Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Hip Int ; 31(1): 115-124, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31547719

RESUMO

BACKGROUND: Various factors, other than the quality of surgery, may influence clinical outcomes of hip fracture patients. We aimed to evaluate the relative impact of several factors on functional outcome, quality of life, re-fracture and mortality rates following surgery for hip fractures. METHODS: We studied 498 (62.2%) women and 302 (37.8%) men with a mean age of 81.3 years (range, 60-95) with hip fractures (femoral neck and pertrochanteric). The mean follow-up was 74 months (range 58-96). Various patient-related and surgery-related parameters were recorded and correlated to both objective and subjective mobility, functional recovery and quality of life scales. Mortality and re-fracture rates were also evaluated. RESULTS: Using multiple regression analysis, age >80 years (p = 0.000; 95% CI, 1.077-1.143) and ASA score III and IV (p = 0.000; 95% CI, 2.088-3.396) (both non-modifiable factors) both proved to be independent (s.s.) factors affecting mortality rates. Age <80 years (p = 0.000; 95% CI, 0.932-0.974), surgery delay less (modifiable factor) than 48 hours (p = 0.046; 95% CI, 0.869-0.999), low dementia CDR index (p = 0.005; 95% CI, 0.471-0.891) (non-modifiable factor), and osteoporosis medical treatment (modifiable factor) (p = 0.006; 95% CI, 0.494-0.891) were shown to be independent (s.s.) factors affecting HOOS-symptoms. Osteoporosis medical treatment used proved to be an independent (s.s.) factor affecting HOOS-daily activities (p = 0.049; 95% CI, 0.563-1.000) and quality of life (E-Qol-5D) (p = 0.036; 95% CI, 0.737-1.325). CONCLUSIONS: A hip fracture patient aged <80 years old, with an ASA I-II, with low dementia CDR index and on osteoporosis medication has a better chance of an improved outcome (winner patient).


Assuntos
Fraturas do Quadril , Osteoporose , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/epidemiologia , Qualidade de Vida , Recuperação de Função Fisiológica
2.
Knee ; 26(4): 838-846, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31118135

RESUMO

BACKGROUND: To present the long-term clinical and radiological outcomes of the Genesis I posterior cruciate-retaining total knee arthroplasty (TKA) (Smith & Nephew Orthopaedics, Memphis, TN, USA) (one of the first designed with an asymmetric tibial tray). METHODS: Prospectively collected data from 117 cemented TKAs performed on 95 patients were evaluated using this design, with a mean follow-up of 21.5 years (range, 18-26). Failures, complication rates, and clinical (both subjective and objective) and radiological outcomes were assessed for all patients. RESULTS: Seven failures occurred (wear and structural failure of the polyethylene insert) and six revision surgeries were performed at a mean of 10 years (range, three to 14) from the index operation. No revision of either the femoral or tibial components for aseptic loosening was performed. Survivorship analysis showed a cumulative success rate of 93.53% (95% CI, 92.75-94.32%) at 20 and 25 years, with revision for any reason as an end point. All patients showed a statistically significant improvement (P = 0.001) in the Knee Society and Oxford knee rating scores. CONCLUSIONS: This study demonstrated satisfactory long-term clinical outcomes for this TKA design, with revisions being related to polyethylene wear structural failure.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos
3.
Injury ; 46(2): 378-83, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25541417

RESUMO

Numerous high quality studies have shown the positive effects of various osteoporotic medical treatment regimens on bone mass and on the reduction of risk for new spinal, hip and non-spinal fractures in osteoporotic patients. However, the effect of osteoporotic treatment on the functional and clinical outcome of patients who have sustained hip fractures and been treated surgically has not yet been addressed. Five hundred and twenty patients out of 611 who were admitted (2009-2011), operated on due to a hip fracture and completed their follow-up evaluations were included in this study. Data related to functional outcome scores, re-fracture rate, quality of life and mortality rate were prospectively recorded, analysed and correlated to osteoporotic medical treatment. There were 151 (25%) men and 369 (71%) women with a mean age of 80.7 years (range, 60 to 90 years). At a mean follow-up of 27.5 months (range, 24 to 36 months) a mortality rate of 23.6% at 2 years was recorded. Mean values of functional and quality of life scores were found to have progressively improved within two years after surgery. Seventy-eight (15%) patients were taking osteoporotic treatment before their hip fracture and 89 (17.1%) started afterwards. Osteoporotic treatment proved to be an important predictor of functional recovery (all p values<0.05), re-fracture rate (p=0.028) and quality of life (EQ-5D, all dimensions, p values<0.05). Osteoporotic treatment did not affect post-fracture mortality rates. Osteoporotic treatment taken before or initiated after fracture is a strong predictor of functional and clinical outcome in patients with hip fractures treated surgically.


Assuntos
Conservadores da Densidade Óssea/uso terapêutico , Cálcio/uso terapêutico , Fraturas do Quadril/prevenção & controle , Osteoporose/tratamento farmacológico , Vitamina D/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Análise Custo-Benefício , Suplementos Nutricionais , Feminino , Seguimentos , Grécia/epidemiologia , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Recidiva
4.
J Orthop Surg (Hong Kong) ; 20(3): 409-13, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23255659

RESUMO

Post-traumatic premature closure of the distal fibular growth plate is a rare entity leading to shortening of the lateral malleolus. We report on a 14-year old boy who presented with a 4-year history of worsening, diffuse discomfort and swelling of his left ankle, as well as fibular shortening and talar malreduction. He had sustained a distal tibial fracture 4 years earlier and had been treated with closed reduction. He reported instability of the ankle and difficulty with running. There was 1-cm shortening of the left fibula, 1-cm shortening of the proximal fibula, and slight widening of the medial clear space. Both tibial and fibular growth plates were already closed and the left ankle joint space was slightly narrowed. He was treated with late fibular lengthening and autogenous iliac crest tricortical bone grafting and achieved anatomic restoration of the distal tibiofibular relationship. At one-year follow-up, the ankle-hindfoot score had improved from 69 to 100.


Assuntos
Alongamento Ósseo , Fíbula/fisiopatologia , Fíbula/cirurgia , Fraturas da Tíbia/complicações , Adolescente , Articulação do Tornozelo/diagnóstico por imagem , Autoenxertos , Desenvolvimento Ósseo/fisiologia , Alongamento Ósseo/métodos , Transplante Ósseo , Lâmina de Crescimento/diagnóstico por imagem , Lâmina de Crescimento/fisiopatologia , Humanos , Ílio/transplante , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Imageamento por Ressonância Magnética , Masculino , Osteotomia , Radiografia , Tálus/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem
5.
Hip Int ; 19(4): 301-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20041375

RESUMO

We report the clinical and radiological outcome of 99 Zweymuller metal on metal total hip arthroplasties in 84 patients followed up prospectively for a mean period of 9.5 (range, 6-15) years. There were 29 (34.5%) male and 55 (65.5%) female patients with a mean age of 62.85 years (range, 50-70 years) at the time of surgery. All patients had osteoarthritis. One acetabular component and one stem were revised due to aseptic loosening. One femoral stem was revised due to a periprosthetic fracture. HHS score improved from a preoperative mean of 62.56 points (SD 8.87) to a final postoperative follow-up mean of 93.48 (SD 7.7). Cumulative success rate for both implants at 13 years, with aseptic loosening as the end point, was 97.05%, while for both implants at 13 years, with revision for any reason as the end point, it was 91.17%. Satisfactory results were observed with the use of this prosthesis.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Idoso , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Radiografia , Reoperação/estatística & dados numéricos
6.
Acta Orthop Belg ; 73(3): 306-14, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17715719

RESUMO

This is a prospective case series, in which the outcome of shoulder hemiarthroplasty in recent three- and four-part fractures of the proximal humerus was evaluated in patients over 65 years of age. From February 1993 to October 2002, 51 patients with 3- or 4-part fractures of the proximal humerus were entered into the study. The criteria for inclusion were age over 65 years and 3- or 4- part displaced fracture. The mean age of the patients was 73 years (range: 65 to 84). The mean follow-up was 5.5 years (range: 2 to 12). According to the Constant-Murley scale, the results were satisfactory or very satisfactory for 74% of the patients. Thirty nine patients (78%) experienced mild or no pain, 50% achieved active anterior elevation greater than 120 degrees, while 40% had active lateral elevation of more than 120 degrees. None of the patients experienced complete recovery of strength and full range of motion. Thirty four patients were able to resume all their daily activities. There were complications in 26% of the patients. Assessment following the Constant-Murley scale demonstrated that two thirds of the patients were pain free and regained a wide range of shoulder movement, while one third resumed their pre-fracture activities to a great extent. The majority of the patients did not recover normal strength.


Assuntos
Artroplastia de Quadril , Fraturas do Úmero/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
8.
Am J Orthop (Belle Mead NJ) ; 32(9): 452-4, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14560827

RESUMO

We report a case of successful treatment of a very rare triplane fracture of the proximal tibia in an adolescent boy. The fracture was internally fixed using cannulated Herbert screws. The final result was excellent.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia/cirurgia , Adolescente , Parafusos Ósseos , Humanos , Masculino , Radiografia , Fraturas da Tíbia/diagnóstico por imagem
9.
J Orthop Trauma ; 17(8): 574-7, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14504579

RESUMO

We present a salvage technique for distal femoral interlocking under direct vision through a window in the anterior femoral cortex in a subgroup of six patients, among those presented to our institution during the last 10 years with a femoral shaft fracture treated with reamed, locked intramedullary nailing. The common characteristic of these patients was the performance of distal locking under direct vision through a small window in the anterior femoral cortex because of intraoperative dysfunction of the image intensifier. Screw insertion was successful in all cases. All fractures and all cortical windows healed uneventfully. No postoperative fractures occurred through the cortical defect. This technique, despite being a salvage one, has proven a safe alternative to the common distal targeting techniques. It can be used when an image intensifier is unavailable without jeopardizing the excellent clinical and radiographic outcome of reamed locked nailing of femoral shaft fractures.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Procedimentos Ortopédicos/métodos , Adulto , Desenho de Equipamento , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA