Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 392
Filtrar
1.
J Prev Alzheimers Dis ; 11(1): 38-47, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38230715

RESUMO

BACKGROUND: Longitudinal changes in volumetric MRI outcome measures have been shown to correlate well with longitudinal changes in clinical instruments and have been widely used as biomarker outcomes in clinical trials for Alzheimer's disease (AD). While instances of discordant findings have been noted in some trials, especially the recent amyloid-removing therapies, the overall relationship between treatment effects on brain atrophy and clinical outcomes, and how it might depend on treatment target or mechanism, clinical instrument or imaging variable is not yet clear. OBJECTIVE: To systematically assess the consistency and therapeutic class-dependence of treatment effects on clinical outcomes and on brain atrophy in published reports of clinical trials conducted in mild cognitive impairment (MCI) and/or AD. DESIGN: Quantitative review of the published literature. The consistency of treatment effects on clinical and brain atrophy outcomes was assessed in terms of statistical agreement with hypothesized equal magnitude effects (e.g., 30% slowing of both) and nominal directional concordance, as a function of therapeutic class. SETTING: Interventional randomized clinical trials. PARTICIPANTS: MCI or AD trial participants. INTERVENTION: Treatments included were those that involved ingestion or injection of a putatively active substance into the body, encompassing both pharmacological and controlled dietary interventions. MEASUREMENTS: Each trial included in the analysis reported at least one of the required clinical outcomes (ADAS-Cog, CDR-SB or MMSE) and at least one of the required imaging outcomes (whole brain, ventricular or hippocampal volume). RESULTS: Data from 35 trials, comprising 185 pairwise comparisons, were included. Overall, the 95% confidence bounds overlapped with the line of identity for 150/185 (81%) of the imaging-clinical variable pairs. The greatest proportion of outliers was found in trials of anti-amyloid antibodies that have been shown to dramatically reduce the level of PET-detectable amyloid plaques, for which only 13/33 (39%) of observations overlapped the identity line. A Deming regression calculated using all data points yielded a slope of 0.54, whereas if data points from the amyloid remover class were excluded, the Deming regression line had a slope of 0.92. Directional discordance of treatment effects was also most pronounced for the amyloid-removing class, and for comparisons involving ventricular volume. CONCLUSION: Our results provide a frame of reference for the interpretation of clinical and brain atrophy results from future clinical trials and highlight the importance of mechanism of action in the interpretation of imaging results.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/patologia , Disfunção Cognitiva/patologia , Encéfalo , Hipocampo/patologia , Atrofia/patologia
2.
J Neurol ; 271(1): 355-373, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37716917

RESUMO

BACKGROUND: Multiple sclerosis (MS) is characterized by pathology in white matter (WM) and atrophy of grey matter (GM), but it remains unclear how these processes are related, or how they influence clinical progression. OBJECTIVE: To study the spatial and temporal relationship between GM atrophy and damage in connected WM in relapsing-remitting (RR) MS in relation to clinical progression. METHODS: Healthy control (HC) and early RRMS subjects visited our center twice with a 1-year interval for MRI and clinical examinations, including the Expanded Disability Status Scale (EDSS) and Multiple Sclerosis Functional Composite (MSFC) scores. RRMS subjects were categorized as MSFC decliners or non-decliners based on ΔMSFC over time. Ten deep (D)GM and 62 cortical (C) GM structures were segmented and probabilistic tractography was performed to identify the connected WM. WM integrity was determined per tract with, amongst others, fractional anisotropy (FA), mean diffusivity (MD), neurite density index (NDI), and myelin water fraction (MWF). Linear mixed models (LMMs) were used to investigate GM and WM differences between HC and RRMS, and between MSFC decliners and non-decliners. LMM was also used to test associations between baseline WM z-scores and changes in connected GM z-scores, and between baseline GM z-scores and changes in connected WM z-scores, in HC/RRMS subjects and in MSFC decliners/non-decliners. RESULTS: We included 13 HCs and 31 RRMS subjects with an average disease duration of 3.5 years and a median EDSS of 3.0. Fifteen RRMS subjects showed declining MSFC scores over time, and they showed higher atrophy rates and greater WM integrity loss compared to non-decliners. Lower baseline WM integrity was associated with increased CGM atrophy over time in RRMS, but not in HC subjects. This effect was only seen in MSFC decliners, especially when an extended WM z-score was used, which included FA, MD, NDI and MWF. Baseline GM measures were not significantly related to WM integrity changes over time in any of the groups. DISCUSSION: Lower baseline WM integrity was related to more cortical atrophy in RRMS subjects that showed clinical progression over a 1-year follow-up, while baseline GM did not affect WM integrity changes over time. WM damage, therefore, seems to drive atrophy more than conversely.


Assuntos
Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Substância Branca , Humanos , Esclerose Múltipla/complicações , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Progressão da Doença , Imageamento por Ressonância Magnética , Esclerose Múltipla Recidivante-Remitente/complicações , Atrofia/patologia
3.
J Neurol ; 270(11): 5201-5210, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37466663

RESUMO

BACKGROUND AND OBJECTIVES: Disability and cognitive impairment are known to be related to brain atrophy in multiple sclerosis (MS), but 3D-T1 imaging required for brain volumetrics is often unavailable in clinical protocols, unlike 3D-FLAIR. Here our aim was to investigate whether brain volumes derived from 3D-FLAIR images result in similar associations with disability and cognition in MS as do those derived from 3D-T1 images. METHODS: 3T-MRI scans of 329 MS patients and 76 healthy controls were included in this cross-sectional study. Brain volumes were derived using FreeSurfer on 3D-T1 and compared with brain volumes derived with SynthSeg and SAMSEG on 3D-FLAIR. Relative agreement was evaluated by calculating the intraclass correlation coefficient (ICC) of the 3D-T1 and 3D-FLAIR volumes. Consistency of relations with disability and average cognition was assessed using linear regression, while correcting for age and sex. The findings were corroborated in an independent validation cohort of 125 MS patients. RESULTS: The ICC between volume measured with FreeSurfer and those measured on 3D-FLAIR for brain, ventricle, cortex, total deep gray matter and thalamus was above 0.74 for SAMSEG and above 0.91 for SynthSeg. Worse disability and lower average cognition were similarly associated with brain (adj. R2 = 0.24-0.27, p < 0.01; adj. R2 = 0.26-0.29, p < 0.001) ventricle (adj. R2 = 0.27-0.28, p < 0.001; adj. R2 = 0.19-0.20, p < 0.001) and deep gray matter volumes (adj. R2 = 0.24-0.28, p < 0.001; adj. R2 = 0.27-0.28, p < 0.001) determined with all methods, except for cortical volumes derived from 3D-FLAIR. DISCUSSION: In this cross-sectional study, brain volumes derived from 3D-FLAIR and 3D-T1 show similar relationships to disability and cognitive dysfunction in MS, highlighting the potential of these techniques in clinical datasets.


Assuntos
Esclerose Múltipla , Humanos , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Substância Cinzenta/patologia , Estudos Transversais , Estudos de Viabilidade , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Cognição , Atrofia/patologia
4.
Mult Scler Relat Disord ; 74: 104706, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37068370

RESUMO

BACKGROUND: It is not known if and when first-line disease modifying therapy (DMT) can safely be discontinued in relapse onset multiple sclerosis (MS) patients. OBJECTIVES: To investigate the characteristics of patients who discontinued first-line DMT, and the occurrence of clinical and radiological inflammatory disease activity after discontinuation. METHODS: We collected clinical and MRI parameters from patients with relapse onset MS in the MS Center Amsterdam and Rijnstate Hospital Arnhem who discontinued first-line DMT with no intention of restarting or switching treatment. RESULTS: In total, 130 patients were included in the analyses. After discontinuation, 78 patients (60%) experienced disease activity. Sixty-three patients (48.5%) showed MRI activity after DMT discontinuation, 40 patients (30.8%) experienced relapse(s), and 29 patients (22.3%) restarted DMT. Higher age at DMT discontinuation was associated with a lower risk of MRI activity (45 -55 vs. <45 years: OR 0.301, p = 0.007, >55 vs. <45 years, OR: 0.296, p = 0.044), and with a lower risk of relapse(s) after discontinuation (45-55 vs. <45 years: OR=0.495, p = 0.106, >55 vs. <45 years: OR=0.081, p = 0.020). CONCLUSION: Higher age at first-line DMT discontinuation is associated with lower risk and severity of radiological disease activity in MS, and a lower risk of relapse(s) after discontinuation.


Assuntos
Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Humanos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/tratamento farmacológico , Progressão da Doença , Doença Crônica , Imageamento por Ressonância Magnética , Recidiva , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Estudos Retrospectivos
5.
J Prev Alzheimers Dis ; 10(2): 171-177, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36946443

RESUMO

OBJECTIVES: Efficacy and safety results from the EMERGE (NCT02484547) and ENGAGE (NCT02477800) phase 3 studies of aducanumab in early Alzheimer's disease (AD) have been published. In EMERGE, but not in ENGAGE, high-dose aducanumab demonstrated significant treatment effects across primary and secondary endpoints. Low-dose aducanumab results were consistent across studies with non-significant differences versus placebo that were intermediate to the high-dose arm in EMERGE. The present investigation examined data from EMERGE and ENGAGE through post-hoc analyses to determine factors that contributed to discordant results between the high-dose arms of the two studies. DESIGN: EMERGE and ENGAGE were 2 phase 3, randomized, double-blind, placebo-controlled, parallel-group studies. SETTING: EMERGE and ENGAGE were 2 global multicenter studies involving 348 sites in 20 countries. PARTICIPANTS: Participants in EMERGE and ENGAGE were aged 50 to 85 years and had mild cognitive impairment or mild AD dementia with confirmed amyloid pathology. The randomized and dosed population (all randomized patients who received at least one dose of study treatment) included 1638 patients in EMERGE and 1647 in ENGAGE. INTERVENTION: In EMERGE and ENGAGE, participants were randomized to receive low- or high-dose aducanumab or placebo (1:1:1) once every 4 weeks. MEASUREMENTS: In this paper, 4 areas were investigated through post-hoc analyses to understand the discordance in the high-dose arms of the EMERGE and ENGAGE studies: baseline characteristics, amyloid-related imaging abnormalities, non-normality of the data, and dosing/exposure to aducanumab. RESULTS: Post-hoc analyses showed that outcomes in the ENGAGE high-dose group were affected by an imbalance in a small number of patients with extremely rapid progression and by lower exposure to the target dose of 10 mg/kg. These factors were confounded and present in early enrolled patients but were not present in later-enrolled patients who were randomized to the target dosing regimen of 10 mg/kg after titration. Neither baseline characteristics nor amyloid-related imaging abnormalities contributed to the difference in results between the high-dose arms. CONCLUSIONS: Results were consistent across studies in later enrolled patients in which the incidence of rapidly progressing patients was balanced across treatment arms.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/tratamento farmacológico , Anticorpos Monoclonais Humanizados/uso terapêutico
6.
J Neurol ; 270(4): 2271-2282, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36723685

RESUMO

OBJECTIVE: Evaluate the effect of subcutaneous interferon ß-1a (sc IFN ß-1a) versus placebo on the evolution of T1-weighted MRI lesions and central brain atrophy in in patients with a first clinical demyelinating event (FCDE). METHODS: Post hoc analysis of baseline-to-24 month MRI data from patients with an FCDE who received sc IFN ß-1a 44 µg once- (qw) or three-times-weekly (tiw), or placebo, in REFLEX. Patients were grouped according to treatment regimen or conversion to clinically definite MS (CDMS) status. The intensity of new lesions on unenhanced T1-weighted images was classified as T1 iso- or hypo-intense (black holes) and percentage ventricular volume change (PVVC) was assessed throughout the study. RESULTS: In patients not converting to CDMS, sc IFN ß-1a tiw or qw, versus placebo, reduced the overall number of new lesions (P < 0.001 and P = 0.005) and new T1 iso-intense lesions (P < 0.001 and P = 0.002) after 24 months; only sc IFN ß-1a tiw was associated with fewer T1 hypo-intense lesions versus placebo (P < 0.001). PVVC findings in patients treated with sc IFN ß-1a suggested pseudo-atrophy that was ~ fivefold greater versus placebo in the first year of treatment (placebo 1.11%; qw 4.28%; tiw 6.76%; P < 001); similar findings were apparent for non-converting patients. CONCLUSIONS: In patients with an FCDE, treatment with sc IFN ß-1a tiw for 24 months reduced the number of new lesions evolving into black holes.


Assuntos
Imageamento por Ressonância Magnética , Esclerose Múltipla Recidivante-Remitente , Humanos , Adjuvantes Imunológicos/efeitos adversos , Atrofia/tratamento farmacológico , Atrofia/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Interferon beta-1a/uso terapêutico , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Esclerose Múltipla Recidivante-Remitente/induzido quimicamente , Resultado do Tratamento
8.
AJNR Am J Neuroradiol ; 43(9): E19-E35, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35953274

RESUMO

Monoclonal antibodies are emerging disease-modifying therapies for Alzheimer disease that require brain MR imaging for eligibility assessment as well as for monitoring for amyloid-related imaging abnormalities. Amyloid-related imaging abnormalities result from treatment-related loss of vascular integrity and may occur in 2 forms. Amyloid-related imaging abnormalities with edema or effusion are transient, treatment-induced edema or sulcal effusion, identified on T2-FLAIR. Amyloid-related imaging abnormalities with hemorrhage are treatment-induced microhemorrhages or superficial siderosis identified on T2* gradient recalled-echo. As monoclonal antibodies become more widely available, treatment screening and monitoring brain MR imaging examinations may greatly increase neuroradiology practice volumes. Radiologists must become familiar with the imaging appearance of amyloid-related imaging abnormalities, how to select an appropriate imaging protocol, and report findings in clinical practice. On the basis of clinical trial literature and expert experience from clinical trial imaging, we summarize imaging findings of amyloid-related imaging abnormalities, describe potential interpretation pitfalls, and provide recommendations for a standardized imaging protocol and an amyloid-related imaging abnormalities reporting template. Standardized imaging and reporting of these findings are important because an amyloid-related imaging abnormalities severity score, derived from the imaging findings, is used along with clinical status to determine patient management and eligibility for continued monoclonal antibody dosing.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/diagnóstico por imagem , Encéfalo , Amiloide , Imageamento por Ressonância Magnética/métodos , Anticorpos Monoclonais/uso terapêutico
9.
J Prev Alzheimers Dis ; 9(2): 197-210, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35542991

RESUMO

BACKGROUND: Alzheimer's disease is a progressive, irreversible, and fatal disease for which accumulation of amyloid beta is thought to play a key role in pathogenesis. Aducanumab is a human monoclonal antibody directed against aggregated soluble and insoluble forms of amyloid beta. OBJECTIVES: We evaluated the efficacy and safety of aducanumab in early Alzheimer's disease. DESIGN: EMERGE and ENGAGE were two randomized, double-blind, placebo-controlled, global, phase 3 studies of aducanumab in patients with early Alzheimer's disease. SETTING: These studies involved 348 sites in 20 countries. PARTICIPANTS: Participants included 1638 (EMERGE) and 1647 (ENGAGE) patients (aged 50-85 years, confirmed amyloid pathology) who met clinical criteria for mild cognitive impairment due to Alzheimer's disease or mild Alzheimer's disease dementia, of which 1812 (55.2%) completed the study. INTERVENTION: Participants were randomly assigned 1:1:1 to receive aducanumab low dose (3 or 6 mg/kg target dose), high dose (10 mg/kg target dose), or placebo via IV infusion once every 4 weeks over 76 weeks. MEASUREMENTS: The primary outcome measure was change from baseline to week 78 on the Clinical Dementia Rating Sum of Boxes (CDR-SB), an integrated scale that assesses both function and cognition. Other measures included safety assessments; secondary and tertiary clinical outcomes that assessed cognition, function, and behavior; and biomarker endpoints. RESULTS: EMERGE and ENGAGE were halted based on futility analysis of data pooled from the first approximately 50% of enrolled patients; subsequent efficacy analyses included data from a larger data set collected up to futility declaration and followed prespecified statistical analyses. The primary endpoint was met in EMERGE (difference of -0.39 for high-dose aducanumab vs placebo [95% CI, -0.69 to -0.09; P=.012; 22% decrease]) but not in ENGAGE (difference of 0.03, [95% CI, -0.26 to 0.33; P=.833; 2% increase]). Results of biomarker substudies confirmed target engagement and dose-dependent reduction in markers of Alzheimer's disease pathophysiology. The most common adverse event was amyloid-related imaging abnormalities-edema. CONCLUSIONS: Data from EMERGE demonstrated a statistically significant change across all four primary and secondary clinical endpoints. ENGAGE did not meet its primary or secondary endpoints. A dose- and time-dependent reduction in pathophysiological markers of Alzheimer's disease was observed in both trials.


Assuntos
Doença de Alzheimer , Doença de Alzheimer/tratamento farmacológico , Peptídeos beta-Amiloides , Anticorpos Monoclonais Humanizados/uso terapêutico , Biomarcadores , Humanos
10.
Med Phys ; 49(5): 3298-3313, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35271742

RESUMO

PURPOSE: A novel phantom-imaging platform, a set of software tools, for automated and high-precision imaging of the American College of Radiology (ACR) positron emission tomography (PET) phantom for PET/magnetic resonance (PET/MR) and PET/computed tomography (PET/CT) systems is proposed. METHODS: The key feature of this platform is the vector graphics design that facilitates the automated measurement of the knife-edge response function and hence image resolution, using composite volume of interest templates in a 0.5 mm resolution grid applied to all inserts of the phantom. Furthermore, the proposed platform enables the generation of an accurate µ $\mu$ -map for PET/MR systems with a robust alignment based on two-stage image registration using specifically designed PET templates. The proposed platform is based on the open-source NiftyPET software package used to generate multiple list-mode data bootstrap realizations and image reconstructions to determine the precision of the two-stage registration and any image-derived statistics. For all the analyses, iterative image reconstruction was employed with and without modeled shift-invariant point spread function and with varying iterations of the ordered subsets expectation maximization (OSEM) algorithm. The impact of the activity outside the field of view (FOV) was assessed using two acquisitions of 30 min each, with and without the activity outside the FOV. RESULTS: The utility of the platform has been demonstrated by providing a standard and an advanced phantom analysis including the estimation of spatial resolution using all cylindrical inserts. In the imaging planes close to the edge of the axial FOV, we observed deterioration in the quantitative accuracy, reduced resolution (FWHM increased by 1-2 mm), reduced contrast, and background uniformity due to the activity outside the FOV. Although it slows convergence, the PSF reconstruction had a positive impact on resolution and contrast recovery, but the degree of improvement depended on the regions. The uncertainty analysis based on bootstrap resampling of raw PET data indicated high precision of the two-stage registration. CONCLUSIONS: We demonstrated that phantom imaging using the proposed methodology with the metric of spatial resolution and multiple bootstrap realizations may be helpful in more accurate evaluation of PET systems as well as in facilitating fine tuning for optimal imaging parameters in PET/MR and PET/CT clinical research studies.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA