RESUMO
This study established the simultaneous determination of the selected endocrine-disrupting compounds (EDCs) and pesticides in rock, soil, water, moss, and feces samples collected from the Antarctic region. The spray-assisted droplet formation-based liquid phase microextraction (SADF-LPME) coupled to GC-MS system was developed and validated for the screening and monitoring of 29 selected EDCs and pesticides. Binary solvent system, 1:1 (v/v) dichlormethane: 1,2-dichloroethane mixture was employed as an extraction solvent and sprayed onto sample or standard solutions using a straightforward and practical spray apparatus. The factors affecting the extraction process such as extraction solvent type and ratio, extraction solvent volume (spray repetition), vortexing period, and sample pH were properly optimized. Analytical figures of the merit of the method were recorded under the optimal extraction/chromatographic conditions. The LOD, LOQ, and enhancement factor were in the range of 1.0 to 6.6 ng/g, 3.2 to 22.1 ng/g, and 3.7 to 158.9, respectively. The method demonstrated a good linear working range for all the selected analytes with proper coefficients of determination. The usability and reliability of the microextraction strategy was confirmed using seawater, moss, and soil samples, and the %recoveries were within an acceptable range (> 70%) for all examined samples. The environmental samples collected from the Horseshoe and Faure Islands of the Antarctica region were analyzed to assess the potential pollution of EDCs and pesticides. This method has the potential to be employed for the analysis of EDCs in routine analytical laboratories and for controlling and screening the organic pollutant content of different environmental samples.
Assuntos
Disruptores Endócrinos , Microextração em Fase Líquida , Praguicidas , Água/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Disruptores Endócrinos/análise , Regiões Antárticas , Microextração em Fase Líquida/métodos , Reprodutibilidade dos Testes , Solo , Solventes/químicaRESUMO
In this study, detection sensitivity of the conventional flame atomic absorption spectrophotometer (FAAS) for the determination of manganese (Mn2+) was enhanced by employing a preconcentration method from wastewater samples. Flower-shaped Ni(OH)2 nanomaterials were synthesized and used as sorbent material in preconcentration procedure. With the aim of attaining optimum experimental conditions, effective parameters of extraction method were optimized and these included pH of buffer solution, desorption solvent concentration and volume, mixing type and period, nanoflower amount, and sample volume. The detection limit of the optimized method was determined to be 2.2 µg L-1, and this correlated to about 41-fold enhancement in detection power relative to direct FAAS measurement. Domestic wastewater was used to test the feasibility of the proposed method to real samples by performing spike recovery experiments. The wastewater sample was spiked at four different concentrations of manganese, and the percent recoveries determined were in the range of 95-120%.