1.
Australas Phys Eng Sci Med ; 38(2): 255-61, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26048719

RESUMO

Although wide bore computed tomography (CT) scanners provide increased space for patients, the scan field of view (sFOV) remains considerably smaller than the bore size. Consequently, patient anatomy which spans beyond the sFOV is truncated and the information is lost. As a solution, some manufacturers provide the capacity to reconstruct CT images from a partial dataset at an extended field of view (eFOV). To assess spatial distortion within this eFOV three phantoms were considered a 30 × 30 × 20 cm(3) slab of solid water, the Gammex electron density CT phantom and a female anthropomorphic phantom. For each phantom, scans were taken centrally within the sFOV as a reference image and with the phantom edge extended at 1 cm intervals from 0 to 5 cm beyond the sFOV into the eFOV. To assess CT number accuracy various tissue equivalent materials were scanned in the eFOV and resulting CT numbers were compared to inserts scanned within the sFOV. For all phantom geometries, objects within the eFOV were geometrically overestimated with elongation of phantom shapes into the eFOV. The percentage increase in size ranged from 0.22 to 15.94 % over all phantoms considered. The difference between eFOV and sFOV CT numbers was dependent upon insert density. The eFOV underestimated CT numbers in the range of -127 to -230 HU for soft tissue densities and -278 to -640 for bone densities. This trend reversed for low tissue densities with the CT numbers in the eFOV being overestimated by 100-130 HU for lung equivalent inserts. Initial correlation between eFOV and sFOV CT numbers was seen and a correction function was successfully applied to better estimate the CT number representative of that seen within the sFOV.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas
2.
Med Phys ; 40(11): 111702, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24320410

RESUMO

PURPOSE: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 µGy m(2)/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named "magic phantom." METHODS: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array "magic plate" (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the (192)Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a (192)Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ. RESULTS: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively. CONCLUSIONS: Our characterization of the designed QA "magic phantom" with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.


Assuntos
Braquiterapia/métodos , Ar , Algoritmos , Catéteres , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Radioisótopos de Irídio/uso terapêutico , Método de Monte Carlo , Agulhas , Imagens de Fantasmas , Controle de Qualidade , Radiometria/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Software