Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Invasive Cardiol ; 29(3): 105-108, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28208118

RESUMO

BACKGROUND: Multiple studies have demonstrated the relationship between contrast volume (CV) and the risk of acute kidney injury (AKI). Quantification of total CV is often estimated and therefore may be inaccurate. We describe validation of a novel contrast monitoring system (CMS) (Osprey Medical), which is designed to detect and display injection by injection and total CV use on a monitor system in real time. METHODS: Thirty patients undergoing a coronary or peripheral angiogram were included. Ten patients underwent procedures using the CMS only and 20 underwent procedures using both the CMS and the AVERT Plus contrast modulation system (Osprey Medical). Total CV used during these cases was measured using direct measurement via a graduated cylinder (CVDM). This was compared with the CMS-reported CV and with the operator's assessment of CV (CVPE) used during the case. Intraclass correlation coefficient (ICC) and Pearson correlation coefficient (PCC) were used for analysis and the results displayed using Bland-Altman plots. RESULTS: Twenty-one cases were diagnostic and 9 were interventional. The ICC/PCC (confidence interval [CI]) for the comparison of CVDM to CMS and CVPE were 0.96/0.97 [CI, 0.94-0.99] and 0.89/0.90 [CI, 0.80-0.95], respectively, with a P=.01 for difference between the correlations. The average absolute difference between the CVDM and CMS readout and the CVPE was 12.0 ± 13.7 mL and 22.8 ± 15.3 mL, respectively; P=.01. CONCLUSIONS: The CMS was accurate when compared with the direct measurement of CV used. This accuracy was superior to physician estimation of CV.


Assuntos
Injúria Renal Aguda , Angiografia , Meios de Contraste , Sistemas de Liberação de Medicamentos/métodos , Monitoramento de Medicamentos , Doenças Vasculares/diagnóstico , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/prevenção & controle , Idoso , Angiografia/efeitos adversos , Angiografia/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Precisão da Medição Dimensional , Relação Dose-Resposta a Droga , Esquema de Medicação , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/normas , Reprodutibilidade dos Testes , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA