Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Contemp Dent Pract ; 24(9): 668-673, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152940

RESUMO

AIM: To compare fracture resistance of multiple treatment modalities intended for mutilated teeth using polyether ether ketone (PEEK) and zirconia materials. MATERIALS AND METHODS: The study was divided into four groups according to treatment modality adopted (n = 14): fiber post (F), Nayyar core (N), endocrown (E), and Richmond crown (R). Each group was further subdivided into two groups (n = 7) according to the type of material used: zirconia (Z) and PEEK (P). Using computer-aided design/computer-aided manufacturing, restorations were constructed from both materials following tested treatment options and manufacturer direction. Finished restorations were then tried, seated, and cemented to their corresponding acrylic teeth. All specimens were tested for fracture resistance in universal testing machine with cross head speed of 0.5 mm/min speed until failure, which was confirmed by a sudden drop in the measurements of the testing machine. Results were recorded, tabulated, and statistically analyzed. Shapiro-Wilk normality tests were considered to evaluate the normality of the data distributions. One-way analysis of variance (ANOVA) followed by Tukey's post hoc analysis was conducted to analyze the fracture resistance significant differences. RESULTS: Descriptive statistics of the restoration material revealed statistically a higher mean value for PEEK material (3609 ± 188.1) than zirconia (2404 ± 425.6). One-way ANOVA revealed statistically significant differences between zirconia group (p < 0.0001). Regarding zirconia group statistical significance was detected between fiber post vs endocrown (p = 0.0299), fiber post vs Richmond crown (p < 0.0001), and Nayyar core vs Richmond crown (p = 0.0004). However, there was no statistically significant difference between PEEK group (P = 0.1614). CONCLUSION: Polyether ether ketone could present a reliable treatment option in endodontically treated teeth. CLINICAL SIGNIFICANCE: Using one-piece Richmond crowns constructed of PEEK could present a viable treatment option against conventional treatment options of root canal treatment (RCT) single-rooted teeth.


Assuntos
Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Dente não Vital/terapia , Coroas , Éteres , Análise do Estresse Dentário , Teste de Materiais , Falha de Restauração Dentária
2.
J Contemp Dent Pract ; 24(9): 679-687, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152942

RESUMO

AIM: To evaluate the effect of low-intensity pulsed ultrasound (LIPU) application on dental implant accelerated osseointegration in the two-stage implant protocol. MATERIALS AND METHODS: A total of 20 implants were placed in 10 mature mongrel dogs, two implants for each dog replacing the lower 3rd premolars bilaterally. After 3 months of extraction, implants were placed. After 24 hours of implantation, the right sides received LIPU for 20 mins/day, continuously for 20 days. The left sides didn't receive LIPU (control). Standardized radiographs were taken before LIPU and after 10 and 20 days for both sides. After 20 days of LIPU application, second-stage surgery was performed and provisional crowns were placed on each implant. Implants were subjected to functional occlusal loading for 4 weeks. Standardized radiographs were taken after 2 and 4 weeks of loading and analyzed to assess the peri-implant bone density changes. All data were collected, tabulated, and statistically analyzed. RESULTS: All tissues appeared clinically normal, with the absence of inflammation and peri-implant radiolucency. The survival rate was 100%. The LIPU group showed a statistically significantly higher percentage increase in mean bone density after 10 LIPU sessions, 20 LIPU sessions, and 2 and 4 weeks of loading, than a control group. CONCLUSION: The LIPU stimulation radiographically increased the bone density around implant area and accelerated osseointegration in the two-stage implant protocol. CLINICAL SIGNIFICANCE: Low-intensity pulsed ultrasound stimulation could be beneficial in accelerating osseointegration and thus shortening the waiting period for final prosthetic delivery.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Animais , Cães , Implantação Dentária Endóssea/métodos , Osseointegração/fisiologia , Radiografia , Ondas Ultrassônicas , Prótese Dentária Fixada por Implante , Coroas
3.
J Contemp Dent Pract ; 24(8): 545-550, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38193175

RESUMO

AIM: The color difference between the final shade of restorations milled from different zirconia blocks, and the control teeth in the esthetic zone is yet uncertain. MATERIALS AND METHODS: For eight patients who required a singular maxillary central incisor restoration, twenty-four crowns made of zirconia were created. These were grouped into three categories based on the shade and nature of zirconia (Zr) utilized (white core, colored core, and monolithic high-translucency (ht) Zr crowns). The difference in color (ΔE) between the three zirconia crowns and the neighboring teeth was calculated by the use of Easyshade spectrophotometer. Two shades of resin luting cement were used. The measured ΔE values were evaluated based on a clinically acceptable color difference of 1.6ΔE, which is not visible to the human eye. RESULTS: Among the three groups, no differences of statistical significance were observed in terms of ΔE with different Zr types and resin cement color. CONCLUSION: Within the limits of this study, the usage of different shades of zirconia blanks and resin cements did not display a statistically significant effect on the final color of the crown. CLINICAL SIGNIFICANCE: Changing the shade of resin cements does not appear to add value to the final shade of crown. In addition, the generation of zirconia does not influence the shade of the crown. Crowns made of zirconia can be cemented with opaque or transparent cement with no effect on the final color.


Assuntos
Boca Edêntula , Cimentos de Resina , Humanos , Estética Dentária , Incisivo
4.
J Contemp Dent Pract ; 24(11): 840-846, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238270

RESUMO

AIM: To investigate six different strengthening mechanisms for three-unit implant-supported provisional restorations. MATERIALS AND METHODS: Six techniques of provisional fixed prostheses (PFP) reinforcement were investigated and were assigned to different groups (n = 10): group (ZP) zirconia powder, group (SK8) silk thread wrapped as a figure-of-8 pattern around middle third of abutment, group (RC8) size 00 retraction cord wrapped as a figure-of-8 pattern around middle third of abutment, group (RF8) Resin impregnated glass fiber ribbon wrapped as a figure-of-8 pattern around abutment, group (KV8) Kevlar 29 cord wrapped as a figure-of-8 pattern around middle third of abutment, group (KV) Kevlar 29 strands incorporated in resin mix. Compared against unenforced bis-acryl as control group (CL). Seventy Metal Dies were 3D printed having Soft Tissue Gingiva Mask. Using a custom-made silicone Index, 70 PFP were fabricated (10 of each group) and were cemented to their corresponding metal dies using zinc polycarboxylate cement. All specimens were thermal cycled for 1000 cycles using order of 20 seconds at 55°C and 20 seconds at 5°C with 10 seconds transport. Fracture resistance test was done using universal testing machine. All specimens were loaded to failure. Data were collected, tabulated and statistically analyzed. RESULTS: Kolmogorov-Smirnov normality test showed no significant difference between data in each group. So, data are normally distributed in each group. Descriptive statistics showed higher mean values of CL group (780.8 ± 164) followed by RF8 group (614.2 ± 158.2), followed by RC8 group (550.2 ± 339.2), followed by KV8 group (442.1 ± 198.4), followed by KV group (403.9 ± 306), followed by SK8 group (175.9 ± 90.8), and finally ZP group (136.5 ± 135.7). One-way ANOVA revealed significant difference between the tested groups (p = 0.036). CONCLUSION: Bis-acryl provisional restorations had better mean fracture resistance values than all other strengthening mechanisms. Bis-acryl provisional restorations did not gain more strength by any of the added materials. One-way ANOVA revealed significant difference between all tested groups. CLINICAL SIGNIFICANCE: Provisional restorations over implant should be strong enough to serve for the long period of bone and tissue healing. Current materials alone cannot survive for long. It serves as temporization between steps of fixed restorations construction. How to cite this article: Rayyan M, Sayed M, Hujeiry AM et al. Comparison of Fracture Resistance between Implant-supported Bis-acryl Interim 3-unit FDPs Using Six Different Strengthening Mechanisms: An In Vitro Study. J Contemp Dent Pract 2023;24(11):840-846.


Assuntos
Implantes Dentários , Polimetil Metacrilato , Restauração Dentária Temporária , Teste de Materiais , Análise do Estresse Dentário , Falha de Restauração Dentária
5.
J Clin Exp Dent ; 12(3): e257-e263, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32190196

RESUMO

BACKGROUND: Zirconia crowns are highly attractive for clinicians, although have poor translucency when used as single restorations, in addition to unknown effect of resin cement shade on final cemented crown shade. This study aimed to assess effect of resin cement opacity on color replication potential of different zirconia frameworks with target tooth color, in addition to different zirconia crowns translucency evaluation. MATERIAL AND METHODS: Twenty-four zirconia crown restorations were fabricated to restore single central maxillary incisor for 8 patients, divided into 3 groups according to color and type of zirconia used (white Zr core, colored Zr core and monolithic HT Zrcowns). Each group was further subdivided into 2 subgroups according to resin cement shade. Using Easyshade spectrophotometer, Delta E color difference was calculated between each crown parameters using 2 different resin luting cement shades and adjacent target tooth. Translucency parameters (TP) were tested for finished crowns. ΔEs obtained were assessed based on ΔEof 1.6 which represented color difference that could not be detected by human eye and considered clinically acceptable. RESULTS: No statistically significant values were found between subgroups related to different resin cement shade. Translucency parameters showed statistically significant different values. Monolithic crowns showed highest translucency parameters followed by Zr crowns on white cores then Zr crowns on colored cores. CONCLUSIONS: Resin cement shade didn't affect final color perception. Monolithic high translucency crowns usage gained advantages of high translucency and delamination prevention. Zirconia crowns could be cemented by opaque or transparent cement without affecting final color. Key words:Zirconia, resin cement, monolithic, translucency, spectrophotometer, Delta E.

6.
J Clin Exp Dent ; 12(1): e46-e51, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31976043

RESUMO

BACKGROUND: A lot of shaded zirconia blocks are being introduced into the market. Their effect on the final shade of the restoration is yet uncertain. MATERIAL AND METHODS: Twenty-four zirconia crowns were fabricated for 8 patients who needed to restore a single maxillary central incisor, and divided into 3 groups according to the color and type of the zirconia (Zr) used (white Zr core, colored Zr core, and monolithic high translucency (ht) Zr crowns). Using Easyshade spectrophotometer, delta E color difference was calculated between fabricated crown and adjacent tooth. The ΔEs obtained were assessed based on 1.6 ΔE which represented the color difference that could not be detected by the human eye and considered clinically acceptable. RESULTS: No statistically significant values were found between the 3 groups related to different Zr color and type. CONCLUSIONS: Within the limitations of this study, it could be concluded that the shade of the zirconia blank had no significant effect on the final color of the crown. This raises reasonable doubt about the necessity to use colored zirconia blanks or use of dip-in solutions. The clinical implications were that, there was no need to use colored zirconia cores to get more esthetically pleasing restorations with respect to color perception. The use of monolithic high translucent zirconia crowns gained the advantages of high translucency and color reproduction. Key words:Zirconia, easyshade, monolithic, spectrophotometer, delta E.

7.
J Prosthet Dent ; 96(6): 397-401, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17174656

RESUMO

STATEMENT OF PROBLEM: Clinically relevant assessment of all-ceramic crowns supported by esthetic composite resin foundations has not been evaluated with regard to color reproducibility. PURPOSE: This in vitro study quantitatively evaluated the influence of different shades of composite resin foundations and resin cement on the final color of a leucite-reinforced all-ceramic material. MATERIAL AND METHODS: A total of 128 disks were fabricated; 64 (20 x 1 mm) were made of all-ceramic material (IPS Empress) and 64 (20 x 4 mm) of 4 different shades composite resin (Tetric Ceram). The ceramic and composite resin disks were luted using 2 shades (A3 and Transparent) of resin cement (Variolink II). Color was measured using a colorimeter configured with a diffuse illumination/0-degree viewing geometry, and Commission Internationale de l'Eclairage (CIE) L( *)a( *)b( *) values were directly calculated. Descriptive statistical analysis was performed, and color differences (DeltaE) for the average L( *), a( *) and b( *) color parameters were calculated. Repeated measures analysis of variance (ANOVA) was used to compare mean values and SDs between the different color combinations (alpha=.05). RESULTS: The CIE L( *)a( *)b( *) color coordinate values showed no significant differences for variation in color parameters due to the effect of the different composite resin shades (P=.24) or cement shades (P=.12). The mean color difference (DeltaE) value between the groups was 0.8. CONCLUSION: Within the limitations of this study, the use of different shades for composite resin cores and resin cements presented no statistically significant effect on the final color of IPS Empress all-ceramic material.


Assuntos
Silicatos de Alumínio/química , Cor , Coroas , Materiais Dentários/química , Porcelana Dentária/química , Pigmentação em Prótese/métodos , Resinas Acrílicas/química , Análise de Variância , Colorimetria/instrumentação , Colorimetria/métodos , Resinas Compostas/química , Poliuretanos/química , Cimentos de Resina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA