Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-39087741

RESUMO

BACKGROUND: Perclose ProGlide (PPG) Suture-Mediated Closure System™ is safe and can reduce time to hemostasis following procedures requiring arterial access. AIMS: We aimed to compare PPG to figure of 8 suture in patients who underwent interventional catheter procedures requiring large bore venous access (LBVA) (≥13 French). METHODS: In this physician-initiated, randomized, single-center study [clinicaltrials.gov ID: NCT04632641], single-stick venous access was obtained under ultrasound guidance. Eligible patients were randomized 1:1, and 100 subjects received allocated treatment to either PPG (n = 47) or figure of 8 suture (n = 53). No femoral arterial access was used in any patient. Primary outcomes were time to achieve hemostasis (TTH) and time to ambulation (TTA). Secondary outcomes were time to discharge (TTD) and vascular-related complications and mortality. Wilcoxon rank-sum test was used to compare TTH, TTA, and TTD. RESULTS: TTH (minutes) was significantly lower in PPG versus figure of 8 suture [median, (Q1, Q3)] [7 (2,10) vs. 11 (10,15) respectively, p < 0.001]. TTA (minutes) was significantly lower in PPG compared to figure of 8 suture [322 (246,452) vs. 403 (353, 633) respectively, p = 0.005]. TTD (minutes) was not significantly different between the PPG and figure of 8 suture arms [1257 (1081, 1544) vs. 1338 (1171,1435), p = 0.650]. There was no difference in minor bleeding or access site hematomas between both arms. No other vascular complications or mortality were reported. CONCLUSION: PPG use had lower TTH and TTA than figure of 8 suture in a population of patients receiving LBVA procedures. This may encourage same-day discharge in these patients.

3.
Front Cardiovasc Med ; 11: 1416149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39027001

RESUMO

Background: Vasospastic angina usually presents with intermittent episodes of chest pain. It can rarely be associated with the perception of phantom odors. Case summary: A 69-year-old woman presented for evaluation of intermittent shortness of breath and chest pain. She reported that she often experienced an abnormal smell sensation just prior to the event. The patient had abnormal smell sensation and shortness of breath at the initiation of exercise stress echocardiography with transient electrocardiographic changes and new regional wall motion abnormalities. Subsequent invasive coronary angiography showed no obstructive epicardial coronary artery disease. The patient was started on calcium channel blocker therapy with resolution of symptoms. Conclusion: Phantom odor perception has been rarely reported as an angina-equivalent symptom. Clinicians should have a high index of suspicion in patients presenting with atypical anginal symptoms.

4.
Struct Heart ; 8(3): 100278, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799807

RESUMO

Background: The current clinical practice standard is 10% to 20% oversizing of self-expanding valves in transcatheter aortic valve replacement. We aimed to determine whether >20% oversizing of self-expanding valves (Medtronic Evolut) would lead to better valve performance with similar or better outcomes. Methods: From October 2011 to December 2016, we approached all transcatheter aortic valve replacement patients with a conscious attempt at large oversizing (>20%). The most common valve used, excluding those used in valve-in-valve patients, was the 29-mm Evolut R (29%). We used a retrospective chart review to compare moderate oversizing (group 1; 10% to 20%) with large oversizing (group 2; >20%). Results: Of 556 patients, 45% were male; the overall mean Society of Thoracic Surgeons risk score was 5.8 ± 3.8. Eighty-five (15%) patients needed a pacemaker, and 21 (3.8%) developed significant paravalvular leak. Mean oversizing was 20.3% ± 6.0%, with 41.4% of patients included in group 1 and 54.5% in group 2. Incidences of complications in group 2 vs. group 1 were as follows: a) paravalvular leak (2.0 vs. 6.1%; odds ratio = 0.31, p = 0.01), b) pacemaker (15 vs. 14%), c) gastrointestinal bleed (n = 4 vs. 0; 1.3 vs. 0.0%; p = 0.03), d) annular dissection (n = 1 vs. 0; 0.3 vs. 0%; p = 0.29), e) mortality (n = 5 vs. 4; 1.6 vs. 1.7%). Incidence of paravalvular leak was higher in those who died than survivors (13 vs. 1.3%; p ≤ 0.0001). Conclusions: These data suggest that, in current self-expanding valves, >20% oversizing delivers a significantly lower prevalence of paravalvular leak without an increase in other complications. Since paravalvular leak is associated with increased mortality, >20% oversizing may represent a superior prosthesis choice.

5.
Cardiovasc Revasc Med ; 67: 1-7, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38599918

RESUMO

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/instrumentação , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Tempo , Pesquisas sobre Atenção à Saúde , Recuperação de Função Fisiológica , Masculino , Hemodinâmica , Feminino , Idoso
6.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38639690

RESUMO

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Feminino , Masculino , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Desenho de Prótese , Valor Preditivo dos Testes , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Hemodinâmica , Readmissão do Paciente , Ecocardiografia
8.
Catheter Cardiovasc Interv ; 103(1): 106-114, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37983656

RESUMO

BACKGROUND: Atherectomy use in treatment of femoropopliteal disease has significantly increased despite scant evidence of benefit to long-term clinical outcomes. AIMS: We investigated the clinical benefits of atherectomy over standard treatment for femoropopliteal interventions. METHODS: Using data from the Society of Vascular Surgery's Vascular Quality Initiative (VQI) registry, we identified patients who underwent isolated femoropopliteal interventions for occlusive disease. We compared 13,423 patients treated with atherectomy with 47,371 receiving standard treatment; both groups were allowed definitive treatment with a drug-coated balloon or stenting. The primary endpoint was major adverse limb events (MALEs), which is a composite of target vessel re-occlusion, ipsilateral major amputation, and target vessel revascularization. RESULTS: Mean age was 69 ± 11 years, and patients were followed for a median of 30 months. Overall rates of complications were slightly higher in the atherectomy group than the standard treatment group (6.2% vs. 5.9%, p < 0.0001). In multivariable analysis, after adjusting for demographic and clinical covariates, atherectomy use was associated with a 13% reduction in risk of MALEs (adjusted odds ratio [aOR]: 0.87; 95% confidence interval [CI]: 0.77-0.98). Rates of major and minor amputations were significantly lower in the atherectomy group (3.2% vs. 4.6% and 3.3% vs. 4.3%, respectively, both p < 0.001), primarily driven by a significantly decreased risk of major amputations (aOR 0.69; 95% CI: 0.52-0.91). There were no differences in 30-day mortality, primary patency, and target vessel revascularization between the atherectomy and standard treatment groups. CONCLUSIONS: In adults undergoing femoropopliteal interventions, the use of atherectomy was associated with a reduction in MALEs compared with standard treatment.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Aterectomia/efeitos adversos , Sistema de Registros , Grau de Desobstrução Vascular , Fatores de Risco
9.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
10.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37902145

RESUMO

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos de Viabilidade , Estudos Prospectivos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia
12.
Am J Cardiol ; 207: 322-327, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37774473

RESUMO

The age-based trends in-hospital outcomes in patients with percutaneous left atrial appendage occlusion (LAAO) are unknown. Using the National Readmission Database from 2016 to 2019, patients who underwent LAAO were divided into 2 age groups: 60 to 79 and ≥80 years. The primary objective was to evaluate the age-based trends in the outcomes related to LAAO. The secondary objectives were to evaluate the mean cost and total cumulative cost of readmissions in both age groups in 2019. We identified 58,818 patients who underwent LAAO, of whom 36,964 (63%) were aged 60 to 79 years, and 21,854 (37%) were ≥80 years. The hospital mortality, pericardial complications, acute kidney injury, and in-hospital cardiac arrest did not change over time. The risk-adjusted postoperative stroke and bleeding requiring blood transfusion decreased in patients aged ≥80 years (p trend 0.03 for both outcomes). The length of stay decreased, and early discharge rates increased over time in both the unadjusted and risk-adjusted models in both age groups. The risk-adjusted 90-day readmission rates also decreased in patients aged ≥80 years. The inflation-adjusted cost did not change over time on the unadjusted and adjusted analyses. The total cumulative all-cause 90-readmission cost for both groups in 2019 was $31.7 million. Most outcomes after LAAO either improved or did not change from 2016 to 2019. Hospital mortality has remained <0.5% consistently since 2016. The risk-adjusted postoperative stroke, bleeding, and 90-day readmission rates improved in elderly vulnerable patients aged ≥80 years. The inflation-adjusted cost did not improve despite the decreasing length of stay and improving early discharge rates.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Humanos , Pessoa de Meia-Idade , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Hemorragia/complicações , Pericárdio , Resultado do Tratamento
13.
J Vasc Surg Cases Innov Tech ; 9(3): 101177, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37388666

RESUMO

We describe a 74-year-old male with delayed onset of acute left upper extremity ischemia after blunt chest trauma with left clavicular fracture, resulting in left subclavian artery injury, including pseudoaneurysm formation, intramural hematoma, thrombosis, and distal embolization to the brachial artery. The patient presented with left upper extremity pain, forearm and hand numbness, and digital cyanosis. The patient was treated with a hybrid approach, consisting of transfemoral percutaneous deployment of a covered stent in the left subclavian artery and concomitant surgical thrombectomy of the left brachial artery, resulting in excellent recovery and resolution of symptoms.

14.
Open Heart ; 10(1)2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37173100

RESUMO

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Qualidade de Vida , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento
15.
Aorta (Stamford) ; 11(2): 50-56, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37257485

RESUMO

BACKGROUND: Although uncomplicated Type B aortic dissection (uTBAD) is traditionally treated with optimal medical therapy (OMT) as per guidelines, recent studies, performed primarily in interventional radiology or surgical operating rooms, suggest superiority of thoracic endovascular aortic repair (TEVAR) over OMT due to recent advancements in endovascular technologies. We report a large, single-center, case control study of TEVAR versus OMT in this population, undertaken solely in a cardiac catheterization laboratory (CCL) with a cardiologist and surgeon. We aimed to determine if TEVAR for uTBAD results in better outcomes compared with OMT. METHODS: This was a retrospective chart review of all patients with uTBAD during the last 13 years, with 46 cases (TEVAR group) and 56 controls (OMT group). RESULTS: In the TEVAR group, the procedure duration of 2.5 hours resulted in 100% procedural success for stent placement, with 63% undergoing protective left subclavian artery bypass, 0% mortality or stroke, and a lower readmission rate (1 vs. 2%; p = 0.04 in early TEVAR cases), but a longer length of stay (12.9 vs. 8.5 days: p = 0.006). The risk of all-cause long-term mortality was markedly reduced in the TEVAR group (RR = 0.38; p = 0.01), irrespective of early (<14 days) versus late intervention. On follow-up computed tomography imaging, the false lumen stabilized or decreased in 85% of cases, irrespective of intervention timing. CONCLUSION: TEVAR performed solely in the CCL is safe and effective, with lower all-cause mortality than OMT. These data, in collaboration with previous data on TEVAR in different settings, call for consideration of an update of practice guidelines.

16.
J Patient Cent Res Rev ; 10(2): 50-57, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37091116

RESUMO

Purpose: Dual antiplatelet therapy is standard for patients undergoing percutaneous coronary intervention (PCI) with stents. Traditionally, patients swallow the loading dose of a P2Y12 inhibitor before or during PCI. Time to achieve adequate platelet inhibition after swallowing the loading dose varies significantly. Chewed tablets may allow more rapid inhibition of platelet aggregation. However, data for this strategy in patients with stable ischemic heart disease or non-ST-elevation acute coronary syndrome (NSTE-ACS) are less robust. Methods: In this single-center prospective trial, 112 P2Y12-naïve patients with stable ischemic heart disease or NSTE-ACS on aspirin therapy and who received ticagrelor after coronary angiography but before PCI were randomized to chewing (n=55) or swallowing (n=57) the ticagrelor loading dose (180 mg). Baseline variables were compared using 2-sample t-test and chi-squared/Fisher's exact tests as appropriate, with alpha set at 0.05. P2Y12 reaction units (PRU) were compared at baseline, 1 hour, and 4 hours using Wilcoxon rank-sum test. Patients then received standard ticagrelor dosing. Results: After exclusions, P2Y12 PRU in the chewed and swallowed groups at baseline, 1 hour, and 4 hours after ticagrelor loading dose were 243 vs 256 (P=0.75), 143 vs 210 (P=0.09), and 28 vs 25 (P=0.89), respectively. No differences were found in major adverse cardiac events (MACE) or major bleeding at 30 days and 1 year. Conclusions: In patients with stable ischemic heart disease or NSTE-ACS, chewing rather than swallowing ticagrelor may lead to slightly faster inhibition of platelet aggregation at 1 hour with no increase in MACE or major bleeding.

17.
Curr Probl Cardiol ; 48(8): 101733, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37040853

RESUMO

We aimed to evaluate longitudinal trends of racial and ethnic disparities in the utilization of diagnostic angiograms, percutaneous coronary intervention (PCI), and coronary artery bypass graft surgery (CABG) for non-ST elevation myocardial infarction (NSTEMI) and ST elevation myocardial infarction (STEMI). We retrospectively analyzed the National Inpatient Sample (2005-2019). The 15-year period was divided into 5, 3-year periods. Our study included 9 million adult patients (NSTEMI, 72%; STEMI, 28%). No improvement in utilization of these procedures was seen in period 5 (2017-2019) vs period 1 (2005-2007) for both NSTEMI and STEMI in non-White patients vs White patients (P > 0.05 for all comparisons), excepting in CABG for STEMI in Black patients vs White patients (difference in CABG rate: period 1, 2.6%; period 5, 1.4%; P = 0.03). Reducing disparities in PCI for NSTEMI and both PCI and CABG for STEMI in Black patients vs White patients was associated with improved outcomes.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Adulto , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Estudos Longitudinais , Estudos Retrospectivos , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Resultado do Tratamento , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia
18.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36882136

RESUMO

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
19.
J Am Heart Assoc ; 12(6): e027716, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36926995

RESUMO

Background Although sex disparities in the diagnostic evaluation and revascularization of patients with acute myocardial infarction are well documented, no study has evaluated longitudinal trends in these disparities. Methods and Results Using the National Inpatient Sample from 2005 to 2019, 9 259 932 patients with acute myocardial infarction were identified. We divided 15 years into five 3-year periods. The primary objective was to evaluate sex-based trends in the use of diagnostic angiography, percutaneous coronary intervention, and coronary artery bypass graft (CABG) among patients with non-ST-segment-elevation myocardial infarction and ST-segment-elevation myocardial infarction (STEMI) over 15 years. The secondary objective was to evaluate sex disparities in mortality, length of stay, and cost. For non-ST-segment-elevation myocardial infarction, we saw a small reduction in sex disparity in the use of all diagnostic angiography in period 5 versus period 1 (4% versus 5.3%; P<0.01), no change in sex disparity in percutaneous coronary intervention use in period 5 versus period 1 (5.6% versus 5%; P=0.16), and a widening sex disparity in CABG in period 5 versus period 1 (5.4% versus 4.4%; P<0.01). However, we noted decreasing sex disparities in the use of diagnostic angiography, percutaneous coronary intervention, and CABG for ST-segment-elevation myocardial infarction in mostly all periods compared with period 1 (P<0.05, all comparisons), but differences still existed in period 5. Risk-adjusted in-hospital mortality was higher after CABG for non-ST-segment-elevation myocardial infarction and after percutaneous coronary intervention and CABG for ST-segment-elevation myocardial infarction in women than men. Conclusions Despite variable trends in sex disparities in diagnostic and revascularization procedures for acute myocardial infarction, disparities still exist.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Feminino , Humanos , Masculino , Ponte de Artéria Coronária , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo , Resultado do Tratamento , Fatores Sexuais , Doença Aguda
20.
J Vasc Interv Radiol ; 34(3): 428-435, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36442743

RESUMO

PURPOSE: To evaluate the effectiveness and safety of atherectomy versus plain balloon angioplasty (POBA) for treatment of critical limb ischemia (CLI) due to tibioperoneal arterial disease (TPAD). MATERIALS AND METHODS: Patients enrolled in the Vascular Quality Initiative registry who had CLI (Rutherford Class 4-6) and underwent atherectomy versus POBA alone for isolated TPAD were retrospectively identified. Of eligible patients, a cohort of 2,908 patients was propensity matched 1:1 by clinical and angiographic characteristics. The atherectomy group comprised 1,454 patients with 2,183 arteries treated, and the POBA group comprised 1,454 patients with 2,141 arteries treated. The primary study endpoint was major ipsilateral limb amputation. Secondary endpoints were minor ipsilateral amputations, any ipsilateral amputation, primary patency, target vessel reintervention (TVR), and wound healing at 12 months. RESULTS: The median follow-up period was 507 days, the mean patient age was 69 years ± 11.7, and the mean occluded length was 6.9 cm ± 6.5. There was a trend toward higher technical success rates with atherectomy than with POBA (92.9% vs 91.0%, respectively; P = .06). The rates of major adverse events during the procedure were not significantly different. The 12-month major amputation rate was similar in the atherectomy and POBA groups (4.5% vs 4.6%, respectively; P = .92; odds ratio, 0.97; 95% CI, 0.68-1.37). There was no difference in 12-month TVR (17.9% vs 17.8%; P = .97) or primary patency (56.4% vs 54.5%; P = .64) between the atherectomy and POBA groups. CONCLUSIONS: In a large national registry, treatment of CLI from TPAD using atherectomy versus POBA showed no significant differences in procedural adverse events, major amputations, TVR, or vessel patency at 12 months.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Idoso , Estudos Retrospectivos , Salvamento de Membro , Isquemia , Fatores de Risco , Doença Arterial Periférica/terapia , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Aterectomia/efeitos adversos , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA