Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 40(20): 10648-10662, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38712915

RESUMO

This study presents new insights into the potential role of polyelectrolyte interfaces in regulating low friction and interstitial fluid pressurization of cartilage. Polymer brushes composed of hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) tethered to a PEEK substrate (SPMK-g-PEEK) are a compelling biomimetic solution for interfacing with cartilage, inspired by the natural lubricating biopolyelectrolyte constituents of synovial fluid. These SPMK-g-PEEK surfaces exhibit a hydrated compliant layer approximately 5 µm thick, demonstrating the ability to maintain low friction coefficients (µ ∼ 0.01) across a wide speed range (0.1-200 mm/s) under physiological loads (0.75-1.2 MPa). A novel polyelectrolyte-enhanced tribological rehydration mechanism is elucidated, capable of recovering up to ∼12% cartilage strain and subsequently facilitating cartilage interstitial fluid recovery, under loads ranging from 0.25 to 2.21 MPa. This is attributed to the combined effects of fluid confinement within the contact gap and the enhanced elastohydrodynamic behavior of polymer brushes. Contrary to conventional theories that emphasize interstitial fluid pressurization in regulating cartilage lubrication, this work demonstrates that SPMK-g-PEEK's frictional behavior with cartilage is independent of these factors and provides unabating aqueous lubrication. Polyelectrolyte-enhanced tribological rehydration can occur within a static contact area and operates independently of known mechanisms of cartilage interstitial fluid recovery established for converging or migrating cartilage contacts. These findings challenge existing paradigms, proposing a novel polyelectrolyte-cartilage tribological mechanism not exclusively reliant on interstitial fluid pressurization or cartilage contact geometry. The implications of this research extend to a broader understanding of synovial joint lubrication, offering insights into the development of joint replacement materials that more accurately replicate the natural functionality of cartilage.


Assuntos
Lubrificação , Polímeros , Polímeros/química , Animais , Polieletrólitos/química , Polietilenoglicóis/química , Cartilagem/química , Cartilagem/efeitos dos fármacos , Propriedades de Superfície , Benzofenonas/química , Cartilagem Articular/química , Cartilagem Articular/fisiologia , Cetonas/química
2.
Proc Inst Mech Eng H ; 238(3): 324-331, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38235693

RESUMO

This biomechanical study aimed to determine if variations in stem material, stem geometry, stem offset and cement viscosity affect mechanical resistance to postoperative periprosthetic fracture (PFF) after hip arthroplasty with a commonly used cemented polished taper-slip (PTS) stem (CPT, Zimmer Biomet) in a novel osteoporotic composite femoral bone model. Thirty-six osteoporotic composite femoral models were tested using a standardised in-vitro loading technique to simulate a typical PFF. Outcome measures were torque to failure (N), fracture energy (N/m2) and rotation to failure (°). Comparisons were made by stem material (cobalt chrome vs stainless steel), stem geometry (CPT stem vs Exeter stem), stem offset (standard offset vs extra extended offset) and cement viscosity (high viscosity vs low viscosity). Statistical comparisons were carried out with significance set at p < 0.05. All tested samples produced clinically representative fracture patterns with varying degrees of bone and cement comminution. There was no statistically significant difference in torque to failure, fracture energy or rotation to failure between any of the compared variables (all p > 0.05). This is the first biomechanical study on mechanical resistance to PFF using osteoporotic composite bone models. For the CPT stem, it confirms that stem material, stem offset, stem geometry and cement viscosity do not affect mechanical resistance to PFF in an osteoporotic bone model.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Desenho de Prótese , Fatores de Risco , Cimentos Ósseos , Fraturas do Fêmur/cirurgia , Reoperação/efeitos adversos
3.
J Mech Behav Biomed Mater ; 147: 106084, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37683556

RESUMO

To enable long lasting osteochondral defect repairs which preserve the native function of synovial joint counter-face, it is essential to develop surfaces which are optimised to support healthy cartilage function by providing a hydrated, low friction and compliant sliding interface. PEEK surfaces were modified using a biocompatible 3-sulfopropyl methacrylate potassium salt (SPMK) through UV photo-polymerisation, resulting in a ∼350 nm thick hydrophilic coating rich in hydrophilic anionic sulfonic acid groups. Characterisation was done through Fourier Transformed Infrared Spectroscopy, Focused Ion Beam Scanning Electron Microscopy, and Water Contact Angle measurements. Using a Bruker UMT TriboLab, bovine cartilage sliding tests were conducted with real-time strain and shear force measurements, comparing untreated PEEK, SPMK functionalised PEEK (SPMK-g-PEEK), and Cobalt Chrome Molybdenum alloy. Tribological tests over 2.5 h at physiological loads (0.75 MPa) revealed that SPMK-g-PEEK maintains low friction (µ< 0.024) and minimises equilibrium strain, significantly reducing forces on the cartilage interface. Post-test analysis showed no notable damage to the cartilage interfacing against the SPMK functionalised surfaces. The application of a constitutive biphasic cartilage model to the experimental strain data reveals that SPMK surfaces increase the interfacial permeability of cartilage in sliding, facilitating fluid and strain recovery. Unlike previous demonstrations of sliding-induced tribological rehydration requiring specific hydrodynamic conditions, the SPMK-g-PEEK introduces a novel mode of tribological rehydration operating at low speeds and in a stationary contact area. SPMK-g-PEEK surfaces provide an enhanced cartilage counter-surface, which provides a highly hydrated and lubricious boundary layer along with supporting biphasic lubrication. Soft polymer surface functionalisation of orthopaedic implant surfaces are a promising approach for minimally invasive synovial joint repair with an enhanced bioinspired polyelectrolyte interface for sliding against cartilage. These hydrophilic surface coatings offer an enabling technology for the next generation of focal cartilage repair and hemiarthroplasty implant surfaces.

4.
Food Res Int ; 102: 478-486, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29195975

RESUMO

Wine creates a group of oral-tactile stimulations not related to taste or aroma, such as astringency or fullness; better known as mouthfeel. During wine consumption, mouthfeel is affected by ethanol content, phenolic compounds and their interactions with the oral components. Mouthfeel arises through changes in the salivary film when wine is consumed. In order to understand the role of each wine component, eight different model wines with/without ethanol (8%), glycerol (10g/L) and commercial tannins (1g/L) were described using a trained panel. Descriptive analysis techniques were used to train the panel and measure the intensity of the mouthfeel attributes. Alongside, the suitability of different instrumental techniques (rheology, particle size, tribology and microstructure, using Transmission Electron Microscopy (TEM)) to measure wine mouthfeel sensation was investigated. Panelists discriminated samples based on their tactile-related components (ethanol, glycerol and tannins) at the levels found naturally in wine. Higher scores were found for all sensory attributes in the samples containing ethanol. Sensory astringency was associated mainly with the addition of tannins to the wine model and glycerol did not seem to play a discriminating role at the levels found in red wines. Visual viscosity was correlated with instrumental viscosity (R=0.815, p=0.014). Hydrodynamic diameter of saliva showed an increase in presence of tannins (almost 2.5-3-folds). However, presence of ethanol or glycerol decreased hydrodynamic diameter. These results were related with the sensory astringency and earthiness as well as with the formation of nano-complexes as observed by TEM. Rheologically, the most viscous samples were those containing glycerol or tannins. Tribology results showed that at a boundary lubrication regime, differences in traction coefficient lubrication were due by the presence of glycerol. However, no differences in traction coefficients were observed in presence/absence of tannins. It is therefore necessary to use an integrative approach that combines complementary instrumental techniques for mouthfeel perception characterization.


Assuntos
Julgamento , Boca/inervação , Percepção Gustatória , Paladar , Percepção do Tato , Tato , Vinho/análise , Difusão Dinâmica da Luz , Etanol/análise , Glicerol/análise , Humanos , Concentração de Íons de Hidrogênio , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Reologia , Taninos/análise , Viscosidade
5.
Proc Inst Mech Eng H ; 230(5): 406-20, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27160560

RESUMO

Corrosion is not routinely considered in the assessment of the degradation or the lifetime of total hip replacement bearing surfaces. Biomechanical simulations are becoming ever more complex and are taking into account motion cycles that represent activities beyond a simple walking gait at 1 Hz, marking a departure from the standard ISO BS 14242. However, the degradation is still very often referred to as wear, even though the material loss occurs due to a combination of tribological and corrosion processes and their interactions. This article evaluates how, by incorporating real-time corrosion measurements in total hip replacement simulations, pre-clinical evaluations and research studies can both yield much more information and accelerate the process towards improved implants.


Assuntos
Corrosão , Prótese de Quadril , Teste de Materiais/métodos , Modelos Biológicos , Fricção , Humanos , Lubrificação , Metais Pesados , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA