Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Blood ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713888

RESUMO

Mass spectrometry (MS) can detect multiple myeloma-derived monoclonal proteins in peripheral blood (PB) with high sensitivity, potentially serving as a PB assay for measurable residual disease (MRD). This study evaluated the significance of PB MS MRD negativity during post-transplant therapy in patients with newly diagnosed multiple myeloma. Serum samples from 138 patients treated in the phase 3 ATLAS trial of post-transplant maintenance with either carfilzomib, lenalidomide, dexamethasone or lenalidomide alone were analyzed using EXENT MS methodology. We established feasibility of measuring MRD by MS in PB in the post-transplant setting, despite unavailability of pre-treatment calibration samples. There was high agreement between MRD by MS in PB and paired BM MRD results at the 10-5 threshold, assessed by either next generation sequencing (NGS) or multiparameter flow cytometry (MFC) (70% and 67%, respectively). Agreement between PB MS and both BM MRD methods was lowest early after transplant and increased with time. MS negativity was associated with improved progression-free survival (PFS), which in landmark analysis reached statistical significance after 18 cycles post-transplant. Combined PB/BM MRD negativity by MFC or NGS was associated with superior PFS compared to MRD negativity by only one modality. Sustained MS negativity carried similar prognostic performance to sustained BM MRD negativity at the 10-5 threshold. Overall, post-transplant MS assessment was feasible and provided additional prognostic information to BM MRD negativity. Further studies are needed to confirm the role and optimal timing of MS in disease evaluation algorithms. The ATLAS trial is registered at www.clinicaltrials.gov as #NCT02659293.

2.
J Mass Spectrom Adv Clin Lab ; 28: 133-141, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37138663

RESUMO

Introduction: Clonal plasma cells secrete immunoglobulins, each with the exact same amino acid sequence, that are referred to as monoclonal immunoglobulins. The monoclonal heavy chain and light chain secreted from clonal plasma cells have the same molecular mass prior to the addition of post-translational modifications (PTMs) since their amino acid sequences are the same. Objective: To examine the molecular masses of monoclonal light chains and heavy chains isolated directly from the cytoplasm of bone marrow (BM) plasma cells and compare them to the serum derived monoclonal heavy and light chains. Methods: Using immunopurification and LC-MS we compared the molecular masses of immunoglobulins immunopurified from a patient's serum to those immunopurified from the cytoplasm of their BM plasma cells. Results: Our findings demonstrate that the light chain molecular masses were identical whether they were obtained from serum or plasma cell cytoplasm. However, the heavy chain molecular masses did not match in bone marrow and serum due to differences in glycosylation, a common post-translational modification (PTM) found on the heavy chain. Conclusion: The data presented here show that by using LC-MS to analyze monoclonal immunoglobulins (also referred to as miRAMM) additional phenotype information is obtained at the cellular level which is complementary to other more common techniques such as flow cytometry and histopathology.

3.
Anal Chem ; 91(5): 3263-3269, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30801187

RESUMO

The current five-year survival rate for systemic AL amyloidosis or multiple myeloma is ∼51%, indicating the urgent need for better diagnosis methods and treatment plans. Here, we describe highly specific and sensitive top-down and middle-down MS/MS methods owning the advantages of fast sample preparation, ultrahigh mass accuracy, and extensive residue cleavages with 21 telsa FT-ICR MS/MS. Unlike genomic testing, which requires bone marrow aspiration and may fail to identify all monoclonal immunoglobulins produced by the body, the present method requires only a blood draw. In addition, circulating monoclonal immunoglobulins spanning the entire population are analyzed and reflect the selection of germline sequence by B cells. The monoclonal immunoglobulin light chain FR2-CDR2-FR3 was sequenced by database-aided de novo MS/MS and 100% matched the gene sequencing result, except for two amino acids with isomeric counterparts, enabling accurate germline sequence classification. The monoclonal immunoglobulin heavy chains were also classified into specific germline sequences based on the present method. This work represents the first application of top/middle-down MS/MS sequencing of endogenous human monoclonal immunoglobulins with polyclonal immunoglobulins background.


Assuntos
Amiloidose/classificação , Cadeias Leves de Imunoglobulina/sangue , Mieloma Múltiplo/classificação , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Amiloidose/diagnóstico , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/metabolismo , Cromatografia Líquida de Alta Pressão , Análise de Fourier , Humanos , Cadeias Leves de Imunoglobulina/química , Imunoglobulinas/isolamento & purificação , Imunoglobulinas/metabolismo , Mieloma Múltiplo/diagnóstico , Paraproteinemias/classificação , Paraproteinemias/diagnóstico
4.
Rheumatology (Oxford) ; 57(4): 639-650, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29340623

RESUMO

Objectives: To study the determinants of the pharmacokinetics (PK) of rituximab (RTX) in patients with ANCA-associated vasculitis (AAV) and its association with clinical outcomes. Methods: This study included data from 89 patients from the RTX in AAV trial who received the full dose of RTX (four weekly infusions of 375 mg/m2). RTX was quantified at weeks 2, 4, 8, 16 and 24, and summarized by computing the trapezoidal area under the curve. We explored potential determinants of the PK-RTX, and analysed its association with clinical outcomes: achievement of remission at 6 months, duration of B-cell depletion and time to relapse in patients who achieved complete remission. Results: RTX serum levels were significantly lower in males and in newly diagnosed patients, and negatively correlated with body surface area, baseline B-cell count and degree of disease activity. In multivariate analyses, the main determinants of PK-RTX were sex and new diagnosis. Patients reaching complete remission at month 6 had similar RTX levels compared with patients who did not reach complete remission. Patients with higher RTX levels generally experienced longer B-cell depletion than patients with lower levels, but RTX levels at the different time points and area under the curve were not associated with time to relapse. Conclusion: Despite the body-surface-area-based dosing protocol, PK-RTX is highly variable among patients with AAV, its main determinants being sex and newly diagnosed disease. We did not observe any relevant association between PK-RTX and clinical outcomes. The monitoring of serum RTX levels does not seem clinically useful in AAV.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/tratamento farmacológico , Rituximab/farmacocinética , Adulto , Idoso , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/sangue , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/imunologia , Linfócitos B/imunologia , Linfócitos B/patologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Fatores Imunológicos/administração & dosagem , Fatores Imunológicos/farmacocinética , Infusões Intravenosas , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Indução de Remissão , Rituximab/administração & dosagem , Resultado do Tratamento
5.
Am J Hematol ; 92(8): 772-779, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28439985

RESUMO

The detection and quantification of monoclonal-proteins (M-proteins) are necessary for the diagnosis and evaluation of response in plasma cell dyscrasias. Immunoglobulin enrichment-coupled with matrix-assisted laser desorption ionization time-of-flight mass-spectrometry (MASS-FIX) is a simple and inexpensive method to identify M-proteins, but its clinical generalizability has not yet been elucidated. We compared MASS-FIX to protein electrophoresis (PEL), serum/urine immunofixation-electrophoresis (IFE), and quantitative serum free-light chain (FLC) for the identification of M-proteins in different clinical diagnoses. Paired serum and urine samples from 257 patients were tested. There were six patients for whom s-IFE and FLC ratio were positive and serum MASS-FIX was negative, but when serum and urine MASS-FIX results were combined, only one patient with light chain-MGUS was missed. Serum/urine-MASS-FIX detected M-proteins in 18 patients with negative serum/urine-PEL/IFE and serum-FLC, 10 of whom had multiple myeloma or AL amyloidosis, who were mistakenly thought to have complete hematologic response by serum/urine-PEL/IFE and serum-FLC. Nearly half of the AL amyloidosis patients had atypical spectra, which may prove to be a clue to the diagnosis and pathogenesis of the disease. In conclusion, MASS-FIX has a comparable sensitivity with PEL/IFE/FLC methods and can help inform the clinical diagnosis.


Assuntos
Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Proteínas do Mieloma , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Idoso , Biomarcadores , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
6.
Am J Hematol ; 92(6): 536-541, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28295502

RESUMO

Immunoglobulin light chain (AL) amyloidosis is a fatal complication of B-cell proliferation secondary to deposition of amyloid fibrils in various organs. Urinary exosomes (UEX) are the smallest of the microvesicles excreted in the urine. Previously, we found UEX of patients with AL amyloidosis contained immunoglobulin light chain (LC) oligomers that patients with multiple myeloma did not have. To further explore the role of the LC oligomers, UEX was isolated from an AL amyloidosis patient with progressive renal disease despite achieving a complete response. LC oligomers were identified. Mass spectrometry (MS) of the UEX and serum identified two monoclonal lambda LCs. Proteomics of the trypsin digested amyloid fragments in the kidney by laser microdissection and MS analysis identified a λ6 LC. The cDNA from plasma cell clone was from the IGLV- 6-57 family and it matched the amino acid sequences of the amyloid peptides. The predicted mass of the peptide product of the cDNA matched the mass of one of the two LCs identified in the UEX and serum. UEX combined with MS were able to identify 2 monoclonal lambda LCs that current clinical methods could not. It also identified the amyloidogenic LC which holds potential for response assessment in the future.


Assuntos
Amiloidose/complicações , Amiloidose/metabolismo , Exossomos/metabolismo , Cadeias Leves de Imunoglobulina/metabolismo , Proteinúria/diagnóstico , Proteinúria/etiologia , Adulto , Idoso , Sequência de Aminoácidos , Amiloidose/genética , Feminino , Humanos , Cadeias Leves de Imunoglobulina/química , Cadeias Leves de Imunoglobulina/genética , Cadeias Leves de Imunoglobulina/urina , Amiloidose de Cadeia Leve de Imunoglobulina , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Peso Molecular , Agregados Proteicos , Agregação Patológica de Proteínas/metabolismo , Agregação Patológica de Proteínas/urina , Análise de Sequência de DNA
8.
Clin Vaccine Immunol ; 24(5)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28274937

RESUMO

Therapeutic monoclonal antibodies (MAbs) are an important class of drugs used to treat diseases ranging from autoimmune disorders to B cell lymphomas to other rare conditions thought to be untreatable in the past. Many advances have been made in the characterization of immunoglobulins as a result of pharmaceutical companies investing in technologies that allow them to better understand MAbs during the development phase. Mass spectrometry is one of the new advancements utilized extensively by pharma to analyze MAbs and is now beginning to be applied in the clinical laboratory setting. The rise in the use of therapeutic MAbs has opened up new challenges for the development of assays for monitoring this class of drugs. MAbs are larger and more complex than typical small-molecule therapeutic drugs routinely analyzed by mass spectrometry. In addition, they must be quantified in samples that contain endogenous immunoglobulins with nearly identical structures. In contrast to an enzyme-linked immunosorbent assay (ELISA) for quantifying MAbs, mass spectrometry-based assays do not rely on MAb-specific reagents such as recombinant antigens and/or anti-idiotypic antibodies, and time for development is usually shorter. Furthermore, using molecular mass as a measurement tool provides increased specificity since it is a first-order principle unique to each MAb. This enables rapid quantification of MAbs and multiplexing. This review describes how mass spectrometry can become an important tool for clinical chemists and especially immunologists, who are starting to develop assays for MAbs in the clinical laboratory and are considering mass spectrometry as a versatile platform for the task.


Assuntos
Anticorpos Monoclonais/análise , Espectrometria de Massas/métodos , Humanos
9.
J Am Soc Mass Spectrom ; 28(5): 827-838, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28247297

RESUMO

With the rapid growth of therapeutic monoclonal antibodies (mAbs), stringent quality control is needed to ensure clinical safety and efficacy. Monoclonal antibody primary sequence and post-translational modifications (PTM) are conventionally analyzed with labor-intensive, bottom-up tandem mass spectrometry (MS/MS), which is limited by incomplete peptide sequence coverage and introduction of artifacts during the lengthy analysis procedure. Here, we describe top-down and middle-down approaches with the advantages of fast sample preparation with minimal artifacts, ultrahigh mass accuracy, and extensive residue cleavages by use of 21 tesla FT-ICR MS/MS. The ultrahigh mass accuracy yields an RMS error of 0.2-0.4 ppm for antibody light chain, heavy chain, heavy chain Fc/2, and Fd subunits. The corresponding sequence coverages are 81%, 38%, 72%, and 65% with MS/MS RMS error ~4 ppm. Extension to a monoclonal antibody in human serum as a monoclonal gammopathy model yielded 53% sequence coverage from two nano-LC MS/MS runs. A blind analysis of five therapeutic monoclonal antibodies at clinically relevant concentrations in human serum resulted in correct identification of all five antibodies. Nano-LC 21 T FT-ICR MS/MS provides nonpareil mass resolution, mass accuracy, and sequence coverage for mAbs, and sets a benchmark for MS/MS analysis of multiple mAbs in serum. This is the first time that extensive cleavages for both variable and constant regions have been achieved for mAbs in a human serum background. Graphical Abstract ᅟ.


Assuntos
Adalimumab/sangue , Anticorpos Monoclonais/sangue , Paraproteinemias/sangue , Espectrometria de Massas em Tandem/métodos , Adalimumab/análise , Sequência de Aminoácidos , Anticorpos Monoclonais/análise , Análise de Fourier , Humanos , Processamento de Proteína Pós-Traducional , Software , Espectrometria de Massas por Ionização por Electrospray/métodos
10.
J Am Soc Mass Spectrom ; 28(5): 811-817, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28004336

RESUMO

As therapeutic monoclonal antibodies (mAbs) become more humanized, traditional tryptic peptide approaches used to measure biologics in serum become more challenging since unique clonotypic peptides used for quantifying the mAb may also be found in the normal serum polyclonal background. An alternative approach is to monitor the unique molecular mass of the intact light chain portion of the mAbs using liquid chromatography-mass spectrometry (LC-MS). Distinguishing a therapeutic mAb from a patient's normal polyclonal immunoglobulin (Ig) repertoire is the primary limiting factor when determining the limit of quantitation (LOQ) in serum. The ability to selectively extract subclass specific Igs from serum reduces the polyclonal background in a sample. We present here the development of an LC-MS method to quantify eculizumab in serum. Eculizumab is a complement component 5 (C5) binding mAb that is fully humanized and contains portions of both IgG2 and IgG4 subclasses. Our group developed a method that uses Life Technologies CaptureSelect IgG4 (Hu) affinity matrix. We show here the ability to quantitate eculizumab with a LOQ of 5 mcg/mL by removing the higher abundance IgG1, IgG2, and IgG3 from the polyclonal background, making this approach a simple and efficient procedure. Graphical Abstract ᅟ.


Assuntos
Anticorpos Monoclonais Humanizados/sangue , Cromatografia de Afinidade/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Anticorpos Monoclonais Humanizados/análise , Anticorpos Monoclonais Humanizados/isolamento & purificação , Humanos , Imunoglobulina G/isolamento & purificação , Limite de Detecção , Reprodutibilidade dos Testes
11.
Clin Chem ; 62(10): 1334-44, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27540026

RESUMO

BACKGROUND: Electrophoretic separation of serum and urine proteins has played a central role in diagnosing and monitoring plasma cell disorders. Despite limitations in resolution and analytical sensitivity, plus the necessity for adjunct methods, protein gel electrophoresis and immunofixation electrophoresis (IFE) remain front-line tests. METHODS: We developed a MALDI mass spectrometry-based assay that was simple to perform, automatable, analytically sensitive, and applicable to analyzing the wide variety of monoclonal proteins (M-proteins) encountered clinically. This assay, called MASS-FIX, used the unique molecular mass signatures of the different Ig isotypes in combination with nanobody immunoenrichment to generate information-rich mass spectra from which M-proteins could be identified, isotyped, and quantified. The performance of MASS-FIX was compared to current gel-based electrophoresis assays. RESULTS: MASS-FIX detected all M-proteins that were detectable by urine or serum protein electrophoresis. In serial dilution studies, MASS-FIX was more analytically sensitive than IFE. For patient samples, MASS-FIX provided the same primary isotype information for 98% of serum M-proteins (n = 152) and 95% of urine M-proteins (n = 55). MASS-FIX accurately quantified M-protein to <1 g/dL, with reduced bias as compared to protein electrophoresis. Intraassay and interassay CVs were <20% across all samples having M-protein concentrations >0.045 g/dL, with the ability to detect M-proteins <0.01 g/dL. In addition, MASS-FIX could simultaneously measure κ:λ light chain ratios for IgG, IgA, and IgM. Retrospective serial monitoring of patients with myeloma posttreatment demonstrated that MASS-FIX provided equivalent quantitative information to either protein electrophoresis or the Hevylite(™) assay. CONCLUSIONS: MASS-FIX can advance how plasma cell disorders are screened, diagnosed, and monitored.


Assuntos
Anticorpos Monoclonais/sangue , Cadeias Leves de Imunoglobulina/sangue , Nanopartículas/análise , Anticorpos Monoclonais/imunologia , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Nanopartículas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
12.
Clin Chem ; 62(10): 1345-52, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27515443

RESUMO

BACKGROUND: Current recommendations for screening for monoclonal gammopathies include serum protein electrophoresis (PEL), imunofixation electrophoresis (IFE), and free light chain (FLC) ratios to identify or rule out an M-protein. The aim of this study was to examine the feasibility of an assay based on immunoenrichment and MALDI-TOF-MS (MASS-SCREEN) to qualitatively screen for M-proteins. METHODS: Serum from 556 patients previously screened for M-proteins by PEL and IFE were immunopurified using a κ/λ-specific nanobody bead mixture. Following purification, light chains (LC) were released from their heavy chains by reduction. MALDI-TOF analysis was performed and the mass-to-charge LC distributions were visually examined for the presence of an M-protein by both unblinded and blinded analysts. RESULTS: In unblinded analysis, MASS-SCREEN detected 100% of the PEL-positive samples with an analytical sensitivity and specificity of 96% and 81% using IFE positivity as the standard. In a blinded analysis using 6 different laboratory personnel, consensus was reached in 92% of the samples. Overall analytical sensitivity and specificity were reduced to 92% and 80%, respectively. FLC ratios were found to be abnormal in 28% of MASS-SCREEN-negative samples, suggesting FLC measurements need to be considered in screening. CONCLUSIONS: MASS-SCREEN could replace PEL in a panel that would include FLC measurements. Further studies and method development should be performed to validate the clinical sensitivity and specificity and to determine if this panel will suffice as a general screen for monoclonal proteins.


Assuntos
Anticorpos Monoclonais/sangue , Cadeias Leves de Imunoglobulina/sangue , Nanopartículas/química , Anticorpos Monoclonais/imunologia , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
13.
Anal Chem ; 88(12): 6317-25, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27228216

RESUMO

Therapeutic monoclonal immunoglobulins (mAbs) are used to treat patients with a wide range of disorders including autoimmune diseases. As pharmaceutical companies bring more fully humanized therapeutic mAb drugs to the healthcare market analytical platforms that perform therapeutic drug monitoring (TDM) without relying on mAb specific reagents will be needed. In this study we demonstrate that liquid-chromatography-mass spectrometry (LC-MS) can be used to perform TDM of mAbs in the same manner as smaller nonbiologic drugs. The assay uses commercially available reagents combined with heavy and light chain disulfide bond reduction followed by light chain analysis by microflow-LC-electrospray ionization-quadrupole-time-of-flight mass spectrometry (ESI-Q-TOF MS). Quantification is performed using the peak areas from multiply charged mAb light chain ions using an in-house developed software package developed for TDM of mAbs. The data presented here demonstrate the ability of an LC-MS assay to quantify a therapeutic mAb in a large cohort of patients in a clinical trial. The ability to quantify any mAb in serum via the reduced light chain without the need for reagents specific for each mAb demonstrates the unique capabilities of LC-MS. This fact, coupled with the ability to phenotype a patient's polyclonal repertoire in the same analysis further shows the potential of this approach to mAb analysis.


Assuntos
Ensaio de Imunoadsorção Enzimática , Rituximab/sangue , Algoritmos , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/tratamento farmacológico , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/metabolismo , Anticorpos/imunologia , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/imunologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Cromatografia Líquida de Alta Pressão , Humanos , Limite de Detecção , Fenótipo , Rituximab/imunologia , Rituximab/uso terapêutico , Espectrometria de Massas por Ionização por Electrospray
14.
Clin Chem Lab Med ; 54(6): 929-37, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27107835

RESUMO

Recently, monoclonal gammopathy of renal significance (MGRS) reclassified all monoclonal (M) gammopathies that are associated with the development of a kidney disease but do not meet the definition of symptomatic multiple myeloma (MM) or malignant lymphoma. The purpose was to distinguish the M gammopathy as the nephrotoxic agent independent from the clonal mass. The diagnosis of MGRS obviously depends on the detection of the M-protein. More importantly, the success of treatment is correlated with the reduction of the M-protein. Therefore, familiarity with the M-protein tests is a must. Protein electrophoresis performed in serum or urine is inexpensive and rapid due to automation. However, poor sensitivity especially with the urine is an issue particularly with the low-level M gammopathy often encountered with MGRS. Immunofixation adds to the sensitivity and specificity but also the cost. Serum free light chain (sFLC) assays have significantly increased the sensitivity of M-protein detection and is relatively inexpensive. It is important to recognize that there is more than one assay on the market and their results are not interchangeable. In addition, in certain diseases, immunofixation is more sensitive than sFLC. Finally, novel techniques with promising results are adding to the ability to identify M-proteins. Using the time of flight method, the use of mass spectrometry of serum samples has been shown to dramatically increase the sensitivity of M-protein detection. In another technique, oligomeric LCs are identified on urinary exosomes amplifying the specificity for the nephrotoxic M-protein.


Assuntos
Nefropatias/diagnóstico , Paraproteinemias/diagnóstico , Paraproteínas/urina , Eletroforese das Proteínas Sanguíneas , Humanos , Imunoensaio , Imunoeletroforese , Cadeias Leves de Imunoglobulina/sangue , Cadeias Leves de Imunoglobulina/urina , Nefropatias/sangue , Nefropatias/etiologia , Nefropatias/urina , Limite de Detecção , Proteínas do Mieloma/análise , Paraproteinemias/sangue , Paraproteinemias/complicações , Paraproteinemias/urina
15.
Clin Chem Lab Med ; 54(6): 1073-83, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26845720

RESUMO

BACKGROUND: Serum immunoglobulin free light chains (FLC) are secreted into circulation by plasma cells as a by-product of immunoglobulin production. In a healthy individual the population of FLC is polyclonal as no single cell is secreting more FLC than the total immunoglobulin secreting cell population. In a person with a plasma cell dyscrasia, such as multiple myeloma (MM) or light chain amyloidosis (AL), a clonal population of plasma cells secretes a monoclonal light chain at a concentration above the normal polyclonal background. METHODS: We recently showed that monoclonal immunoglobulin rapid accurate mass measurement (miRAMM) can be used to identify and quantify a monoclonal light chain (LC) in serum and urine above the polyclonal background. This was accomplished by reducing immunoglobulin disulfide bonds releasing the LC to be analyzed by microLC-ESI-Q-TOF mass spectrometry. Here we demonstrate that the methodology can also be applied to the detection and quantification of FLC by analyzing a non-reduced sample. RESULTS: Proof of concept experiments were performed using purified FLC spiked into normal serum to assess linearity and precision. In addition, a cohort of 27 patients with AL was analyzed and miRAMM was able to detect a monoclonal FLC in 23 of the 27 patients that had abnormal FLC values by immunonephelometry. CONCLUSIONS: The high resolution and high mass measurement accuracy provided by the mass spectrometry based methodology eliminates the need for κ/λ ratios as the method can quantitatively monitor the abundance of the κ and λ polyclonal background at the same time it measures the monoclonal FLC.


Assuntos
Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Adalimumab/sangue , Amiloidose/sangue , Amiloidose/imunologia , Humanos , Cadeias Pesadas de Imunoglobulinas/sangue , Cadeias kappa de Imunoglobulina/urina , Cadeias lambda de Imunoglobulina/urina , Espectrometria de Massas por Ionização por Electrospray
16.
Clin Chem Lab Med ; 54(6): 1085-93, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26812875

RESUMO

BACKGROUND: The use of therapeutic recombinant monoclonal antibodies (mAbs) has triggered concerns of mis-diagnosis of a plasma cell dyscrasia in treated patients. The purpose of this study is to determine if infliximab (INF), adalimumab (ADA), eculizumab (ECU), vedolizumab (VEDO), and rituximab (RITU) are detected as monoclonal proteins by serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). METHODS: Pooled normal sera were spiked with various concentrations (ranging from trough to peak) of INF, ADA, ECU, VEDO and RITU. The peak concentration for VEDO and RITU was also added to samples with known monoclonal gammopathies. All samples were analyzed by SPEP (Helena Laboratories) and IFE (Sebia); sera containing peak concentrations of mAbs were reflexed to electrospray-time-of-flight mass spectrometry (AbSciex Triple TOF 5600) for the intact light chain monoclonal immunoglobulin rapid accurate mass measurement (miRAMM). RESULTS: For all mAbs tested, no quantifiable M-spikes were observed by SPEP at any concentration analyzed. Small γ fraction abnormalities were noted on SPEP for VEDO at 300 µg/mL and RITU at 400 µg/mL, with identification of small IgG κ proteins on IFE. Using miRAMM for peak samples, therapeutic mAbs light chain accurate masses were identified above the polyclonal background and were distinct from endogenous monoclonal gammopathies. CONCLUSIONS: MAbs should not be easily confounded with plasma cell dyscrasias in patients undergoing therapy except when a SPEP and IFE are performed within a couple of days from infusion (peak). In ambiguous cases the use of the miRAMM technology could precisely identify the therapeutic mAb distinct from any endogenous monoclonal protein.


Assuntos
Anticorpos Monoclonais/sangue , Paraproteinemias/diagnóstico , Anticorpos Monoclonais/uso terapêutico , Eletroforese das Proteínas Sanguíneas , Erros de Diagnóstico/prevenção & controle , Humanos , Imunoeletroforese , Imunoglobulina G/sangue , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Inflamação/tratamento farmacológico
17.
Clin Chem ; 62(1): 48-69, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26719571

RESUMO

BACKGROUND: For many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope-labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays. CONTENT: The Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials-in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry-is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.


Assuntos
Técnicas de Laboratório Clínico , Espectrometria de Massas , Peptídeos/análise , Proteômica , Manejo de Espécimes , Guias como Assunto , Humanos , Peptídeos/isolamento & purificação , Pesquisadores
18.
Clin Chem ; 62(1): 243-51, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26430073

RESUMO

BACKGROUND: Analytically sensitive techniques for measuring minimal residual disease (MRD) in multiple myeloma (MM) currently require invasive and costly bone marrow aspiration. These methods include immunohistochemistry (IHC), flow cytometry, quantitative PCR, and next-generation sequencing. An ideal MM MRD test would be a serum-based test sensitive enough to detect low concentrations of Ig secreted from multifocal lesions. METHODS: Patient serum with abundant M-protein before treatment was separated on a 1-dimensional SDS-PAGE gel, and the Ig light-chain (LC) band was excised, trypsin digested, and analyzed on a Q Exactive mass spectrometer by LC-MS/MS. We used the peptide's abundance and sequence to identify tryptic peptides that mapped to complementary determining regions of Ig LCs. The clonotypic target tryptic peptides were used to monitor MRD in subsequent serum samples with prior affinity enrichment. RESULTS: Sixty-two patients were tested, 20 with no detectable disease by IHC and 42 with no detectable disease by 6-color flow cytometry. A target peptide that could be monitored was identified in 57 patients (91%). Of these 57, detectable disease by LC-MS/MS was found in 52 (91%). CONCLUSIONS: The ability to use LC-MS/MS to measure disease in patients who are negative by bone marrow-based methodologies indicates that a serum-based approach has more analytical sensitivity and may be useful for measuring deeper responses to MM treatment. The method requires no bone marrow aspiration.


Assuntos
Cadeias Leves de Imunoglobulina/sangue , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Neoplasia Residual/sangue , Neoplasia Residual/diagnóstico , Peptídeos/sangue , Medula Óssea/patologia , Exame de Medula Óssea , Regiões Determinantes de Complementaridade/sangue , Regiões Determinantes de Complementaridade/genética , Humanos , Cadeias Leves de Imunoglobulina/genética , Mieloma Múltiplo/patologia , Neoplasia Residual/patologia , Peptídeos/genética , RNA Mensageiro/sangue , RNA Mensageiro/genética , Sucção
19.
J Proteome Res ; 14(12): 5283-90, 2015 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-26598961

RESUMO

In our previous work, we showed that electrospray ionization of intact polyclonal kappa and lambda light chains isolated from normal serum generates two distinct, Gaussian-shaped, molecular mass distributions representing the light-chain repertoire. During the analysis of a large (>100) patient sample set, we noticed a low-intensity molecular mass distribution with a mean of approximately 24 250 Da, roughly 800 Da higher than the mean of the typical kappa molecular-mass distribution mean of 23 450 Da. We also observed distinct clones in this region that did not appear to contain any typical post-translational modifications that would account for such a large mass shift. To determine the origin of the high molecular mass clones, we performed de novo bottom-up mass spectrometry on a purified IgM monoclonal light chain that had a calculated molecular mass of 24 275.03 Da. The entire sequence of the monoclonal light chain was determined using multienzyme digestion and de novo sequence-alignment software and was found to belong to the germline allele IGKV2-30. The alignment of kappa germline sequences revealed ten IGKV2 and one IGKV4 sequences that contained additional amino acids in their CDR1 region, creating the high-molecular-mass phenotype. We also performed an alignment of lambda germline sequences, which showed additional amino acids in the CDR2 region, and the FR3 region of functional germline sequences that result in a high-molecular-mass phenotype. The work presented here illustrates the ability of mass spectrometry to provide information on the diversity of light-chain molecular mass phenotypes in circulation, which reflects the germline sequences selected by the immunoglobulin-secreting B-cell population.


Assuntos
Cadeias kappa de Imunoglobulina/química , Cadeias lambda de Imunoglobulina/química , Sequência de Aminoácidos , Diversidade de Anticorpos , Humanos , Região Variável de Imunoglobulina/sangue , Região Variável de Imunoglobulina/química , Região Variável de Imunoglobulina/genética , Cadeias kappa de Imunoglobulina/sangue , Cadeias kappa de Imunoglobulina/genética , Cadeias lambda de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/genética , Dados de Sequência Molecular , Peso Molecular , Fenótipo , Alinhamento de Sequência , Homologia de Sequência de Aminoácidos , Espectrometria de Massas por Ionização por Electrospray/métodos
20.
J Neuroimmunol ; 288: 123-6, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26531705

RESUMO

Our group has previously shown that mass spectrometry can be used to detect and quantify monoclonal and polyclonal immunoglobulin light chains in serum and urine from patients with monoclonal gammopathies and polyclonal hypergammaglobinemia. Here we demonstrate the use of the methodology, also referred to as monoclonal immunoglobulin Rapid Accurate Mass Measurement\with (miRAMM), to detect oligoclonal immunoglobulins above the polyclonal background in cerebral spinal fluid (CSF) and serum. We compared the findings for 56 paired CSF and serum samples analyzed by IgG IEF and miRAMM. The two methods were in agreement with 54 samples having concordant results (22 positive and 34 negative) and 2 that were positive by IgG IEF but negative by miRAMM. In addition to identifying oligoclonal immunoglobulins, miRAMM can be used to quantify and isotype each specific monoclonal immunoglobulin in CSF. This methodology has the potential to transform the way the inflammatory response is monitored in the CNS compartment.


Assuntos
Espectrometria de Massas/métodos , Bandas Oligoclonais/líquido cefalorraquidiano , Cromatografia Líquida/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA