Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Cardiovasc Magn Reson ; 24(1): 23, 2022 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-35369885

RESUMO

BACKGROUND: While multiple cardiovascular magnetic resonance (CMR) methods provide excellent reproducibility of global circumferential and global longitudinal strain, achieving highly reproducible segmental strain is more challenging. Previous single-center studies have demonstrated excellent reproducibility of displacement encoding with stimulated echoes (DENSE) segmental circumferential strain. The present study evaluated the reproducibility of DENSE for measurement of whole-slice or global circumferential (Ecc), longitudinal (Ell) and radial (Err) strain, torsion, and segmental Ecc at multiple centers. METHODS: Six centers participated and a total of 81 subjects were studied, including 60 healthy subjects and 21 patients with various types of heart disease. CMR utilized 3 T scanners, and cine DENSE images were acquired in three short-axis planes and in the four-chamber long-axis view. During one imaging session, each subject underwent two separate DENSE scans to assess inter-scan reproducibility. Each subject was taken out of the scanner and repositioned between the scans. Intra-user, inter-user-same-site, inter-user-different-site, and inter-user-Human-Deep-Learning (DL) comparisons assessed the reproducibility of different users analyzing the same data. Inter-scan comparisons assessed the reproducibility of DENSE from scan to scan. The reproducibility of whole-slice or global Ecc, Ell and Err, torsion, and segmental Ecc were quantified using Bland-Altman analysis, the coefficient of variation (CV), and the intraclass correlation coefficient (ICC). CV was considered excellent for CV ≤ 10%, good for 10% < CV ≤ 20%, fair for 20% < CV ≤ 40%, and poor for CV > 40. ICC values were considered excellent for ICC > 0.74, good for ICC 0.6 < ICC ≤ 0.74, fair for ICC 0.4 < ICC ≤ 0.59, poor for ICC < 0.4. RESULTS: Based on CV and ICC, segmental Ecc provided excellent intra-user, inter-user-same-site, inter-user-different-site, inter-user-Human-DL reproducibility and good-excellent inter-scan reproducibility. Whole-slice Ecc and global Ell provided excellent intra-user, inter-user-same-site, inter-user-different-site, inter-user-Human-DL and inter-scan reproducibility. The reproducibility of torsion was good-excellent for all comparisons. For whole-slice Err, CV was in the fair-good range, and ICC was in the good-excellent range. CONCLUSIONS: Multicenter data show that 3 T CMR DENSE provides highly reproducible whole-slice and segmental Ecc, global Ell, and torsion measurements in healthy subjects and heart disease patients.


Assuntos
Cardiopatias , Imagem Cinética por Ressonância Magnética , Voluntários Saudáveis , Cardiopatias/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
2.
JACC Cardiovasc Imaging ; 14(12): 2369-2383, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34419391

RESUMO

OBJECTIVES: The objective was to determine the feasibility and effectiveness of cardiac magnetic resonance (CMR) cine and strain imaging before and after cardiac resynchronization therapy (CRT) for assessment of response and the optimal resynchronization pacing strategy. BACKGROUND: CMR with cardiac implantable electronic devices can safely provide high-quality right ventricular/left ventricular (LV) ejection fraction (RVEF/LVEF) assessments and strain. METHODS: CMR with cine imaging, displacement encoding with stimulated echoes for the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) dyssynchrony parameter, and scar assessment was performed before and after CRT. Whereas the pre-CRT scan constituted a single "imaging set" with complete volumetric, strain, and scar imaging, multiple imaging sets with complete strain and volumetric data were obtained during the post-CRT scan for biventricular pacing (BIVP), LV pacing (LVP), and asynchronous atrial pacing modes by reprogramming the device outside the scanner between imaging sets. RESULTS: 100 CMRs with a total of 162 imaging sets were performed in 50 patients (median age 70 years [IQR: 50-86 years]; 48% female). Reduction in LV end-diastolic volumes (P = 0.002) independent of CRT pacing were more prominent than corresponding reductions in right ventricular end-diastolic volumes (P = 0.16). A clear dependence of the optimal CRT pacing mode (BIVP vs LVP) on the PR interval (P = 0.0006) was demonstrated. The LVEF and RVEF improved more with BIVP than LVP with PR intervals ≥240 milliseconds (P = 0.025 and P = 0.002, respectively); the optimal mode (BIVP vs LVP) was variable with PR intervals <240 milliseconds. A lower pre-CRT displacement encoding with stimulated echoes (DENSE) CURE-SVD was associated with greater improvements in the post-CRT CURE-SVD (r = -0.69; P < 0.001), LV end-systolic volume (r = -0.58; P < 0.001), and LVEF (r = -0.52; P < 0.001). CONCLUSIONS: CMR evaluation with assessment of multiple pacing modes during a single scan after CRT is feasible and provides useful information for patient care with respect to response and the optimal pacing strategy.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Magn Reson Med ; 86(4): 2105-2121, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34096083

RESUMO

PURPOSE: Myocardial strain is increasingly used to assess left ventricular (LV) function. Incorporation of LV deformation into finite element (FE) modeling environment with subsequent strain calculation will allow analysis to reach its full potential. We describe a new kinematic model-based analysis framework (KMAF) to calculate strain from 3D cine-DENSE (displacement encoding with stimulated echoes) MRI. METHODS: Cine-DENSE allows measurement of 3D myocardial displacement with high spatial accuracy. The KMAF framework uses cine cardiovascular magnetic resonance (CMR) to facilitate cine-DENSE segmentation, interpolates cine-DENSE displacement, and kinematically deforms an FE model to calculate strain. This framework was validated in an axially compressed gel phantom and applied in 10 healthy sheep and 5 sheep after myocardial infarction (MI). RESULTS: Excellent Bland-Altman agreement of peak circumferential (Ecc ) and longitudinal (Ell ) strain (mean difference = 0.021 ± 0.04 and -0.006 ± 0.03, respectively), was found between KMAF estimates and idealized FE simulation. Err had a mean difference of -0.014 but larger variation (±0.12). Cine-DENSE estimated end-systolic (ES) Ecc , Ell and Err exhibited significant spatial variation for healthy sheep. Displacement magnitude was reduced on average by 27%, 42%, and 56% after MI in the remote, adjacent and MI regions, respectively. CONCLUSIONS: The KMAF framework allows accurate calculation of 3D LV Ecc and Ell from cine-DENSE.


Assuntos
Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio , Animais , Fenômenos Biomecânicos , Infarto do Miocárdio/diagnóstico por imagem , Reprodutibilidade dos Testes , Ovinos , Função Ventricular Esquerda
4.
J Cardiovasc Magn Reson ; 23(1): 20, 2021 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-33691739

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) cine displacement encoding with stimulated echoes (DENSE) measures heart motion by encoding myocardial displacement into the signal phase, facilitating high accuracy and reproducibility of global and segmental myocardial strain and providing benefits in clinical performance. While conventional methods for strain analysis of DENSE images are faster than those for myocardial tagging, they still require manual user assistance. The present study developed and evaluated deep learning methods for fully-automatic DENSE strain analysis. METHODS: Convolutional neural networks (CNNs) were developed and trained to (a) identify the left-ventricular (LV) epicardial and endocardial borders, (b) identify the anterior right-ventricular (RV)-LV insertion point, and (c) perform phase unwrapping. Subsequent conventional automatic steps were employed to compute strain. The networks were trained using 12,415 short-axis DENSE images from 45 healthy subjects and 19 heart disease patients and were tested using 10,510 images from 25 healthy subjects and 19 patients. Each individual CNN was evaluated, and the end-to-end fully-automatic deep learning pipeline was compared to conventional user-assisted DENSE analysis using linear correlation and Bland Altman analysis of circumferential strain. RESULTS: LV myocardial segmentation U-Nets achieved a DICE similarity coefficient of 0.87 ± 0.04, a Hausdorff distance of 2.7 ± 1.0 pixels, and a mean surface distance of 0.41 ± 0.29 pixels in comparison with manual LV myocardial segmentation by an expert. The anterior RV-LV insertion point was detected within 1.38 ± 0.9 pixels compared to manually annotated data. The phase-unwrapping U-Net had similar or lower mean squared error vs. ground-truth data compared to the conventional path-following method for images with typical signal-to-noise ratio (SNR) or low SNR (p < 0.05), respectively. Bland-Altman analyses showed biases of 0.00 ± 0.03 and limits of agreement of - 0.04 to 0.05 or better for deep learning-based fully-automatic global and segmental end-systolic circumferential strain vs. conventional user-assisted methods. CONCLUSIONS: Deep learning enables fully-automatic global and segmental circumferential strain analysis of DENSE CMR providing excellent agreement with conventional user-assisted methods. Deep learning-based automatic strain analysis may facilitate greater clinical use of DENSE for the quantification of global and segmental strain in patients with cardiac disease.


Assuntos
Aprendizado Profundo , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Função Ventricular Direita , Automação , Estudos de Casos e Controles , Cardiopatias/fisiopatologia , Humanos , Londres , Valor Preditivo dos Testes , Estados Unidos
5.
J Magn Reson Imaging ; 52(6): 1722-1731, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32720405

RESUMO

BACKGROUND: Segmental extent of infarction assessed by late gadolinium enhancement (LGE) imaging early post-ST-segment elevation myocardial infarction (STEMI) has utility in predicting left ventricular functional recovery. HYPOTHESIS: We hypothesized that segmental circumferential strain with displacement encoding with stimulated echoes (DENSE) would be a stronger predictor of infarct transmurality than feature-tracking strain, and noninferior to extracellular volume fraction (ECV). STUDY TYPE: Prospective. POPULATION: Fifty participants (mean ± SD, 59 ± 9 years, 40 [80%] male) underwent cardiac MRI on day 1 post-STEMI. FIELD-STRENGTH/SEQUENCES: 1.5T/cine, DENSE, T1 mapping, ECV, LGE. ASSESSMENT: Two observers assessed segmental percentage LGE extent, presence of microvascular obstruction (MVO), circumferential and radial strain with DENSE and feature-tracking, T1 relaxation times, and ECV. STATISTICAL TESTS: Normality was tested using the Shapiro-Wilk test. Skewed distributions were analyzed utilizing Mann-Whitney or Kruskal-Wallis tests and normal distributed data using independent t-tests. Diagnostic cutoff values were identified using the Youden index. The difference in area under the curve was compared using the z-statistic. RESULTS: Segmental circumferential strain with DENSE was associated with the extent of infarction ≥50% (AUC [95% CI], cutoff value = 0.9 [0.8, 0.9], -10%) similar to ECV (AUC = 0.8 [0.8, 0.9], 37%) (P = 0.117) and superior to feature-tracking circumferential strain (AUC = 0.7[0.7, 0.8], -19%) (P < 0.05). For the detection of segmental infarction ≥75%, circumferential strain with DENSE (AUC = 0.9 [0.8, 0.9], -10%) was noninferior to ECV (AUC = 0.8 [0.7, 0.9], 42%) (P = 0.132) and superior to feature-tracking (AUC = 0.7 [0.7, 0.8], -13%) (P < 0.05). For MVO detection, circumferential strain with DENSE (AUC = 0.8 [0.8, 0.9], -12%) was superior to ECV (AUC = 0.8 [0.7, 0.8] 34%) (P < 0.05) and feature-tracking (AUC = 0.7 [0.6, 0.7] -21%) (P < 0.05). DATA CONCLUSION: Circumferential strain with DENSE is a functional measure of infarct severity and may remove the need for gadolinium contrast agents in some circumstances. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 5 J. MAGN. RESON. IMAGING 2020;52:1722-1731.


Assuntos
Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio , Meios de Contraste , Gadolínio , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Valor Preditivo dos Testes , Estudos Prospectivos , Função Ventricular Esquerda
6.
JACC Cardiovasc Imaging ; 13(4): 924-936, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31864974

RESUMO

OBJECTIVES: This study sought to determine if combining the Seattle Heart Failure Model (SHFM-D) and cardiac magnetic resonance (CMR) provides complementary prognostic data for patients with cardiac resynchronization therapy (CRT) defibrillators. BACKGROUND: The SHFM-D is among the most widely used risk stratification models for overall survival in patients with heart failure and implantable cardioverter-defibrillators (ICDs), and CMR provides highly detailed information regarding cardiac structure and function. METHODS: CMR Displacement Encoding with Stimulated Echoes (DENSE) strain imaging was used to generate the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) circumferential strain dyssynchrony parameter, and the SHFM-D was determined from clinical parameters. Multivariable Cox proportional hazards regression was used to determine adjusted hazard ratios and time-dependent areas under the curve for the primary endpoint of death, heart transplantation, left ventricular assist device, or appropriate ICD therapies. RESULTS: The cohort consisted of 100 patients (65.5 [interquartile range 57.7 to 72.7] years; 29% female), of whom 47% had the primary clinical endpoint and 18% had appropriate ICD therapies during a median follow-up of 5.3 years. CURE-SVD and the SHFM-D were independently associated with the primary endpoint (SHFM-D: hazard ratio: 1.47/SD; 95% confidence interval: 1.06 to 2.03; p = 0.02) (CURE-SVD: hazard ratio: 1.54/SD; 95% confidence interval: 1.12 to 2.11; p = 0.009). Furthermore, a favorable prognostic group (Group A, with CURE-SVD <0.60 and SHFM-D <0.70) comprising approximately one-third of the patients had a very low rate of appropriate ICD therapies (1.5% per year) and a greater (90%) 4-year survival compared with Group B (CURE-SVD ≥0.60 or SHFM-D ≥0.70) patients (p = 0.02). CURE-SVD with DENSE had a stronger correlation with CRT response (r = -0.57; p < 0.0001) than CURE-SVD with feature tracking (r = -0.28; p = 0.004). CONCLUSIONS: A combined approach to risk stratification using CMR DENSE strain imaging and a widely used clinical risk model, the SHFM-D, proved to be effective in this cohort of patients referred for CRT defibrillators. The combined use of CMR and clinical risk models represents a promising and novel paradigm to inform prognosis and device selection in the future.


Assuntos
Arritmias Cardíacas/prevenção & controle , Terapia de Ressincronização Cardíaca , Técnicas de Apoio para a Decisão , Cardioversão Elétrica , Insuficiência Cardíaca/terapia , Imagem Cinética por Ressonância Magnética , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Am J Cardiol ; 124(10): 1584-1589, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31575425

RESUMO

Heart failure with preserved ejection fraction (HFpEF) is frequently accompanied by co-morbidities and a systemic proinflammatory state, resulting in coronary microvascular dysfunction (CMD), as well as myocardial fibrosis. The purpose of this study is to examine the relation between myocardial perfusion reserve (MPR) and diffuse myocardial fibrosis in patients with HFpEF using cardiovascular magnetic resonance. A single center study was performed in 19 patients with clinical HFpEF and 15 healthy control subjects who underwent quantitative first-pass perfusion imaging to calculate global MPR. T1 mapping was used to assess fibrosis and to calculate extracellular volume. Spiral cine displacement encoded stimulated echo was used to calculate myocardial strain. Comprehensive 2D echocardiograms with speckle tracking, cardiopulmonary exercise testing, and brain natriuretic peptide levels were also obtained. In patients with HFpEF, mean left ventricular EF was 61% ± 9% and left ventricular mass index 45 ± 12 g/m2. Compared with controls, HFpEF patients had reduced global MPR (2.29 ± 0.64 vs 3.38 ± 0.76, p = 0.002) and VO2 max (16.5 ± 6.8 vs 30.9 ± 7.7 ml/kg min, p <0.001) whereas extracellular volume (0.29 ± 0.04 vs 0.25 ± 0.04, p = 0.02), pulmonary artery systolic pressure (35.4 ± 13.7 vs 22.3 ± 5.4 mm Hg, p = 0.004), and average E/e' (15.0 ± 7.6 vs 8.6 ± 2.0, p = 0.005) were increased. Displacement encoded stimulated echo peak systolic circumferential strain (p = 0.60) as well as echocardiographic derived global longitudinal strain (p = 0.07) were similar between both groups. The prevalence of CMD, defined as global MPR <2.5, in the HFpEF group was 69%. In conclusion, HFpEF patients have a high prevalence of CMD and diffuse fibrosis. These parameters may be useful clinical end points for future therapeutic trials.


Assuntos
Cardiomiopatias/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Circulação Coronária/fisiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Idoso , Cardiomiopatias/epidemiologia , Cardiomiopatias/fisiopatologia , Comorbidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Feminino , Fibrose/diagnóstico , Fibrose/epidemiologia , Fibrose/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Incidência , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Miocárdio/patologia , Prevalência , Estados Unidos/epidemiologia , Função Ventricular Esquerda
8.
Eur J Radiol ; 112: 121-129, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777200

RESUMO

OBJECTIVE: We hypothesized that Displacement Encoding with Stimulated Echoes (DENSE) and feature-tracking derived circumferential strain would provide incremental prognostic value over the extent of infarction for recovery of segmental myocardial function. METHODS: Two hundred and sixty-one patients (mean age 59 years, 73% male) underwent MRI 2 days post-ST elevation myocardial infarction (STEMI) and 241 (92%) underwent repeat imaging 6 months later. The MRI protocol included cine, 2D-cine DENSE, T2 mapping and late enhancement. Wall motion scoring was assessed by 2-blinded observers and adjudicated by a third. (WMS: 1=normal, 2=hypokinetic, 3=akinetic, 4=dyskinetic). WMS improvement was defined as a decrease in WMS ≥ 1, and normalization where WMS = 1 on follow-up. Segmental circumferential strain was derived utilizing DENSE and feature-tracking. A generalized linear mixed model with random effect of subject was constructed and used to account for repeated sampling when investigating predictors of segmental myocardial improvement or normalization RESULTS: At baseline and follow-up, 1416 segments had evaluable data for all parameters. Circumferential strain by DENSE (p < 0.001) and feature-tracking (p < 0.001), extent of oedema (p < 0.001), infarct size (p < 0.001), and microvascular obstruction (p < 0.001) were associates of both improvement and normalization of WMS. Circumferential strain provided incremental predictive value even after accounting for infarct size, extent of oedema and microvascular obstruction, for segmental improvement (DENSE: odds ratio, 95% confidence intervals: 1.08 per -1% peak strain, 1.05-1.12, p < 0.001, feature-tracking: odds ratio, 95% confidence intervals: 1.05 per -1% peak strain, 1.03-1.07, p < 0.001) and segmental normalization (DENSE: 1.08 per -1% peak strain, 1.04-1.12, p < 0.001, feature-tracking: 1.06 per -1% peak strain, 1.04-1.08, p < 0.001). CONCLUSIONS: Circumferential strain provides incremental prognostic value over segmental infarct size in patients post STEMI for predicting segmental improvement or normalization by wall-motion scoring.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Miocárdio/patologia , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Estresse Fisiológico/fisiologia
9.
Magn Reson Med ; 79(4): 2205-2215, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28734017

RESUMO

PURPOSE: To evaluate the importance of strain-correcting stimulated echo acquisition mode echo-planar imaging cardiac diffusion tensor imaging. METHODS: Healthy pigs (n = 11) were successfully scanned with a 3D cine displacement-encoded imaging with stimulated echoes and a monopolar-stimulated echo-planar imaging diffusion tensor imaging sequence at 3 T during diastasis, peak systole, and strain sweet spots in a midventricular short-axis slice. The same diffusion tensor imaging sequence was repeated ex vivo after arresting the hearts in either a relaxed (KCl-induced) or contracted (BaCl2 -induced) state. The displacement-encoded imaging with stimulated echoes data were used to strain-correct the in vivo cardiac diffusion tensor imaging in diastole and systole. The orientation of the primary (helix angles) and secondary (E2A) diffusion eigenvectors was compared with and without strain correction and to the strain-free ex vivo data. RESULTS: Strain correction reduces systolic E2A significantly when compared without strain correction and ex vivo (median absolute E2A = 34.3° versus E2A = 57.1° (P = 0.01), E2A = 60.5° (P = 0.006), respectively). The systolic distribution of E2A without strain correction is closer to the contracted ex vivo distribution than with strain correction, root mean square deviation of 0.027 versus 0.038. CONCLUSIONS: The current strain-correction model amplifies the contribution of microscopic strain to diffusion resulting in an overcorrection of E2A. Results show that a new model that considers cellular rearrangement is required. Magn Reson Med 79:2205-2215, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Tensor de Difusão , Coração/diagnóstico por imagem , Algoritmos , Animais , Simulação por Computador , Diástole , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Respiração , Respiração Artificial , Software , Estresse Mecânico , Suínos , Sístole
10.
Circ Cardiovasc Imaging ; 10(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28733364

RESUMO

The purpose of this systematic review is to provide a clinically relevant, disease-based perspective on myocardial strain imaging in patients with acute myocardial infarction or stable ischemic heart disease. Cardiac magnetic resonance imaging uniquely integrates myocardial function with pathology. Therefore, this review focuses on strain imaging with cardiac magnetic resonance. We have specifically considered the relationships between left ventricular (LV) strain, infarct pathologies, and their associations with prognosis. A comprehensive literature review was conducted in accordance with the PRISMA guidelines. Publications were identified that (1) described the relationship between strain and infarct pathologies, (2) assessed the relationship between strain and subsequent LV outcomes, and (3) assessed the relationship between strain and health outcomes. In patients with acute myocardial infarction, circumferential strain predicts the recovery of LV systolic function in the longer term. The prognostic value of longitudinal strain is less certain. Strain differentiates between infarcted versus noninfarcted myocardium, even in patients with stable ischemic heart disease with preserved LV ejection fraction. Strain recovery is impaired in infarcted segments with intramyocardial hemorrhage or microvascular obstruction. There are practical limitations to measuring strain with cardiac magnetic resonance in the acute setting, and knowledge gaps, including the lack of data showing incremental value in clinical practice. Critically, studies of cardiac magnetic resonance strain imaging in patients with ischemic heart disease have been limited by sample size and design. Strain imaging has potential as a tool to assess for early or subclinical changes in LV function, and strain is now being included as a surrogate measure of outcome in therapeutic trials.


Assuntos
Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Miocárdio/patologia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Função Ventricular Esquerda , Fenômenos Biomecânicos , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Estresse Mecânico
11.
J Magn Reson Imaging ; 46(3): 887-896, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28067978

RESUMO

PURPOSE: To image late mechanical activation and identify effective left-ventricular (LV) pacing sites for cardiac resynchronization therapy (CRT). There is variability in defining mechanical activation time, with some studies using the time to peak strain (TPS) and some using the time to the onset of circumferential shortening (TOS). We developed improved methods for imaging mechanical activation and evaluated them in heart failure (HF) patients undergoing CRT. MATERIALS AND METHODS: We applied active contours to cine displacement encoding with stimulated echoes (DENSE) strain images to detect TOS. Six healthy volunteers underwent magnetic resonance imaging (MRI) at 1.5T, and 50 patients underwent pre-CRT MRI (strain, scar, volumes) and echocardiography, assessment of the electrical activation time (Q-LV) at the LV pacing site, and echocardiography assessment of LV reverse remodeling 6 months after CRT. TPS at the LV pacing site was also measured by DENSE. RESULTS: The latest TOS was greater in HF patients vs. healthy subjects (112 ± 28 msec vs. 61 ± 7 msec, P < 0.01). The correlation between TOS and Q-LV was strong (r > 0.75; P < 0.001) and better than between TPS and Q-LV (r < 0.62; P ≥ 0.006). Twenty-three of 50 patients had the latest activating segment in a region other than the mid-ventricular lateral wall, the most common site for the CRT LV lead. Using a multivariable model, TOS/QRS was significantly associated with LV reverse remodeling even after adjustment for overall dyssynchrony and scar (P < 0.05), whereas TPS was not (P = 0.49). CONCLUSION: Late activation by cine DENSE TOS analysis is associated with improved LV reverse remodeling with CRT and deserves further study as a tool to achieve optimal LV lead placement in CRT. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:887-896.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Remodelação Ventricular/fisiologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Resultado do Tratamento
12.
J Cardiovasc Magn Reson ; 18(1): 38, 2016 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-27301487

RESUMO

BACKGROUND: Cine Displacement Encoding with Stimulated Echoes (DENSE) provides accurate quantitative imaging of cardiac mechanics with rapid displacement and strain analysis; however, image acquisition times are relatively long. Compressed sensing (CS) with parallel imaging (PI) can generally provide high-quality images recovered from data sampled below the Nyquist rate. The purposes of the present study were to develop CS-PI-accelerated acquisition and reconstruction methods for cine DENSE, to assess their accuracy for cardiac imaging using retrospective undersampling, and to demonstrate their feasibility for prospectively-accelerated 2D cine DENSE imaging in a single breathhold. METHODS: An accelerated cine DENSE sequence with variable-density spiral k-space sampling and golden angle rotations through time was implemented. A CS method, Block LOw-rank Sparsity with Motion-guidance (BLOSM), was combined with sensitivity encoding (SENSE) for the reconstruction of under-sampled multi-coil spiral data. Seven healthy volunteers and 7 patients underwent 2D cine DENSE imaging with fully-sampled acquisitions (14-26 heartbeats in duration) and with prospectively rate-2 and rate-4 accelerated acquisitions (14 and 8 heartbeats in duration). Retrospectively- and prospectively-accelerated data were reconstructed using BLOSM-SENSE and SENSE. Image quality of retrospectively-undersampled data was quantified using the relative root mean square error (rRMSE). Myocardial displacement and circumferential strain were computed for functional assessment, and linear correlation and Bland-Altman analyses were used to compare accelerated acquisitions to fully-sampled reference datasets. RESULTS: For retrospectively-undersampled data, BLOSM-SENSE provided similar or lower rRMSE at rate-2 and lower rRMSE at rate-4 acceleration compared to SENSE (p < 0.05, ANOVA). Similarly, for retrospective undersampling, BLOSM-SENSE provided similar or better correlation with reference displacement and strain data at rate-2 and better correlation at rate-4 acceleration compared to SENSE. Bland-Altman analyses showed similar or better agreement for displacement and strain data at rate-2 and better agreement at rate-4 using BLOSM-SENSE compared to SENSE for retrospectively-undersampled data. Rate-2 and rate-4 prospectively-accelerated cine DENSE provided good image quality and expected values of displacement and strain. CONCLUSIONS: BLOSM-SENSE-accelerated spiral cine DENSE imaging with 2D displacement encoding can be acquired in a single breathhold of 8-14 heartbeats with high image quality and accurate assessment of myocardial displacement and circumferential strain.


Assuntos
Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Adulto , Idoso , Fenômenos Biomecânicos , Suspensão da Respiração , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estresse Mecânico , Fatores de Tempo , Adulto Jovem
13.
J Cardiovasc Magn Reson ; 17: 110, 2015 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-26692265

RESUMO

BACKGROUND: Assessment of diffuse right ventricular (RV) fibrosis is of particular interest in pulmonary hypertension (PH) and heart failure (HF). Current cardiovascular magnetic resonance (CMR) T1 mapping techniques such as Modified Look-Locker inversion recovery (MOLLI) imaging have limited resolution, but accelerated and navigator-gated Look-Locker imaging for cardiac T1 estimation (ANGIE) is a novel CMR sequence with spatial resolution suitable for T1 mapping of the RV. We tested the hypothesis that patients with PH would have significantly more RV fibrosis detected with MRI ANGIE compared with normal volunteers and patients having HF with reduced (LV) ejection fraction (HFrEF) without co-existing PH, independent of RV dilitation and dysfunction. METHODS: Patients with World Health Organization group 1 or group 4 PH, patients with HFrEF without PH, and normal volunteers were recruited to undergo contrast-enhanced CMR. RV and LV extracellular volume fractions (RV-ECV and LV-ECV) were determined using pre-contrast and post-contrast T1 mapping using ANGIE (RV and LV) and MOLLI (LV only). RESULTS: Thirty-two participants (53.1% female, median age 52 years, IQR 26-65 years) were enrolled, including n = 12 with PH, n = 10 having HFrEF without co-existing PH, and n = 10 normal volunteers. ANGIE ECV imaging was of high quality, and ANGIE measurements of LV-ECV were highly correlated with those of MOLLI (r = 0.91; p < 0.001). The RV-ECV in PH patients was 27.2% greater than the RV-ECV in normal volunteers (0.341 v. 0.268; p < 0.0001) and 18.9% greater than the RV-ECV in HFrEF patients without PH (0.341 v. 0.287; p < 0.0001). RV-ECV was greater than LV-ECV in PH (RV-LV difference = 0.04), but RV-ECV was nearly equivalent to LV-ECV in normal volunteers (RV-LV difference = 0.002) (p < 0.0001 for RV-LV difference in PH versus normal volunteers). RV-ECV was linearly associated with both increasing RVEDVI (p = 0.049) and decreasing RVEF (p = 0.04) in a multivariable linear model, but PH was still associated with greater RV-ECV even after adjustment for RVEDVI and RVEF. CONCLUSIONS: Pre- and post-contrast ANGIE imaging provides high-resolution ECV determination for the RV. PH is independently associated with increased RV-ECV even after adjustment for RV dilatation and dysfunction, consistent with an independent effect of PH on fibrosis. ANGIE RV imaging merits further clinical evaluation in PH.


Assuntos
Ventrículos do Coração/fisiopatologia , Hipertensão Pulmonar/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Direita , Adulto , Idoso , Estudos de Casos e Controles , Meios de Contraste , Estudos de Viabilidade , Feminino , Fibrose , Gadolínio DTPA , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/patologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Função Ventricular Esquerda
14.
J Cardiovasc Magn Reson ; 16: 8, 2014 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-24423129

RESUMO

BACKGROUND: The most time consuming and limiting step in three dimensional (3D) cine displacement encoding with stimulated echoes (DENSE) MR image analysis is the demarcation of the left ventricle (LV) from its surrounding anatomical structures. The aim of this study is to implement a semi-automated segmentation algorithm for 3D cine DENSE CMR using a guide point model approach. METHODS: A 3D mathematical model is fitted to guide points which were interactively placed along the LV borders at a single time frame. An algorithm is presented to robustly propagate LV epicardial and endocardial surfaces of the model using the displacement information encoded in the phase images of DENSE data. The accuracy, precision and efficiency of the algorithm are tested. RESULTS: The model-defined contours show good accuracy when compared to the corresponding manually defined contours as similarity coefficients Dice and Jaccard consist of values above 0.7, while false positive and false negative measures show low percentage values. This is based on a measure of segmentation error on intra- and inter-observer spatial overlap variability. The segmentation algorithm offers a 10-fold reduction in the time required to identify LV epicardial and endocardial borders for a single 3D DENSE data set. CONCLUSION: A semi-automated segmentation method has been developed for 3D cine DENSE CMR. The algorithm allows for contouring of the first cardiac frame where blood-myocardium contrast is almost nonexistent and reduces the time required to segment a 3D DENSE data set significantly.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Modelos Cardiovasculares , Função Ventricular Esquerda , Adulto , Automação , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Adulto Jovem
15.
J Cardiovasc Magn Reson ; 14: 4, 2012 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-22236389

RESUMO

BACKGROUND: The mechanics of the right ventricle (RV) are not well understood as studies of the RV have been limited. This is, in part, due to the RV's thin wall, asymmetric geometry and irregular motion. However, the RV plays an important role in cardiovascular function. This study aims to describe the complex mechanics of the healthy RV using three dimensional (3D) cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance (CMR). METHODS: Whole heart 3D cine DENSE data were acquired from five healthy volunteers. Tailored post-processing algorithms for RV mid-wall tissue tracking and strain estimation are presented. A method for sub-dividing the RV into four regions according to anatomical land marks is proposed, and the temporal evolution of strain was assessed in these regions. RESULTS: The 3D cine DENSE tissue tracking methods successfully capture the motion and deformation of the RV at a high spatial resolution in all volunteers. The regional Lagrangian peak surface strain and time to peak values correspond with previous studies using myocardial tagging, DENSE and strain encoded CMR. The inflow region consistently displays lower peak strains than the apical and outflow regions, and the time to peak strains suggest RV mechanical activation in the following order: inflow, outflow, mid, then apex. CONCLUSIONS: Model-free techniques have been developed to study the myocardial mechanics of the RV at a high spatial resolution using 3D cine DENSE CMR. The consistency of the regional RV strain patterns across healthy subjects is encouraging and the techniques may have clinical utility in assessing disrupted RV mechanics in the diseased heart.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Adulto , Algoritmos , Pontos de Referência Anatômicos , Fenômenos Biomecânicos , Ventrículos do Coração/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Contração Miocárdica , Valor Preditivo dos Testes , Valores de Referência , África do Sul , Estresse Mecânico , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA