Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
JCI Insight ; 4(6)2019 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-30895945

RESUMO

BACKGROUND: Spatial resolution in cardiac activation maps based on voltage measurement is limited by far-field interference. Precise characterization of electrical sources would resolve this limitation; however, practical charge-based cardiac mapping has not been achieved. METHODS: A prototype algorithm, developed from first principles of electrostatic field theory, derives charge density (CD) as a spatial representation of the true sources of the cardiac field. The algorithm processes multiple, simultaneous, noncontact voltage measurements within the cardiac chamber to inversely derive the global distribution of CD sources across the endocardial surface. RESULTS: Comparison of CD to an established computer-simulated model of atrial conduction demonstrated feasibility in terms of spatial, temporal, and morphologic metrics. Inverse reconstruction matched simulation with median spatial errors of 1.73 mm and 2.41 mm for CD and voltage, respectively. Median temporal error was less than 0.96 ms and morphologic correlation was greater than 0.90 for both CD and voltage. Activation patterns observed in human atrial flutter reproduced those established through contact maps, with a 4-fold improvement in resolution noted for CD over voltage. Global activation maps (charge density-based) are reported in atrial fibrillation with confirmed reduction of far-field interference. Arrhythmia cycle-length slowing and termination achieved through ablation of critical points demonstrated in the maps indicates both mechanistic and pathophysiological relevance. CONCLUSION: Global maps of cardiac activation based on CD enable classification of conduction patterns and localized nonpulmonary vein therapeutic targets in atrial fibrillation. The measurement capabilities of the approach have roles spanning deep phenotyping to therapeutic application. TRIAL REGISTRATION: ClinicalTrials.gov NCT01875614. FUNDING: The National Institute for Health Research (NIHR) Translational Research Program at Royal Papworth Hospital and Acutus Medical.


Assuntos
Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Endocárdio/fisiopatologia , Átrios do Coração/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Potenciais de Ação/fisiologia , Adolescente , Adulto , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Simulação por Computador , Ecocardiografia , Eletrocardiografia , Endocárdio/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Átrios do Coração/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Análise Espaço-Temporal , Taquicardia Supraventricular/fisiopatologia , Tomografia Computadorizada por Raios X , Adulto Jovem
2.
Pacing Clin Electrophysiol ; 26(1 Pt 1): 16-25, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12685135

RESUMO

The success rate for catheter ablation of ectopic atrial tachycardia (AT) has been limited by the inherent difficulty in localizing the site of origin within the complex three-dimensional structures of the atria. The objective of the study was to determine the usefulness of a noncontact mapping system for catheter ablation of AT. Radiofrequency ablation of 25 ATs was performed using a noncontact mapping system. Three different characteristics of isopotential maps and unipolar electrogram morphologies were observed: Group 1: Isopotential maps displayed a narrow, sharp ring of colors around a white, center spot. Unipolar electrograms revealed a Q-S morphology with a rapid dV/dt. Group 2: Isopotential maps displayed a broad ring of colors with little or no white spot in the center. Unipolar electrograms revealed a low amplitude, broad and smooth Q-S morphology in front of a second component with a rapid dV/dt. Group 3: Isopotential maps displayed a broad ring of colors. Unipolar electrogams revealed a low amplitude and fractionated waveform followed by endocardial breakthrough with a gradual dV/dt. Radiofrequency catheter ablation was successful in all ATs of groups 1 and 2, and failed in two of three ATs in group 3. The overall success rate was 92%. No severe complications were observed. Noncontact isopotential mapping is helpful to identify and characterize the origin of ectopic AT. Ablation success is associated with the characteristics of isopotential maps and unipolar electrogram morphologies. The overall success rate was 92%.


Assuntos
Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Atrial Ectópica/diagnóstico , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Atrial Ectópica/cirurgia
3.
J Cardiovasc Electrophysiol ; 14(2): 135-41, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12693492

RESUMO

INTRODUCTION: Little is known about the septal activation pattern in patients with heart failure and left bundle branch block (LBBB-HF). METHODS AND RESULTS: The right ventricular (RV) and left ventricular (LV) activation patterns of 12 patients (mean age 67 +/- 11 years) with LBBB-HF and 5 patients (mean age 45 +/- 14) with normal hearts were studied during sinus rhythm using a three-dimensional mapping system. The etiology of HF was myocardial infarction (n = 4) or idiopathic dilated cardiomyopathy (n = 8). In patients with LBBB-HF, endocardial activation usually started before the onset of the surface QRS complex on the RV free wall. Latest RV activation occurred in the basal region, and total RV activation time was longer than in patients with normal hearts. In patients with LBBB-HF, the left septum was activated via slowly conducting LBB or via right-to-left transseptal conduction. In both patients with LBBB-HF and those with normal hearts, latest LV activation occurred either in the posterior or posterolateral-basal region. Conduction velocity was slower in the peri-scar region, in patients with previous myocardial infarct and globally slow, in patients with idiopathic dilated cardiomyopathy. CONCLUSION: The two types of left septal activation observed in patients with LBBB-HF may have consequences for biventricular hemodynamic performance. Conduction slowing along the LV, regionally or globally, suggests a contribution outside the specific conduction system in the ECG pattern of LBBB.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Bloqueio de Ramo/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Septos Cardíacos/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Cardiomiopatia Dilatada/complicações , Endocárdio/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Humanos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Transmissão Sináptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA