RESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery (P=0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P=0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P<0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P=0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients (P<0.001) and lower rates of severe prosthesis-patient mismatch (P<0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT02701283.
RESUMO
Transcatheter aortic valve replacement (TAVR) has undergone rapid expansion, emerging as a viable therapeutic option for low-risk patients in lieu of surgical aortic valve replacement. This paper aims to provide a review of the scientific evidence concerning TAVR in low-risk patients, encompassing both observational and clinical trial data. Furthermore, a substantial proportion of low-risk patients possesses a bicuspid aortic valve, necessitating careful examination of the pertinent anatomic and clinical considerations to TAVR that is highlighted in this review. Additionally, the review expands upon some of the unique challenges associated with alternate access in low-risk patients evaluated for TAVR. Last, this review outlines the pivotal role of a multidisciplinary heart team approach in the execution of all TAVR procedures and the authors' vision of 'minimalist TAVR' as a new era in low-risk TAVR.
RESUMO
Coronary calcification represents a significant technical challenge in percutaneous coronary intervention and is associated with worse clinical outcomes. Fortunately, a number of balloon-assisted technologies are available to aid in the management of coronary calcification before stenting. Adequate lesion preparation is crucial in the successful management of calcified coronary lesions. Balloon-based techniques can be a safe and effective method of lesion preparation and, as such, are an integral part of an interventionalist's armamentarium. In this mini-review, we focus on the use of non-compliant balloons, super high-pressure non-compliant balloons, cutting balloons, scoring balloons and intravascular lithotripsy.
RESUMO
BACKGROUND: While transcatheter aortic valve replacement (TAVR) has broadened treatment options for critically ill patients, outcomes among those with concomitant cardiogenic shock (CS) are not well-explored. METHODS: We conducted a comprehensive search of major databases for studies comparing outcomes following TAVR in patients with and without CS since inception up to October 31, 2023. Our meta-analysis included five non-randomized observational. Dichotomous outcomes were assessed using the Mantel-Haenszel method (risk ratio, 95 % CI), and continuous outcomes were evaluated using mean difference and 95 % CI with the inverse variance method. Statistical heterogeneity was determined using the inconsistency test (I2). RESULTS: Among 26,283 patients across five studies, 30-day mortality was higher in the CS group (7267 patients; 27.6 %) compared to those without CS (OR 3.41, 95 % CI [2.01, 5.76], p < 0.01), as well as 30-day major vascular complications (OR 1.72, 95 % CI [1.54, 1.92], p < 0.01). At 1-year follow-up, there was no statistically significant difference in mortality rates between the compared groups (OR 2.68, 95 % CI [0.53, 13.46], p = 0.12). No significant between-group differences were observed in the likelihood of 30-day aortic valve reintervention (OR 3.20, 95 % CI [0.63, 16.22], p = 0.09) or post-TAVR aortic insufficiency (OR 0.91, 95 % CI [0.33, 2.51], p = 0.73). Furthermore, 30-day stroke, pacemaker implantation, and in-hospital major bleeding were comparable between both cohorts. CONCLUSION: Among patients undergoing TAVR, short-term mortality is higher but one-year outcomes are similar when comparing those with, to those without, CS. Future studies should examine whether TAVR outcomes are improved when the procedure is delayed to optimize CS and when delay is not possible, whether particular management strategies lead to more favorable periprocedural outcomes.
RESUMO
BACKGROUND: This study aimed to investigate the association between index trial participation status and 30-day unplanned readmission rates, causes, and outcomes in acute coronary syndrome (ACS) patients. METHODS: The National Readmission Database was analysed for all index hospitalizations with a principal diagnosis of ACS between October 2015 to November 2019, stratified by index trial participation status (International Classification of Diseases - 10th edition code: Z00.6). The 30-day unplanned readmission rates, causes and outcomes were analysed, including the assessment of factors associated with readmission. Multivariable regression analyses were reported as adjusted odds ratios (aOR) with 95 % confidence intervals (95 % CI). All analyses were weighted and utilized hierarchical multi-level organization. RESULTS: A total of 2,066,328 cases with a principal diagnosis of ACS were included in the study, of which there were 4061 trial participants (0.2 %) and 189,240 (9.2 %) cases experienced unplanned 30-day readmission. Rates of unplanned 30-day readmission were similar between trial participants and non-participants (9.8 % vs. 9.2 %, p = 0.16). Consistently, after multivariable adjustment, there was no significant association between trial participation and unplanned 30-day readmissions (aOR 0.96, 95 % CI 0.86-1.07, p = 0.45). Compared with trial participants, the majority of readmissions in non-participants were related to cardiovascular conditions (55.2 % vs. 46.7 %, p = 0.005, respectively). There was no significant difference in all-cause mortality (5.5 % vs. 4.6 %, p = 0.368, respectively), but trial participants were more likely to develop major bleeding (3.5 % vs. 2.1 %, p = 0.044), ischemic stroke (4.0 % vs. 2.1 %, p = 0.008) and haemorrhagic stroke (2.0 % vs. 0.6 %, p < 0.001) at readmissions. CONCLUSION: Overall rates of unplanned 30-day readmissions after ACS are similar between trial participants and non-participants, but non-participation in trials was associated with a higher likelihood of cardiovascular readmission.
RESUMO
BACKGROUND: Patients with low HEART (History, Electrocardiogram, Age, Risk factors, and Troponin level) risk scores who are discharged from the emergency department (ED) may present clinical challenges and diagnostic dilemmas. The use of downstream non-invasive stress imaging (NISI) tests in this population remains uncertain. Therefore, this study aims to investigate the value of NISI in risk stratification and predicting cardiac events in patients with low-risk HEART scores (LRHSs). METHODS: We prospectively included 1384 patients with LRHSs between March 2019 and March 2021. All the patients underwent NISI (involving myocardial perfusion imaging/stress echocardiography). The primary endpoints included cardiac death, non-fatal myocardial infarction and unplanned coronary revascularisation. Secondary endpoints encompassed cardiovascular-related admissions or ED visits. RESULTS: The mean patient age was 64±14 years, with 670 (48.4%) being women. During the 634±104 days of follow-up, 58 (4.2%) patients experienced 62 types of primary endpoints, while 60 (4.3%) developed secondary endpoints. Multivariable Cox models, adjusted for clinical and imaging variables, showed that diabetes (HR: 2.38; p=0.008), HEART score of 3 (HR: 1.32; p=0.01), history of coronary artery disease (HR: 2.75; p=0.003), ECG changes (HR: 5.11; p<0.0001) and abnormal NISI (HR: 16.4; p<0.0001) were primary endpoint predictors, while abnormal NISI was a predictor of secondary endpoints (HR: 3.05; p<0.0001). CONCLUSIONS: NISI significantly predicted primary cardiac events and cardiovascular-related readmissions/ED visits in patients with LRHSs.
Assuntos
Dor no Peito , Ecocardiografia sob Estresse , Serviço Hospitalar de Emergência , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Medição de Risco/métodos , Estudos Prospectivos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Ecocardiografia sob Estresse/métodos , Idoso , Imagem de Perfusão do Miocárdio/métodos , Fatores de Risco , Prognóstico , Seguimentos , Valor Preditivo dos Testes , Eletrocardiografia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/diagnóstico por imagemRESUMO
BACKGROUND: There is limited data on predicting successful chronic total occlusion crossing using primary antegrade wiring (AW). OBJECTIVES: The aim of this study was to develop and validate a machine learning (ML) prognostic model for successful chronic total occlusion crossing using primary AW. METHODS: We used data from 12,136 primary AW cases performed between 2012 and 2023 at 48 centers in the PROGRESS CTO registry (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention; NCT02061436) to develop 5 ML models. Hyperparameter tuning was performed for the model with the best performance, and the SHAP (SHapley Additive exPlanations) explainer was implemented to estimate feature importance. RESULTS: Primary AW was successful in 6,965 cases (57.4%). Extreme gradient boosting was the best performing ML model with an average area under the receiver-operating characteristic curve of 0.775 (± 0.010). After hyperparameter tuning, the average area under the receiver-operating characteristic curve of the extreme gradient boosting model was 0.782 in the training set and 0.780 in the testing set. Among the factors examined, occlusion length had the most significant impact on predicting successful primary AW crossing followed by blunt/no stump, presence of interventional collaterals, vessel diameter, and proximal cap ambiguity. In contrast, aorto-ostial lesion location had the least impact on the outcome. A web-based application for predicting successful primary AW wiring crossing is available online (PROGRESS-CTO website) (https://www.progresscto.org/predict-aw-success). CONCLUSIONS: We developed an ML model with 14 features and high predictive capacity for successful primary AW in chronic total occlusion percutaneous coronary intervention.
Assuntos
Oclusão Coronária , Aprendizado de Máquina , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Sistema de Registros , Humanos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Masculino , Feminino , Resultado do Tratamento , Doença Crônica , Idoso , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Reprodutibilidade dos Testes , Fatores de Risco , Técnicas de Apoio para a Decisão , Fatores de TempoRESUMO
Previous studies have shown the safety of early discharge pathways in selected patients and using selected transcatheter heart valves. Hence, we sought to evaluate the safety of next-day discharge (NDD) in patients who underwent transfemoral transcatheter aortic valve implantation (TF-TAVI) with the ACURATE neo/neo2 (Boston Scientific, Marlborough, Massachusetts) self-expanding aortic bioprosthesis. Patients who underwent TF-TAVI between January 2018 and April 2023 were prospectively included. Patients were stratified into 3 groups according to discharge times within 24 hours (NDD), between 24 and 48 hours, and those discharged >48 hours after TAVI. The primary outcome was the first unplanned readmission at 30 days after TAVI. Log-rank test was used to assess the differences in the outcome of interest between the groups. A total of 368 all-comers were included in this study. According to discharge times, 204 patients followed NDD, 69 patients 24 to 48 hours discharge, and 95 patients >48 hours discharge after TAVI. The mean age was 84 ± 6.3 years and 61% were women, without differences between the groups. The mean Society of Thoracic Surgeons score was lower in those with NDD versus 24 to 48 hours and >48 hours (2.9 ± 1.0, 3.2 ± 1.2, and 3.4 ± 1.4, respectively, p = 0.014). There were no differences between the groups in terms of preprocedural right bundle branch block or pacemaker. The need for new permanent pacemaker implantation was the leading postprocedural complication; it occurred more frequently in the >48 hours group than the 24 to 48 hours, and <24 hours groups (24% vs 8.6% and 2.2%, p <0.001). There were 5 strokes (1.4%) and all of them occurred in the >48 hours group (p = 0.005). At 30 days after discharge, there were no deaths and no differences in all-cause readmissions (9.3% in <24 hours, 8.6% in 24 to 48 hours, and 19% in >48 hours, log-rank p = 0.087). The readmission rates for new permanent pacemaker implantation requirement were 3.3% (n = 6) in NDD, 0% in 24 to 48 hours, and 1.6% (n = 5) in the >48 hours groups (p = 0.27). In conclusion, in unselected patients who underwent TF-TAVI with the ACURATE neo/neo2 self-expanding bioprosthesis, the NDD pathway is feasible and appears to be safe, without an increased risk of death or all-cause rehospitalization through 30 days after hospital discharge.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Alta do Paciente , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Readmissão do Paciente/estatística & dados numéricos , Desenho de Prótese , Idoso , Complicações Pós-Operatórias/epidemiologia , Fatores de Tempo , Valva Aórtica/cirurgiaRESUMO
Infective endocarditis involving the aortic root is associated with a high degree of morbidity and mortality. Native aortic root infections can develop from aggressive organisms or from delays in diagnosis or definitive care, whereas prosthetic valve infections commonly result in extensive destruction of the aortic root and neighboring structures. Early detection, tailored antibiotic therapy, thoughtful pre-operative planning, and multidisciplinary heart team management are the keys to optimizing patient outcomes. Aggressive and complete surgical debridement are mandatory prior to aortic root reconstruction. Surgical experience and patient-centered decision making are critical in selecting the optimal reconstructive strategy for the aortic root and adjacent structures. Supplementary Information: The online version contains supplementary material available at 10.1007/s12055-023-01604-6.
RESUMO
INTRODUCTION: Cardiac imaging is one of the main components of the etiological investigation of ischemic strokes. However, basic and advanced cardiac imaging remain underused in most stroke centers globally. Computed tomography angiography (CTA) of the supra-aortic and intracranial arteries is the most frequent imaging modality applied during the evaluation of patients with acute ischemic stroke to identify the presence of a large vessel occlusion. Recent evidence from retrospective observational studies has shown a high detection of cardiac thrombi, ranging from 6.6 to 17.4%, by extending a CTA a few cm below the carina to capture cardiac images. However, this approach has never been prospectively compared against usual care in a randomized controlled trial. The Extended Computed Tomography Angiography for the Successful Screening of Cardioaortic Thrombus in Acute Ischemic Stroke and TIA (DAYLIGHT) prospective, randomized, controlled trial evaluates whether an extended CTA (eCTA) + standard-of-care stroke workup results in higher detection rates of cardiac and aortic source of embolism compared to standard-of-care CTA (sCTA) + standard-of-care stroke workup. METHODS: DAYLIGHT is a single-center, prospective, randomized, open-blinded endpoint trial, aiming to recruit 830 patients with suspected acute ischemic stroke or transient ischemic attack (TIA) being assessed under acute code stroke at the emergency department or at a dedicated urgent stroke prevention clinic. Patients are randomized 1:1 to eCTA versus sCTA. The eCTA expands image acquisition caudally, 6 cm below the carina. All patients receive standard-of-care cardiac imaging and diagnostic stroke workup. The primary efficacy endpoint is the diagnosis of a cardioaortic thrombus after at least 30 days of follow-up. The primary safety endpoint is door-to-CTA completion time. The diagnosis of a qualifying ischemic stroke or TIA is independently adjudicated by a stroke neurologist, blinded to the study arm allocation. Patients without an adjudicated ischemic stroke or TIA are excluded from the analysis. The primary outcome events are adjudicated by a board-certified radiologist with subspecialty training in cardiothoracic radiology and a cardiologist with formal training in cardiac imaging. The primary analysis is performed according to the modified intention-to-diagnose principle and without adjustment by logistic regression models. Results are presented with odds ratios and 95% confidence intervals. CONCLUSION: The DAYLIGHT trial will provide evidence on whether extending a CTA to include the heart results in an increased detection of cardioaortic thrombi compared to standard-of-care stroke workup.
RESUMO
INTRODUCTION: It is unknown how cardiac imaging studies are used by neurologists to investigate cardioembolic sources in ischemic stroke patients. METHODS: Between August 12, 2023, and December 8, 2023, we conducted an international survey among neurologists from Europe, North America, South America, and Asia, to investigate the frequency of utilization of cardiac imaging studies for the detection of cardioembolic sources of ischemic stroke. Questions were structured into deciles of percentage utilization of transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), ECG-gated cardiac computed tomography (G-CCT), and cardiac magnetic resonance imaging (CMRI). We estimated the weighted proportion (
RESUMO
This case report describes the rare occurrence of a ventricular septal defect (VSD) after transcatheter aortic valve implantation (TAVI) in an 88-year-old male patient with aortic stenosis and other comorbidities. Initially asymptomatic, the patient was discharged but readmitted 2 weeks later with decompensated heart failure. Transesophageal echocardiography (TEE) revealed an increase in the size of the VSD and right ventricular dilation. Surgical intervention was chosen over percutaneous closure due to the patient's condition. A bovine pericardial patch was successfully used for repair. This case highlights the importance of vigilant post-TAVI monitoring and individualized treatment for TAVI-related complications.
Assuntos
Estenose da Valva Aórtica , Comunicação Interventricular , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Comunicação Interventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Bovinos , Animais , Resultado do TratamentoRESUMO
INTRODUCTION: The aim of this study is to analyze the diagnostic value of global longitudinal strain (GLS) in detecting inducible myocardial ischemia in patients with chest pain undergoing treadmill contrast-enhanced stress echocardiography (SE). METHODS: We retrospectively enrolled all patients who underwent invasive coronary angiography after treadmill contrast-enhanced SE. Rest and peak-stress myocardial GLS, segmental LS, and LS of 4-chamber (CH), 2-CH, and 3-CH views were reported. Luminal stenosis of more than 70% or fractional flow reserve (FFR) of < 0.8 was considered significant. RESULTS: In total 33 patients were included in the final analysis, among whom sixteen patients (48.4%) had significant coronary artery stenosis. Averaged GLS, 3-CH, and 4-CH LS were significantly lower in patients with critical coronary artery stenosis compared to those without significant stenosis (-17.1 ± 7.1 vs. -24.2 ± 7.2, p = 0.041), (-18.2 ± 8.9 vs. -24.6 ± 8.2, p = 0.045) and (-14.8 ± 6.2 vs. -22.8 ± 7.8, p = 0.009), respectively. Receiver operating characteristic (ROC) analysis of ischemic and non-ischemic segments demonstrated that a cut-off value of -20% of stress LS had 71% sensitivity and 60% specificity for ruling out inducible myocardial ischemia (Area under the curve was AUC = 0.72, P < 0.0001). CONCLUSION: Myocardial LS measured with treadmill contrast-enhanced stress echocardiography demonstrates potential value in identifying patients with inducible myocardial ischemia.
Assuntos
Meios de Contraste , Angiografia Coronária , Estenose Coronária , Ecocardiografia sob Estresse , Valor Preditivo dos Testes , Humanos , Masculino , Feminino , Ecocardiografia sob Estresse/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Meios de Contraste/administração & dosagem , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Reprodutibilidade dos Testes , Contração Miocárdica , Função Ventricular Esquerda , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Reserva Fracionada de Fluxo MiocárdicoRESUMO
Background: Patients with tricuspid bioprosthetic structural valve degeneration (SVD) often present with right ventricular enlargement and severe dysfunction, which cause a higher risk for redo cardiac surgery. In 2019, our center innovated using the J-valve system for valve-in-valve (ViV) implantation to treat tricuspid bioprosthetic SVD. The purpose of this study was to summarize the clinical effect after 1-year follow-up. Case Description: From April 2019 to October 2019, two cases of tricuspid bioprosthetic dysfunction were treated with the J-valve system. Both patients were male, aged 46 and 67 years, respectively. The preoperative evaluation showed that the risk of conventional redo open heart surgery was high. The J-valve implantation was successful in both cases. One patient had slight valve displacement when the transporter was withdrawn during the operation, and a second J-valve was implanted in an ideal position. There was no death, no delayed valve displacement, and no readmission during the follow-up period of 12 months. In both cases, there was an absence of trace tricuspid regurgitation. After 6 months of anticoagulation with warfarin, the patients were converted to long-term aspirin treatment. Conclusions: The ViV technique with J-valve is feasible and effective in treating tricuspid bioprosthetic SVD in high-risk patients, avoiding cardiopulmonary bypass and conventional thoracotomy injury.
RESUMO
BACKGROUND: To date, there has been no independent core lab angiographic analysis of patients with COVID-19 and STEMI. The study characterized the angiographic parameters of patients with COVID-19 and STEMI. METHODS: Angiograms of patients with COVID-19 and STEMI from the North American COVID-19 Myocardial Infarction (NACMI) Registry were sent to a Core Laboratory in Vancouver, Canada. Culprit lesion(s), Thrombolysis In Myocardial Infarction (TIMI) flow, Thrombus Grade Burden (TGB), and percutaneous coronary intervention (PCI) outcome were assessed. RESULTS: From 234 patients, 74% had one culprit lesion, 14% had multiple culprits and 12% had no culprit identified. Multivessel thrombotic disease and multivessel CAD were found in 27% and 53% of patients, respectively. Stent thrombosis accounted for 12% of the presentations and occurred in 55% of patients with previous coronary stents. Of the 182 who underwent PCI, 60 (33%) had unsuccessful PCI due to post-PCI TIMI flow <3 (43/60), residual high thrombus burden (41/60) and/or thrombus related complications (27/60). In-hospital mortality for successful, partially successful, and unsuccessful PCI was 14%, 13%, and 27%, respectively. Unsuccessful PCI was associated with increased risk of in-hospital mortality (risk ratio [RR] 1.96; 95% CI: 1.05-3.66, P = .03); in the adjusted model this estimate was attenuated (RR: 1.24; 95% CI: 0.65-2.34, P = .51). CONCLUSION: In patients with COVID-19 and STEMI, thrombus burden was pervasive with notable rates of multivessel thrombotic disease and stent thrombosis. Post-PCI, persistent thrombus and sub-optimal TIMI 3 flow rates led to one-third of the PCI's being unsuccessful, which decreased over time but remained an important predictor of in-hospital mortality.
Assuntos
COVID-19 , Angiografia Coronária , Intervenção Coronária Percutânea , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , COVID-19/complicações , COVID-19/terapia , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Mortalidade Hospitalar , SARS-CoV-2 , Trombose Coronária/diagnóstico por imagem , Canadá/epidemiologiaRESUMO
AIMS: Patients with cancer are at increased cardiovascular (CV) risk. We aimed to compare the recommended and observed statin use among individuals with and without cancer. METHODS AND RESULTS: Using three 2-year cycles from the National Health and Nutrition Examination Survey (2013-18), we analysed data from 17 050 US adults. We compared the prevalence of Class 1 statin recommendations and use between individuals with and without cancer, overall, and among different demographic groups. Individuals with a history of cancer were older and had a higher burden of comorbidities. Stratified by age groups, they were more likely to have a secondary prevention indication compared with individuals without cancer but not a primary prevention indication for statin. Among individuals with an indication for statin therapy, the prevalence of statin use was higher in the cancer group compared with those without cancer (60.8% vs. 47.8%, P < 0.001), regardless of sex, type of indication (primary vs. secondary prevention), and education level. However, the higher prevalence of statin use in the cancer group was noted among younger individuals, ethnic minorities, and those with lower family income. CONCLUSION: Our finding highlights the importance of optimization of CV health in patients with cancer, as individuals with cancer were more likely to have a Class 1 indication for statin treatment when compared with individuals without cancer. Important differences in statin use among cohorts based on sex, age, ethnicity, and socioeconomic status were identified, which may provide a framework through which CV risk factor control can be targeted in this population. KEY FINDINGS: Higher statin use in cancer patients: Among those with Class 1 recommendation to take statins, 60.8% of cancer patients were using them, compared with 47.8% of non-cancer individuals, indicating a greater adherence to heart health recommendations in the cancer group. Demographic variations in statin use: The study found notable differences in statin use among younger individuals, ethnic minorities, and those with lower income within the cancer patient group, suggesting disparities in how these subgroups manage their cardiovascular health.
This study reveals that individuals with cancer more likely to have a secondary prevention indication compared with individuals without cancer but not a primary prevention indication for statin and that they had higher rates of compliance with statin treatment, compared with those without cancer.
Assuntos
Doenças Cardiovasculares , Inibidores de Hidroximetilglutaril-CoA Redutases , Neoplasias , Inquéritos Nutricionais , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Neoplasias/epidemiologia , Feminino , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Idoso , Adulto , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Prevenção Primária , Prevenção Secundária/métodos , Padrões de Prática Médica , Medição de Risco , Fatores de Risco de Doenças Cardíacas , Fatores de Risco , Guias de Prática Clínica como Assunto , Prevalência , Fidelidade a Diretrizes , Comorbidade , Estudos Transversais , Dislipidemias/tratamento farmacológico , Dislipidemias/epidemiologia , Fatores de TempoRESUMO
BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.
Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de RiscoRESUMO
BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.
Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Remoção de Dispositivo , Catéteres , Valvas Cardíacas , Sistema de RegistrosRESUMO
Antiplatelet therapy (APT) is the foundation of treatment and prevention of atherothrombotic events in patients with atherosclerotic cardiovascular disease. Selecting the optimal APT strategies to reduce major adverse cardiovascular events, while balancing bleeding risk, requires ongoing review of clinical trials. Appended, the focused update of the Canadian Cardiovascular Society/Canadian Association of Interventional Cardiology guidelines for the use of APT provides recommendations on the following topics: (1) use of acetylsalicylic acid in primary prevention of atherosclerotic cardiovascular disease; (2) dual APT (DAPT) duration after percutaneous coronary intervention (PCI) in patients at high bleeding risk; (3) potent DAPT (P2Y12 inhibitor) choice in patients who present with an acute coronary syndrome (ACS) and possible DAPT de-escalation strategies after PCI; (4) choice and duration of DAPT in ACS patients who are medically treated without revascularization; (5) pretreatment with DAPT (P2Y12 inhibitor) before elective or nonelective coronary angiography; (6) perioperative and longer-term APT management in patients who require coronary artery bypass grafting surgery; and (7) use of APT in patients with atrial fibrillation who require oral anticoagulation after PCI or medically managed ACS. These recommendations are all on the basis of systematic reviews and meta-analyses conducted as part of the development of these guidelines, provided in the Supplementary Material.