RESUMO
The two surgical options for mitral valve regurgitation are replacement and repair, with annuloplasty being the cornerstone of correction. In cases of repair failure, especially in high surgical risk patients, transcatheter mitral valve-in-ring (MViR) procedures represent emerging and challenging options. Among the several complications linked to this treatment, this paper delves into the role that native mitral leaflets may play in precipitating acute bioprosthesis dysfunction in the MViR procedure. The literature extensively covers complications related to the anterior leaflet, including risks such as outflow tract obstruction and residual mitral insufficiency due to interaction between native and prosthetic leaflets. Conversely, complications involving the posterior leaflet are less understood and often overlooked. In this gap in the literature, we present a clinical case highlighting how a redundant native posterior mitral leaflet can unexpectedly lead to acute severe mitral insufficiency by interfering with prosthetic leaflets.
RESUMO
Data deriving from patients who underwent TAVR between 2007 and 2017 in 13 Italian centers were prospectively collected. Patients were stratified in those with normal LVEF and reduced LVEF. The latter was further classified according to ischemic or nonischemic etiology. The primary end point was a composite of all-cause death and rehospitalizations; the secondary end points were the isolated composers of the primary end point and cardiac death. Overall, 2,626 patients were included in the analysis: 68.1% with normal LVEF and 31.9% with reduced LVEF. At 8 years, reduced LVEF was significantly associated with the primary end point (adjusted hazard ratio 1.17, 95% confidence interval 1.06 to 1.29). Consistent findings were evident for the composite end point. No differences in these trends were found at the 30-day landmark analyses. Compared with nonischemic etiology, ischemic reduced LVEF was associated with an increased risk of cardiac death (adjusted hazard ratio 1.43, 95% confidence interval 1.02 to 2.02). In conclusion, patients with reduced LVEF who underwent TAVR are exposed to a progressively increased risk of death and rehospitalizations, even at very long-term follow-up.
RESUMO
BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.
Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Idoso de 80 Anos ou mais , Resultado do Tratamento , Desenho de Prótese , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , SeguimentosRESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Fatores de Risco , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Resultado do Tratamento , Idoso de 80 Anos ou mais , Incidência , Fatores de Tempo , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/fisiopatologia , Europa (Continente) , Medição de Risco , Desenho de Prótese , Razão de Chances , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Estudos RetrospectivosRESUMO
Mitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis. Emerging transcatheter techniques, such as transcatheter mitral valve replacement (TMVR) and lithotripsy-facilitated percutaneous mitral commissurotomy (PMC), represent promising alternatives for DMS patients deemed unfit for surgery. In particular, intravascular lithotripsy (IVL) has shown potential in facilitating percutaneous interventions by fracturing calcific deposits and enabling subsequent interventions. However, larger prospective studies are warranted to validate these findings and establish IVL's role in DMS management. To further enhance this technique, research could focus on investigating the long-term outcomes and durability of mitral lithotripsy, as well as exploring its potential in combination with PMC or TMVR.
RESUMO
Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.
Assuntos
Embolia Paradoxal , Forame Oval Patente , Acidente Vascular Cerebral , Adulto , Humanos , Embolia Paradoxal/etiologia , Embolia Paradoxal/prevenção & controle , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Prospectivos , Prevenção Secundária/métodos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Resultado do TratamentoRESUMO
BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de PróteseRESUMO
BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.
Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.
Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversosRESUMO
Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgiaRESUMO
BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Hemorragia/induzido quimicamente , Anticoagulantes/efeitos adversos , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do TratamentoAssuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Falha de Prótese , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do TratamentoRESUMO
Este estudo teve como objetivo explorar a percepção de alunos de graduação em relação à sua participação em uma intervenção baseada na terapia de aceitação e compromisso (acceptance and commitment therapy[ACT]), para redução da inflexibilidade psicológica (IP) e do estresse em estudantes universitários. Participaram da pesquisa 21 alunos, de diferentes cursos de graduação, com idade média de 23,4 ± 5,61, sendo 71,4% do sexo feminino e 28,6% do sexo masculino. Os dados coletados nas entrevistas foram submetidos à análise de conteúdo e organizados em quatro categorias: experiência no programa, utilidade, viabilidade e sugestões e processos da ACT. Os resultados possibilitaram identificar que o programa foi uma experiên-cia positiva para os participantes. Além disso, constatou-se que a intervenção foi útil e viável, e possibili-tou que os estudantes desenvolvessem as habilidades necessárias para lidar melhor com as adversidades do dia a dia, sem que precisassem se afastar dos seus valores pessoais.
This study aims to explore undergraduate students' perception of their participation in an intervention, based on acceptance and commitment therapy (ACT), to reduce psychological inflexibility (PI) and stress in undergraduate students. Twentyone students from different undergraduate programs participated in the research, with an average age of 23.4 ± 5.61, of whom 71.4% were female and 28.6% were male. The data collected in the interviews were submitted to content analysis and organized into four categories: experience in the program, utility, feasibility, and ACT suggestions and processes. The results made it possible to identify that the program was a positive experience for the participants, the intervention was useful and feasible and enabled students to develop the requirements to better deal with the adversities of daily life without departing from their personal values.
Este estudio tiene como objetivo explorar la percepción de los estudiantes de pregrado sobre su participa-ción en una intervención, basada en la terapia de aceptación y compromiso (acceptance and commitment therapy [ACT]), para reducir la inflexibilidad psicológica (IP) y el estrés en los estudiantes de pregrado. En la investigación participaron 21 estudiantes de diferentes carreras, con una edad promedio de 23,4 ± 5,61, de los cuales el 71,4% eran mujeres y el 28,6% hombres. Los datos recolectados en las entrevistas fueron sometidos a análisis de contenido y organizados en cuatro categorías: experiencia en el programa, utilidad, factibilidad y sugerencias y procesos de ACT. Los resultados permitieron identificar que el programa fue una experiencia positiva para los participantes, la intervención fue útil y factible y permitió a los estudian-tes desarrollar los requisitos necesarios para enfrentar mejor las adversidades de la vida diaria, sin apar-tarse de sus valores personales.
Assuntos
Humanos , Masculino , Feminino , Estresse Psicológico , Terapia de Aceitação e Compromisso , Psicologia , Estudantes , Saúde Mental , Pesquisa Qualitativa , Atividades Científicas e TecnológicasRESUMO
The impact of sex on pathophysiological processes, clinical presentation, treatment options, as well as outcomes of degenerative aortic stenosis remain poorly understood. Female patients are well represented in transfemoral aortic valve implantation (TAVI) trials and appear to derive favorable outcomes with TAVI. However, higher incidences of major bleeding, vascular complications, and stroke have been reported in women following TAVI. The anatomical characteristics and pathophysiological features of aortic stenosis in women might guide a tailored planning of the percutaneous approach. We highlight whether a sex-based TAVI management strategy might impact on clinical outcomes. This review aimed to evaluate the impact of sex from diagnosis to treatment of degenerative aortic stenosis, discussing the latest evidence on epidemiology, pathophysiology, clinical presentation, therapeutic options, and outcomes. Furthermore, we focused on technical sex-oriented considerations in TAVI including the preprocedural screening, device selection, implantation strategy, and postprocedural management.