Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ann Glob Health ; 86(1): 39, 2020 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-32322537

RESUMO

Engineering technology plays a pivotal role in the delivery of health care in under-resourced countries by providing an infrastructure to improve patient outcomes. However, sustainability of these technologies is difficult in these settings oftentimes due to limited resources or training. The framework presented in this editorial focuses on establishing medical and laboratory equipment sustainability in developing countries and is comprised of four steps: 1) establishing reliable in-country relationships with stakeholders, 2) identifying needs for sustainable solutions locally, 3) exploring potential solutions and assessing their effort-to-impact ratios, and 4) working with strategic partners to implement solutions with clear performance metrics. By focusing on the sustainability of donated equipment instead of the equipment itself, this method presented distinguishes itself from other philanthropic endeavors in the field by seeking to establish preventive maintenance habits that can impact clinical outcomes of a community long term. Application of this methodology is reported in the Original Research Article "A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate" by Asp et. al.


Assuntos
Países em Desenvolvimento , Equipamentos e Provisões , Recursos em Saúde , Avaliação de Programas e Projetos de Saúde , Utilização de Equipamentos e Suprimentos , Humanos , Manutenção , Avaliação das Necessidades , Organizações sem Fins Lucrativos , Participação dos Interessados , Ensino
2.
Ann Glob Health ; 86(1): 16, 2020 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-32090023

RESUMO

Introduction: A clean and functional microscope is necessary for accurate diagnosis of infectious diseases. In tropical climates, high humidity levels and improper storage conditions allow for the accumulation of debris and fungus on the optical components of diagnostic equipment, such as microscopes. Objective: Our objective was to develop and implement a low-cost, sustainable, easy to manage, low-maintenance, passive humidity control chamber to both reduce debris accumulation and microbial growth onto the optical components of microscopes. Methods: Constructed from easily-sourced and locally available materials, the cost of each humidity control chamber is approximately $2.35 USD. Relative humidity levels were recorded every 30 minutes over a period of 10 weeks from two chambers deployed at the Belize Vector and Ecology Center and the University of Belize. Results: The humidity control chamber deployed at the University of Belize maintained internal relative humidity at an average of 35.3% (SD = 4.2%) over 10 weeks, while the average external relative humidity was 86.4% (SD = 12.4%). The humidity control chamber deployed at the Belize Vector and Ecology Center effectively maintained internal relative humidity to an average of 54.5% (SD = 9.4%) over 10 weeks, while the average external relative humidity was 86.9% (SD = 12.9%). Conclusions: Control of relative humidity is paramount for the sustainability of medical equipment in tropical climates. The humidity control chambers reduced relative humidity to levels that were not conducive for fungal growth while reducing microscope contamination from external sources. This will likely extend the service life of the microscopes while taking advantage of low-cost, locally sourced components.


Assuntos
Umidade/prevenção & controle , Higroscópicos , Microscopia/instrumentação , Clima Tropical , Belize , Custos e Análise de Custo , Contaminação de Equipamentos/economia , Contaminação de Equipamentos/prevenção & controle , Equipamentos e Provisões , Fungos/crescimento & desenvolvimento , Humanos , Umidade/efeitos adversos , Higroscópicos/economia , Microscopia/economia , Dióxido de Silício/economia
3.
Magn Reson Imaging ; 39: 132-137, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-26743429

RESUMO

Low back pain (LBP) is a costly and widely prevalent health disorder in the U.S. One of the most common causes of LBP is degenerative disc disease (DDD). There are many imaging techniques to characterize disc degeneration; however, there is no way to directly assess the material properties of the intervertebral disc (IVD) within the intact spine. Magnetic resonance elastography (MRE) is an MRI-based technique for non-invasively mapping the mechanical properties of tissues in vivo. The purpose of this study was to investigate the feasibility of using MRE to detect shear wave propagation in and determine the shear stiffness of an axial cross-section of an ex vivo baboon IVD, and compare with shear displacements from a finite element model of an IVD motion segment in response to harmonic shear vibration. MRE was performed on two baboon lumbar spine motion segments (L3-L4) with the posterior elements removed at a range of frequencies (1000-1500Hz) using a standard clinical 1.5T MR scanner. Propagating waves were visualized in an axial cross-section of the baboon IVDs in all three motion-encoding directions, which resembled wave patterns predicted using finite element modeling. The baboon nucleus pulposus showed an average shear stiffness of 79±15kPa at 1000Hz. These results suggest that MRE is capable of visualizing shear wave propagation in the IVD, assessing the stiffness of the nucleus of the IVD, and can differentiate the nucleus and annulus regions.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Análise de Elementos Finitos , Humanos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/patologia , Dor Lombar , Vértebras Lombares/patologia , Movimento (Física) , Papio , Pressão , Vibração
4.
J Biomech Eng ; 138(5): 054502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26974192

RESUMO

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiologia , Fenômenos Mecânicos , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fluoroscopia , Humanos , Movimento
5.
PLoS One ; 10(10): e0139384, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26466092

RESUMO

INTRODUCTION: An increased bone mineral density (BMD) in the proximity to tendon insertion can improve rotator cuff repair and healing. However, how a decrease of BMD in the humeral head affects the biomechanical properties of the rotator cuff tendon is still unclear. Previous studies have demonstrated ovariectomy in animals to lead to osteoporosis and decreased BMD, and Teriparatide (PTH) administration to improve BMD and strength of bone. This study aimed to explore the correlation between humeral head BMD and infraspinatus (ISP) tendon insertion strength, and if an increase in bone quantity of the humeral head can improve the strength of the rotator cuff. MATERIALS AND METHODS: Eighteen New England white rabbits were divided into the 3 groups: Control, Ovariectomy-Saline (OVX-Saline), and Ovariectomy-PTH (OVX-PTH). The OVX-Saline group and the OVX-PTH were administered daily saline and Teriparatide injections for 8 weeks starting at 17 weeks of OVX. BMD of the humeral head was measured, the ISP tendon failure load was tested and the failure stress was calculated. One specimen from each group was used for histological analysis. Linear regression analysis was used to derive equations for the BMD and failure stress. RESULTS: Significant differences were observed in the measured humeral head BMD of the Control and OVX-PTH groups compared to the OVX-Saline group (P = 0.0004 and P = 0.0024, respectively). No significant difference was found in failure stress among the three groups, but an expected trend with the control group and OVX-PTH group presenting higher failure strength compared to the OVX-Saline group. BMD at the humeral head showed a positive linear correlation with stress (r2 = 0.54). Histology results showed the superiority in OVX-PTH group ISP enthesis compared to the OVX-Saline group. CONCLUSION: Bone loss of the humeral head leads to decreased tendon/bone insertion strength of the infraspinatus tendon enthesis. Teriparatide administration can increase bone density of the humeral head and may improve the mechanical properties of the infraspinatus tendon enthesis.


Assuntos
Densidade Óssea , Osteoporose/metabolismo , Lesões do Manguito Rotador , Manguito Rotador/fisiopatologia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Feminino , Cabeça do Úmero/patologia , Úmero/patologia , Modelos Lineares , Ovariectomia , Coelhos , Fatores de Risco , Tendões/fisiopatologia , Teriparatida/química , Cicatrização
6.
J Magn Reson Imaging ; 41(2): 369-75, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24497052

RESUMO

PURPOSE: To evaluate the feasibility of using three-dimensional (3D) MR elastography (MRE) to determine the stiffness of the pancreas in healthy volunteers. MATERIALS AND METHODS: Twenty healthy volunteers underwent 1.5 Tesla MRE exams using an accelerated echo planar imaging (EPI) pulse sequence with low-frequency vibrations (40 and 60 Hz). Stiffness was calculated with a 3D direct inversion algorithm. The mean shear stiffness in five pancreatic subregions (uncinate, head, neck, body, and tail) and the corresponding liver stiffness were calculated. The intrasubject coefficient of variation (CV) was calculated as a measure of the reproducibility for each volunteer. RESULTS: The mean shear stiffness (average of values obtained in different pancreatic subregions) was (1.15 ± 0.17) kPa at 40 Hz, and (2.09 ± 0.33) kPa at 60 Hz. The corresponding liver stiffness was higher than the pancreas stiffness at 40 Hz ([1.60 ± 0.21] kPa, mean pancreas-to-liver stiffness ratio: 0.72), but similar at 60Hz ([2.12 ± 0.23) kPa, mean ratio: 0.95). The mean intrasubject CV for each pancreatic subregion was lower at 40 Hz than 60 Hz (P < 0.05 for all subregions, range: 11.9-15.7% at 40 Hz and 16.5-19.6% at 60 Hz). CONCLUSION: The 3D pancreatic MRE can provide promising and reproducible stiffness measurements throughout the pancreas, with more consistent data acquired at 40 Hz.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Pâncreas/fisiologia , Adulto , Algoritmos , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade