Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Eye (Lond) ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39322767

RESUMO

OBJECTIVES: To analyse the accuracy of artificial intelligence (AI)-driven intraocular (IOL) calculation formulae, together with established formulae using the heteroscedastic methodology and the Eyetemis Analysis Tool. METHODS: Data from 404 eyes who underwent uneventful phacoemulsification with implantation of the SN60WF IOL were retrospectively reviewed. IOL power calculations were performed using the Barrett Universal II (BUII), EVO 2.0, Hoffer QST, K6, Ladas Super Formula (LSF), Nallasamy, PEARL-DGS and RBF 3.0 formulae. The SD of the prediction error (PE), served as the primary metric for accuracy. The mean absolute deviation (MAD) and the predictability rates within intervals from ±0.25 D to ±1.50 D were also evaluated. The Eyetemis Analysis Tool was used for further validation. RESULTS: The SD ranged from 0.468 (Nallasamy) to 0.510 (LSF). The Nallasamy formula had a significantly lower SD than the BUII (0.505, p = 0.025) and K6 (0.489, p = 0.022) formulae. The Nallasamy formula also exhibited the lowest MAD (0.358) with a significant difference compared with the Hoffer QST formula (0.384, p < 0.001). Finally, a significantly higher percentage of eyes achieving ± 0.50 D of the target refraction was seen using the Nallasamy formula (77.19%) compared with the Hoffer QST (71.04%, p = 0.019) and Ladas Super Formula (70.79%, p = 0.030) formulae. CONCLUSIONS: The Nallasamy formula, incorporating AI technology, demonstrated superior accuracy according to the analysis guidelines for PE statistics for non-gaussian datasets recommended by Holladay et al. and the online Eyetemis Analysis Tool.

2.
Eur J Ophthalmol ; : 11206721241272172, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39140330

RESUMO

PURPOSE: To describe the placement of a silicone shield to protect the optical cylinder following osteo-keratoprosthesis or osteo-odonto-keratoprosthesis (O/OKP) procedures in four patients. METHODS: In this retrospective observational study, we reviewed all patients who underwent O/OKP in our tertiary medical centre. We found four patients in whom a protective cellphone silicone shield (VisionGuard+, Zagg, Utah, USA) was cut with a 3 mm dermal punch and placed on the polymethyl methacrylate (PMMA) optical cylinder of an O/OKP 3-4 months after implantation to either correct or prevent abrasions. RESULTS: The first patient presented with a severely abraded OOKP optic that reduced BCVA from 6/6 to 6/20. The shield smoothed the optical surface and filled minor scratches, leading to BCVA improvement to 6/9. In the subsequent three patients, the optic was relatively clear, and the shield was used as a preventive measure. In two patients, the shield fell off after a few weeks and was replaced. CONCLUSIONS: Placing a protective silicone shield on the optical cylinder of an O/OKP can prevent permanent abrasions and, in an already scratched polymethyl methacrylate (PMMA) optic cylinder, improve vision by smoothing the surface. This intervention can be clinically significant, considering that the optical cylinder cannot be removed after implantation.

3.
Cornea ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39167613

RESUMO

PURPOSE: The purpose of this study was to identify early indicators of keratoconus progression in Pentacam data using machine learning (ML) techniques. METHODS: A retrospective Pentacam tabular data set was created by retrieving 11,760 tomography tests performed in patients with keratoconus. Data for eyes labeled unstable based on their referral for cross-linking were differentiated from data for eyes labeled stable and not referred for follow-up procedures. A boosted decision tree was trained on the final data set using a cross-validation method. RESULTS: The final labeled data set included 1218 tomography tests. Training a ML model on a single test for each eye did not accurately predict disease progression, as indicated by the mean receiver-operating characteristic area under the curve of 0.59 ± 0.1, with precision of 0.27, recall of 0.3, and F1 score of 0.28. Training on serial tests for each eye included 819 tomography scans and yielded good prognostic abilities: a receiver-operating characteristic area under the curve of 0.75 ± 0.07, precision of 0.32, recall of 0.67, and F1 score of 0.43. In addition, 4 of the 55 Pentacam raw data parameters predominantly used the algorithm decision: age, central keratoconus index, Rs B, and D10 mm pachy. CONCLUSIONS: This study revealed specific dominant parameters attributing to the classification of stability, which are not routinely assessed in determining progression in common practice. Using ML techniques, keratoconus deterioration was evaluated algorithmically with training on multiple tests, yet was not predicted by a single tomography test. Hence, our study highlights novel factors to the current consideration of cross-linking referral and may serve as a supportive tool for clinicians.

4.
Int Ophthalmol ; 44(1): 283, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922523

RESUMO

PURPOSE: To examine the rate of ciliary body detachment in patients with choroidal detachment following glaucoma surgery and its effect on the clinical course, management, and prognosis. METHODS: A prospective observational case-series study. Patients with choroidal detachment following glaucoma surgery in 2018-2019 were included. All underwent complete ophthalmological examination and ultrasound biomicroscopy for evaluation of the presence and extent of ciliary body detachment. Follow-up examinations including ultrasound biomicroscopy scans were performed at 1 week, 1 month, 3 months, and 6 months. RESULTS: Eight patients (8 eyes) were enrolled, 4 male and 4 female, of mean age 72 years (range 60-83). Five patients underwent trabeculectomy with mitomycin C (0.02%), which was combined with phacoemulsification cataract extraction in one; two underwent Ahmed glaucoma valve implantations, and one underwent ab-interno Xen45 gel stent implantation with mitomycin C (0.02%). The mean intraocular pressure was 26.0 ± 7.65 mmHg preoperatively, dropping to 6.9 ± 2.64 mmHg on first postoperative day one. Mean time from surgery to diagnosis of choroidal detachment was 11.6 ± 5.73 days. Ciliary body detachment was identified by ultrasound biomicroscopy in all patients, ranging between one and four quadrants. All patients were treated with topical steroids and cycloplegics; three (37.5%) received oral steroids. No surgical intervention for the choroidal or ciliary body detachments was indicated. CONCLUSIONS: In this real-world prospective study, concurrent ciliary body detachment was identified in all patients who presented with choroidal detachment following glaucoma surgery. This observation may deepen our understanding of the mechanism underlying the hypotony that is often seen after glaucoma surgery.


Assuntos
Efusões Coroides , Corpo Ciliar , Glaucoma , Pressão Intraocular , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Pressão Intraocular/fisiologia , Efusões Coroides/diagnóstico , Efusões Coroides/etiologia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/complicações , Complicações Pós-Operatórias/diagnóstico , Microscopia Acústica , Seguimentos , Trabeculectomia/efeitos adversos , Trabeculectomia/métodos , Implantes para Drenagem de Glaucoma/efeitos adversos , Acuidade Visual , Doenças da Úvea/diagnóstico , Doenças da Úvea/etiologia , Tomografia de Coerência Óptica/métodos
5.
Ophthalmic Epidemiol ; : 1-9, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38718101

RESUMO

PURPOSE: Prompted by the clinical concern that limited healthcare resources allocation affects physicians' research productivity, this study examines the association between bibliometric indices of ophthalmologic research and national economic indicators in Organisation for Economic Co-operation and Development (OECD) countries. METHODS: The Scimago Journal and Country rank source was searched for research productivity data in ophthalmology among OECD countries between 1996 and 2019. Bibliometric indices included: documents number, number and percent of citable documents, citations number, citations per document, and H-index. The updated economic indicators of each country (gross domestic product [GDP] per capita, health spending as percent of GDP (health expenditure), gross domestic expenditure on research, and development as percent of GDP [GERD]) were collected from the World Bank and the OECD websites. Correlation between economic and bibliometric metrics and multivariate linear regression analyses were performed. RESULTS: Among 267,444 documents analyzed, correlation analysis found a strong correlation between health expenditure and H index (r = 0.711, p < 0.001); a moderate correlation between health expenditure and documents number (r = 0.589, p < 0.001), number of citable document (r = 0.593, p < 0.001) and citations number (r = 0.673, p < 0.001); and a moderate correlation between GERD and H index (r = 0.564, p < 0.001). Multivariate regression analysis controlling for economic factors, population and language showed the independent association of these parameters with bibliometric indices. CONCLUSIONS: This study demonstrates a positive correlation between bibliometric indicators of ophthalmology research and economic factors, particularly health expenditure, among the OECD countries. Our results suggest an advantage of domestic investment in health to expand academic productivity in the field of ophthalmology.

6.
Harefuah ; 163(5): 310-314, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734945

RESUMO

INTRODUCTION: Corneal disease is among the leading reversible causes of blindness worldwide. Corneal transplantation is a successful and curative treatment for most of these cases. However, in certain indications it is not amendable for standard corneal transplantation, the only available option to restore functional vision is keratoprosthesis (KPro) implantation. KPros may also offer an alternative to the global shortage of donor corneas, limiting the access to transplantations. However, current KPros face many challenges, including surgical complexity that requires skilled surgeons and vast resources as well as unique surgical and post-operative complications. Although several artificial corneas have been proposed over the years, two implants are mostly used in the clinical setting today. The first, the Boston KPro, consists of a front plate with an optical stem and a back plate snapped together with donor corneal tissue in-between, which is then sutured to the patient's cornea. The second, the Osteo-odonto-keratoprosthesis (OOKP), uses biological tissue of the alveolar bone to support an optical cylinder within the eye. The indications, surgical techniques, and complication profile of the two procedures are different and will be discussed in this review. Extensive research continues to improve the accessibility and technological developments of KPros in the search for a potential breakthrough in the treatment of these difficult cases.


Assuntos
Córnea , Doenças da Córnea , Transplante de Córnea , Próteses e Implantes , Humanos , Doenças da Córnea/cirurgia , Transplante de Córnea/métodos , Córnea/cirurgia , Órgãos Artificiais , Cegueira/etiologia , Complicações Pós-Operatórias
8.
Int Ophthalmol ; 44(1): 17, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38321320

RESUMO

OBJECTIVE: To raise awareness of conditions that can tomographically mimic corneal ectasia and describe the actions required to avoid misdiagnosis. METHODS: We report a retrospective case series of seven patients presenting at two tertiary care centers in Israel with a presumed diagnosis of keratoconus or post-refractive ectasia. Upon further examination, the ectasia diagnosis was reconsidered and eventually ruled out. RESULTS: Included were ten eyes of seven patients. Cases included bilateral diffuse Salzmann's nodular degeneration, ophthalmoplegia with strabismus which precluded proper fixation during the acquisition of tomography images, two cases of incorrect Pentacam parameter settings, a patient with a history of hyperopic laser-assisted in situ keratomileusis (LASIK) treatment in one eye and myopic LASIK in the fellow eye, a case of old post-photorefractive keratectomy (PRK) stromal haze, and a patient with posterior polymorphous corneal dystrophy. CONCLUSIONS: Tomography patterns mimicking corneal ectasia can appear in patients without ectatic pathology. The comprehensive ophthalmologist should be aware of such cases as they may substantially alter the treatment course and prognosis of these patients.


Assuntos
Ceratocone , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Humanos , Estudos Retrospectivos , Dilatação Patológica/patologia , Dilatação Patológica/cirurgia , Córnea/patologia , Ceratectomia Fotorrefrativa/métodos , Ceratocone/diagnóstico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer , Topografia da Córnea/métodos
9.
Invest Ophthalmol Vis Sci ; 65(2): 39, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38411968

RESUMO

Purpose: To review all reported disease-causing mutations in BEST1, perform genotype-phenotype correlation, and estimate disease prevalence in the Israeli population. Methods: Medical records of patients diagnosed with Best disease and allied diseases from nine Israeli medical centers over the past 20 years were collected, as were clinical data including ocular findings, electrophysiology results, and retina imaging. Mutation detection involved mainly whole exome sequencing and candidate gene analysis. Demographic data were obtained from the Israeli Bureau of Statistics (January 2023). A bibliometric study was also conducted to gather mutation data from online sources. Results: A total of 134 patients were clinically diagnosed with Best disease and related conditions. The estimated prevalence of Best disease was calculated to be 1 in 127,000, with higher rates among Arab Muslims (1 in 76,000) than Jews (1 in 145,000). Genetic causes were identified in 76 individuals (57%), primarily showing autosomal-dominant inheritance due to BEST1 mutations (58 patients). Critical conserved domains were identified consisting of a high percentage of dominant missense mutations, primarily in transmembrane domains and the intracellular region (Ca2+ binding domain) of the BEST1 protein. Conclusions: This study represents the largest cohort of patients with Best disease reported in Israel and globally. The prevalence in Israel is akin to that in Denmark but is lower than that in the United States. Critical conserved domains within the BEST1 protein are pivotal for normal functioning, and even minor missense alterations in these areas lead to a dominant disease manifestation. Genetic testing is indispensable as the gold standard for Best disease diagnosis due to the variable clinical presentation of the disease.


Assuntos
Distrofia Macular Viteliforme , Humanos , Israel/epidemiologia , Prevalência , Mutação , Estudos de Associação Genética , Bestrofinas
10.
JAMA Ophthalmol ; 141(12): 1140-1144, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37917077

RESUMO

Importance: Acute infectious conjunctivitis is a common ocular condition with major public health consequences. Objective: To assess regional variations and microbial etiologies of acute infectious conjunctivitis to guide treatment. Design, Setting, and Participants: In this cross-sectional study, patients with presumed acute infectious conjunctivitis were enrolled in the study at 5 sites (Honolulu, Hawaii; Los Angeles, San Francisco, and San Diego, California; and Petah-Tikva, Israel) from March 2021 to March 2023. Patients with allergic or toxic conjunctivitis were excluded. Main Outcomes and Measures: Pathogens were identified by unbiased RNA deep sequencing. Results: In all, 52 patients (mean [range] age, 48 [7-80] years; 31 females [60%]) were enrolled at 5 sites (6 patients from Honolulu, 9 from San Diego, 11 from Los Angeles, 13 from San Francisco, and 13 from Petah-Tikva). RNA deep sequencing detected human adenovirus species D in one-quarter of patients (13 of 52). A wide range of pathogens, including human coronavirus 229E, SARS-CoV-2, and herpes simplex virus type 1, was also identified, as well as several bacteria and fungi. Moreover, 62% (32 of 52) of patients presented with purulent discharge, while only 8% (4 of 52) of patients had confirmed bacterial pathogens. Conclusion and Relevance: In this cross-sectional study, pathogens associated with acute infectious conjunctivitis varied between all 5 sites in the US and Israel. Purulent discharge was a common presenting sign in this study, with a low specificity for bacteria-associated conjunctivitis, suggesting that further diagnostic workup may be necessary to inform antibiotic stewardship. Additional research on cost-effectiveness of using RNA deep sequencing is needed to ascertain whether it is better to monitor patients clinically until resolution of disease.


Assuntos
Conjuntivite , Feminino , Humanos , Pessoa de Meia-Idade , Bactérias , Conjuntivite/microbiologia , Estudos Transversais , Doença Aguda , Vigilância em Saúde Pública
11.
J Pers Med ; 13(5)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37240988

RESUMO

The study aimed to examine the effect of cataract extraction on ophthalmologists' ability to detect pseudoexfoliation (PXF) syndrome. A total of 31 patients admitted for elective cataract surgery were enrolled in this prospective comparative study. Prior to surgery, patients underwent slit-lamp examination and gonioscopy conducted by experienced glaucoma specialists. Subsequently, patients were re-examined by a different glaucoma specialist and comprehensive ophthalmologists. Pre-operatively, 12 patients were diagnosed with PXF on the basis of a Sampaolesi line (100%), anterior capsular deposits (83%), and pupillary ruff deposits (50%). The remaining 19 patients acted as controls. All patients were re-examined 10-46 months post-operatively. Of the 12 patients with PXF, 10 (83%) were correctly diagnosed post-operatively by glaucoma specialists and 8 (66%) by comprehensive ophthalmologists. There was no statistically significant difference in PXF diagnosis. However, detection of anterior capsular deposits (p = 0.02), Sampaolesi lines (p = 0.04), and pupillary ruff deposits (p = 0.01) were significantly lower post-operatively. Diagnosis of PXF is challenging in pseudophakic patients as the anterior capsule is removed during cataract extraction. Therefore, PXF diagnosis in pseudophakic patients relies mainly on the presence of deposits at other anatomical sites, and careful attention to these signs is required. Glaucoma specialists may be more likely than comprehensive ophthalmologists to detect PXF in pseudophakic patients.

12.
Ophthalmic Res ; 66(1): 921-927, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37231882

RESUMO

INTRODUCTION: Preoperative measurements of apparent chord mu length above 0.6 mm have been associated with higher risks for photic phenomena after cataract surgery with multifocal intraocular lenses (MFIOLs). METHODS: This retrospective study evaluated patients scheduled for elective cataract surgery at a single tertiary medical center between 2021 and 2022. Pupil diameter and apparent chord mu length were analyzed for eyes with biometry measurements from IOLMaster 700 (Carl Zeiss Meditec, AG) under photopic light conditions, before and after pharmacological pupil dilatation. Exclusion criteria were visual acuity worse than 20/100, prior intraocular surgery, refractive surgery, iris-related procedures, or pupil abnormalities affecting dilatation. Apparent chord mu lengths before and after pupil dilatation were compared. In addition, multivariate linear regression analysis, using a stepwise method, was conducted to assess possible predictors of apparent chord values. RESULTS: Included were 87 eyes of 87 patients. Mean chord mu length increased after pupillary dilatation from 0.32 ± 0.17 mm to 0.41 ± 0.17 mm for right eyes (p < 0.001) and from 0.29 ± 0.16 mm to 0.40 ± 0.22 mm for left eyes (p < 0.001). Seven eyes (8.0%) had an apparent chord mu of 0.6 mm and above pre-dilatation. Fourteen eyes (16.1%) with an apparent chord mu under 0.6 mm pre-dilatation had apparent chord mu of 0.6 mm or above post-dilatation. CONCLUSION: Apparent chord mu length significantly increases after pharmacological pupillary dilatation. Pupil size and dilatation status should always be considered during patient selection for a planned MFIOL using apparent chord mu length as a reference marker.


Assuntos
Catarata , Lentes Intraoculares , Midríase , Humanos , Pupila , Dilatação , Estudos Retrospectivos
13.
Eye (Lond) ; 37(7): 1484-1488, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35835990

RESUMO

PURPOSE: To assess the number of recruits for military service in the Israeli Defense Force (IDF) who underwent refractive surgery prior to enlistment and examine whether the procedure affected their ability to accomplish combat training. SETTING: Medical records of IDF recruits. DESIGN: Retrospective analysis of medical records of recruits with ametropia who underwent or did not undergo refractive surgery prior to enlistment. METHODS: Recruits were categorized into ametropes and recruits who underwent refractive surgery. Fitness and assignment to combat units and completion status of combat training were compared between the two groups. RESULTS: The study included 334,688 (182,969 males, 151,719 females) ametropes of which 5231 (4753 males, 478 females) underwent refractive surgery prior to recruitment. Refractive surgery prevalence increased from 9/1000 ametropes in 2005 to 18.5/1000 ametropes in 2018 (r = 0.912, p < 0.001); 2643 of the operated recruits (50.5%) had their surgery at the age of 17-18. Dropout rates from combat training were significantly lower in the refractive surgery group during the study period (1.68% vs. 6.14%, respectively, p < 0.001). Soldiers in the operated group were more frequently referred to ophthalmologists than those in the ametropes group and less frequently referred to optometrists. CONCLUSIONS: The prevalence of refractive surgery in IDF recruits has increased substantially during the last decade with more of them applying to combat units. Refractive surgery opened new possibilities for recruits who were unfit for combat duty prior to surgery and did not appear to impair the chances of successfully completing combat training.


Assuntos
Militares , Erros de Refração , Procedimentos Cirúrgicos Refrativos , Masculino , Feminino , Humanos , Prevalência , Israel/epidemiologia , Estudos Retrospectivos , Erros de Refração/epidemiologia
14.
Eye (Lond) ; 37(8): 1566-1570, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35869390

RESUMO

OBJECTIVE: To evaluate the sensitivity and specificity of the ABCD progression display for keratoconus progression. METHODS: Data was collected from patients that underwent at least two Pentacam assessments 6 months apart. Sensitivity and specificity were calculated for the ABCD progression display. Progression was defined by criterion 1: change in two ABCD parameters above 80% confidence interval (CI) or criterion 2: change in one ABCD parameter above 95%CI. Receiver operating characteristic analysis compared the area under the curve (AUC) of all ABCD parameter combinations. RESULTS: Thirty eyes were evaluated over a median time of 10.3 months. Progression by criterion 1 resulted in a sensitivity of 61.9% and specificity of 88.9%. Progression by criterion 2 resulted in higher sensitivity (80.9%) and specificity (100%). Pairwise comparisons of the ROC curves show that the AUC achieved by criterion 2 was significantly higher than criterion 1 (0.905 vs. 0.754, p = 0.0332). Evaluation of all ABCD combinations with a significant change of 80% or 95% CI did not show superiority over criterion 1 or 2 regarding progression detection. The D parameter had a very low AUC (0.5-0.556). CONCLUSIONS: The ABCD progression display can assess keratoconus progression with high sensitivity and specificity, thus assisting the patients' decision-making process. The D parameter did not contribute to the sensitivity or specificity of this classification.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Córnea , Topografia da Córnea/métodos , Sensibilidade e Especificidade , Curva ROC , Estudos Retrospectivos
15.
Eye (Lond) ; 37(7): 1331-1335, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35650323

RESUMO

OBJECTIVES: To describe the first clinical implantation of the CorNeat™ keratoprosthesis, which utilizes a polymeric scaffold for biointegration within ocular tissue. METHODS: The CorNeat keratoprosthesis was implanted in the right eye of a patient with bilateral corneal opacification and neovascularization secondary to multiple failed grafts. The following surgical technique was used: 360 degree peritomy; epithelial scraping and corneal marking; pre-placement of three corneo-scleral sutures through the implant; central trephination using a 7 mm trephine and host cornea removal; keratoprosthesis placement and sutures tightening while fitting the corneal edge into the posterior groove of the CorNeat keratoprosthesis; and repositioning of the conjunctiva over the implant skirt and fixation with sutures and Fibrin sealant. RESULTS: Twelve months postoperatively visual acuity improved to 1/16 from hand movement. The keratoprosthesis was properly positioned. Tactile intraocular pressure was assessed as normal. Regional, mostly nasal, conjunctival retraction of 4-5 mm over the nano-fibre skirt was seen throughout follow-up. The anterior chamber was quiet and well-formed. No other postoperative complications were observed. CONCLUSION: This initial case may imply a potential breakthrough in the treatment of corneal disease not amenable to standard corneal transplant. Long follow-up and additional implantations are desired to prove the long-term safety and efficacy of this device.


Assuntos
Doenças da Córnea , Transplante de Córnea , Humanos , Córnea/cirurgia , Próteses e Implantes , Doenças da Córnea/cirurgia , Implantação de Prótese , Complicações Pós-Operatórias/cirurgia
16.
J Refract Surg ; 38(9): 565-571, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36098394

RESUMO

PURPOSE: To compare the accuracy of the Barrett Integrated K (IK) toric calculator with the standard Barrett toric calculator. METHODS: Consecutive patients who underwent cataract extraction with implantation of a toric intraocular lens at the Rabin Medical Center, Israel, were reviewed. Errors in predicted postoperative refractive astigmatism were calculated for the Barrett toric calculator using biometry measurements only and with the IK tool using biometry and tomography. Both methods were assessed with predicted and measured posterior corneal astigmatism (PPCA and MPCA, respectively). RESULTS: The study included 73 eyes of 59 patients. The mean centroid prediction error using PPCA (0.08 ± 0.80 D @ 78°) was significantly different compared with MPCA (0.07 ± 0.80 D @ 48°, P = .016). In addition, a significant difference between IK-PPCA (0.06 ± 0.80 D @ 80°) and IK-MPCA (0.05 ± 0.80 D @ 38°) was found (P = .023). The median absolute prediction error ranged from 0.55 D using IK-PPCA to 0.60 D using PPCA, with no significant differences between the four calculation versions. No significant differences were found between the calculators in the predictability rates within ±0.50, ±0.75, and ±1.00 D. Analysis of one eye of each patient showed similar results. CONCLUSIONS: The IK calculator yielded comparable outcomes to the standard Barrett calculator. Although differences in the mean centroid errors were found, they were clinically insignificant and predominantly seen in the axis of the predicted astigmatism error. These minor differences were mainly attributed to the incorporation of the MPCA in the calculation. [J Refract Surg. 2022;38(9):565-571.].


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Córnea , Humanos , Implante de Lente Intraocular/métodos , Acuidade Visual
17.
Transl Vis Sci Technol ; 11(9): 16, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36129699

RESUMO

Purpose: To compare the effect of three commonly prescribed anti-inflammatory eye drops on corneal epithelial cells in vitro. Methods: Three different lines of human corneal epithelial cells were tested: primary cells cultured from donor tissue, commercially available primary cells, and immortalized cells. Cells were seeded on 96-well plates and treated with the following eye drops: cyclosporine 0.05%, lifitegrast 5%, and tacrolimus 0.03% or 0.1%. Exposure times tested were 30 seconds, 1 minute, 2 minutes, 1 hour, 2 hours, 4 hours, and 24 hours. Brightfield images and viability assays were analyzed 48 to 72 hours after the initiation of treatments. At least five replicates were tested per drug and time exposure. Results: Commercially obtained primary cells showed reduced viability following 1 hour with tacrolimus 0.1% (8%; P = 0.043%) and 4 hours with tacrolimus 0.03% (17%; P = 0.042%). Lifitegrast exposure reduced primary cell viability after 4 hours (10%; P = 0.042). Cell viability in primary cells was not deleteriously affected following exposure to cyclosporine for up to 4 hours. A similar trend was observed in both primary cells cultured from donor tissue and immortalized human corneal epithelial cells, demonstrating greater decreases in cell viability in tacrolimus compared to lifitegrast and cyclosporine. Light microscopy imaging for analysis of cell morphology and confluence supported the results. Conclusions: Tacrolimus showed the highest impact on corneal epithelium survival in vitro, and cyclosporine proved the most protective. Translational Relevance: Comparing anti-inflammatory eye drops on corneal epithelial cells in vitro may inform eye drop selection and development for clinical purposes.


Assuntos
Células Epiteliais , Tacrolimo , Anti-Inflamatórios/farmacologia , Ciclosporina/farmacologia , Humanos , Soluções Oftálmicas/farmacologia , Fenilalanina/análogos & derivados , Sulfonas , Tacrolimo/farmacologia
18.
Int Ophthalmol ; 42(9): 2665-2671, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35381894

RESUMO

PURPOSE: To validate the effectiveness of the multi-metric D-index by Pentacam in detecting keratoconus (KC) progression. MATERIALS AND METHODS: This was a retrospective study of KC patients at the Rabin Medical Center, Petah Tikva, Israel, during 2016-2018 with at least two corneal tomography examinations six months apart. Agreement between clinical diagnosis of progression (1.5D increase in mean keratometric value, 1D increase in Kmax, a 5% decrease in central corneal thickness (CCT), worsening of visual acuity by more than one line, or deterioration of manifest corneal astigmatism > 1.5D) and the D-index was evaluated. Receiver operating characteristic (ROC) analysis was used to find the D-index's optimal cutoff value to show progression. RESULTS: We included KC eyes in the stable group (N = 7) and the progression group (N = 54). Patient demographics and tomographic parameters at baseline were similar between the groups. The D-index change was significantly higher in the progression group than in the stable group (median + 1 and 0.0, respectively, p = 0.024). Based on the ROC analysis, the optimal D-index cutoff change within at least six months was 0.32 (59.3% sensitivity and 100% specificity (area under the curve [AUC] = 0.771, Youden = 0.592). Subjects with a D-index change above this value had a 21.1-fold increase in odds for corneal ectasia progression requiring CXL (OR: 21.1, 95%CI 1.17-398.8, p = 0.038). CONCLUSION: The multi-metric D-index can serve as a clinically feasible parameter to detect KC progression and guide patients' referral for further interventions.


Assuntos
Ceratocone , Córnea , Topografia da Córnea , Humanos , Estudos Retrospectivos , Acuidade Visual
20.
Eur J Ophthalmol ; 32(3): 1448-1456, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34269097

RESUMO

PURPOSE: To examine the clinical outcomes, efficacy, safety, and predictability of transepithelial photorefractive keratectomy (Trans-PRK) operations performed on the day of the first screening visit in comparison with operations scheduled at a following appointment. METHODS: Data of consecutive patients with myopia of various degrees, who underwent Trans-PRK, were retrospectively analyzed. Findings were compared between patients who underwent Trans-PRK on the same day of first consultation to patients that underwent surgery at subsequent visits, following initial consultation on a different day. RESULTS: The study included 599 eyes treated on the initial visit day and 1936 eyes treated on a subsequent visit. Mean final spherical equivalent was close to emmetropia in both groups (p = 0.183). Efficacy indices were 0.928 ± 0.192 in the initial-visit group and 0.945 ± 0.163 in the second-visit group (p = 0.152). Safety indices were 0.954 ± 0.156 and 0.955 ± 0.151 (p = 0.707), respectively. No differences between the groups were seen in uncorrected visual acuity (UDVA) of ⩾20/20, ⩾20/25, and ⩾20/32. Only the sub-analysis of patients reaching UDVA of 20/40 or better was slightly lower in the first-visit (95.5%) compared with the second-visit group (97.9%, p = 0.001). Results of attempted correction within ±0.50 D were: 63.3% and 69.0%, respectively (p = 0.009). Complications profiles in the two groups were comparable. CONCLUSIONS: Trans-PRK completed on the day of the first screening appointment demonstrated a similar safety outcome compared with subsequent-visits procedures, and slightly lower, yet comparable, results regarding efficacy and predictability.


Assuntos
Miopia , Ceratectomia Fotorrefrativa , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Encaminhamento e Consulta , Refração Ocular , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA