Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMJ Open Qual ; 12(4)2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097283

RESUMO

INTRODUCTION: Fluid balance monitoring is pivotal to patients' health. Thus, fluid balance charting is an essential part of clinical nursing documentation. This systematic review aimed to investigate and describe the quality of fluid balance monitoring in medical, surgical and intensive care units, with an emphasis on the completeness of charting data, calculation errors and accuracy, and to evaluate methods used to improve fluid balance charting. MATERIALS AND METHODS: Quantitative studies involving adult patients and reporting data on fluid balance monitoring were included in the review. We searched MEDLINE, Embase, CINAHL and the Cochrane Library. The risk of bias in the included studies was assessed using tools developed by the Joanna Briggs Institute. RESULTS: We included a total of 23 studies, which involved 6649 participants. The studies were quasi-experimental, cohort or prevalence studies, and every third study was of low quality. Definitions of 'completeness' varied, as well as patient categories and time of evaluation. Eighteen studies reported the prevalence of patients with complete fluid balance charts; of those, 10 reported that not more than 50% of fluid balance charts were complete. Studies addressing calculation errors found them in 25%-35% of charts, including omissions of, for example, intravenous medications. The reported interventions consisted of various components such as policies, education, equipment, visual aids, surveillance and dissemination of results. Among studies evaluating interventions, only 38% (5 of 13) achieved compliance with at least 75% of complete fluid balance charts. Due to the heterogeneity of the studies, a meta-analysis was not possible. CONCLUSION: The quality of fluid balance charting is inadequate in most studies, and calculation errors influence quality. Interventions included several components, and the impact on the completion of fluid balance charts varied.


Assuntos
Unidades de Terapia Intensiva , Equilíbrio Hidroeletrolítico , Adulto , Humanos , Estudos Transversais
2.
J Alzheimers Dis ; 92(2): 653-665, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36776073

RESUMO

BACKGROUND: Recent studies suggested induction of 40 Hz neural activity as a potential treatment for Alzheimer's disease (AD). However, prolonged exposure to flickering light raises adherence and safety concerns, encouraging investigation of tolerable light stimulation protocols. OBJECTIVE: To investigate the safety, feasibility, and exploratory measures of efficacy. METHODS: This two-stage randomized placebo-controlled double-blinded clinical trial, recruited first cognitive healthy participants (n = 3/2 active/placebo), and subsequently patients with mild-to-moderate AD (n = 5/6, active/placebo). Participants were randomized 1:1 to receive either active intervention with 40 Hz Invisible Spectral Flicker (ISF) or placebo intervention with color and intensity matched non-flickering white light. RESULTS: Few and mild adverse events were observed. Adherence was above 86.1% of intended treatment days, with participants remaining in front of the device for >51.3 min (60 max) and directed gaze >34.9 min. Secondary outcomes of cognition indicate a tendency towards improvement in the active group compared to placebo (mean: -2.6/1.5, SD: 6.58/6.53, active/placebo) at week 6. Changes in hippocampal and ventricular volume also showed no tendency of improvement in the active group at week 6 compared to placebo. At week 12, a potential delayed effect of the intervention was seen on the volume of the hippocampus in the active group compared to placebo (mean: 0.34/-2.03, SD: 3.26/1.18, active/placebo), and the ventricular volume active group (mean: -0.36/2.50, SD: 1.89/2.05, active/placebo), compared to placebo. CONCLUSION: Treatment with 40 Hz ISF offers no significant safety or adherence concerns. Potential impact on secondary outcomes must be tested in larger scale clinical trials.


Assuntos
Doença de Alzheimer , Fototerapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Alzheimer/classificação , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/terapia , Método Duplo-Cego , Estudos de Viabilidade , Fototerapia/efeitos adversos , Fototerapia/métodos , Projetos Piloto , Resultado do Tratamento
3.
J Neurosci Methods ; 378: 109659, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35772608

RESUMO

BACKGROUND: Neuromodulation is a rapidly expanding therapeutic option considered within neuropsychiatry, pain and rehabilitation therapy. Combining electrostimulation with feedback from fMRI can provide information about the mechanisms underlying the therapeutic effects, but so far, such studies have been hampered by the lack of technology to conduct safe and accurate experiments. Here we present a system for fMRI compatible electrical stimulation, and the first proof-of-concept neuroimaging data with deep brain stimulation (DBS) in pigs obtained with the device. NEW METHOD: The system consists of two modules, placed in the control and scanner room, connected by optical fiber. The system also connects to the MRI scanner to timely initiate the stimulation sequence at start of scan. We evaluated the system in four pigs with DBS in the subthalamic nucleus (STN) while we acquired BOLD responses in the STN and neocortex. RESULTS: We found that the system delivered robust electrical stimuli to the implanted electrode in sync with the preprogrammed fMRI sequence. All pigs displayed a DBS-STN induced neocortical BOLD response, but none in the STN. COMPARISONS WITH EXISTING METHOD: The system solves three major problems related to electric stimuli and fMRI examinations, namely preventing distortion of the fMRI signal, enabling communication that synchronize the experimental conditions, and surmounting the safety hazards caused by interference with the MRI scanner. CONCLUSIONS: The fMRI compatible electrical stimulator circumvents previous problems related to electroceuticals and fMRI. The system allows flexible modifications for fMRI designs and stimulation parameters, and can be customized to electroceutical applications beyond DBS.


Assuntos
Estimulação Encefálica Profunda , Núcleo Subtalâmico , Animais , Estimulação Elétrica , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Núcleo Subtalâmico/diagnóstico por imagem , Núcleo Subtalâmico/fisiologia , Suínos
4.
J Alzheimers Dis ; 88(1): 335-344, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35570490

RESUMO

BACKGROUND: Exposure to 40 Hz stroboscopic light, for one hour a day, has previously been published as a potential treatment option for Alzheimer's disease in animal models. However, exposure for an hour a day to 40 Hz stroboscopic light can be strenuous and examining other types of 40 Hz inducing stimuli is paramount if chronic treatment is wanted. OBJECTIVE: A core assumption behind ensuring a therapeutic outcome is that the visual stimuli can induce 40 Hz gamma entrainment. Here, we examine whether a specific visual stimulus, 40 Hz invisible spectral flicker (ISF), can induce gamma entrainment and how it differs from both continuous light (CON) and 40 Hz stroboscopic light (STROBE). METHODS: The study included non-simultaneous EEG-fMRI neuroimaging of 13 young healthy volunteers during light exposure. Each light condition (i.e., CON, ISF, or STROBE) was active for 30 seconds followed immediately by the next. RESULTS: Entrainment of 40 Hz neural activity were significantly higher signal-to-noise ratio during exposure to ISF (mean: 3.03, 95% CI 2.07 to 3.99) and STROBE (mean: 12.04, 95% CI 10.18 to 13.87) compared to CON. Additionally STROBE had a higher entrainment than ISF (mean: 9.01, 95% CI 7.16 to 12.14). CONCLUSION: This study presents a novel method of 40 Hz entrainment using ISF. This enables the possibility of future randomized placebo-controlled clinical trials with acceptable double blinding due to the essentially imperceivable flicker, which is expected to substantially reduce discomfort compared to interventions with stroboscopic flicker.


Assuntos
Doença de Alzheimer , Animais , Humanos , Estimulação Luminosa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA