RESUMO

From the onset of coronavirus disease (COVID-19) pandemic, there are concerns regarding the disease spread and environmental pollution of biohazard since studies on genetic engineering flourish and numerous genetic materials were used such as the nucleic acid test of the severe acute respiratory syndrome coronavirus (SARS-CoV-2). In this work, we studied genetic material pollution in an institute during a development cycle of plasmid, one of typical genetic materials, with typical laboratory settings. The pollution source, transmission routes, and pollution levels in laboratory environment were examined. The Real-Time quantitative- Polymerase Chain Reaction results of all environmental mediums (surface, aerosol, and liquid) showed that a targeted DNA segment occurred along with routine experimental operations. Among the 79 surface and air samples collected in the genetic material operation, half of the environment samples (38 of 79) are positive for nucleic acid pollution. Persistent nucleic acid contaminations were observed in all tested laboratories and spread in the public area (hallway). The highest concentration for liquid and surface samples were 1.92 × 108 copies/uL and 5.22 × 107 copies/cm2, respectively. Significant amounts of the targeted gene (with a mean value of 74 copies/L) were detected in the indoor air of laboratories utilizing centrifuge devices, shaking tables, and cell homogenizers. Spills and improper disposal of plasmid products were primary sources of pollution. The importance of establishing designated experimental zones, employing advanced biosafety cabinets, and implementing highly efficient cleaning systems in laboratories with lower biosafety levels is underscored. SYNOPSIS: STATEMENT. Persistent environmental pollutions of genetic materials are introduced by typical experiments in laboratories with low biosafety level.


Assuntos
Laboratórios , Humanos , SARS-CoV-2/genética , Plasmídeos/genética , COVID-19/transmissão , Poluição Ambiental/análise , Monitoramento Ambiental
2.
Bioelectrochemistry ; 157: 108651, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38281367

RESUMO

Due to the wide range of electrochemical devices available, DNA nanostructures and material-based technologies have been greatly broadened. They have been actively used to create a variety of beautiful nanostructures owing to their unmatched programmability. Currently, a variety of electrochemical devices have been used for rapid sensing of biomolecules and other diagnostic applications. Here, we provide a brief overview of recent advances in DNA-based biomolecular assays. Biosensing platform such as electrochemical biosensor, nanopore biosensor, and field-effect transistor biosensors (FET), which are equipped with aptamer, DNA walker, DNAzyme, DNA origami, and nanomaterials, has been developed for amplification detection. Under the optimal conditions, the proposed biosensor has good amplification detection performance. Further, we discussed the challenges of detection strategies in clinical applications and offered the prospect of this field.


Assuntos
Técnicas Biossensoriais , DNA Catalítico , Nanoporos , Nanoestruturas , Técnicas Eletroquímicas/métodos , DNA/química , Nanoestruturas/química , DNA Catalítico/química , Técnicas Biossensoriais/métodos
3.
ACS Sens ; 8(7): 2681-2690, 2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37347966

RESUMO

Electrical properties of single cells are important label-free biomarkers of disease and immunity. At present, impedance flow cytometry (IFC) provides important means for high throughput characterization of single-cell electrical properties. However, the accuracy of the spherical single-shell electrical model widely used in IFC has not been well evaluated due to the lack of reliable and reproducible single-shell model particles with true-value electrical parameters as benchmarks. Herein, a method is proposed to evaluate the accuracy of the single-cell electrical model with cell-sized unilamellar liposomes synthesized through double emulsion droplet microfluidics. The influence of three key dimension parameters (i.e., the measurement channel width w, height h, and electrode gap g) in the single-cell electrical model were evaluated through experiment. It was found that the relative error of the electrical intrinsic parameters measured by IFC is less than 10% when the size of the sensing zone is close to the measured particles. It further reveals that h has the greatest influence on the measurement accuracy, and the maximum relative error can reach ∼30%. Error caused by g is slightly larger than w. This provides a solid guideline for the design of IFC measurement system. It is envisioned that this method can advance further improvement of IFC and accurate electrical characterization of single cells.


Assuntos
Lipossomos , Microfluídica , Citometria de Fluxo/métodos , Impedância Elétrica , Eletrodos
4.
Plant Cell ; 35(6): 2062-2078, 2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-36881857

RESUMO

Inflorescence branch number is a yield-related trait controlled by cell fate determination in meristems. Two MADS-box transcription factors (TFs)-SISTER OF TM3 (STM3) and JOINTLESS 2 (J2)-have opposing regulatory roles in inflorescence branching. However, the mechanisms underlying their regulatory functions in inflorescence determinacy remain unclear. Here, we characterized the functions of these TFs in tomato (Solanum lycopersicum) floral meristem and inflorescence meristem (IM) through chromatin immunoprecipitation and sequencing analysis of their genome-wide occupancy. STM3 and J2 activate or repress the transcription of a set of common putative target genes, respectively, through recognition and binding to CArG box motifs. FRUITFULL1 (FUL1) is a shared putative target of STM3 and J2 and these TFs antagonistically regulate FUL1 in inflorescence branching. Moreover, STM3 physically interacts with J2 to mediate its cytosolic redistribution and restricts J2 repressor activity by reducing its binding to target genes. Conversely, J2 limits STM3 regulation of target genes by transcriptional repression of the STM3 promoter and reducing STM3-binding activity. Our study thus reveals an antagonistic regulatory relationship in which STM3 and J2 control tomato IM determinacy and branch number.


Assuntos
Solanum lycopersicum , Solanum lycopersicum/genética , Inflorescência/genética , Diferenciação Celular , Imunoprecipitação da Cromatina , Citosol , Meristema/genética , Regulação da Expressão Gênica de Plantas/genética
5.
Plant Physiol ; 192(1): 293-306, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36747310

RESUMO

Inflorescence architecture directly impacts yield potential in most crops. As a model of sympodial plants, tomato (Solanum lycopersicum) inflorescence exhibits highly structural plasticity. However, the genetic regulatory network of inflorescence architecture in tomato remains unclear. Here, we investigated a modulator of inflorescence branching in tomato, TARGET OF EAT1 (SlTOE1), an APETALA2 (AP2) family member found to be predominantly expressed in the floral meristem (FM) of tomato. sltoe1 knockout mutants displayed highly branched inflorescences and defective floral organs. Transcriptome analysis revealed that SISTER OF TM3 (STM3) and certain floral development-related genes were upregulated in the flower meristem of sltoe1. SlTOE1 could directly bind the promoters of STM3 and Tomato MADS-box gene 3 (TM3) to repress their transcription. Simultaneous mutation of STM3 and TM3 partially restored the inflorescence branching of the sltoe1cr mutants, suggesting that SlTOE1 regulates inflorescence development, at least in part through an SlTOE1STM3/TM3 module. Genetic analysis showed that SlTOE1 and ENHANCER OF JOINTLESS 2 (EJ2) additively regulate tomato inflorescence branching; their double mutants showed more extensive inflorescence branching. Our findings uncover a pathway controlling tomato inflorescence branching and offer deeper insight into the functions of AP2 subfamily members.


Assuntos
Inflorescência , Solanum lycopersicum , Solanum lycopersicum/genética , Redes Reguladoras de Genes , Flores , Meristema/metabolismo , Mutação/genética , Regulação da Expressão Gênica de Plantas , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo
6.
Biosens Bioelectron ; 219: 114816, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36327559

RESUMO

Airborne transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has highlighted the urgent need for aerosol monitoring of SARS-CoV-2 to prevent sporadic outbreaks of COVID-19. The inadequate sensitivity of conventional methods and the lack of an on-site detection system limited the practical SARS-CoV-2 monitoring of aerosols in public spaces. We have developed a novel SARS-CoV-2-in-aerosol monitoring system (SIAMs) which consists of multiple portable cyclone samplers for collecting aerosols from several venues and a sensitive "sample-to-answer" microsystem employing an integrated cartridge for the analysis of SARS-CoV-2 in aerosols (iCASA) near the sampling site. By seamlessly combining viral RNA extraction based on a chitosan-modified quartz filter and "in situ" tetra-primer recombinase polymerase amplification (tpRPA) into an integrated microfluidic cartridge, iCASA can provide an ultra-high sensitivity of 20 copies/mL, which is nearly one order of magnitude greater than that of the commercial kit, and a short turnaround time of 25 min. By testing various clinical samples of nasopharyngeal swabs, saliva, and exhaled breath condensates obtained from 23 COVID-19 patients, we demonstrate that the positive rate of our system was 3.3 times higher than those of the conventional method. Combining with multiple portable cyclone samplers, we detected 52.2% (12/23) of the aerosol samples, six times higher than that of the commercial kit, collected from the isolation wards of COVID-19 patients, demonstrating the excellent performance of our system for SARS-CoV-2-in-aerosol monitoring. We envision the broad application of our microsystem in aerosol monitoring for fighting the COVID-19 pandemic.

7.
Nat Commun ; 13(1): 617, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35105875

RESUMO

As cancer is increasingly considered a metabolic disorder, it is postulated that serum metabolite profiling can be a viable approach for detecting the presence of cancer. By multiplexing mass spectrometry fingerprints from two independent nanostructured matrixes through machine learning for highly sensitive detection and high throughput analysis, we report a laser desorption/ionization (LDI) mass spectrometry-based liquid biopsy for pan-cancer screening and classification. The Multiplexed Nanomaterial-Assisted LDI for Cancer Identification (MNALCI) is applied in 1,183 individuals that include 233 healthy controls and 950 patients with liver, lung, pancreatic, colorectal, gastric, thyroid cancers from two independent cohorts. MNALCI demonstrates 93% sensitivity at 91% specificity for distinguishing cancers from healthy controls in the internal validation cohort, and 84% sensitivity at 84% specificity in the external validation cohort, with up to eight metabolite biomarkers identified. In addition, across those six different cancers, the overall accuracy for identifying the tumor tissue of origin is 92% in the internal validation cohort and 85% in the external validation cohort. The excellent accuracy and minimum sample consumption make the high throughput assay a promising solution for non-invasive cancer diagnosis.


Assuntos
Detecção Precoce de Câncer/métodos , Lasers , Nanoestruturas/química , Neoplasias/classificação , Neoplasias/diagnóstico , Antígenos de Neoplasias/sangue , Biomarcadores Tumorais/sangue , China , Estudos de Coortes , Feminino , Humanos , Aprendizado de Máquina , Masculino , Sensibilidade e Especificidade
8.
Chem Sci ; 12(47): 15750-15756, 2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-35003607

RESUMO

The lack of an efficient, low-cost sequencing method has long been a significant bottleneck in protein research and applications. In recent years, the nanopore platform has emerged as a fast and inexpensive method for single-molecule nucleic acid sequencing, but attempts to apply it to protein/peptide sequencing have resulted in limited success. Here we report a strategy to control peptide translocation through the MspA nanopore, which could serve as the first step toward strand peptide sequencing. By conjugating the target peptide to a helicase-regulated handle-ssDNA, we achieved a read length of up to 17 amino acids (aa) and demonstrated the feasibility of distinguishing between amino acid residues of different charges or between different phosphorylation sites. Further improvement of resolution may require engineering MspA-M2 to reduce its constriction zone's size and stretch the target peptide inside the nanopore to minimize random thermal motion. We believe that our method in this study can significantly accelerate the development and commercialization of nanopore-based peptide sequencing technologies.

9.
Anal Chim Acta ; 1058: 89-96, 2019 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-30851857

RESUMO

Paper based biosensor devices have the benefit of easy-use, low-cost and environmental friendly for point-of-care diagnostic application. In this research, we report a novel form of paper based biosensor with hierarchical assembled nanomaterials and MOF enhanced bio-probes for the simultaneous detection of microRNA-141 (miR-141) and microRNA-21 (miR-21) which have the potential for early cancer detection. The combination of multi-dimensional nanomaterial allows low impedance and high sensing area on typical poorly defined paper substrate. MOF conjugated bio-probe, methylene blue (MB) and ferrocene (Fc) with distinguishable electrochemical signal, further contributed to the high selectivity and sensitivity. Simultaneously detection of miR-141 and miR-21 with a detection limit of 0.1 fM was demonstrated under optimal conditions. All these features enable accurately target detection in serum samples. Therefore, this strategy is of promising as an inexpensive, easy access diagnosis platform for cancers by means of simultaneously detection of a variety of miRNA biomarkers.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , MicroRNAs/sangue , Papel , Técnicas Biossensoriais/instrumentação , DNA/genética , Sondas de DNA/genética , Dissulfetos/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Quadruplex G , Hemina/química , Humanos , Peróxido de Hidrogênio/química , Limite de Detecção , Nanopartículas Metálicas/química , Estruturas Metalorgânicas/química , Metais Pesados/química , MicroRNAs/genética , Molibdênio/química , Nanofios/química , Hibridização de Ácido Nucleico , Temperatura
10.
Talanta ; 194: 273-281, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30609531

RESUMO

In this study, an electrochemical biosensor was developed for highly sensitive and specific detection of target miRNA-155. The structure was formed by the hybridization of a tetrahedral DNA nanostructure-based biomolecular probe assembled on 3D nitrogen-doped reduced graphene oxide/ gold nanoparticles (3D N-doped rGO/AuNPs) electrode surface. Upon addition of target miRNA-155, the gold and silver nanorod/ thionine/ complementary DNA (AuAgNR/Thi/F) was hybridized with the target, and used for signal amplification, catalyzing the reduction of Thi as an electron mediator. Due to the signal amplification by the enhanced immobilization of DNA on the surface of 3D N-doped rGO/AuNPs electrode and AuAgNR/Thi, coupling the low background signal produced by blank solution, electrochemical performance of the device was optimized to be proportional to miRNA-155 concentration in the range of 1 × 10-11 to 1 × 10-4 M with a detection limit of 1 × 10-12 M. In addition, direct detection in serum is demonstrated with high specificity. Thus, this biosensor is potentially applicable for microRNA detection in medical research and early clinical diagnosis.


Assuntos
Técnicas Biossensoriais/métodos , Sondas de DNA/química , Grafite/química , Nanoestruturas/química , Nitrogênio/química , Óxidos/química , Sequência de Bases , Sondas de DNA/genética , Eletroquímica , Ouro/química , Humanos , Concentração de Íons de Hidrogênio , MicroRNAs/sangue , Temperatura
11.
Anal Chem ; 90(5): 3621-3627, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29446622

RESUMO

A reasonable and efficient strategy for the construction of hyper-cross-linked porous MoS2-CD-polymer frameworks (MoS2CDPFs) was demonstrated. Here, MoS2 nanosheets (NSs) can be decorated with amino functionalized ß-cyclodextrin, producing a nanoscale structural motif (MoS2@CD) for the synthesis of MoS2CDPFs. We demonstrated that CD polymer (CDP) as linker can be uniformly incorporated into the frameworks. Except for the pores created between MoS2 NSs, polymer doping generates extra interspace between MoS2 NSs and CD monomer. Interestingly, the resultant MoS2CDPFs can rapidly sequester aromatic phenolic micropollutant bisphenol A (0.1 mM) from water with 93.2% adsorption capacity, which is higher than that of MoS2, MoS2@CD, and CDP. The intercalation between MoS2 sheets with CDP imparts the frameworks durability in adsorption/desorption of aromatic phenolic micropollutants. Remarkably, the removal efficiency reduced only 3% after 10 regeneration-reuse cycles. These findings demonstrated that the porous MoS2-CD-polymer-based frameworks are promising adsorbents for rapid, flow-through water remediation.

12.
ACS Nano ; 8(12): 11994-2003, 2014 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-25380505

RESUMO

Previous measurements of the electronic conductance of DNA nucleotides or amino acids have used tunnel junctions in which the gap is mechanically adjusted, such as scanning tunneling microscopes or mechanically controllable break junctions. Fixed-junction devices have, at best, detected the passage of whole DNA molecules without yielding chemical information. Here, we report on a layered tunnel junction in which the tunnel gap is defined by a dielectric layer, deposited by atomic layer deposition. Reactive ion etching is used to drill a hole through the layers so that the tunnel junction can be exposed to molecules in solution. When the metal electrodes are functionalized with recognition molecules that capture DNA nucleotides via hydrogen bonds, the identities of the individual nucleotides are revealed by characteristic features of the fluctuating tunnel current associated with single-molecule binding events.


Assuntos
DNA , Microscopia de Tunelamento/instrumentação , Nucleotídeos , DNA/química , Condutividade Elétrica , Eletrodos , Ligação de Hidrogênio , Técnicas Analíticas Microfluídicas , Nucleotídeos/química , Paládio/química , Silício/química
13.
Nanoscale ; 6(15): 8900-6, 2014 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-24964839

RESUMO

We introduce a method to fabricate solid-state nanopores with sub-20 nm diameter in membranes with embedded metal electrodes across a 200 mm wafer using CMOS compatible semiconductor processes. Multi-layer (metal-dielectric) structures embedded in membranes were demonstrated to have high uniformity (± 0.5 nm) across the wafer. Arrays of nanopores were fabricated with an average size of 18 ± 2 nm in diameter using a Reactive Ion Etching (RIE) method in lieu of TEM drilling. Shorts between the membrane-embedded metals were occasionally created after pore formation, but the RIE based pores had a much better yield (99%) of unshorted electrodes compared to TEM drilled pores (<10%). A double-stranded DNA of length 1 kbp was translocated through the multi-layer structure RIE-based nanopore demonstrating that the pores were open. The ionic current through the pore can be modulated with a gain of 3 using embedded electrodes functioning as a gate in 0.1 mM KCl aqueous solution. This fabrication approach can potentially pave the way to manufacturable nanopore arrays with the ability to electrically control the movement of single or double-stranded DNA inside the pore with embedded electrodes.


Assuntos
Nanopartículas Metálicas/química , Metais/química , Nanoporos , DNA/química , Eletroquímica , Eletrodos , Íons , Teste de Materiais , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Nanotecnologia , Oxigênio/química , Cloreto de Potássio/química
14.
Proc Natl Acad Sci U S A ; 109(29): 11588-92, 2012 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-22753503

RESUMO

Graphene has attracted enormous attention for radio-frequency transistor applications because of its exceptional high carrier mobility, high carrier saturation velocity, and large critical current density. Herein we report a new approach for the scalable fabrication of high-performance graphene transistors with transferred gate stacks. Specifically, arrays of gate stacks are first patterned on a sacrificial substrate, and then transferred onto arbitrary substrates with graphene on top. A self-aligned process, enabled by the unique structure of the transferred gate stacks, is then used to position precisely the source and drain electrodes with minimized access resistance or parasitic capacitance. This process has therefore enabled scalable fabrication of self-aligned graphene transistors with unprecedented performance including a record-high cutoff frequency up to 427 GHz. Our study defines a unique pathway to large-scale fabrication of high-performance graphene transistors, and holds significant potential for future application of graphene-based devices in ultra-high-frequency circuits.


Assuntos
Grafite/química , Rádio , Transistores Eletrônicos , Micro-Ondas
16.
Nano Lett ; 12(6): 2653-7, 2012 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-21648419

RESUMO

Graphene transistors are of considerable interest for radio frequency (rf) applications. High-frequency graphene transistors with the intrinsic cutoff frequency up to 300 GHz have been demonstrated. However, the graphene transistors reported to date only exhibit a limited extrinsic cutoff frequency up to about 10 GHz, and functional graphene circuits demonstrated so far can merely operate in the tens of megahertz regime, far from the potential the graphene transistors could offer. Here we report a scalable approach to fabricate self-aligned graphene transistors with the extrinsic cutoff frequency exceeding 50 GHz and graphene circuits that can operate in the 1-10 GHz regime. The devices are fabricated on a glass substrate through a self-aligned process by using chemical vapor deposition (CVD) grown graphene and a dielectrophoretic assembled nanowire gate array. The self-aligned process allows the achievement of unprecedented performance in CVD graphene transistors with a highest transconductance of 0.36 mS/µm. The use of an insulating substrate minimizes the parasitic capacitance and has therefore enabled graphene transistors with a record-high extrinsic cutoff frequency (> 50 GHz) achieved to date. The excellent extrinsic cutoff frequency readily allows configuring the graphene transistors into frequency doubling or mixing circuits functioning in the 1-10 GHz regime, a significant advancement over previous reports (∼20 MHz). The studies open a pathway to scalable fabrication of high-speed graphene transistors and functional circuits and represent a significant step forward to graphene based radio frequency devices.


Assuntos
Grafite/química , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Conformação Molecular
17.
J Mater Chem ; 22(4): 1498-1503, 2012 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-25414547

RESUMO

Graphene has attracted considerable interest as a potential material for future electronics. Although mechanical peel is known to produce high quality graphene flakes, practical applications require continuous graphene layers over a large area. The catalyst-assisted chemical vapor deposition (CVD) is a promising synthetic method to deliver wafer-sized graphene. Here we present a systematic study on the nucleation and growth of crystallized graphene domains in an atmospheric pressure chemical vapor deposition (APCVD) process. Parametric studies show that the mean size of the graphene domains increases with increasing growth temperature and CH4 partial pressure, while the density of domains decreases with increasing growth temperature and is independent of the CH4 partial pressure. Our studies show that nucleation of graphene domains on copper substrate is highly dependent on the initial annealing temperature. A two-step synthetic process with higher initial annealing temperature but lower growth temperature is developed to reduce domain density and achieve high quality full-surface coverage of monolayer graphene films. Electrical transport measurements demonstrate that the resulting graphene exhibits a high carrier mobility of up to 3000 cm2 V-1 s-1 at room temperature.

18.
Nat Commun ; 2: 579, 2011 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-22146398

RESUMO

Graphene has the potential for high-speed, wide-band photodetection, but only with very low external quantum efficiency and no spectral selectivity. Here we report a dramatic enhancement of the overall quantum efficiency and spectral selectivity that enables multicolour photodetection, by coupling graphene with plasmonic nanostructures. We show that metallic plasmonic nanostructures can be integrated with graphene photodetectors to greatly enhance the photocurrent and external quantum efficiency by up to 1,500%. Plasmonic nanostructures of variable resonance frequencies selectively amplify the photoresponse of graphene to light of different wavelengths, enabling highly specific detection of multicolours. Being atomically thin, graphene photodetectors effectively exploit the local plasmonic enhancement effect to achieve a significant enhancement factor not normally possible with traditional planar semiconductor materials.


Assuntos
Eletrônica/métodos , Grafite/química , Nanoestruturas/química , Nanotecnologia/métodos , Ressonância de Plasmônio de Superfície/métodos , Cor , Eletrônica/instrumentação , Desenho de Equipamento , Luz , Nanoestruturas/ultraestrutura , Nanotecnologia/instrumentação , Dispositivos Ópticos , Polimetil Metacrilato/química , Semicondutores , Ressonância de Plasmônio de Superfície/instrumentação
19.
Nano Lett ; 11(6): 2555-9, 2011 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-21548551

RESUMO

Graphene transistors are of considerable interest for radio frequency (rf) applications. In general, transistors with large transconductance and drain current saturation are desirable for rf performance, which is however nontrivial to achieve in graphene transistors. Here we report high-performance top-gated graphene transistors based on chemical vapor deposition (CVD) grown graphene with large transconductance and drain current saturation. The graphene transistors were fabricated with evaporated high dielectric constant material (HfO(2)) as the top-gate dielectrics. Length scaling studies of the transistors with channel length from 5.6 µm to 100 nm show that complete current saturation can be achieved in 5.6 µm devices and the saturation characteristics degrade as the channel length shrinks down to the 100-300 nm regime. The drain current saturation was primarily attributed to drain bias induced shift of the Dirac points. With the selective deposition of HfO(2) gate dielectrics, we have further demonstrated a simple scheme to realize a 300 nm channel length graphene transistors with self-aligned source-drain electrodes to achieve the highest transconductance of 250 µS/µm reported in CVD graphene to date.


Assuntos
Grafite/química , Tamanho da Partícula , Propriedades de Superfície , Transistores Eletrônicos , Volatilização
20.
Nano Lett ; 11(3): 1082-6, 2011 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-21322591

RESUMO

We report an experimental investigation of the edge effect on the room-temperature transport in graphene nanoribbon and graphene sheet (both single-layer and bilayer). By measuring the resistance scaling behaviors at both low- and high-carrier densities, we show that the transport of single-layer nanoribbons lies in a strong localization regime, which can be attributed to an edge effect. We find that this edge effect can be weakened by enlarging the width, decreasing the carrier densities, or adding an extra layer. From graphene nanoribbon to graphene sheet, the data show a dimensional crossover of the transport regimes possibly due to the drastic change of the edge effect.