Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 327
Filtrar
1.
Transl Vis Sci Technol ; 13(7): 5, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38967936

RESUMO

Purpose: First- (monomers), second- (pre-gelated), and third- (in situ gelating after injection) generation hydrogels were previously introduced to replace the vitreous body after vitrectomy surgery. In this study, we evaluated the surgical, optical, and viscoelastic properties of vitreous body replacement hydrogels before and after an accelerated aging protocol previously applied to intraocular implants. Methods: Measurements of injection force, removal speed using a clinically established vitrectomy setup, as well as evaluation of forward light scattering and viscoelastic properties before and after an accelerated aging protocol were conducted. Results were compared to porcine and human vitreous bodies, as well as currently clinically applied lighter- and heavier-than-water silicone oils. Results: Removal speed of all tested hydrogels is substantially lower than the removal speed of porcine vitreous body (0.2 g/min vs. 2.7 g/min for the best performing hydrogel and porcine vitreous body, respectively). Forward light scattering in second-generation vitreous body replacement hydrogels was higher after the aging process than the straylight of the average 70-year-old vitreous body (9.4 vs. 5.5 deg2/sr, respectively). The viscoelastic properties of all hydrogels did not change in a clinically meaningful manner; however, trends toward greater stiffness and greater elasticity after aging were apparent. Conclusions: This study demonstrates surgical weaknesses of the hydrogels that need to be addressed before clinical use, especially low removal speed. Pre-linked hydrogels (second-generation) showed inferior performance regarding surgical properties compared to in situ gelating hydrogels (third-generation). Translational Relevance: This study highlights possible pitfalls regarding surgical and optical properties when applying vitreous replacement hydrogels clinically.


Assuntos
Hidrogéis , Óleos de Silicone , Vitrectomia , Corpo Vítreo , Corpo Vítreo/cirurgia , Animais , Hidrogéis/química , Óleos de Silicone/química , Suínos , Vitrectomia/métodos , Viscosidade , Humanos , Elasticidade , Idoso , Envelhecimento/fisiologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-38884654

RESUMO

PURPOSE: To evaluate the biomechanical and tomographic outcomes of keratoconus patients up to four years after corneal crosslinking (CXL). METHODS: In this longitudinal retrospective-prospective single-center case series, the preoperative tomographic and biomechanical results from 200 keratoconus eyes of 161 patients undergoing CXL were compared to follow-up examinations at three-months, six-months, one-year, two-years, three-years, and four-years after CXL. Primary outcomes included the Corvis Biomechanical Factor (CBiF) and five biomechanical response parameters obtained from the Corvis ST. Tomographically, the Belin-Ambrósio deviation index (BAD-D) and the maximal keratometry (Kmax) measured by the Pentacam were analyzed. Additionally, Corvis E-staging, the thinnest corneal thickness (TCT), and the best-corrected visual acuity (BCVA) were obtained. Primary outcomes were compared using a paired t-test. RESULTS: The CBiF decreased significantly at the six-month (p < 0.001) and one-year (p < 0.001) follow-ups when compared to preoperative values. E-staging behaved accordingly to the CBiF. Within the two- to four-year follow-ups, the biomechanical outcomes showed no significant differences when compared to preoperative. Tomographically, the BAD-D increased significantly during the first year after CXL with a maximum at six-months (p < 0.001), while Kmax decreased significantly (p < 0.001) and continuously up to four years after CXL. The TCT was lower at all postoperative follow-up visits compared to preoperative, and the BCVA improved. CONCLUSION: In the first year after CXL, there was a temporary progression in both the biomechanical CBiF and E-staging, as well as in the tomographic analysis. CXL contributes to the stabilization of both the tomographic and biomechanical properties of the cornea up to four years postoperatively.

5.
Diagnostics (Basel) ; 14(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38893624

RESUMO

BACKGROUND: To clinically evaluate how dry eye symptoms in preoperatively diagnosed dry eye patients change with the use of sodium hyaluronate- and dexpanthenol-containing eye drops (HYLO CARE (HC), URSAPHARM Arzneimittel GmbH, Saarbruecken, Germany) after cataract surgery. The aim of the study was not to compare different eye drops but to implement standard treatment in patients with dry eye undergoing cataract surgery. The impact of treatment was evaluated using Symptom Assessment Tools for Dry Eye. METHODS: In this prospective, single-center, open-label clinical trial, 49 patients undergoing cataract surgery were included who showed signs and symptoms of dry eye disease assessed by the Symptom Assessment in Dry Eye (Visual Analogue Scale (VAS)) questionnaire, Ocular Surface Disease Index (OSDI), and fluorescein tear break-up Time (TBUT). Patients were instructed to apply HC three to four times a day for 5 weeks in the operated eye in addition to the standard postoperative topical anti-inflammatory regimen. The primary endpoint was the change in TBUT. Secondary endpoints were the assessment of the subjective symptoms (VAS), corrected distance visual acuity (CDVA), and slit-lamp examination including the corneal staining score, Schirmer test, and intraocular pressure. RESULTS: At 5 weeks after operation, the mean TBUT increased from 6.42 ± 1.57 s (s) to 7.81 ± 1.83 s in the per-protocol (PP) population (p > 0.001) and from 6.33 ± 1.64 s to 7.71 ± 2.05 s in the intention-to-treat (ITT) population (p < 0.001). There was a statistically significant decrease in all scores (p < 0.05) from the VAS questionnaire except for the tearing score (p = 0.062) at 5 weeks after operation. The mean total corneal staining score also decreased statistically significantly from 8.85 ± 2.49 before operation to 5.61 ± 3.37 at 5 weeks after operation on a 15-point scale. CONCLUSIONS: Controlled standardized dry eye treatment (with HC) improved tear film stability, ocular surface defects, and subjective symptoms of dry eye disease in patients 5 weeks after undergoing cataract surgery. Both the patient and physician assessments indicated high efficacy, tolerability, and a reliable safety profile, as indicated by the low number of at least possibly related adverse events (AE), suggesting its beneficial role in the postoperative management of the ocular surface (OS) in patients with dry eye symptoms prior to and after cataract surgery.

6.
Am J Ophthalmol Case Rep ; 35: 102080, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38827999

RESUMO

Introduction: Calcification of hydrophilic intraocular lenses (IOL) is a rare complication following cataract surgery. Secondary calcification is described as due to host factors or changes in the IOL environment and uveitis, proliferative diabetic retinopathy and sequelae of ocular surgery are recognised potentiators. The impact of systemic connective tissue disease on IOL opacification is yet to described. Purpose: To describe the clinical presentation and management of a young patient, with a rare subtype of Ehlers-Danlos syndrome, who presented with secondary IOL calcification 14 years after primary IOL insertion. Observations: Floret-like lesions were observed on the IOL surface. Positive staining for calcification was observed with Alizarin red and von Kossa method on laboratory analysis. Conclusions and importance: Patients with systemic connective tissue disease, such as a subtype of Ehlers-Danlos, may present with secondary IOL calcification many years after primary lens insertion. This poses an additional consideration when implanting IOLs in these patients.Good visual acuity can be achieved with IOL exchange.

7.
J Ophthalmol ; 2024: 2360368, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38846928

RESUMO

Purpose: To assess the nozzle tip damage and the parameters of three different hydrophilic intraocular lens (IOL) injector models. Methods: After routine cataract surgeries at the University Eye Hospital Heidelberg, all the used IOL injectors were collected from the operating room and sent to our laboratory. Nozzle tip damage was assessed under a microscope and graded as follows: no damage (grade 0), slight scratches (1), deep scratches (2), extensions (3), cracks (4), and bursts (5). Each damage grade was assigned a score from 0 to 5, and the total damage score for each injector system was calculated and compared. Nozzle tip parameters (diameters and areas), plunger tip parameters, and tip angles were also measured in each model. Results: The damage scores were (median, Q3-Q1): 1 (1-1) for Accuject, 1 (1-1) for Bluemixs, and 1 (1-1) for RayOne. There was no statistically significant difference in the damage scores between the study groups (P > 0.05). The outer cross-sectional vertical and horizontal diameters were 1.69 and 1.69 mm for Accuject, 1.69 and 1.69 mm for Bluemixs, and 1.70 and 1.71 mm for RayOne. Plunger tip areas were 0.78 mm2 for Accjuect, 0.74 mm2 for Bluemixs, and 0.43 mm2 for RayOne. Plunger tip area/inner cross-sectional area of the nozzle tip (%) was 31.2% for RayOne, 66.7% for Accuject, and 63.8% for Bluemixs. The tip angles for three injector models were 56° (Accuject), 56° (Bluemixs), and 44° (RayOne). Conclusions: All the injector models showed mild to moderate damage to the nozzle tip after IOL implantation, even with smaller diameter tips. RayOne resulted in the lowest ratio between plunger tip area and inner cross-sectional area of the nozzle tip and a better distribution of damage categories than the other two groups. All three injector models had relatively small tip parameters. If smaller incisions are required in certain patients, smaller tip parameters should be considered.

9.
Ophthalmologie ; 2024 May 03.
Artigo em Alemão | MEDLINE | ID: mdl-38700761
11.
Int J Stroke ; : 17474930241248516, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38591748

RESUMO

RATIONALE: Meta-analyses of case series of non-arteritic central retinal artery occlusion (CRAO) indicate beneficial effects of intravenous thrombolysis when initiated early after symptom onset. Randomized data are lacking to address this question. AIMS: The REperfusion therapy with intravenous alteplase for recovery of VISION in acute central retinal artery occlusion (REVISION) investigates intravenous alteplase within 4.5 h of monocular vision loss due to acute CRAO. METHODS: This study is the randomized (1:1), double-blind, placebo-controlled, multicenter adaptive phase III trial. STUDY OUTCOMES: Primary outcome is functional recovery to normal or mildly impaired vision in the affected eye defined as best-corrected visual acuity of the Logarithm of the Minimum Angle of Resolution of 0.5 or less at 30 days (intention-to-treat analysis). Secondary efficacy outcomes include modified Rankin Score at 90 days and quality of life. Safety outcomes include symptomatic intracranial hemorrhage, major bleeding (International Society on Thrombosis and Haemostasis definition) and mortality. Exploratory analyses of optical coherence tomography/angiography, ultrasound and magnetic resonance imaging (MRI) biomarkers will be conducted. SAMPLE SIZE: Using an adaptive design with interim analysis at 120 patients, up to 422 participants (211 per arm) would be needed for 80% power (one-sided alpha = 0.025) to detect a difference of 15%, assuming functional recovery rates of 10% in the placebo arm and 25% in the alteplase arm. DISCUSSION: By enrolling patients within 4.5 h of CRAO onset, REVISION uses insights from meta-analyses of CRAO case series and randomized thrombolysis trials in acute ischemic stroke. Increased rates of early reperfusion and good neurological outcomes in stroke may translate to CRAO with its similar pathophysiology. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04965038; EU Trial Number: 2023-507388-21-00.

15.
Invest Ophthalmol Vis Sci ; 65(3): 36, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38551585

RESUMO

Purpose: Symptomatic vitreous opacifications, so-called floaters, are difficult to objectively assess majorly limiting the possibility of in vitro studies. Forward light scattering was found previously to be increased in eyes with symptomatic floaters. Using an objective setup to measure forward light scattering, we studied the effects of enzymatically digesting the components of the vitreous body on straylight to develop an in vitro model of vitreous opacifications. Methods: Fifty-seven porcine vitreous bodies were digested using hyaluronidase, collagenase, trypsin, and bromelain, as well as using a combination of hyaluronidase + collagenase and hyaluronidase + bromelain. A modified C-Quant setup was used to objectively assess forward light scattering. Results: Depletion of hyaluronic acid majorly increased vitreous straylight (mean increase 34.4 deg2/sr; P = 0.01), whereas primarily digesting the vitreous gel with collagenase or trypsin did not significantly affect straylight. When collagenase or bromelain is applied in hyaluronic acid depleted vitreous gels, the increase in forward light scattering is reversed partially. Conclusions: The age-related loss of hyaluronic acid primarily drives the increase in vitreous gel straylight induced by conglomerates of collagen. This process can be reversed partially by digesting collagen. This in vitro model allows the objective quantification and statistical comparison of straylight burden caused by vitreous opacities and, thus, can serve as a first testing ground for pharmacological therapies, as demonstrated with bromelain.


Assuntos
Bromelaínas , Luz , Animais , Suínos , Hialuronoglucosaminidase/farmacologia , Ácido Hialurônico/farmacologia , Tripsina , Envelhecimento , Colágeno/farmacologia , Colagenases/farmacologia , Espalhamento de Radiação
16.
Cornea ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478752

RESUMO

PURPOSE: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). METHODS: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambrósio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. RESULTS: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. CONCLUSIONS: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.

17.
J Mech Behav Biomed Mater ; 152: 106368, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340476

RESUMO

PURPOSE: To describe and analyse the particularities of the material and the optical quality of the first intraocular lens (IOL) (Eyedeal® lens) made of crosslinked polyisobutylene (xPIB). METHODS: We assessed the material quality using an accelerated ageing process (to provoke glistenings) and compared values with a control, AcrySof® lens. Using the sessile drop method, the contact angle of the new IOL was measured. Images of the lens surface were recorded by scanning electron microscopy (SEM). Optical quality was assessed by measuring the labeled power and modulation transfer function (MTF) using standard metrology equipment (OptiSpheric IOL PRO2). RESULTS: The Eyedeal® lens had an average glistening density result of 7.46 ± 3.78 MV/mm2 compared to the control AcrySof® whose glistenings number was 142.42 ± 72.47 MV/mm2. The contact angle was 97.2° whereas the angle of AcrySof material is between 73.3 ± 2.4° and 84.4 ± 0.1°. Using SEM, Eyedeal® lenses were examined and all appeared to be comparable to modern IOLs made of acrylic materials. The power and MTF values were normal and conformed to ISO standards. CONCLUSIONS: In the laboratory, the new Eyedeal® lens showed equivalence to current hydrophobic- or hydrophilic-acrylic lens models. It showed superiority in its glistening density result compared to the control lens.


Assuntos
Lentes Intraoculares , Polímeros , Polienos , Laboratórios , Microscopia Eletrônica de Varredura
18.
Int Ophthalmol ; 44(1): 52, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340212

RESUMO

PURPOSE: To evaluate the initial visual outcomes of Small Incision Lenticule Extraction (SMILE) Pro® using a 2 MHz femtosecond laser (VisuMax 800, Carl Zeiss Meditec) and to assess the efficacy, safety, predictability, accuracy, and complication rate. METHODS: This retrospective analysis included eyes which underwent the SMILE Pro® procedure using VisuMax 800 femtosecond laser to correct myopia. All surgeries were performed by one surgeon (DB). Follow-up was conducted 3 months postoperatively to evaluate visual outcomes after neuroadaptation, corrected visual acuity (CDVA) and intra- and postoperative complications. RESULTS: One hundred and fifty-two eyes of 82 patients (mean age 31 ± 6 years) results at 3 months are presented. The mean spherical equivalent (SE) was - 4.44 ± 1.86 D preoperatively while -0.24 ± 0.32 D postoperatively. 99% of eyes achieved SE within ± 1.0 D of attempted correction and 91% were within ± 0.5 D. Efficacy index was 0.93 while the safety index was 1. No complications occurred intra- or postoperatively. No eyes lost more than 1 line of their preoperative CDVA. All highly myopic eyes (- 6.25 to - 10.00 D; n = 18) achieved 20/20 at 3 months postoperatively and were within 0.5 D from the attempted SE and no eyes lost more than 1 line of CDVA. CONCLUSION: The SMILE Pro® is a safe, efficient, and predictable procedure for the treatment of myopia and myopic astigmatism, with comparable results of conventional SMILE surgery. High myopic eyes achieve better results than low and moderate myopia. No complications were recorded in our patients.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Adulto , Acuidade Visual , Estudos Retrospectivos , Refração Ocular , Córnea/cirurgia , Substância Própria/cirurgia , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
19.
J Refract Surg ; 40(2): e79-e88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346120

RESUMO

PURPOSE: To investigate the optical performance and tolerance to misalignment of blue-light filtering monofocal intraocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5-mm pupils. In addition, each IOL's tolerance to misalignment was examined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested using a 3-mm aperture and an SA-neutral corneal model, indicated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic aberration, the CT Lucia 621 PY maintained its minimally better performance. When assessed with a 4.5-mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration-free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal simulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, displaying a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79-e88.].


Assuntos
Lentes Intraoculares , Humanos , Visão Ocular , Acuidade Visual , Pupila , Luz Azul , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA