RESUMO
OBJECTIVES: To assess a baseline assessment using developed functional magnetic resonance imaging (fMRI) language paradigms for Arabic-speakers. METHODS: 24-healthy right-handed volunteers scanned on a 3.0 Tesla MRI machine. For fMRI, a BOLD-sensitive sequence used to measure signals over time across 6 language paradigms: rhyming (RH), semantic category generations (SCG), silent word generation (SWG), verb generation picture (VGp), verb generation word (VGw), and verb generation audio (VGa). fMRI data was analyzed using FMRIB Software Library (FSL). RESULTS: We found that VGa, SWG, VGw and VGp robustly activated language-related regions in the dominant hemisphere. RH and SCG failed to adequately define these activation regions but this may be related to the study's preliminary nature and limitations. After assessment of their validity, considerable activation of the inferior frontal gyrus during VGa, SWG, VGw and VGp suggests that these paradigms have the potential for localizing of Broca's area in native Arabic speakers. CONCLUSION: Set of well adapted, and evidence-based, fMRI paradigms were established for Arabic-speakers to enable accurate and sufficient localization and lateralization of the language area. After validation, these paradigms may provide sequences for accurate localization of brain language areas, and could be used as a presurgical evaluation tool.
Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Lateralidade Funcional/fisiologia , Idioma , Imageamento por Ressonância Magnética/métodos , Humanos , Estudos ProspectivosRESUMO
OBJECTIVE: To determine optimal interstimulus interval (ISI) and pulse duration (D) for direct cortical stimulation (DCS) motor evoked potentials (MEPs) based on rheobase and chronaxie derived with two techniques. METHODS: In 20 patients under propofol/remifentanil anesthesia, 5-pulse DCS thenar MEP rheobase and chronaxie with 2, 3, 4 and 5ms ISI were measured by linear regression of five charge thresholds at 0.05, 0.1, 0.2, 0.5 and 1msD, and estimated from two charge thresholds at 0.1 and 1msD using simple arithmetic. Optimal parameters were defined by minimum threshold energy: the ISI with lowest rheobase2×chronaxie, and D at its chronaxie. Near-optimal was defined as threshold energy <25% above minimum. RESULTS: The optimal ISI was 3 or 4 (n=7 each), 2 (n=4), or 5ms (n=2), but only 4ms was always either optimal or near-optimal. The optimal D was â¼0.2 (n=12), â¼0.1 (n=7) or â¼0.3ms (n=1). Two-point estimates closely approximated five-point measurements. CONCLUSIONS: Optimal ISI/D varies, with 4ms/0.2ms being most consistently optimal or near-optimal. Two-point estimation is sufficiently accurate. SIGNIFICANCE: The results endorse 4ms ISI and 0.2msD for general use. Two-point estimation could enable quick individual optimization.