RESUMO
We present a compact setup for spin-, time-, and angle-resolved photoemission spectroscopy. A 10 kHz titanium sapphire laser system delivers pulses of 20 fs duration, which drive a high harmonic generation-based source for ultraviolet photons at 21 eV for photoemission. The same laser also excites the sample for pump-probe experiments. Emitted electrons pass through a hemispherical energy analyzer and a spin-filtering element. The latter is based on spin-polarized low-energy electron diffraction on an Au-passivated iridium crystal. The performance of the measurement system is discussed in terms of the resolution and efficiency of the spin filter, which are higher than those for Mott-based techniques.
RESUMO
Prior to the development of pulsed lasers, one assigned a single local temperature to the lattice, the electron gas, and the spins. With the availability of ultrafast laser sources, one can now drive the temperature of these reservoirs out of equilibrium. Thus, the solid shows new internal degrees of freedom characterized by individual temperatures of the electron gas T_{e}, the lattice T_{l} and the spins T_{s}. We demonstrate an analogous behavior in the spin polarization of a ferromagnet in an ultrafast demagnetization experiment: At the Fermi energy, the polarization is reduced faster than at deeper in the valence band. Therefore, on the femtosecond time scale, the magnetization as a macroscopic quantity does not provide the full picture of the spin dynamics: The spin polarization separates into different parts similar to how the single temperature paradigm changed with the development of ultrafast lasers.
RESUMO
As Stern-Gerlach type spin filters do not work with electrons, spin analysis of electron beams is accomplished by spin-dependent scattering processes based on spin-orbit or exchange interaction. Existing polarimeters are single-channel devices characterized by an inherently low ï¬gure of merit (FoM) of typically 10â»4-10⻳. This single-channel approach is not compatible with parallel imaging microscopes and also not with modern electron spectrometers that acquire a certain energy and angular interval simultaneously. We present a novel type of polarimeter that can transport a full image by making use of k-parallel conservation in low-energy electron diffraction. We studied specular reflection from Ir (001) because this spin-filter crystal provides a high analyzing power combined with a "lifetime" in UHV of a full day. One good working point is centered at 39 eV scattering energy with a broad maximum of 5 eV usable width. A second one at about 10 eV shows a narrower profile but much higher FoM. A relativistic layer-KKR SPLEED calculation shows good agreement with measurements.
RESUMO
A compact coil setup, in conjunction with a high power current pulser, is presented; developed especially for time- and spin-resolved photoemission spectroscopy measuring the sample in magnetic remanence at room temperature. A novel approach is presented where the sample is switched in the stray field of a coil pair. This enables the electrical biasing of the sample without altering the electron trajectories due to field gradients introduced by the coils. The pulser driving the coils reaches a peak power of 1 MW at 1 kA with a switching frequency up to 10 kHz suitable for experiments, for example, with state of the art repetition rates of femtosecond laser systems.