Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Interv Cardiol ; 18: e11, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37398871

RESUMO

Guidelines recommend primary prevention implantable cardioverter defibrillator (PPICD) for left ventricular ejection fraction (LVEF) <35% only after 3 months of optimal medical therapy (OMT) or 6 weeks after acute MI with persistent LVEF dysfunction. A 73-year-old woman presented with decompensated heart failure secondary to ischaemic cardiomyopathy. Severe coronary disease with sufficient dysfunctional myocardial segments on cardiac MRI suggested potential benefit from revascularisation. Following discussion with the heart team, she underwent percutaneous coronary intervention (PCI). PPICD implantation was deferred as per guideline recommendations. However, 20 days post-PCI, the patient died from malignant ventricular arrhythmia captured on a Holter monitor. This case demonstrates that some high-risk patients may not receive a potentially life-saving PPICD if guidelines are stringently adhered to. We highlight evidence that LVEF alone is of limited value in a risk assessment of arrhythmogenic death, and postulate that a more personalised ICD prescription should be considered using scar characteristics on cardiac MRI to prompt upstream ICD implantation in high-risk patients.

3.
Curr Hypertens Rev ; 18(1): 64-69, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33992056

RESUMO

BACKGROUND: Acute stress is known to be associated with both negative and positive influences on cognitive performance. Hypertension is one of the risk factors for lowered cognitive performance. Mental stress testing is easier to administer and can be regulated by the investigator. Mental arithmetic using serial subtraction is the most widely used method to administer stress. Reaction time (RT) is widely used to assess cognitive domains like attention, execution and psychomotor speed. Researchers have shown choice reaction times are delayed in hypertension. It is not known whether acute mental stress improves or deteriorates attention, execution and psychomotor speed in hypertension. We hypothesized in the present study that acute mental stress deteriorates cognitive function in hypertensives without overt cerebrovascular disease or other vascular risk factors. METHODS: After getting medical ethical clearance from our institution, this case-control study was carried out over eight months (January 2017 to September 2017). 60 subjects between the age group of 35 to 55 years were included in the study. They were divided into 2 groups. Group 1 consisted of 30 diagnosed cases of hypertension at least two years of duration. Group 2 consisted of 30 sex and age-matched controls. MMSE was performed to assess the cognitive function in these groups. Simple (S) and choice (C) auditory reaction time (ART) and visual reaction time (VRT)s were measured at rest and acute mental stress in these groups to assess cognitive function. Predictive value of VRTC resting and VRTC during acute mental stress among hypertensives for cognitive dysfunction was calculated using the receiver operating characteristic (ROC) curve. RESULTS: There was significant difference ART and VRT, both simple and choice, in hypertensive and nonhypertensive subjects and these reaction times further increased during mental stress (P<0.001). VRTC can be a predictor of cognitive dysfunction in hypertensives and during acute mental stress. CONCLUSION: A significant difference in cognitive functions in hypertensive and nonhypertensive subjects exists and this further deteriorates with acute mental stress.


Assuntos
Disfunção Cognitiva , Hipertensão , Adulto , Estudos de Casos e Controles , Disfunção Cognitiva/diagnóstico , Humanos , Pessoa de Meia-Idade , Tempo de Reação , Estresse Psicológico/diagnóstico
4.
J Arrhythm ; 37(2): 368-369, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33850578

RESUMO

Prior to ventricular tachycardia ablation, this patient's cardiac implantable electronic device (CIED) was temporarily programmed to backup pacing mode with tachycardia therapies disabled. During radiofrequency energy delivery, the patient developed ventricular fibrillation requiring emergent cardioversion. Electrogram interrogation showed that the CIED switched to noise reversion mode during ablation. The consequent asynchronous pacing resulted in a paced QRS landing on an intrinsic T wave, inducing ventricular fibrillation. This serves as an important reminder that asynchronous pacing consequent to CIED oversensing could occur in any procedure that could cause electromagnetic interference such as radiofrequency cathteter ablation.

5.
JACC Clin Electrophysiol ; 7(1): 85-96, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33478716

RESUMO

OBJECTIVES: This multicenter registry aimed to assess the reproducibility and safety of intentional coronary vein exit and carbon dioxide insufflation to facilitate subxiphoid epicardial access in the setting of ventricular tachycardia ablation. BACKGROUND: Epicardial ablation for ventricular tachycardia is not a widespread technique due to the significant potential complications associated with subxiphoid puncture. The first experience in 12 patients showed that intentional coronary vein exit and carbon dioxide insufflation was technically feasible. METHODS: A branch of the coronary sinus was cannulated by means of a diagnostic JR4 coronary catheter. Intentional perforation at the distal portion of that branch was performed with a high tip load 0.014-inch angioplasty wire. A microcatheter was advanced over the wire into the pericardial space. Carbon dioxide was then insufflated into the pericardial space, allowing direct visualization of the anterior pericardial space to facilitate subxiphoid puncture. RESULTS: Intentional coronary vein exit was attempted in 102 consecutive patients in 16 different centers and successfully completed in 101 patients. Significant pericardial adhesions were confirmed in 3 patients, preventing carbon dioxide insufflation and epicardial ablation. None of the punctures were complicated with inadvertent right ventricular puncture or damage to a coronary artery. Significant bleeding (>80 ml) due to coronary vein exit occurred in 5 patients, without hemodynamic compromise. None of the patients required surgery. CONCLUSIONS: Coronary vein exit and carbon dioxide insufflation can be safely and reproducibly achieved to facilitate subxiphoid pericardial access in the setting of ventricular tachycardia ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Humanos , Sistema de Registros , Reprodutibilidade dos Testes , Taquicardia Ventricular/cirurgia
6.
JACC Clin Electrophysiol ; 6(14): 1783-1793, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357574

RESUMO

OBJECTIVES: The goal of this study was to evaluate the role of dynamic substrate changes in facilitating conduction delay and re-entry in ventricular tachycardia (VT) circuits. BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping. METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP. RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR. CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ventrículos do Coração/cirurgia , Humanos , Masculino , Taquicardia Ventricular/cirurgia
7.
Indian J Psychol Med ; 41(6): 523-528, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772438

RESUMO

BACKGROUND: Attention deficit hyperactive disorder (ADHD) symptoms persisting into adulthood can influence the course and outcome of alcohol use disorders (AUDs). A cross-sectional study was conducted to assess the prevalence of adult ADHD in patients admitted with AUDs in a general hospital setup. METHODS: In this study, 100 consecutive inpatients with alcohol use disorder (AUD) were evaluated for the diagnosis of ADHD. Patients with AUD were assessed with Severity of Alcohol Dependence Questionnaire, Clinical Institute Withdrawal Assessment for Alcohol and Adult ADHD Self Report Scale. Among the subjects who screened positive for adult ADHD on ASRS, diagnosis of adult ADHD was confirmed using the DSM 5 diagnostic interview. Epi-Info Version 7.2 was used for data entry and analysis. Mann Whitney test and Chi-square test (or Fisher's Exact test) were used for statistical analysis. RESULTS: Twenty-one subjects screened positive for adult ADHD. Among them, 19 subjects had a confirmative diagnosis of adult ADHD. Patients with adult ADHD comorbid with AUDs showed accelerated progression towards dependence, and early relapses. CONCLUSIONS: In all, 19% of treatment-seeking inpatients with AUDs have co-morbid adult ADHD. Regular screening of AUD patients for adult ADHD and addressing the psychopathology may improve the treatment outcome.

8.
Int J Cardiol ; 277: 110-117, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30196998

RESUMO

BACKGROUND: To investigate the long term outcomes after catheter ablation (CA) of ventricular tachycardia (VT) in the context of structural heart disease in a multicenter cohort. The impact of different ablation strategies (substrate ablation versus activation guided versus combined) and non-inducibility as an end-point was evaluated. METHODS: Data was pooled from prospective registries at 5 centres over a 5 year period. Success was defined as survival free from recurrent ventricular arrhythmias (VA). Multivariate analysis of factors predicting survival free from VA was analysed by Cox regression. RESULTS: Five hundred sixty-six patients underwent CA for VT. Patients were 64 ±â€¯15 years. Left ventricular ejection fraction was 35 ±â€¯15% and 66% had ischaemic heart disease. At 2.3 (IQR 1.0-4.2) years, success was achieved in 44% after a single procedure, rising to 60% after repeat procedures. Mortality at final follow up was 22%. Multivariate analysis showed that higher left ventricular ejection fraction, younger age, ischaemic heart disease, and non-inducibility of VA predicted long term survival free from VA (all p < 0.05). There was no impact of the approach to ablation. CONCLUSION: CA eliminates VT in a large proportion of patients long term. Ablation strategy did not impact outcome and hence substrate ablation is a reasonable initial strategy. Non-inducibility of VA predicted survival free from VA and may be worth pursuing as a procedural end-point.


Assuntos
Ablação por Cateter/tendências , Determinação de Ponto Final/tendências , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Idoso , Ablação por Cateter/mortalidade , Estudos de Coortes , Determinação de Ponto Final/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Estudos Prospectivos , Sistema de Registros , Taquicardia Ventricular/mortalidade , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 28(11): 1285-1294, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28776822

RESUMO

BACKGROUND: Ripple mapping (RM) displays electrograms as moving bars over a three-dimensional surface displaying bipolar voltage, and has shown in a single-center series to be effective for atrial tachycardia (AT) mapping without annotation of local activation time or window-of-interest assignment. We tested the reproducibility of these findings in operators naïve to RM, using it for the first time in postablation AT. METHODS: Maps were collected with multielectrode catheters and CARTO ConfiDENSE. A diagnosis of the tachycardia mechanism was made using RM and an assessment of operator confidence was made according to a three-grade scale (1 highest-3 lowest). RESULTS: The first 20 patients (64 ± 9 years, median two previous ablations) undergoing RM-guided AT ablation across five sites were studied. High-density maps (2,935 ± 1,328 points) in AT (CL = 296 ± 95 milliseconds) were collected. Macroreentrant ATs bordered by scar or anatomical obstacles were identified in n = 12 (60%), small reentrant ATs around scar in n = 3 (15%), and focal ATs from scar in n = 5 (25%). Diagnostic confidence with RM was grade 1 in n = 13 (65%), where operators felt confident to proceed to ablation without entrainment. Ablation offered the correct diagnosis n = 18 (90%). Retrospective review of the accompanying LAT maps demonstrated potential sources for error related to the window of interest selection, interpolation, and differentiating regions of scar during tachycardia on the voltage map. CONCLUSION: RM was easy to adopt by operators using it for the first time, and identified the correct target for ablation with high diagnostic confidence in most cases of complex AT.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
10.
Am J Cardiol ; 120(7): 1158-1165, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28784235

RESUMO

Age is an adverse prognostic factor in patients with heart failure. We aimed to assess the impact of age and noncardiac co-morbidities in the outcome of patients undergoing cardiac resynchronization therapy (CRT), and determine which of these two factors is the most important predictor of survival. The study involved a single-center retrospective assessment of 697 consecutive CRT implants during a 12-year period. Patient co-morbidity profile was assessed using the Charlson Co-morbidity Index (CCI) and the Charlson Age-Co-morbidity Index (CACI). Predictors of survival free from heart transplantation were assessed. CRT-related complications and cause of death analysis were assessed within tertiles of the CACI. During a mean follow-up of 1,813 ± 1,177 days, 347 patients (49.9%) died and 37 (5.3%) underwent heart transplantation. On multivariate Cox regression, female gender (HR = 0.78, 95% confidence interval [CI] 0.62 to 0.99, p = 0.041), estimated glomerular filtration rate (HR per ml/min = 0.99, 95% CI 0.98 to 0.99, p < 0.001), left ventricular ejection fraction (HR per % = 0.99, 95% CI 0.98 to 1.00, p = 0.022), New York Heart Association class (HR = 1.83, 95% CI 1.53 to 2.20, p < 0.001), presence of left bundle branch block (HR = 0.70, 95% CI 0.56 to 0.87, p = 0.001), and CACI tertile (HR = 1.37, 95% CI 1.18 to 1.59, p < 0.001) were independent predictors of all-cause mortality or heart transplantation. Compared with age and the CCI, the CACI was the best discriminator of all-cause mortality. Inappropriate therapies occurred less frequently in higher co-morbidity tertiles. In conclusion, patient co-morbidity profile adjusted to age impacts on mortality after CRT implantation. Use of the CACI may help refine guideline criteria to identify patients more likely to benefit from CRT.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Medição de Risco/métodos , Fatores Etários , Idoso , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Comorbidade/tendências , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Reino Unido/epidemiologia
11.
Pacing Clin Electrophysiol ; 40(10): 1113-1120, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28734025

RESUMO

BACKGROUND: Dual-site right ventricular pacing (Dual RV) has been proposed as an alternative for patients with heart failure undergoing cardiac resynchronization therapy (CRT) with a failure to deliver a coronary sinus (CS) lead. Only short-term hemodynamic and echocardiographic results of Dual RV are available. We aimed to assess the long-term results of Dual RV and its impact on survival. METHODS: Multicenter retrospective assessment of all CRT implants during a 12-year period. Patients with failed CS lead implantation, treated with Dual RV, were followed and assessed for the primary endpoint of all-cause mortality and/or heart transplant. A control group was obtained from contemporary patients using propensity matching for all available baseline variables. RESULTS: Ninety-three patients were implanted with Dual RV devices and compared with 93 matched controls. During a median of 1,273 days (interquartile range 557-2,218), intention-to-treat analysis showed that all-cause mortality and/or heart transplant was higher in the Dual RV group (adjusted hazard ratio [HR] = 1.66, 95% confidence interval [CI] 1.12-2.47, P = 0.012). As-treated analysis yielded similar results (HR = 1.97, 95% CI 1.31-2.96, P = 0.001). Cardiac device-related infections occurred seven times more frequently in the Dual RV site group (HR = 7.60, 95% CI 1.51-38.33, P = 0.014). Among Dual RV nonresponders, four had their apical leads switched off, five required an epicardial LV lead insertion, a transseptal LV lead was implanted in two, and in nine patients, after reviewing the CS venogram, a new CS lead insertion was successfully attempted. CONCLUSION: Dual RV pacing is associated with worse clinical outcomes and higher complication rates than conventional CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/cirurgia , Marca-Passo Artificial , Pontuação de Propensão , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
12.
J Electrocardiol ; 50(3): 349-352, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28069274

RESUMO

Although cardiac resynchronization therapy (CRT) has become a well-established treatment option for patients with drug-refractory severe systolic heart failure, there has been some evidence of adverse proarrhythmic events. We report a case of a patient with ischemic cardiomyopathy who underwent CRT with a defibrillator for primary prevention of sudden cardiac death. Two years after the implantation, the patient presented with electrical storm, which was completely terminated by modifying the left ventricular (LV) pacing configuration from true to extended bipolar LV pacing. We discuss the possible pathophysiologic mechanisms of this phenomenon through a brief review of the literature on CRT-induced proarrhythmia.


Assuntos
Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Terapia de Ressincronização Cardíaca/métodos , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Terapia Assistida por Computador/métodos , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Humanos , Masculino , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 27(11): 1328-1336, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27566538

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is a risk factor for arrhythmias in patients with heart failure (HF). However, the effects of CKD on ventricular arrhythmia (VA) burden in patients with cardiac resynchronization therapy and defibrillator (CRT-D) devices in a primary prevention setting are unknown. OBJECTIVE: To determine whether baseline CKD is associated with increased risk of VA in patients implanted with primary prevention CRT-D devices. METHODS AND RESULTS: In this retrospective study, 199 consecutive primary prevention CRT-D recipients (2005-2010) were stratified by estimated glomerular filtration rate (eGFR) levels prior to device implantation with 106 (53.2%) ≥CKD III (eGFR < 60 mL/min/1.73 m2 ) (CKD group). CKD group patients were significantly older (70.0 ± 10 years vs. 61.3 ± 12 years, P < 0.05) with higher prevalence of ischemic cardiomyopathy (56.2% vs. 40.2%, P < 0.05). Detected ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes resulting in device therapy occurred significantly more frequently in the CKD group [40/106(37.8%)] than controls [24/93(25.8%)], (odd ratio [OR] = 1.74, 95% confidence interval [CI] = 1.01-3.2, P = 0.05). At 5-year follow-up, interval censored data analysis showed 41% VT/VF incidence in the CKD group compared to 24% incidence in controls (P < 0.05). Cox proportional hazards model identified CKD > III as the only predictor of sustained VA in this group (adjusted hazard ratio [HR] 2.92, CI = 1.39-6.1, P = 0.004). CONCLUSION: Baseline CKD is a strong independent risk factor for VA in primary prevention CRT-D recipients. Further understanding of the underlying arrhythmogenic mechanisms relating to CKD may be of interest to allow appropriate correction and prevention. Device programming in this cohort may need to reflect this increased risk.

14.
Am J Physiol Heart Circ Physiol ; 311(3): H545-54, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27371682

RESUMO

The spatial variation in restitution properties in relation to varying stimulus site is poorly defined. This study aimed to investigate the effect of varying stimulus site on apicobasal and transmural activation time (AT), action potential duration (APD) and repolarization time (RT) during restitution studies in the intact human heart. Ten patients with structurally normal hearts, undergoing clinical electrophysiology studies, were enrolled. Decapolar catheters were placed apex to base in the endocardial right ventricle (RVendo) and left ventricle (LVendo), and an LV branch of the coronary sinus (LVepi) for transmural recording. S1-S2 restitution protocols were performed pacing RVendo apex, LVendo base, and LVepi base. Overall, 725 restitution curves were analyzed, 74% of slopes had a maximum slope of activation recovery interval (ARI) restitution (Smax) > 1 (P < 0.001); mean Smax = 1.76. APD was shorter in the LVepi compared with LVendo, regardless of pacing site (30-ms difference during RVendo pacing, 25-ms during LVendo, and 48-ms during LVepi; 50th quantile, P < 0.01). Basal LVepi pacing resulted in a significant transmural gradient of RT (77 ms, 50th quantile: P < 0.01), due to loss of negative transmural AT-APD coupling (mean slope 0.63 ± 0.3). No significant transmural gradient in RT was demonstrated during endocardial RV or LV pacing, with preserved negative transmural AT-APD coupling (mean slope -1.36 ± 1.9 and -0.71 ± 0.4, respectively). Steep ARI restitution slopes predominate in the normal ventricle and dynamic ARI; RT gradients exist that are modulated by the site of activation. Epicardial stimulation to initiate ventricular activation promotes significant transmural gradients of repolarization that could be proarrhythmic.


Assuntos
Potenciais de Ação/fisiologia , Endocárdio/fisiologia , Sistema de Condução Cardíaco/fisiologia , Ventrículos do Coração , Coração/fisiologia , Função Ventricular , Adulto , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio
15.
Heart ; 102(19): 1533-43, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27234160

RESUMO

OBJECTIVE: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM) and is associated with a high risk of stroke. The efficacy and safety of catheter ablation in this setting is poorly characterised. We aimed to systematically review the existing literature and to perform a meta-analysis to determine the efficacy and safety of catheter ablation of AF in patients with HCM. METHODS: Random-effects meta-analysis of studies comparing HCM versus non-HCM controls. The outcomes of freedom from AF/atrial tachycardia, and acute procedure-related complications were assessed. Studies were searched on MEDLINE, EMBASE, COCHRANE and clinicaltrials.gov. RESULTS: Fourteen studies were considered eligible for the systematic review, of which five were included in the meta-analysis. Freedom from AF/atrial tachycardia relapse was higher in patients without HCM (after a single procedure: 38.7% HCM vs 49.8% controls, OR=2.25, 95% CI 1.09 to 4.64, p=0.03; after ≥1 procedure: 51.8% HCM vs 71.2% controls, OR=2.62, 95% CI 1.52 to 4.51, p=0.0006; I(2)=33% and 26%, respectively). Risk of procedure-related adverse events was low. Repeat procedures (mean difference=0.16, 95% CI 0.0 to 0.32, p=0.05, I(2)=53%) and antiarrhythmic drugs (OR=4.70, 95% CI 2.31 to 9.55, p<0.0001, I(2)=0%) are more frequently needed in patients with HCM to prevent arrhythmia relapse. Sensitivity analyses suggested that the outcome in patients with HCM with less dilated atria and paroxysmal AF may be more comparable to the general population. CONCLUSIONS: The observed complication rate of catheter ablation of AF in patients with HCM was low. Even though the risk of relapse is twofold higher, catheter ablation can be effective in patients with HCM and AF, particularly in patients with paroxysmal AF and smaller atria.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter , Adulto , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Recidiva , Reoperação , Fatores de Risco , Resultado do Tratamento
16.
JACC Clin Electrophysiol ; 2(7): 825-835, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-29759767

RESUMO

OBJECTIVES: The goal of this study was to assess the impact of triventricular pacing (Tri-V) on long-term survival. BACKGROUND: Biventricular pacing (Bi-V) is an important adjunctive treatment in advanced heart failure, but almost one-third of patients experience no improvement with this therapy and are labeled as nonresponders. Adding a third ventricular lead (Tri-V) has been shown to be feasible and provides favorable acute results when assessed by using echocardiographic, hemodynamic, and clinical endpoints. However, the long-term effects of Tri-V pacing and how it affects long-term survival remains unknown. METHODS: This single-center, propensity score-matched cohort study compared 34 patients with advanced heart failure who underwent implantation with Tri-V devices versus 34 control subjects treated with Bi-V pacing. Clinical outcomes during a median of 2,478 days (IQR: 1,183 to 3,214 days) were compared. RESULTS: Tri-V-treated patients compared with Bi-V-treated patients presented with a trend for shorter battery longevity (time to box change, 1,758 ± 360 days vs. 1,993 ± 408 days; p = 0.072). Incidence of lead dislodgement (Tri-V vs. Bi-V, 0.86 vs. 1.10 per 100 patient-years; p = 0.742), device-related infection (Tri-V vs. Bi-V, 1.83 vs. 1.76 per 100 patient-years; p = 0.996), and refractory phrenic nerve capture (Tri-V vs. Bi-V, 0.48 vs. 1.84 per 100 patient-years; p = 0.341) was comparable in the 2 groups. Episodes of ventricular arrhythmia requiring implantable cardioverter-defibrillator intervention occurred more frequently in the Bi-V group versus the Tri-V group (6.55 vs. 16.88 per 100 patient-years; adjusted hazard ratio: 0.31; 95% confidence interval: 0.14 to 0.66; p = 0.002). Lower all-cause mortality and heart transplant was observed in the Tri-V group compared with the Bi-V group (6.99 vs. 11.92 per 100 patient-years; adjusted hazard ratio: 0.44; 95% confidence interval: 0.23 to 0.85; p = 0.015). CONCLUSIONS: Tri-V displayed a similar safety profile compared with Bi-V and was associated with potential benefits regarding long-term survival and ventricular arrhythmia burden.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pontuação de Propensão
17.
J Am Heart Assoc ; 4(11)2015 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-26518666

RESUMO

BACKGROUND: Despite the widespread use of implantable cardioverter-defibrillators (ICDs) in clinical practice, concerns exist regarding ICD lead durability. The performance of specific lead designs and factors determining this in large populations need clarification. METHODS AND RESULTS: The Medline, Embase, and Cochrane Collaboration databases were searched for studies including ≥2 of the most commonly implanted leads. The Mantel-Haenszel random-effects model was used. Seventeen studies were selected, including a total of 49 871 patients-5538 implanted with Durata (St. Jude Medical Inc), 10 605 with Endotak Reliance (Boston Scientific), 16 119 with Sprint Quattro (Medtronic Corp), 11 709 with Sprint Fidelis (Medtronic Corp), and 5900 with Riata (St. Jude Medical Inc)-with follow-up of 136 509 lead-years. Although the Durata lead presented a numerically higher rate, no statistically significant differences in the mean incidence of lead failure (0.29%-0.45% per year) were observed in comparison of the 3 nonrecalled leads. A higher event rate was documented with the Riata (1.0% per-year increase) and Sprint Fidelis (>2.0% per-year increase) leads compared with nonrecalled leads. An indication of increased incidence of Durata lead failure versus Sprint Quattro and Endotak Reliance leads was observed in 1 of 3 included studies, allowing for comparison of purely electrical lead failure, but this requires further evaluation. CONCLUSIONS: Endotak Reliance (8F), Sprint Quattro (8F), and Durata (7F) leads displayed low annual incidence of failure; however, long-term follow-up data are still scarce. More data are needed to clarify the performance and safety of the Durata lead.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Distribuição de Qui-Quadrado , Cardioversão Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Estudos Observacionais como Assunto , Razão de Chances , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Indian J Psychiatry ; 57(Suppl 2): S303-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26330648

RESUMO

Research on psychotropic medications during pregnancy and lactation is limited as often involves complex ethical issues. Information on safety of psychotropic drugs during these critical phases is either inconclusive or undetermined. Many women with severe mental illness have unplanned pregnancies and require antipsychotic medication during pregnancy and lactation. Multiple issues have to be considered while choosing safe treatments for pregnant and lactating women and the best approach is to individualize the treatment. Medication should be guided primarily by its safety data and by the psychiatric history of the patient. Important issues to be kept in mind include pre-pregnancy counseling for all women, including planning pregnancies; folate supplementation, discussion with patient and family regarding options, and active liaison with obstetricians, ultrasonologists and pediatricians. Whenever possible, non-pharmacological approaches should be used in addition.

19.
Circ Arrhythm Electrophysiol ; 8(5): 1017-29, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26082515

RESUMO

BACKGROUND: Ablation of complex fractionated atrial electrograms (CFAEs) has been proposed as a strategy to improve outcomes in atrial fibrillation (AF) catheter ablation, but the use of this technique remains contentious. We aimed to assess the impact of CFAE ablation in addition to pulmonary vein isolation (PVI) in patients undergoing ablation for AF. METHODS AND RESULTS: We performed a random effects meta-analysis of studies comparing PVI versus PVI+CFAE ablation. The outcomes of freedom from AF/atrial tachycardia after 1 or several ablation procedures and acute procedural-related complications were assessed. Studies were searched on MEDLINE, EMBASE, COCHRANE, and clinicaltrials.gov, and sensitivity analyses were performed. Thirteen studies including a total of 1415 patients were considered eligible. Additional ablation of CFAEs resulted in no improvement in mid-term procedural outcome or freedom from AF or atrial tachycardia (odds ratio [OR], 0.80; 95% confidence interval [CI], 0.58-1.10; P=0.17). Sensitivity analysis of 398 paroxysmal AF ablation procedures showed no incremental benefit of CFAE ablation (OR, 0.80; 95% CI, 0.46-1.38; P=0.42). PVI+CFAE ablation versus PVI alone did not improve the overall rate of freedom from AF or atrial tachycardia in patients with persistent AF (OR, 1.01; 95% CI, 0.63-1.64; P=0.96) or longstanding persistent AF (OR, 0.84; 95% CI, 0.24-2.96; P=0.79). There was no increase in procedural-related adverse events (OR, 1.06; 95% CI, 0.41-2.75; P=0.91). CONCLUSIONS: Despite the apparent safety of this technique, CFAE ablation did not improve freedom from AF/atrial tachycardia in patients with paroxysmal or persistent AF. The role of CFAE ablation in addition to PVI should be questioned and other alternatives assessed to improve the outcome of AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Cirurgia Assistida por Computador/métodos , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Complicações Pós-Operatórias , Resultado do Tratamento
20.
J Clin Diagn Res ; 9(4): ZC52-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26023644

RESUMO

BACKGROUND AND OBJECTIVES: The purpose of the present study was to determine the microbial atmospheric contamination during initial periodontal treatment using a modern piezoelectric scaler and to evaluate the efficacy of two commercially available mouth rinses (0.2% Chlorhexidine mouth rinse and Listerine) in reducing bacterial contamination when used as a pre-procedural rinse, with and without high volume evacuation (Aerosol reduction device). MATERIALS AND METHODS: Subjects for the study were selected from the outpatient Department of Periodontics, Sri Siddhartha Dental College and Hospital, Tumkur, India. Total 60 patients were taken for the study and on the basis of inclusion and exclusion criteria's they were divided into three groups. The sampling was carried out in two stages before and after implementing a set protocol. Total duration of study was four months. MICROBIOLOGICAL EVALUATION: The samples (blood agar plates) were transported immediately to the Department of Microbiology, Sri Siddhartha Medical College, Tumkur for: Identification of microorganisms as per standard procedures (Gram stain, Biochemical Test, Species Identification).Counting the number of colonies formed on blood agar plates using colony counter unit. RESULTS: Out of all the three pre-procedural rinses 0.2% w/v Chlorhexidine is the best in reducing aerobic bacteria (CFU) followed by Listerine and then Water. CONCLUSION: The following conclusion was drawn that the use of pre-procedural rinses along with the use of high volume suction apparatus significantly reduced the aerosol contamination and hence chances of cross-infection in the dental units.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA