Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Diagn Interv Radiol ; 30(1): 3-8, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-37154817

RESUMO

PURPOSE: Preoperative evaluation of donor liver volume is indispensable in living donor liver transplantation to ensure sufficient residual liver and graft-to-recipient weight ratio. This study aims to evaluate the accuracy of two computed tomography (CT) volumetry programs, an interactive manual and a semi-automated one, in the preoperative estimation of the right lobe graft weight. METHODS: One hundred and nine right liver lobe living donors between January 2008 and January 2020 were enrolled in this retrospective study. Two radiologists measured the liver graft volumes independently using manual and semi-automated CT volumetry, and the interaction time was recorded. Actual graft weight (AGW) measured intraoperatively served as the reference standard. The paired samples t-test was used to compare the estimated graft weight (EGW) and the AGW. Inter-user and inter-method agreements were assessed with Bland-Altman plots. RESULTS: Both manual and semi-automated CT volumetry significantly overestimated the graft weight (EGW manual: 893 ± 155 mL vs. AGW manual: 787 ± 128 g, P < 0.001, EGW semi-automated: 879 ± 143 mL vs. AGW semi-automated, P < 0.001). The junior radiologist measured higher volumes than the senior radiologist with either method (P < 0.001). The Bland-Altman analysis revealed mean difference and standard deviation for inter-method agreement of 7 ± 48 cc for the senior radiologist, and 34 ± 54 cc for the junior radiologist. The mean difference and standard deviation for inter-method agreement was 63 ± 59 cc in manual volumetry and 22 ± 38 cc in semi-automated volumetry. The mean interaction time was 27.3 ± 14.2 min for manual volumetry and 6.8 ± 1.4 min for semi-automated volumetry (P < 0.001). CONCLUSION: Both manual and semi-automated CT volumetry significantly overestimated the right liver graft weight, while semi-automated volumetry significantly reduced the interaction time.


Assuntos
Transplante de Fígado , Adulto , Humanos , Doadores Vivos , Estudos Retrospectivos , Tamanho do Órgão , Fígado/diagnóstico por imagem , Fígado/cirurgia , Tomografia Computadorizada por Raios X/métodos
2.
Turk J Med Sci ; 48(6): 1162-1166, 2018 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-30541242

RESUMO

Background/aim: Solid organ transplant (SOT) recipients have increased risk of tuberculosis (TB). We aimed to investigate the prevalence and features of TB in liver transplant (LT) recipients at our transplantation canter. Materials and methods: All patients who underwent LT between January 2004 and December 2013 and whose data were accessible were included in the study. Demographic features, tuberculin skin test (TST) results, and TB prevalence were recorded. Characteristics of LT recipients who developed TB were evaluated. Results: A total of 403 patients underwent LT during this period. Mean age was 47.27 ± 11.04 years; 280 (69.47%) were males. The TST was administered to 108 (25.91%) and the QuantiFERON-TB test to 1 patient. TST positivity was determined in 28 (25.93%). Latent TB infection (LTBI) treatment was not recommended to any of the LT candidates. In the posttransplant period, 5 patients (1.24%) developed TB over a median duration of 14 (min: 7, max: 84) months, 2 of whom were found to have had LTBI in the pretransplant period. Conclusion: The prevalence of TB in LT recipients at our center was similar to that in the current literature. LTBI screening, including risk factor assessment and TST/QuantiFERON-TB testing, is necessary in the early diagnostic workup for TB in LT recipients.

SELEÇÃO DE REFERÊNCIAS