Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
2.
Eur Heart J Cardiovasc Imaging ; 24(9): e209-e268, 2023 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-37283275

RESUMO

Transcatheter therapies for the treatment of structural heart diseases (SHD) have expanded dramatically over the last years, thanks to the developments and improvements of devices and imaging techniques, along with the increasing expertise of operators. Imaging, in particular echocardiography, is pivotal during patient selection, procedural monitoring, and follow-up. The imaging assessment of patients undergoing transcatheter interventions places demands on imagers that differ from those of the routine evaluation of patients with SHD, and there is a need for specific expertise for those working in the cath lab. In the context of the current rapid developments and growing use of SHD therapies, this document intends to update the previous consensus document and address new advancements in interventional imaging for access routes and treatment of patients with aortic stenosis and regurgitation, and mitral stenosis and regurgitation.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Seleção de Pacientes , Implante de Prótese de Valva Cardíaca/métodos , Consenso , Seguimentos , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia/métodos , Valva Aórtica
4.
Catheter Cardiovasc Interv ; 96(3): E220-E229, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31943728

RESUMO

BACKGROUND: The Coronary Artery Tree description and Lesion EvaluaTion (CatLet) score accommodating the variability in coronary anatomy is a recently developed and comprehensive angiographic scoring system aimed at assisting in risk-stratification of patients with coronary artery disease. However, a validation of this angiographic scoring system is lacking. METHODS: The CatLet score was calculated retrospectively in 308 consecutively enrolled patients with acute myocardial infarction (AMI) undergoing primary percutaneous coronary intervention. The primary endpoint, major adverse cardiac or cerebrovascular events (MACCEs), was stratified according to CatLet tertiles: CatLetlow ≤14 (n = 124), CatLetmid 15-21 (n = 82) and CatLettop ≥22 (n = 102). RESULTS: The CatLet score alone or after adjusting for a broad spectrum of risk factors, significantly predicted clinical outcomes at a median 4.3-year follow-up. Multivariable-adjusted hazard ratios (95%CI)/unit higher score were 1.05 (1.04-1.07) for MACCE, 1.06 (1.04-1.07) for cardiac death, and 1.05 (1.04-1.07) for all-cause death. When compared to the SYNTAX score, improved discrimination and better calibration of this CatLet score resulted in a significantly refined risk stratification. The overall category-free net reclassification improvement afforded by this CatLet score was as follows: 37.2% (p = .008) for MACCEs, 35.5% (p = .0249) for cardiac death, and 31.8% (p = .0316) for all-cause death. CONCLUSIONS: The ability to integrate the variability in coronary anatomy into angiographic scoring makes the CatLet score a more specific tool for outcome predictions in AMI. (http://www.chictr.org.cn. Unique identifiers: ChiCTR-POC-17013536).


Assuntos
Angiografia Coronária , Técnicas de Apoio para a Decisão , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Eur Heart J Suppl ; 22(Suppl M): M19-M25, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33664636

RESUMO

A therapeutic dilemma arises when infective endocarditis (IE) is complicated by a neurologic event. Postponement of surgery up to 4 weeks is recommended by the guidelines, however, this negatively impacts outcomes in many patients with an urgent indication for surgery due to uncontrolled infection, disease progression, or haemodynamic deterioration. The current literature is ambiguous regarding the safety of cardiopulmonary bypass in patients with recent neurologic injury. Nevertheless, most publications demonstrate a lower risk for secondary haemorrhagic conversion of uncomplicated ischaemic lesions than the risk for recurrent embolism under antibiotic treatment. Here, we discuss the current literature regarding neurologic stroke complicating IE with an indication for surgery.

8.
Innovations (Phila) ; 14(1): 5-16, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30848708

RESUMO

Robotic totally endoscopic coronary artery bypass grafting (TECAB) was introduced in 1998 and has over a period of two decades gradually emerged from single-vessel revascularization to multivessel bypass grafting. Dedicated centers have continuously evolved and further developed this minimally invasive method of coronary bypass surgery. A literature review was conducted to assess intra- and postoperative outcomes of TECAB. PubMed returned 19 comprehensive articles on TECAB. Investigation was focused on perioperative outcome parameters, i.e.: operative time, conversion to larger incision, revision for bleeding, atrial fibrillation, stroke, acute renal failure, and mortality. Outcome from the analysis of 2,397 reported cases showed an average operative time of 291 ± 57 minutes (range 112 to 1,050), conversion rate to larger incisions at 11.5%, and perioperative mortality at 0.8%. Pooled data demonstrated 4.2% operative revision rate due to postoperative hemorrhage, 1.0% stroke incidence, 1.6% acute renal failure, and 13.3% de novo atrial fibrillation. The mean length of hospital stay measured 5.8 ± 1.7 days. Conversion rates and operative times decreased over time. According to data in the literature, coronary bypass surgery carried out in completely endoscopic fashion utilizing robotic assistance can require relatively extensive operative times and conversion rates are somewhat higher than in other robotic cardiac surgery. However, major postoperative events lie in an acceptable range. TECAB remains the surgical revascularization method with the least tissue trauma and represents an opportunity for coronary artery bypass grafting via port access. Rates of major complications are at least similar to conventional surgical access procedures.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Endoscopia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Injúria Renal Aguda/complicações , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Período Perioperatório/mortalidade , Complicações Pós-Operatórias/epidemiologia , Hemorragia Pós-Operatória/complicações , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
11.
J Thorac Dis ; 11(12): 5199-5209, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32030237

RESUMO

BACKGROUND: The SYNTAX score for decision makings or outcome predictions in coronary artery disease does not account for the variations in the coronary anatomy, which is a clear fallacy for patients with less typical anatomy than suggested by the SYNTAX score. The current study aimed to derive a new coronary angiographic scoring system accommodating the variability in the coronary anatomy. METHODS: The 17-myocardial segment model and laws of competitive blood supply and flow conservation were utilized to derive this new scoring system. RESULTS: We obtained 6 types of RCA dominance, 3 types of diagonal size and 3 types of left anterior descending artery (LAD) length, which together resulted in a total of 54 patterns of coronary artery circulation to account for the variability in the coronary anatomy among individuals. A Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system has been designed based on the above-mentioned reclassification scheme (htpp://www.catletscore.com, IE browser is required to run this calculator). CONCLUSIONS: This new CatLet angiographic scoring system accommodated the variability in the coronary anatomy and standardized the collection of the coronary angiographic data, which could facilitate the comparison and exchange of these data between different catheter labs. Its utility for predicting the clinical outcomes and standardizing the angiographic data collection will be investigated in a series of clinical trials enrolling "all-comers" with coronary artery disease (CAD).

13.
Eur Heart J Qual Care Clin Outcomes ; 5(3): 252-258, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30304395

RESUMO

AIMS: We analysed the impact of bundle branch block (BBB) and pacemaker (PM) implantation on symptoms and survival after alcohol septal ablation (ASA) in patients with hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: Among 1416 HCM patients from the Euro-ASA registry, 58 (4%) patients had a PM and 64 (5%) patients had an implantable cardioverter-defibrillator (ICD) before ASA. At latest follow-up (5.0 ± 4.0 years) after ASA, 118 (8%) patients had an ICD and 229 (16%) patients had a PM. In patients without an implantable device prior to ASA 13% had a PM and 5% had an ICD implanted following ASA. New onset BBB was present in 44% (right BBB in 31%) of patients without previous BBB. At latest follow-up, we found no associations between BBB and New York Heart Association (NYHA) Class 3-4 [odds ratio (OR) 0.98, 95% confidence interval (CI) 0.63-1.51; P = 0.91] or Canadian Cardiovascular Society (CCS) Class 3-4 (OR 1.5, CI 0.32-6.7; P = 0.62), respectively, and no associations between PM and NYHA Class 3-4 (OR 1.2, CI 0.70-2.0; P = 0.52) or CCS 3-4 (OR 1.3, CI 0.24-6.6; P = 0.79), respectively. The survival after ASA was not reduced in patients with BBB [hazard ratio (HR) 0.73, CI 0.53-1.01; P = 0.06] or PM (HR 0.78, CI 0.52-1.17; P = 0.24). CONCLUSIONS: Development of BBB or need for a PM after ASA in patients with obstructive HCM was not associated with inferior symptomatic outcome or reduced survival, thus concerns for the negative impact of impaired cardiac conduction on the clinical outcome after ASA were not confirmed.


Assuntos
Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Etanol/administração & dosagem , Etanol/efeitos adversos , Marca-Passo Artificial , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taxa de Sobrevida , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 92(7): 1461-1465, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30269405

RESUMO

Left ventricular outflow obstruction after transcatheter mitral valve replacement is a life-threatening complication. We report a case of a 68-year old female with early degeneration of a transcatheter aortic valve and severely calcified mitral valve stenosis who was considered inoperable by a multidisciplinary heart team and referred for transcatheter aortic and mitral valve replacement. Our aim is to report the planning, procedural aspects, and management of device-related left-ventricular outflow tract obstruction after transcatheter double valve replacement.


Assuntos
Técnicas de Ablação , Estenose da Valva Aórtica/cirurgia , Etanol/administração & dosagem , Septos Cardíacos/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Obstrução do Fluxo Ventricular Externo/cirurgia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
18.
Eur J Cardiothorac Surg ; 53(4): 700-707, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29438530

RESUMO

Hypertrophic cardiomyopathy is the most common genetic cardiovascular disorder and is associated with symptoms of heart failure and increased risk of sudden cardiac death. The most common condition is obstruction of the left ventricular outflow tract. Surgical septal myectomy and alcohol septal ablation are the 2 accepted modes of septal reduction therapy and are indicated when there are advanced symptoms and a peak left ventricular outflow gradient ≥50 mmHg. Advantages of alcohol septal ablation are limited groin approach, reduction of obstruction of the left ventricular outflow tract and functional improvement, but there are higher chances for intracardiac device implantation and residual obstruction. Septal myectomy offers very low mortality, absolute and immediate resolution of obstruction of the left ventricular outflow tract and survival comparative to a matched general population with almost negligible residual obstruction. It is recommended that patients with obstructive hypertrophic cardiomyopathy should be treated at experienced centres.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Septos Cardíacos/cirurgia , Humanos , Resultado do Tratamento
19.
Eur Heart J ; 39(15): 1246-1254, 2018 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-28329105

RESUMO

Advanced percutaneous and surgical procedures in structural and congenital heart disease require precise pre-procedural planning and continuous quality control. Although current imaging modalities and post-processing software assists with peri-procedural guidance, their capabilities for spatial conceptualization remain limited in two- and three-dimensional representations. In contrast, 3D printing offers not only improved visualization for procedural planning, but provides substantial information on the accuracy of surgical reconstruction and device implantations. Peri-procedural 3D printing has the potential to set standards of quality assurance and individualized healthcare in cardiovascular medicine and surgery. Nowadays, a variety of clinical applications are available showing how accurate 3D computer reformatting and physical 3D printouts of native anatomy, embedded pathology, and implants are and how they may assist in the development of innovative therapies. Accurate imaging of pathology including target region for intervention, its anatomic features and spatial relation to the surrounding structures is critical for selecting optimal approach and evaluation of procedural results. This review describes clinical applications of 3D printing, outlines current limitations, and highlights future implications for quality control, advanced medical education and training.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiologia/normas , Cardiopatias Congênitas/diagnóstico por imagem , Impressão Tridimensional/instrumentação , Procedimentos Cirúrgicos Cardíacos/normas , Cardiopatias Congênitas/cirurgia , Humanos , Modelos Anatômicos , Período Perioperatório/normas , Próteses e Implantes/normas , Garantia da Qualidade dos Cuidados de Saúde , Software
20.
Can J Cardiol ; 34(1): 16-22, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29275877

RESUMO

BACKGROUND: The current American College of Cardiology Foundation/American Heart Association guidelines on hypertrophic cardiomyopathy state that institutional experience is a key determinant of successful outcomes and lower complication rates of alcohol septal ablation (ASA). The aim of this study was to evaluate the safety and efficacy of ASA according to institutional experience with the procedure. METHODS: We retrospectively evaluated 1310 patients with symptomatic obstructive hypertrophic cardiomyopathy who underwent ASA and were divided into 2 groups. The first-50 group consisted of the first consecutive 50 patients treated at each centre, and the over-50 group consisted of patients treated thereafter (patients 51 and above). RESULTS: In the 30-day follow-up, there was a significant difference in the occurrence of major cardiovascular adverse events (21% in the first-50 group vs 12% in the over-50 group; P < 0.01), which was driven by the occurrence of cardiovascular deaths (2.1% vs 0.4%; P = 0.01) and implanted pacemakers (15% vs 9%; P < 0.01). In the long-term follow-up (5.5 ± 4.1 years), the first-50 group was associated with a significantly higher occurrence of major adverse events (P < 0.01) and higher cardiovascular mortality (P < 0.01). Also, patients in the first-50 group were more likely to self-report dyspnea of New York Heart Association class III/IV (16% vs 10%), to have a left ventricular outflow gradient > 30 mm Hg (16% vs 10%) at the last clinical check-up (P < 0.01 for both), and a probability of repeated septal reduction therapy (P = 0.03). CONCLUSIONS: An institutional experience of > 50 ASA procedures was associated with a lower occurrence of ASA complications, better cardiovascular survival, better hemodynamic and clinical effect, and less need for repeated septal reduction therapy.


Assuntos
Técnicas de Ablação/estatística & dados numéricos , Cardiomiopatia Hipertrófica/cirurgia , Etanol/administração & dosagem , Septos Cardíacos/cirurgia , Técnicas de Ablação/efeitos adversos , Fatores Etários , Baixo Débito Cardíaco , Cardiomiopatia Hipertrófica/mortalidade , Doenças Cardiovasculares/mortalidade , Dispneia/etiologia , Cardioversão Elétrica/estatística & dados numéricos , Europa (Continente)/epidemiologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Sistema de Registros , Retratamento , Estudos Retrospectivos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA