Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Plast Reconstr Surg Glob Open ; 10(2): e4107, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35169531

RESUMO

Coverage of knee wounds with exposure or violation of the joint capsule has long been a challenge to plastic surgeons. Wide resection and radiation treatment for soft-tissue sarcomas further this difficulty due to resultant diminished vascularity and soft tissue fibrosis. Traditional muscle flaps such as the gastrocnemius may be within the radiated field, limiting their arc of rotation to the knee. We present a series of exposed knee joint reconstructions using pedicled propeller flaps after sarcoma resection. Three patients diagnosed with soft tissue sarcomas underwent neoadjuvant radiation followed by wide local resection by orthopedic oncology. All patients had underlying knee joint exposure and underwent successful soft tissue reconstruction utilizing pedicled anterolateral thigh (ALT) propeller flaps. The ALT flap is widely used in plastic surgery for reconstruction of soft tissue defects due to its reliable vascularity, long pedicle, versatility, low donor-site morbidity, and large size. As a propeller flap, we demonstrate this is a viable alternative for reconstruction when the vascular plexus around the knee is unreliable after neoadjuvant radiation. Extending the ALT propeller flap with a large proximal skin paddle provides a nonmicrosurgical alternative to traditional muscle flaps at this location. The ALT propeller flap is an excellent option for reconstruction of large defects of the knee, especially in the setting of a radiated wound bed with unpredictable vascularity. In our case series, all three patients underwent successful reconstruction of exposed knee joints after resection of soft tissue sarcoma utilizing ALT propeller flaps.

2.
J Am Acad Orthop Surg Glob Res Rev ; 5(5): e20.00261-4, 2021 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-34010236

RESUMO

We report a case of a 40-year-old woman with hyperlipidemia and associated multifocal xanthoma of bone requiring prophylactic fixation of her bilateral femurs. Although xanthomas of bone are themselves a benign process, their presence may indicate that the patient has poorly controlled lipids and is at an increased risk of cardiovascular disease. Lytic lesions may require prophylactic fixation to prevent pathologic fracture.


Assuntos
Doenças Ósseas , Hiperlipidemias , Xantomatose , Adulto , Osso e Ossos/diagnóstico por imagem , Feminino , Humanos , Hiperlipidemias/complicações , Lipídeos , Xantomatose/diagnóstico
3.
AJR Am J Roentgenol ; 212(6): 1377-1384, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30917019

RESUMO

OBJECTIVE. The purpose of this study was to review the efficacy and durability of pain control and local tumor control using microwave ablation and cementoplasty in treating extraspinal osseous tumors. Painful osseous metastases are a common cause of cancer-related morbidity. Percutaneous thermal ablation presents an attractive minimally invasive option in this vulnerable patient group. MATERIALS AND METHODS. A retrospective review included 65 patients (35 men, 30 women) with 77 tumors who underwent image-guided microwave ablation and cementoplasty at a tertiary referral academic center over 18 months. Procedural efficacy was determined with a visual analog scale before the procedure and 24 hours, 2-4 weeks, and 20-24 weeks after the procedure. Locoregional control was assessed at follow-up cross-sectional imaging. RESULTS. The 77 tumors were in the following locations: ilium, 38; acetabulum on supraacetabular region, 23; femur, five; humerus, four; shoulder, four; sternum, three. The tumors were 15 multiple myelomas and metastases from cancers of the following organs: colon, nine; lung, 15; breast, 12; thyroid, seven; prostate, three; and kidney, four. Complete, successful ablation of all 77 tumors was achieved. Mean ablation time was 6 minutes 15 seconds (SD, 12 seconds), and mean energy used was 5.49 (SD, 2.97) kJ. The mean visual analog scale scores were 6.32 (SD, 1.94) before the procedure, 1.01 (SD, 1.24) at 24 hours, 1.71 (SD, 1.31) at 2-4 weeks, and 2.01 (SD, 1.42) at 20-24 weeks. Follow-up imaging at 20-24 weeks showed no local progression in 42 of 65 patients (64.6%). Six patients died 24-52 weeks after the procedure. No procedure-related complications were reported. CONCLUSION. Microwave ablation is efficacious in alleviating pain due to osseous metastases. The modality has promise for locoregional control of metastases, particularly in the context of oligometastatic (limited disseminated) disease.

4.
Orthopedics ; 38(5): e417-22, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25970370

RESUMO

The effect of simulated early weight bearing on both micromotion and pullout strength of uncemented distal femoral stems was evaluated in this study. The effect of stem endosteal contact and bone quality on implant pullout strength was also analyzed. A randomized matched-pair study was performed using 8 bilateral pairs of fresh human cadaveric femoral specimens. Each specimen pair was dual-energy x-ray absorptiometry scanned, uniformly implanted, fluoroscopically imaged, and randomly assigned to the cycled or uncycled group. The cycled group received 5000 cycles of axial compressive loading (to 700 N) and the contralateral side was not cycled. Micromotion was monitored during cycling and compared with a failure threshold (150 µm), and all implants underwent direct axial distraction (pullout) testing. During cycling, minimal micromotion was observed with an asymptotic decrease in differential motion between the first and last 50 cycles. Both cycled and uncycled groups demonstrated no statistical difference in average pullout force (4888±2124 N vs 4367±1154 N; P=.43). The percentage of cortical contact for each implant was determined from panoramic fluoroscopy images using digital image analysis software. Contact area for the distal third of the stem showed the highest correlation with pullout force and with predicting pullout force. Bone quality did not correlate with pullout force (r(2)=0.367) or stem contact area (r(2)=0.394). In sum, press-fit uncemented femoral stems did not loosen or demonstrate decreased pullout strength with early weight bearing simulated by cyclical axial compressive loading.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/diagnóstico por imagem , Suporte de Carga , Absorciometria de Fóton , Idoso , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Falha de Prótese/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA