Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol Exp ; 8(1): 105, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39298080

RESUMO

BACKGROUND: Regular disease monitoring with low-dose high-resolution (LD-HR) computed tomography (CT) scans is necessary for the clinical management of people with cystic fibrosis (pwCF). The aim of this study was to compare the image quality and radiation dose of LD-HR protocols between photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) in pwCF. METHODS: This retrospective study included 23 pwCF undergoing LD-HR chest CT with PCCT who had previously undergone LD-HR chest CT with EID-CT. An intraindividual comparison of radiation dose and image quality was conducted. The study measured the dose-length product, volumetric CT dose index, effective dose and signal-to-noise ratio (SNR). Three blinded radiologists assessed the overall image quality, image sharpness, and image noise using a 5-point Likert scale ranging from 1 (deficient) to 5 (very good) for image quality and image sharpness and from 1 (very high) to 5 (very low) for image noise. RESULTS: PCCT used approximately 42% less radiation dose than EID-CT (median effective dose 0.54 versus 0.93 mSv, p < 0.001). PCCT was consistently rated higher than EID-CT for overall image quality and image sharpness. Additionally, image noise was lower with PCCT compared to EID-CT. The average SNR of the lung parenchyma was lower with PCCT compared to EID-CT (p < 0.001). CONCLUSION: In pwCF, LD-HR chest CT protocols using PCCT scans provided significantly better image quality and reduced radiation exposure compared to EID-CT. RELEVANCE STATEMENT: In pwCF, regular follow-up could be performed through photon-counting CT instead of EID-CT, with substantial advantages in terms of both lower radiation exposure and increased image quality. KEY POINTS: Photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) were compared in 23 people with cystic fibrosis (pwCF). Image quality was rated higher for PCCT than for EID-CT. PCCT used approximately 42% less radiation dose and offered superior image quality than EID-CT.


Assuntos
Fibrose Cística , Fótons , Doses de Radiação , Radiografia Torácica , Tomografia Computadorizada por Raios X , Fibrose Cística/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Masculino , Feminino , Adulto , Radiografia Torácica/métodos , Razão Sinal-Ruído , Adulto Jovem
2.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38535017

RESUMO

Background: This study aimed to evaluate the impact of an AI-assisted fracture detection program on radiology residents' performance in pediatric and adult trauma patients and assess its implications for residency training. Methods: This study, conducted retrospectively, included 200 radiographs from participants aged 1 to 95 years (mean age: 40.7 ± 24.5 years), encompassing various body regions. Among these, 50% (100/200) displayed at least one fracture, totaling one hundred thirty-five fractures, assessed by four radiology residents with different experience levels. A machine learning algorithm was employed for fracture detection, and the ground truth was established by consensus among two experienced senior radiologists. Fracture detection accuracy, reporting time, and confidence were evaluated with and without AI support. Results: Radiology residents' sensitivity for fracture detection improved significantly with AI support (58% without AI vs. 77% with AI, p < 0.001), while specificity showed minor improvements (77% without AI vs. 79% with AI, p = 0.0653). AI stand-alone performance achieved a sensitivity of 93% with a specificity of 77%. AI support for fracture detection significantly reduced interpretation time for radiology residents by an average of approximately 2.6 s (p = 0.0156) and increased resident confidence in the findings (p = 0.0013). Conclusion: AI support significantly enhanced fracture detection sensitivity among radiology residents, particularly benefiting less experienced radiologists. It does not compromise specificity and reduces interpretation time, contributing to improved efficiency. This study underscores AI's potential in radiology, emphasizing its role in training and interpretation improvement.

4.
Pediatr Emerg Care ; 38(2): e639-e643, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267157

RESUMO

OBJECTIVES: The Manchester Triage System (MTS) has entered widespread international use in emergency departments (EDs). This retrospective study analyzes urgency of patient visits (PV) at the ED of the Clinic for Pediatrics at the Medical University of Innsbruck. METHODS: We collected demographic and outcome information, including PV urgency levels (UL) according to the MTS, for 3 years (2015-2018), separating PV during regular office hours (ROH; 8:00 am to 5:00 pm) from PV during afternoon and night hours (5:00 pm to 8:00 am), and PV on weekdays from PV on weekends and bank holidays (WE). RESULTS: A total of 56,088 PV were registered with a UL. Most (68.4%) PV were classified as nonurgent. During ROH, more PV per hour (PV/h) were recorded than during afternoon and night hours (3.0 PV/h vs 1.6 PV/h), with a higher proportion of less urgent cases during ROH. On WE, the amount of PV/h was higher than on weekdays (3.6 PV/h vs 2.8 PV/h), with a higher proportion of nonurgent cases (74.6% vs 68.6%). Likelihoods of inpatient admission and hospital stay lengths increased in step with UL. CONCLUSIONS: The MTS proved useful for delineating UL distributions. The MTS analyses may be of value in managing EDs. Prompted by the results of our study, a general practice pediatric care unit was established to support the ED during WE.


Assuntos
Serviço Hospitalar de Emergência , Triagem , Áustria , Criança , Hospitais Universitários , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA