 5.911; Level 2: n = 30, 6.563 +/- 0.574, 6.722 and 6.602; Level 3: n = 43, 8.665 +/- 0.540, 8.695 and 8.088; Level 4: n = 73, 11.730 +/- 1.690, 11.574 and 9.612; Level 5: n = 14, 16.710 +/- 1.380, 16.249 and 11.843, respectively. CONCLUSIONS: The Aristotle score can be used to adjust hospital reimbursement by assigning a DRG and cost-weight value to each ACC level. Missing figures for level 6 can be obtained from a previous study which showed a mean score of 22.11 +/- 1.24: the ACC CMI would be 21.320. The 6 ACC DRGs indicate the correct compensation based on the complexity of the procedure. Reimbursement using the German DRG 2009 appears to favour less complex cases, while procedures with a higher complexity are penalised. Reimbursement according to "effective ACC CMIs" would have a strong impact by supporting units providing high-quality care.


Assuntos
Procedimentos Cirúrgicos Cardíacos/economia , Cardiopatias Congênitas/economia , Cardiopatias Congênitas/cirurgia , Custos Hospitalares , Reembolso de Seguro de Saúde/economia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Alemanha , Cardiopatias Congênitas/mortalidade , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Pacientes Internados , Tempo de Internação/economia , Modelos Econômicos , Respiração Artificial/economia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
4.
Ultrasound Obstet Gynecol ; 35(2): 183-90, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20101636

RESUMO

OBJECTIVE: To evaluate the intrauterine course and outcome of tricuspid atresia detected in the fetus. METHODS: This was a retrospective review of all confirmed cases of tricuspid atresia detected prenatally between 1998 and 2006 in three tertiary referral centers in Germany. RESULTS: Fifty-four cases of tricuspid atresia were detected prenatally during the study period and confirmed postnatally: 28 (51.9%) cases had a concordant ventriculoarterial connection of which 14 also had pulmonary outflow obstruction; 25 (46.3%) cases had a discordant ventriculoarterial connection of which 14 also had aortic outflow obstruction, six had pulmonary outflow tract obstruction and two had other associated intracardiac anomalies; and one (1.9%) had a common arterial trunk. The peak velocity index for veins in the ductus venosus was significantly elevated in 19 of the 37 (51.4%) cases assessed; however, this finding did not correlate with adverse intrauterine outcome. There were associated extracardiac anomalies in 12 cases: five with chromosomal anomalies, two with VACTERL association, one with unilateral renal agenesis, one with hypospadia, one with hydrothorax, one with megacystis and one with agenesis of the ductus venosus. Seventeen of the 54 (31.5%) cases underwent termination of pregnancy, two (3.7%) died in utero, two (3.7%) died in infancy and 33 (61.1%) children survived with a median follow-up of 26 (range, 12-120) months. Prenatal echocardiography correctly anticipated the postnatal course and the need for neonatal intervention in 29/35 (82.9%) continued pregnancies; in the remaining six (17.1%) cases the right outflow tract obstruction had been underestimated. CONCLUSIONS: Tricuspid atresia and the frequently associated intracardiac anomalies can be diagnosed in the fetus with considerable accuracy. A thorough search for extracardiac malformations should be performed in order to rule out chromosomal anomalies and multiple malformation syndromes. Elevated pulsatility in the ductus venosus does not indicate cardiac failure. The short-term overall survival in continued pregnancies in our study exceeded 89%, with the greatest rate of loss being in the first year of postnatal life.


Assuntos
Anormalidades Múltiplas/diagnóstico por imagem , Doenças Fetais/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Atresia Tricúspide/diagnóstico por imagem , Anormalidades Múltiplas/genética , Anormalidades Múltiplas/mortalidade , Aborto Induzido , Feminino , Doenças Fetais/epidemiologia , Doenças Fetais/genética , Alemanha/epidemiologia , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Atresia Tricúspide/genética , Atresia Tricúspide/mortalidade , Ultrassonografia Pré-Natal
5.
Thorac Cardiovasc Surg ; 56(7): 401-5, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18810697

RESUMO

BACKGROUND: Can Contegra grafts withstand high pressure? METHODS: The function of Contegra grafts implanted after unifocalization of major aortopulmonary collateral arteries (MAPCAs) in 10 patients was evaluated. Median age at repair was 194 days and two conduit sizes were used: 12 mm (n = 8) and 14 mm (n = 2). Echocardiography and heart catheterization findings were reviewed. RESULTS: Two patients died: one early after repair, one late. Death was not graft related. The median duration of observation for survivors was 31 (range 4 - 42) months. The postoperative right ventricular/left ventricular pressure ratio was greater than 75 % in 9 patients. High pressures persisted in 6 survivors. Seven patients underwent interventional dilatation/stenting of pulmonary arteries on 19 occasions. No obstruction was detected in the conduit. Graft valve regurgitation increased in 5 patients, but never exceeded grade 2 (n = 4). Freedom from reoperation for conduit dysfunction/failure was 100 % at month 42. CONCLUSION: At mid-term follow-up, the Contegra grafts withstood high pressure without significant dysfunction or aneurysmal dilatation requiring surgery. Contegra appears to be an acceptable alternative to the aortic homograft for use after unifocalization of MAPCAs in infancy.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Jugulares/transplante , Artéria Pulmonar/cirurgia , Anastomose Cirúrgica , Animais , Pressão Sanguínea , Implante de Prótese Vascular/efeitos adversos , Bovinos , Pré-Escolar , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Lactente , Desenho de Prótese , Falha de Prótese , Artéria Pulmonar/fisiopatologia , Reoperação , Fatores de Tempo , Resultado do Tratamento , Pressão Ventricular
6.
Arch Dis Child Fetal Neonatal Ed ; 93(4): F261-4, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18252817

RESUMO

BACKGROUND: Surgical closure of a patent ductus arteriosus (PDA) in very low birth weight (VLBW) infants has been associated with impaired neurodevelopmental outcome. Surgical PDA closure may result in abrupt changes of cerebral haemodynamics. OBJECTIVE: To examine the cerebral blood volume changes occurring after surgical closure of PDA. DESIGN: Continuous cerebral near-infrared spectroscopy (NIRS) recording throughout PDA surgery. SETTING: Tertiary neonatal intensive care unit, with PDA surgery performed on the ward. PATIENTS: Ten VLBW infants, median birth weight 748 g (range 590-1070), gestational age 24 (23-27) weeks, chronological age 14 (12-22) days. INTERVENTION: Surgical closure of PDA. MAIN OUTCOME MEASURES: Changes in cerebral oxygenated haemoglobin, cerebral deoxygenated haemoglobin, and tissue oxygenation index (measured), changes in cerebral blood volume (CBV) and cerebral haemoglobin difference (calculated) as measured by NIRS. RESULTS: During the first 2 minutes after closure of the PDA, CBV increased significantly (mean (SD) 0.14 (0.12) ml/100 g tissue; p = 0.01) and returned to baseline within 2-5 minutes. Cerebral oxygenation did not change. CONCLUSIONS: There is a short-lasting increase in CBV immediately after surgical closure of PDA, but no change in cerebral oxygenation. These transient changes are unlikely to cause harm.


Assuntos
Volume Sanguíneo/fisiologia , Encéfalo/irrigação sanguínea , Permeabilidade do Canal Arterial/fisiopatologia , Hemoglobinas/metabolismo , Oxigênio/sangue , Circulação Cerebrovascular/fisiologia , Permeabilidade do Canal Arterial/metabolismo , Permeabilidade do Canal Arterial/cirurgia , Frequência Cardíaca , Humanos , Recém-Nascido , Recém-Nascido de muito Baixo Peso/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho
7.
Z Kardiol ; 93(3): 194-200, 2004 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-15024586

RESUMO

The development of aortic regurgitation (AI) is a rare but serious complication of subaortic ventricular septal defects (VSD). Over a period of 5 years we observed VSD-related AI in 24 patients, a frequency of 4.5% of all isolated VSD's encountered during that time frame. The location of the defects was in the infundibular septum in 59%, it was perimembranous in 25% and in the trabecular septum in 16%. Hemodynamically the defects were small except for 2 where the Q(p)/Q(s) ratio was > 2. Of the 24 pts, 16 had surgical closure of their VSD accompanied in 9 by aortic valvuloplasty. AI was caused by elongation or defect of the right coronary leaflet in 42%, of the noncoronary leaflet in 25% and a combination of both, in 8%. In 6 pts with infundibular VSD absence of part of the aortic valve ring above the defect was the underlying mechanism for AI. Postoperatively AI was improved to moderate in one pt and to none to trivial in 15. LV end-diastolic diameter decreased significantly in all pts operated. Pathogenetic mechanisms for the development of AI are a deficiency in the aorto-infundibular junction with prolaps of the right-or non-coronary leaflet, deficiency of the valve supporting structures including the valve ring as well as suction of the already elongated leaflet into the VSD with further damage to the antiregurgitant mechanism of the semilunar valve at risk. In perimembranous VSD's, late AI is probably related to turbulent flow through the adjacent LVOT. Surgical closure of isolated VSD's with a location immediately beneath the aortic valve is indicated regardless of their size to prevent the development of AI. If AI has occurred, VSD closure including aortic valvuloplasty improves the amount of regurgitation and normalizes LV enddiastolic dimension.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Comunicação Interventricular/fisiopatologia , Adolescente , Adulto , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Volume Cardíaco/fisiologia , Criança , Pré-Escolar , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Comunicação Interventricular/cirurgia , Septos Cardíacos/fisiopatologia , Septos Cardíacos/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
8.
Pediatr Cardiol ; 24(3): 304-6, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12522653

RESUMO

Congenital absence of aortic cusps leads to severe aortic regurgitation. We present a newborn with this rare entity with extreme mitral stenosis. Hemodynamic features were those of hypoplastic left heart syndrome. Surgical management consisted of initial modified Norwood procedure followed by orthotopic heart transplantation.


Assuntos
Insuficiência da Valva Aórtica/congênito , Insuficiência da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Estenose da Valva Mitral/congênito , Estenose da Valva Mitral/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Transplante de Coração , Humanos , Recém-Nascido , Masculino , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico , Reoperação , Resultado do Tratamento
9.
Pediatr Cardiol ; 24(4): 397-9, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12399906

RESUMO

The absence of the right superior vena cava (SVC) is usually associated with the presence of a left SVC. This is the first report of a case of systemic venous return without the presence of either upper caval veins. The blood of the upper half of the body was collected into a vessel located on the left side of the spine behind the heart. This vessel crossed over to the right side at the level of the kidneys, draining directly into the inferior vena cava. During correction of tetralogy of Fallot, these findings were confirmed. The terminology and the bearing on interventional planning are discussed.


Assuntos
Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Veia Cava Superior/anormalidades , Anormalidades Múltiplas/diagnóstico , Anormalidades Múltiplas/cirurgia , Angiografia/métodos , Cateterismo Cardíaco/métodos , Ponte Cardiopulmonar/métodos , Ecocardiografia Doppler , Eletrocardiografia , Seguimentos , Hemodinâmica/fisiologia , Humanos , Lactente , Masculino , Medição de Risco , Resultado do Tratamento
10.
Thorac Cardiovasc Surg ; 50(6): 347-50, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12457311

RESUMO

BACKGROUND: Gene therapy in cardiovascular disease promises to be of great impact. The ideal vector for the therapeutic gene transfection remains to be determined. The aim of the present study was to investigate the efficacy of gene transfer using adeno-associated virus vectors carrying the lacZ-reporter gene (AAV-lacZ) in a previously described coronary recirculation model. METHODS: Beating Lewis rat hearts perfused with oxygenated Krebs-Henseleit solution were harvested, after which an atrial septal defect (ASD) was created. All vessels were tied, and AAV-lacZ was injected into the aortic root. The solution was recirculated through the ASD to the left side of the heart and pumped back to the coronary arteries by the left ventricle. Incubation was allowed for 20 min at 15 degrees C, and the hearts were subsequently transplanted heterotopically in syngeneic rats. Three increasing doses (109, 1,010, 1,011 e. u.) of AAV-lacZ virus vectors were used to study the rate of gene transfer. All hearts were harvested after 7-60 days and evaluated histologically for expression of the lacZ-gene. RESULTS: Dose-dependent gene transfer was observed. Even after 60 days, there was no obvious decline in gene expression. CONCLUSION: Adeno-associated virus vectors offer effective and uniform gene transfer in the myocardium after transcoronary injection and recirculation. Due to the lack of immune response previously described, no decrease in gene expression can be observed up to 60 days after injection.


Assuntos
Dependovirus/genética , Expressão Gênica , Terapia Genética/métodos , Cardiopatias/terapia , Animais , Soluções Cardioplégicas/metabolismo , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Técnicas de Transferência de Genes , Genes Reporter , Cardiopatias/genética , Transplante de Coração , Óperon Lac , Masculino , Miocárdio/metabolismo , Ratos , Ratos Endogâmicos Lew
11.
Circulation ; 104(15): 1757-60, 2001 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-11591610

RESUMO

BACKGROUND: The overall performance of available mechanical intravascular ultrasound catheters for fetal transesophageal echocardiography during fetoscopic fetal cardiac interventions in sheep has been limited by radioelectronic interference, low system frame rates, and low acoustic outputs. Therefore, a more reliable device is desired for human fetoscopic surgical procedures. METHODS AND RESULTS: We assessed the potential of a newly available 10-French phased-array intravascular ultrasound catheter for multimodal fetal transesophageal echocardiography in 5 fetal sheep between 78 and 98 days of gestation (term, 145 to 150 d). The intravascular ultrasound catheter was easily inserted through the mouth into the esophagus in all 5 sheep fetuses (mean weight, 600 g), and it permitted high-quality 2D imaging of the fetal heart in vertical imaging planes that were validated by MRI. Color Doppler and pulsed Doppler imaging permitted clear assessment of fetal cardiovascular flows and recording of velocity-time integral tracings of the fetal heart and great vessels. The vertical imaging planes were particularly useful to demonstrate interventional material inside the fetal heart and great vessels. CONCLUSIONS: Our early experience with the phased-array intravascular ultrasound catheter indicates that multimodal fetal transesophageal echocardiography has now become possible in these smallest of patients.


Assuntos
Cateterismo/instrumentação , Ecocardiografia Transesofagiana/métodos , Coração Fetal/diagnóstico por imagem , Feto , Ultrassonografia Pré-Natal/métodos , Animais , Ecocardiografia Doppler/instrumentação , Ecocardiografia Doppler/métodos , Ecocardiografia Transesofagiana/instrumentação , Feminino , Imageamento por Ressonância Magnética , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Doppler em Cores/instrumentação , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia Pré-Natal/instrumentação
12.
Basic Res Cardiol ; 96(3): 251-7, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11403418

RESUMO

BACKGROUND: Fetal tachyarrhythmias are usually of supraventricular origin. To investigate whether specific electrophysiologic properties of the fetal heart contribute to this preponderance by either favoring supraventricular tachycardias or by rendering ventricular tachycardias unlikely, we measured fetal electrophysiologic parameters in utero using transuterine fetal transesophageal electrocardiograms in fetal sheep. Since overdrive pacing may help to establish the mechanism of an arrhythmia and may be used to treat fetal tachycardias, different modes of transesophageal pacing in utero were also assessed. METHODS AND RESULTS: Decapolar electrophysiology catheters were fetoscopically inserted into the esophagus of 9 fetal sheep (pregnancy duration 94- 105 days, term = 145 days). Electrocardiograms were recorded simultaneously from all adjacent bipoles and from two pacing wires sutured onto the fetal shoulders. Pacing was attempted either via two adjacent electrodes of the intraesophageal catheter or via the most distal and most proximal electrode. Fetal cycle length, PQ, and QT intervals were close to (approx. 75 %), but fetal QRS duration was < 20 % of maternal values, thus shifting the relation between activation and repolarization towards longer excitation wave lengths. Fetal QT dispersion was small (< or = 10 ms). Atrial pacing was achieved in all fetuses using distant electrodes, and with lower thresholds when compared to closely spaced bipolar electrodes (p < 0.05). CONCLUSIONS: (I) An altered relation between ventricular activation and repolarization and a low dispersion of ventricular repolarization may protect the fetal heart against ventricular reentrant tachycardias. (II) Relatively normal fetal AV nodal conduction delay already provides one of the prerequisites for supraventricular reentrant tachycardias involving the AV node at this stage of fetal development. (III) High-rate esophageal pacing of the fetal atria is best achieved using widely spaced bipolar pacing electrodes.


Assuntos
Nó Atrioventricular/embriologia , Eletrofisiologia , Coração Fetal/embriologia , Ventrículos do Coração/embriologia , Útero/embriologia , Animais , Sistema Cardiovascular/embriologia , Eletrocardiografia , Desenvolvimento Embrionário e Fetal/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Modelos Animais , Modelos Cardiovasculares , Gravidez , Ovinos
14.
Circulation ; 102(14): 1602-4, 2000 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-11015334

RESUMO

BACKGROUND: Fetal cardiac interventions by direct ultrasound-guided approaches or open fetal cardiac surgery have been fraught with technical difficulties, as well as with significant maternal and fetal morbidity in humans. Therefore, the purpose of our study in sheep was to assess the feasibility and potential of fetoscopic direct fetal cardiac access. METHODS AND RESULTS: In 15 anesthetized pregnant ewes (88 to 109 days of gestation; term, 145 days), 3 to 4 trocars were percutaneously placed in the uterus. Using videofetoscopic equipment, we assessed the feasibility of achieving direct fetal cardiac access. Minimally invasive direct fetal cardiac access by operative fetoscopy was achieved in 10 of the 15 fetal sheep. In 7 fetuses, the approach was successfully tested for fetal cardiac pacing (n=5) or antegrade fetal cardiac catheterization (n=2). Access was not achieved in 5 fetuses because of bleeding complications (n=2) or because the fetoscopic setup could not be established (n=3). All but 2 fetal sheep were alive at the end of the procedure. Acute fetal demise resulted from maternal hypotension or kinking of the fetal inferior caval vein by sternal suspension. Six ewes continued gestation; 3 of these went to term, with a normal fetal outcome. Two ewes died from septicemia 3 and 7 days after the procedure, and 1 ewe aborted 1 month after the procedure. CONCLUSIONS: Minimally invasive direct fetal cardiac access by operative fetoscopy is feasible in fetal sheep. The fetoscopic approach carries important potential for fetal cardiac pacing, antegrade fetal valvuloplasties, and resection of fetal intrapericardial teratomas in human fetuses.


Assuntos
Coração Fetal/cirurgia , Fetoscopia/métodos , Animais , Cateterismo , Estudos de Viabilidade , Feminino , Ovinos
15.
Ann Thorac Surg ; 70(2): 538-41, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10969676

RESUMO

BACKGROUND: Wound necrosis and infection pose a tremendous risk for patients with left ventricular assist devices. METHODS: We analyzed our database of patients with left ventricular assist devices for those who developed wound dehiscence and concomitant infection after left ventricular assist device implantation. RESULTS: Three of our 66 patients (4.5%) with implantable ventricular assist devices had had severe wound complications with necrosis of the abdominal or thoracic wall uncovering part of the device. The predominant impact on the development of these complications was presumably related to multiple surgical interventions on the same site. CONCLUSIONS: Nevertheless, these patients can recover and undergo successful heart transplantation if adequately managed.


Assuntos
Coração Auxiliar , Deiscência da Ferida Operatória/etiologia , Infecção da Ferida Cirúrgica/etiologia , Músculos Abdominais/patologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Fatores de Risco
16.
Surg Endosc ; 14(5): 424-30, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10858464

RESUMO

BACKGROUND: Recent efforts to develop procedures for fetoscopic fetal cardiac interventions have been prompted by the development of severe secondary damage to the fetal heart due to semilunar valvar obstructions and the poor outcome of therapy-refractory fetal arrhythmias. The purpose of our manuscript is to analyze and share our experience with the creation of an operative setup for these procedures in sheep. METHODS: We studied a total of 48 fetal sheep between 81 and 106 days of gestation (term, 145 days). After entering the amniotic cavity by a percutaneous approach, we performed various fetoscopic fetal cardiac procedures. We analyzed the success of percutaneous fetal access, methods of trocar support, the incidence and management of trocar dislodgement or accidental insertion into the chorioamniotic space, problems related to amniotic insufflation and trocar placement, as well as techniques for fetal posturing and uterine closure. RESULTS: Percutaneous fetal access was achieved in all sheep. The use of resterilizable trocars substantially decreased the costs of our procedures. Utilizing a percutaneous transuterine purse-string suture for trocar support helped to minimize the number of nonabsorbable T-fasteners remaining inside the uterus postoperatively. As complications such as trocar dislodgement, insertion of the trocar into the chorioamniotic space, and problems with intraamniotic insufflation and gas loss were mastered, conversion to an open operative approach was never required. A novel strategy that we devised for percutaneous fetal posturing permitted adequate fetal posturing with ease and minimal trauma to the fetal skin. CONCLUSION: As operative techniques have become more refined, the feasibility of performing fetoscopic fetal cardiac interventions in human fetuses now depends mainly on technical improvements in imaging and interventional catheters, as well as advances in pacemaker equipment.


Assuntos
Coração Fetal/cirurgia , Fetoscopia/métodos , Animais , Feminino , Insuflação , Postura , Ovinos , Útero/cirurgia
17.
Thorac Cardiovasc Surg ; 47(5): 311-6, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10599959

RESUMO

BACKGROUND: Gene therapy promises to play an important role in the treatment of heart disease and in transplantation. The limited effectiveness of gene transfer, however, remains an unresolved problem. The aim of the study was to create a model for more effective gene transfer using adenovirus vectors carrying the lacZ-reporter gene (AdV-lacZ). METHODS: Beating Lewis rat hearts perfused with oxygenated Krebs-Henseleit solution were harvested, after which an atrial septal defect (ASD) was created. All vessels were tied and AdV-lacZ was injected into the aortic root. The solution was recirculated through the ASD to the left side of the heart and pumped back to the coronary arteries by the left ventricle. Incubation was allowed for 20 min at 15 degrees C and the hearts were subsequently transplanted heterotopically in syngeneic rats. This method was compared to AdV-lacZ injection into cardioplegic hearts. The hearts were harvested after 2, 7, or 14 days and evaluated histologically for expression of the lacZ gene. RESULTS: Maximal gene expression was achieved after 7 days by the recirculation model. There was less efficient gene expression at day 2 and at day 14. No evidence of ischemic injury of the myocardium was noticed histologically. Almost no successful gene expression was seen in the arrested hearts. CONCLUSION: This novel recirculation method lets the vector be repeatedly exposed to the endothelium, resulting in an effective gene expression after 7 days incubation time rather than after 14, when a decline has set in presumably due to immunologic response.


Assuntos
Adenoviridae/genética , Expressão Gênica , Técnicas de Transferência de Genes , Genes Reporter , Transplante de Coração/fisiologia , Óperon Lac , beta-Galactosidase/genética , Animais , Soluções Cardioplégicas , Terapia Genética/métodos , Vetores Genéticos , Glucose , Masculino , Miocárdio/metabolismo , Ratos , Ratos Endogâmicos Lew , Trometamina
18.
J Heart Lung Transplant ; 18(10): 927-36, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10561102

RESUMO

BACKGROUND: The widely used non-volume-loaded abdominal heterotopic heart transplant (NL) in rats undergoes atrophy after transplantation. Various techniques have been designed to load the transplanted heart because of its potential immunological impact. Our aim was to create a volume-loaded heterotopic heart transplantation model (VL) capable of ejection and practical for routine studies. Using this model, we tested the hypothesis that VL isografts would retain myocardial performance comparable to native hearts (NH). METHODS: Heterotopic hearts were transplanted using and end-to-side anastomosis between the donor's superior vena cava and the recipient's abdominal inferior vena cava. The right ventricle loads the left ventricle (LV) via a direct anastomosis of the pulmonary artery to the left atrium. The LV ejects volume through an end-to-side anastomosis of the donor's aorta to the recipient's abdominal aorta. Hemodynamic data (systolic and diastolic LV pressures, dP/dt max and min, tau) were studied in-situ (at baseline and after adding volume) and in a Langendorff perfusion system (at baseline and after stimulation with isoproterenol) 2 weeks after transplantation. RESULTS: In situ systolic pressure and diastolic function of VL was superior to NL, and beta-adrenergic stimulated performance in the Langendorff perfusion of VL showed hemodynamic performance equivalent to NH, unlike NL which had a diminished response. CONCLUSION: This technique results in a volume-loaded ejecting heart transplant model that preserves anatomical structures. The VL can be evaluated in situ and after explantation in Langendorff perfusion system and may offer advantages if workload of the graft is of significance to the study performed.


Assuntos
Transplante de Coração/fisiologia , Modelos Cardiovasculares , Transplante Heterotópico/fisiologia , Abdome , Análise de Variância , Anastomose Cirúrgica/métodos , Animais , Cardiotônicos/farmacologia , Eletrocardiografia/estatística & dados numéricos , Transplante de Coração/métodos , Transplante de Coração/estatística & dados numéricos , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Isoproterenol/farmacologia , Masculino , Ratos , Ratos Endogâmicos Lew , Técnicas de Sutura
19.
Circulation ; 100(7): 772-6, 1999 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-10449702

RESUMO

BACKGROUND: Therapy-refractory supraventricular tachycardia commonly results in hydrops and death in human fetuses. The purpose of this study in fetal sheep was to assess the feasibility of a minimally invasive fetoscopic approach for fetal transesophageal electrocardiography and stimulation aimed at diagnosis and termination of these tachycardias. METHODS AND RESULTS: We studied a total of 10 fetal sheep (87 to 103 days of gestation; term=145 days). We entered the amniotic cavity using a percutaneous fetoscopic approach and placed various electrophysiology catheters into the fetal esophagus. We recorded the number of animals in which fetoscopic transesophageal electrocardiography and stimulation were successful and assessed pacing success and thresholds for different catheters. In addition, we monitored for potential adverse effects from stimulation and for other complications of the operation. Recording of transesophageal electrocardiograms was successful in all fetal sheep. Capture during stimulation was successfully documented by additional fetal bipolar surface electrocardiograms in 7 fetuses. In fetuses in which fetal surface electrocardiograms were not recorded, pacing stimulus artifacts interfered with documentation of capture. Although stimulation thresholds were high, the maternal rhythm was not affected by fetal stimulation. CONCLUSIONS: Fetoscopic fetal transesophageal electrocardiography and stimulation are feasible in fetal sheep. This minimally invasive approach might have the potential to improve diagnosis and management of therapy-refractory supraventricular tachycardias in human fetuses.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia Transesofagiana/métodos , Doenças Fetais/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Taquicardia Supraventricular/diagnóstico por imagem , Animais , Estimulação Elétrica , Estudos de Viabilidade , Feminino , Fetoscopia , Ovinos/embriologia , Taquicardia Supraventricular/embriologia , Taquicardia Supraventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA