Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 250
Filtrar
1.
JMIR Hum Factors ; 11: e57239, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38861717

RESUMO

BACKGROUND: Overdose Fatality Review (OFR) is an important public health tool for shaping overdose prevention strategies in communities. However, OFR teams review only a few cases at a time, which typically represent a small fraction of the total fatalities in their jurisdiction. Such limited review could result in a partial understanding of local overdose patterns, leading to policy recommendations that do not fully address the broader community needs. OBJECTIVE: This study explored the potential to enhance conventional OFRs with a data dashboard, incorporating visualizations of touchpoints-events that precede overdoses-to highlight prevention opportunities. METHODS: We conducted 2 focus groups and a survey of OFR experts to characterize their information needs and design a real-time dashboard that tracks and measures decedents' past interactions with services in Indiana. Experts (N=27) were engaged, yielding insights on essential data features to incorporate and providing feedback to guide the development of visualizations. RESULTS: The findings highlighted the importance of showing decedents' interactions with health services (emergency medical services) and the justice system (incarcerations). Emphasis was also placed on maintaining decedent anonymity, particularly in small communities, and the need for training OFR members in data interpretation. The developed dashboard summarizes key touchpoint metrics, including prevalence, interaction frequency, and time intervals between touchpoints and overdoses, with data viewable at the county and state levels. In an initial evaluation, the dashboard was well received for its comprehensive data coverage and its potential for enhancing OFR recommendations and case selection. CONCLUSIONS: The Indiana touchpoints dashboard is the first to display real-time visualizations that link administrative and overdose mortality data across the state. This resource equips local health officials and OFRs with timely, quantitative, and spatiotemporal insights into overdose risk factors in their communities, facilitating data-driven interventions and policy changes. However, fully integrating the dashboard into OFR practices will likely require training teams in data interpretation and decision-making.


Assuntos
Overdose de Drogas , Grupos Focais , Design Centrado no Usuário , Humanos , Overdose de Drogas/prevenção & controle , Overdose de Drogas/epidemiologia , Indiana/epidemiologia , Inquéritos e Questionários
2.
Diabet Med ; 41(7): e15339, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679910

RESUMO

AIM: To summarise, in a narrative review, published data on hypoglycaemia occurrence with basal insulin therapy in adults with type 1 diabetes treated with basal-bolus insulin regimens in treat-to-target randomised controlled trials. METHODS: Data were included from 21 eligible trials, which mainly used self-measured blood glucose or plasma glucose to detect hypoglycaemia. RESULTS: All-day self-measured blood glucose or plasma glucose level 2 (glucose threshold of 3.1 or 3.0 mmol/L) and level 3 (severe, requiring assistance) hypoglycaemic events were reported, respectively, by a range of 69.0%-97.5% and 0%-13.4% adults when receiving basal-bolus insulin therapy, with rates of 10.6-68.1 and 0.0-0.4 events per patient-year of exposure, respectively. Hypoglycaemia rates measured using continuous glucose monitoring (three studies) were numerically, yet consistently, higher than with either other method, except when limiting to symptomatic events. Nocturnal hypoglycaemia rates were generally less than 30% of the equivalent all-day rates. CONCLUSIONS: Differences across the studies in design (e.g., titration targets) and participant characteristics hindered comparison of hypoglycaemia rates by insulin formulation. Consequently, few trends were identified by insulin formulation, study methodology or individuals' characteristics, suggesting that further research is required to identify treatment strategies that facilitate development of individualised recommendations to lower hypoglycaemia risk. These findings are useful to understand hypoglycaemia risk with available basal insulin therapies when used in a multiple daily injection regimen, as well as to provide context for the results of ongoing and future clinical trials, including those for two once-weekly basal insulins, insulin icodec and basal insulin Fc.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemia , Hipoglicemiantes , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Glicemia/metabolismo , Glicemia/análise , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto , Automonitorização da Glicemia
3.
Postgrad Med ; 136(3): 246-254, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38497381

RESUMO

Use of innovative technologies such as continuous glucose monitoring (CGM) and insulin delivery systems have been shown to be safe and effective in helping patients with diabetes achieve significantly improved glycemic outcomes compared to their previous therapies. However, these technologies are underutilized in many primary care practices. This narrative review discusses some of the clinical and economic benefits of tubeless insulin delivery devices and discusses how this technology can overcome the main obstacles inherent to use of conventional insulin delivery devices.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/sangue , Insulina/administração & dosagem , Insulina/uso terapêutico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Automonitorização da Glicemia/métodos , Glicemia/análise
4.
J Diabetes Sci Technol ; : 19322968241232709, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38420944

RESUMO

BACKGROUND: SAR341402 insulin aspart (SAR-Asp) is a rapid-acting insulin analog developed as an interchangeable biosimilar to the marketed insulin aspart reference product (NovoLog; NN-Asp). GEMELLI X was a randomized controlled trial to assess outcomes with a biosimilar in line with the US Food and Drug Administration requirements for designation as an interchangeable biosimilar. This report assessed whether multiple switches between SAR-Asp and NN-Asp lead to equivalent safety and efficacy compared with continuous use of NN-Asp in adults with type 1 diabetes (T1D) treated with multiple daily injections, using once-daily insulin glargine U100 (Lantus) as the basal insulin. METHODS: This open-label randomized (1:1), parallel-group, phase 3 trial compared four × four weeks of alternating use of individually titrated SAR-Asp and NN-Asp (NN-Asp for first four weeks, SAR-Asp in last four weeks; switching group) vs 16 weeks of continuous use of NN-Asp (nonswitching group). End points included pharmacokinetics, immunogenicity, adverse events, hypoglycemia, insulin dose, and change in efficacy parameters. RESULTS: Of the 210 patients randomized, 200 (95.5%) completed the trial. Patients assigned to switching group (n = 104) and nonswitching group (n = 106) showed similar safety and tolerability, including anti-insulin aspart antibody responses, adverse events, and hypoglycemia. At week 16, there was no relevant difference between switching vs nonswitching groups in the change from baseline in glycated hemoglobin (least square [LS] mean difference = 0.05% [95% confidence interval [CI] = -0.13, 0.22]; 0.50 mmol/mol [-1.40, 2.39]), fasting plasma glucose (LS mean difference = 0.23 mmol/L [95% CI = -1.08, 1.53]; 4.12 mg/dL [-19.38, 27.62]), and changes in insulin dosages. CONCLUSIONS: Alternating doses of SAR-Asp and NN-Asp compared with continuous use of NN-Asp showed similar safety, immunogenicity, and clinical efficacy in adults with T1D. This study supports interchangeability between SAR-Asp and NN-Asp in T1D management.

5.
Genome Biol ; 25(1): 11, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38191487

RESUMO

BACKGROUND: Transcription factors bind DNA in specific sequence contexts. In addition to distinguishing one nucleobase from another, some transcription factors can distinguish between unmodified and modified bases. Current models of transcription factor binding tend not to take DNA modifications into account, while the recent few that do often have limitations. This makes a comprehensive and accurate profiling of transcription factor affinities difficult. RESULTS: Here, we develop methods to identify transcription factor binding sites in modified DNA. Our models expand the standard A/C/G/T DNA alphabet to include cytosine modifications. We develop Cytomod to create modified genomic sequences and we also enhance the MEME Suite, adding the capacity to handle custom alphabets. We adapt the well-established position weight matrix (PWM) model of transcription factor binding affinity to this expanded DNA alphabet. Using these methods, we identify modification-sensitive transcription factor binding motifs. We confirm established binding preferences, such as the preference of ZFP57 and C/EBPß for methylated motifs and the preference of c-Myc for unmethylated E-box motifs. CONCLUSIONS: Using known binding preferences to tune model parameters, we discover novel modified motifs for a wide array of transcription factors. Finally, we validate our binding preference predictions for OCT4 using cleavage under targets and release using nuclease (CUT&RUN) experiments across conventional, methylation-, and hydroxymethylation-enriched sequences. Our approach readily extends to other DNA modifications. As more genome-wide single-base resolution modification data becomes available, we expect that our method will yield insights into altered transcription factor binding affinities across many different modifications.


Assuntos
Regulação da Expressão Gênica , Fatores de Transcrição , Epigenômica , DNA , Epigênese Genética
6.
Diabetes Technol Ther ; 26(4): 263-275, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38194227

RESUMO

Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively, and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels are suggested that enable the collection of comparator data with these characteristics. This work is an important step toward establishing a future standard for the performance evaluation of CGM systems.


Assuntos
Glicemia , Hiperglicemia , Humanos , Automonitorização da Glicemia/métodos , Monitoramento Contínuo da Glicose , Hiperglicemia/diagnóstico , Hiperglicemia/prevenção & controle
7.
Diabetes Obes Metab ; 26(2): 540-547, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37880868

RESUMO

AIM: To assess whether multiple switches between SAR341402 biosimilar insulin aspart (SAR-Asp) and the insulin aspart reference product (NovoLog; NN-Asp) leads to equivalent pharmacokinetic (PK) exposure compared with continuous use of NN-Asp in adults with type 1 diabetes (T1D). MATERIALS AND METHODS: This multicentre, open-label, phase 3 study randomized (1:1) 210 subjects with T1D treated with once-daily insulin glargine U100 as basal insulin to four 4-week periods of alternating multiple daily injections of SAR-Asp and NN-Asp (NN-Asp for the first 4 weeks, SAR-Asp in the last 4 weeks; switching group) versus 16 weeks of continuous NN-Asp (non-switching group). At week 16, a single dose (0.15 U/kg) of SAR-Asp in the switching group (n = 95) or NN-Asp in the non-switching group (n = 105) was given in the morning before breakfast. Primary PK endpoints were area under the plasma concentration curve (AUC) and maximum plasma concentration (Cmax ) of SAR-Asp versus NN-Asp after the single dose at week 16. RESULTS: The extent of PK exposure was similar between the two treatments (SAR-Asp in the switching group and NN-Asp in the non-switching group) at week 16, with point estimates of treatment ratios close to 1. The 90% confidence intervals for AUC treatment ratios were contained within 0.8-1.25. For Cmax in the primary analysis set, the upper confidence limit was 1.32. This was because of the profiles of three participants with implausible high values. A prespecified sensitivity analysis excluding implausible values showed results contained within 0.8-1.25. CONCLUSIONS: PK exposure of SAR-Asp (switching group) and reference NN-Asp (non-switching group) were similar, supporting interchangeability between these two insulin aspart products.


Assuntos
Medicamentos Biossimilares , Diabetes Mellitus Tipo 1 , Adulto , Humanos , Medicamentos Biossimilares/administração & dosagem , Medicamentos Biossimilares/farmacocinética , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/farmacocinética , Insulina/farmacocinética , Insulina Aspart/farmacocinética , Insulina Glargina/farmacocinética
9.
Diabetes Ther ; 14(5): 883-897, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37029268

RESUMO

INTRODUCTION: To evaluate time in range metrics and HbA1c in people with type 2 diabetes (T2D) treated with ultra rapid lispro (URLi) using continuous glucose monitoring (CGM) for the first time in this population. METHODS: This was a Phase 3b, 12-week, single-treatment study in adults with T2D on basal-bolus multiple daily injection (MDI) therapy using basal insulin glargine U-100 along with a rapid-acting insulin analog. Following a 4-week baseline period, 176 participants were newly treated with prandial URLi. Participants used unblinded CGM (Freestyle Libre). Primary endpoint was time in range (TIR) (70-180 mg/dl) during the daytime period at Week 12 compared to baseline with gated secondary endpoints of HbA1c change from baseline and 24-h TIR (70-180 mg/dl). RESULTS: Improved glycemic control was observed at Week 12 versus baseline including mean daytime TIR (change from baseline [Δ] 3.8%; P = 0.007), HbA1c (Δ - 0.44%; P < 0.001), and 24-h TIR (Δ 3.3%; P = 0.016) with no significant difference in time below range (TBR). After 12 weeks, there was a statistically significant decrease in postprandial glucose incremental area under curve, overall, across all meals, within 1 h (P = 0.005) or 2 h (P < 0.001) after the start of a meal. Basal, bolus, and total insulin dose were intensified with increased bolus/total dose ratio at Week 12 (50.7%) versus baseline (44.5%; P < 0.001). There were no severe hypoglycemia events during the treatment period. CONCLUSIONS: In people with T2D, URLi in an MDI regimen was efficacious with improved glycemic control including TIR, HbA1c, and postprandial glucose without increased hypoglycemia/TBR. CLINICAL TRIAL REGISTRATION NUMBER: NCT04605991.

10.
Drug Alcohol Depend ; 247: 109891, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37120921

RESUMO

BACKGROUND: The United States continues to experience unprecedented rates of overdose mortality and need to identify effective policies or practices that can be implemented. This study aims to measure the prevalence, frequency, timing, and rate of touchpoints that occurred prior to a fatal overdose where communities might intervene. METHODS: In collaboration with Indiana state government, we conducted record-linkage of statewide administrative datasets to vital records (January 1, 2015, through August 26, 2022) to identify touchpoints (jail booking, prison release, prescription medication dispensation, emergency department visits, and emergency medical services). We examined touchpoints within 12-months prior to a fatal overdose among an adult cohort and explored variation over time and by demographic characteristics. RESULTS: Over the 92-month study period there were 13,882 overdose deaths (89.3% accidental poisonings, X40-X44) in our adult cohort that were record-linked to multiple administrative datasets and revealed nearly two-thirds (64.7%; n=8980) experienced an emergency department visit, the most prevalent touchpoint followed by prescription medication dispensation, emergency medical services responses, jail booking, and prison release. However, with approximately 1 out of every 100 returning citizens dying from drug overdose within 12-months of release, prison release had the highest touchpoint rate followed by emergency medical services responses, jail booking, emergency department visits, and prescription medication dispensation. CONCLUSION: Record-linking administrative data from routine practice to vital records from overdose mortality is a viable means of identifying where resources should be situated to reduce fatal overdose, with potential to evaluate the effectiveness of overdose prevention efforts.


Assuntos
Overdose de Drogas , Serviços Médicos de Emergência , Medicamentos sob Prescrição , Adulto , Humanos , Estados Unidos , Indiana/epidemiologia , Overdose de Drogas/epidemiologia , Serviço Hospitalar de Emergência , Prisões , Analgésicos Opioides
12.
Diabetes Obes Metab ; 25(5): 1351-1360, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36692230

RESUMO

AIMS: To perform an integrated analysis of the safety and efficacy of dasiglucagon, a glucagon analogue available in a ready-to-use aqueous formulation, to treat severe hypoglycaemia (SH) in type 1 diabetes (T1D). MATERIALS AND METHODS: An integrated analysis of dasiglucagon safety was conducted on data from two placebo-controlled trials (placebo-controlled pool) and two placebo-controlled and four non-placebo-controlled trials (broad pool) in adults with T1D. An integrated analysis of dasiglucagon efficacy was conducted of pooled data and within demographic subgroups from the two placebo-controlled and two non-placebo-controlled trials in adults with T1D. RESULTS: Dasiglucagon had a similar safety and tolerability profile to that of reconstituted glucagon. In the placebo-controlled datasets, no serious adverse events (AEs), AEs leading to withdrawal from the trial, or deaths were reported. The most common causally related AEs were nausea (56.5%) and vomiting (24.6%). The broad pool safety analysis showed similar results. Dasiglucagon efficacy in time to plasma glucose recovery from insulin-induced SH was similar to that of reconstituted glucagon (median 10.0 and 12.0 minutes, respectively) and superior to placebo (median 40.0 minutes; P < 0.0001). The median recovery time was consistent across all placebo-controlled trial subgroups. CONCLUSIONS: Dasiglucagon was well tolerated and effective as a rapid rescue agent for insulin-induced SH in people with T1D.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Insulinas , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon , Hipoglicemiantes/efeitos adversos , Glicemia , Insulinas/efeitos adversos
13.
J Diabetes Sci Technol ; 17(2): 449-457, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34889142

RESUMO

Innovations in syringe and pen needle (PN) technology over the last 100 years have led to important advances in insulin delivery for people with diabetes, paralleling the strides made in developing recombinant DNA human insulin and insulin analogs with varying onset and duration of action. In this review, the history of advances in insulin delivery is described, focusing on progress in syringe, needle, and PN technologies. The early glass and metal syringes that required sterilization by boiling have been replaced by disposable, single-use syringes or pens with clear labeling for precise insulin dosing. The early needles ranging in length from 19 to 26 mm that required manual sharpening against a whetstone have been replaced by syringe needles of 6 mm and PNs of 4 mm in length as slender as 34 gauge. Imaging studies using ultrasound and computed tomography measured the thickness of skin and subcutaneous tissue layers to show feasibility of targeted insulin administration with shorter needles. These developments, coupled with innovations in needle/PN wall and tip structure, have led to improved injection experience for people with diabetes. It is also important to acknowledge the role of injection technique education, together with these advances in injection technology, for improving clinical outcomes and patient satisfaction. With continued projected growth of diabetes prevalence, particularly in developing countries where expensive and complex insulin delivery systems may not be practical, insulin syringes and pens will continue to serve as reliable and cost-effective means of insulin delivery for people with diabetes.


Assuntos
Diabetes Mellitus , Insulina , Humanos , Injeções Subcutâneas , Diabetes Mellitus/tratamento farmacológico , Satisfação do Paciente , Pele , Insulina Regular Humana/uso terapêutico
14.
J Diabetes Sci Technol ; 17(5): 1226-1242, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35348391

RESUMO

BACKGROUND: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. METHODS: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low-glucose and low-glucose hypoglycemia; very high-glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. RESULTS: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. CONCLUSION: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.


Assuntos
Hiperglicemia , Hipoglicemia , Adulto , Humanos , Glicemia , Automonitorização da Glicemia , Hipoglicemia/diagnóstico , Hiperglicemia/diagnóstico , Glucose
15.
J Diabetes Sci Technol ; 17(4): 1066-1076, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35369773

RESUMO

PURPOSE: A proposal that an Insulin Advisory Committee develop insulin titration guidelines 100 years after its discovery. FINDINGS: Glucose control metrics remain poor despite significant advances in diabetes technology. SUMMARY: A century after the introduction of insulin, health care providers and patients with type 1 diabetes have worldwide access to a variety of insulin delivery devices (IDDs), glucose monitors, bolus calculators (BCs), continuous glucose monitors (CGMs), and automated insulin delivery (AID) systems. However, these advances have not enabled most patients to achieve today's clear A1c and time-in-range goals. Much of this failure arises from the lack of clear insulin titration guidelines for determining appropriate insulin doses. The lack of dosing clarity results in local physicians, clinics, and individual patients managing insulin titrations as they see fit, creating significant inefficiencies for reaching recommended glycemic goals. This review (1) details the widespread problems generated by nonphysiological dose settings in today's BCs, insulin pumps, and AID systems; (2) presents a method to develop and implement optimized total daily doses of insulin to correct the most common problem of hyperglycemia; (3) discusses using large device databases to provide clear insulin titration guidelines that optimize BC settings from an optimized total daily dose (TDD) of insulin for patients with T1D; and (4) recommends the formation of an Insulin Advisory Committee to clarify the steps to take toward universal insulin titration guidelines, optimized BC settings, and a systematic logic for their use in insulin delivery devices.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina , Hipoglicemiantes , Insulina Regular Humana/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina
16.
J Diabetes Sci Technol ; 17(4): 962-967, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35466707

RESUMO

BACKGROUND: Accuracy of a seventh-generation "G7" continuous glucose monitoring (CGM) system was evaluated in children and adolescents with type 1 diabetes (T1D). METHODS: Sensors were worn on the upper arm and abdomen. The CGM data were available from 127 of 132 participants, ages 7 to 17 years, across 10.5 days of use, various glucose concentration ranges, and various rates of glucose change for comparisons with temporally matched venous blood glucose measurements (YSI). Data were also available from 28 of 32 participants, ages 2 to 6 years, for whom capillary (fingerstick) blood provided comparator glucose values. Accuracy metrics included the mean absolute relative difference (MARD) between CGM and comparator glucose pairs, the proportion of CGM values within 15 mg/dL or 15% of comparator values <100 or ≥100 mg/dL, respectively, and the analogous %20/20 and %30/30 agreement rates. RESULTS: For participants aged 7 to 17, a total of 15 437 matched pairs were obtained from 122 arm-placed and 118 abdomen-placed sensors. For arm-placed sensors, the overall MARD was 8.1% and overall %15/15, %20/20, and %30/30 agreement rates were 88.8%, 95.3%, and 98.7%, respectively. For abdomen-placed sensors, the overall MARD was 9.0% and overall %15/15, %20/20, and %30/30 agreement rates were 86.0%, 92.9%, and 97.7%, respectively. Good accuracy was maintained across wear days, glucose ranges, and rates of glucose change. Among those aged 2 to 6, a total of 343 matched pairs provided an overall MARD of 9.3% and an overall %20/20 agreement rate of 91.5%. CONCLUSIONS: The G7 CGM placed on the arm or abdomen was accurate in children and adolescents with T1D. NCT#: NCT04794478.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Criança , Humanos , Abdome , Glicemia , Automonitorização da Glicemia , Reprodutibilidade dos Testes
17.
Diabetes Technol Ther ; 25(2): 143-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36342853

RESUMO

Insulin exposure varies over 3 days of insulin infusion set (IIS) wear making day-to-day insulin dosing challenging for people with diabetes (PWD). Here we report insulin pharmacodynamic (PD) and pharmacokinetic (PK) data extending these observations to 7 days of IIS wear. PWD (A1C ≤8.5%, C-peptide <0.6 nmol/L, ≥6 months pump use) were enrolled in a crossover euglycemic clamp pilot study comparing conventional Teflon angled IISs with an investigational extended-wear IIS. PK/PD data from six participants were obtained for 5 h postbolus. Although PD data were unstable, PK profiles (pooled data from both groups) of insulin lispro (0.15 U/kg bolus) showed statistically significant progressive decreases from days 0 to 7 for tmax (P < 0.001), Cmax (P < 0.05), and mean residence time (P < 0.0001). Area under the insulin concentration curve (AUC0-300) declined by ∼24% from days 0 to 7 (P < 0.05). These results confirm/extend previous observations showing progressive acceleration of insulin exposure over IIS wear time. This may have implications for PWD and designers of closed-loop algorithms, although larger studies are necessary to confirm this. The study was registered in clinicaltrials.gov (NCT04398030).


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus , Humanos , Insulina , Hipoglicemiantes , Projetos Piloto , Insulina Lispro , Insulina Regular Humana/uso terapêutico , Técnica Clamp de Glucose , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Glicemia
18.
Nat Med ; 28(10): 2092-2099, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36192552

RESUMO

Hyperglucagonemia contributes to hyperglycemia in patients with type 1 diabetes (T1D); however, novel therapeutics that block glucagon action could improve glycemic control. This phase 2 study evaluated the safety and efficacy of volagidemab, an antagonistic monoclonal glucagon receptor (GCGR) antibody, as an adjunct to insulin therapy in adults with T1D. The primary endpoint was change in daily insulin use at week 12. Secondary endpoints included changes in hemoglobin A1c (HbA1c) at week 13, in average daily blood glucose concentration and time within target range as assessed by continuous blood glucose monitoring (CGM) and seven-point glucose profile at week 12, incidence of hypoglycemic events, the proportion of subjects who achieve HbA1c reduction of ≥0.4%, volagidemab drug concentrations and incidence of anti-drug antibodies. Eligible participants (n = 79) were randomized to receive weekly subcutaneous injections of placebo, 35 mg volagidemab or 70 mg volagidemab. Volagidemab produced a reduction in total daily insulin use at week 12 (35 mg volagidemab: -7.59 units (U) (95% confidence interval (CI) -11.79, -3.39; P = 0.040 versus placebo); 70 mg volagidemab: -6.64 U (95% CI -10.99, -2.29; P = 0.084 versus placebo); placebo: -1.27 U (95% CI -5.4, 2.9)) without meeting the prespecified significance level (P < 0.025). At week 13, the placebo-corrected reduction in HbA1c percentage was -0.53 (95% CI -0.89 to -0.17, nominal P = 0.004) in the 35 mg volagidemab group and -0.49 (95% CI -0.85 to -0.12, nominal P = 0.010) in the 70 mg volagidemab group. No increase in hypoglycemia was observed with volagidemab therapy; however, increases in serum transaminases, low-density lipoprotein (LDL)-cholesterol and blood pressure were observed. Although the primary endpoint did not meet the prespecified significance level, we believe that the observed reduction in HbA1c and tolerable safety profile provide a rationale for further randomized studies to define the long-term efficacy and safety of volagidemab in patients with T1D.


Assuntos
Anticorpos Monoclonais Humanizados , Diabetes Mellitus Tipo 1 , Receptores de Glucagon , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Glucagon , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/uso terapêutico , Humanos , Insulina/uso terapêutico , Lipoproteínas LDL/uso terapêutico , Receptores de Glucagon/antagonistas & inibidores , Transaminases/uso terapêutico , Resultado do Tratamento
19.
J Diabetes Sci Technol ; : 19322968221110622, 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35833638

RESUMO

BACKGROUND: Technosphere Insulin (TI) is an ultra-rapid-acting inhaled insulin. This study assessed the mean peak two-hour postprandial glucose concentration with the initial TI dose (dose 1) calculated per the current label (United State Prescribing Information) compared with a ~2× higher dose (dose 2). Secondary objectives were to evaluate hypoglycemia within the two-hour postprandial period, evaluate change in forced expiratory volume in one second (FEV1) before and after the two-hour postprandial period, and monitor for other adverse events. METHODS: Twenty patients with diabetes, on basal-bolus insulin therapy, received an initial dose 1 of TI followed by the higher dose 2, one to three days later. Subjects received an identical meal for both visits, and TI doses were administered immediately prior to the meal. RESULTS: The higher dose 2 provided significant reductions in mean postprandial glucose excursion (PPGE) in the two-hour postprandial period starting from 45 minutes (P = .008) to 120 minutes (P < .0001). Mean peak glucose was reduced from 228.6 to 179.3 mg/dL (P < .001) at two hours. Two hypoglycemic events (one level 1, one level 2) were observed in a single subject during the two-hour postprandial period with dose 2. There were no significant changes in FEV1 after either dose of TI. CONCLUSIONS: The higher dose 2 reduced PPGE versus the current label recommended dose 1 within the two-hour postprandial timeframe without any new safety concerns. When confirmed with a larger study, this higher TI dosing recommendation may help patients and clinicians minimize immediate postprandial hyperglycemia when titrating TI for prandial glucose control.

20.
Diabetes Obes Metab ; 24(8): 1617-1622, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35491520

RESUMO

AIMS: To provide real-world data on the addition of basal insulin (BI) in people with type 2 diabetes mellitus (PWD2) suboptimally controlled with glucagon-like peptide-1 receptor agonist (GLP-1RA) therapy. However, real-world data on the addition of BI to GLP-1RA therapy are limited. MATERIALS AND METHODS: We used a US electronic medical record data source (IBM® Explorys®) that includes approximately 4 million PWD2 to assess the real-world impact of adding the second-generation BI analogue insulin glargine 300 U/mL (Gla-300) to GLP-1RA therapy. Insulin-naïve PWD2 receiving GLP-1RAs who also received Gla-300 between March 1, 2015 and September 30, 2019 were identified; participants were required to have data for ≥12 months before, and ≥6 months after, addition of Gla-300. RESULTS: The mean (standard deviation [SD]) age of participants (N = 271) was 57.9 (10.8) years. Baseline glycated haemoglobin (HbA1c) was 9.16% and was significantly reduced (-0.97 [SD 1.60]%; P < 0.0001) after addition of Gla-300; a significant increase in the proportion of PWD2 achieving HbA1c control was observed after addition of Gla-300 (HbA1c <7.0%: 4.80% vs. 22.14%, P < 0.0001; HbA1c <8.0%: 19.56% vs. 51.29%, P < 0.0001). The incidence of overall (8.49% vs. 9.59%; P = 0.513) and inpatient/emergency department (ED)-associated hypoglycaemia (0.37% vs. 0.74%; P = 1.000), as well as overall (0.33 vs. 0.46 per person per year [PPPY]; P = 0.170) and inpatient/ED-associated hypoglycaemia events (0.01 vs. 0.04 PPPY; P = 0.466) were similar before and after addition of Gla-300. CONCLUSIONS: In US real-world clinical practice, adding Gla-300 to GLP-1RA significantly improved glycaemic control without significantly increasing hypoglycaemia in PWD2. Further research into the effect of adding Gla-300 to GLP-1RA therapy is warranted.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Peptídeo 1 Semelhante ao Glucagon/uso terapêutico , Receptor do Peptídeo Semelhante ao Glucagon 1/uso terapêutico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina/uso terapêutico , Insulina Glargina/efeitos adversos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA