Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Immunol Methods ; 474: 112661, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31442464

RESUMO

BACKGROUND: Myositis specific antibodies (MSA) represent not only important diagnostic tools for idiopathic inflammatory myopathies (IIM), but also help to stratify patients into subsets with particular clinical features, treatment responses, and disease outcome. Consequently, standardization of MSA is of high importance. Although many laboratories rely on protein immunoprecipitation (IP) for the detection of MSA, IP standardization is challenging and therefore reliable alternatives are mandatory. Recently, we identified significant variation between IP and line immunoassay (LIA) for the detection of MSA and myositis associated antibodies. In this study we aimed to compare the results from our previous study to the results obtained with a novel fully automated particle-based technology for the detection of MSA and MAA. METHODS: A total of 54 sera from patients with idiopathic inflammatory myopathy (IIM) were tested using three methods: IP, LIA (Euroimmun, Germany) and a novel particle-based multi-analyte technology (PMAT, Inova Diagnostics, US, research use only). The analysis focused on antibodies to EJ, SRP, Jo-1, NXP-2, MDA5, TIF1-γ, and Mi-2. RESULTS: Significant variations were observed among all methods. Overall, the novel PMAT assays showed slightly better correlation with IP, but the kappa agreement was strongly dependent on the antibody tested. When the results obtained from IP were used as reference for receiver operating characteristic (ROC) curve analysis, good discrimination and a high area under the curve (AUC) value were found for PMAT (AUC = 0.83, 95% confidence interval, CI 0.70-0.95) which was significantly higher (p = .0332) than the LIA method (AUC = 0.70, 95% CI 0.56-0.84). CONCLUSION: The novel PMAT used to detect a spectrum of MSA in IIM represents a potential alternative to IP and other diagnostic assays. Additional studies based on larger cohorts are needed to fully assess the performance of the novel PMAT system for the detection of autoantibodies in myositis.


Assuntos
Autoanticorpos/sangue , Imunoensaio , Miosite/diagnóstico , Automação Laboratorial , Biomarcadores/sangue , Humanos , Imunoprecipitação , Miosite/sangue , Miosite/imunologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Immunol Res ; 65(1): 276-281, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27618830

RESUMO

Anti-HMGCR antibodies represent a characteristic serological feature of statin-exposed and statin-unexposed patients with immune-mediated necrotizing myopathy (IMNM). We assessed anti-HMGCR antibodies in patients with suspected IMNM following statin exposure and patients with other autoimmune rheumatic diseases. We evaluated the presence of anti-HMGCR autoantibodies in sera samples from 13 statin-exposed patients who were suspected of having IMNM, 38 patients with different inflammatory and autoimmune rheumatic diseases and 29 healthy subjects. The autoantibodies were evaluated by two assays: a new chemiluminescence QUANTA Flash HMGCR kit utilizing BIO-FLASH system and QUANTA Lite® HMGCR ELISA kit. Twelve samples from patients with suspicion for IMNM were found positive for anti-HMGCR antibodies by both assays. Only one of the 13 samples that were found positive by ELISA was negative by CIA. A very good qualitative correlation (κ = 0.95; 95 % CI 0.85-1.0) and quantitative agreement (Spearman's rho 0.87; P value < 0.0001; 95 % CI 0.62-0.96) were found between these two assays. All samples from healthy subjects and from the disease-controlled patient cohort were negative for anti-HMGCR antibodies. In comparison with ELISA results, the CIA exhibited high sensitivity and specificity values of 92.3 and 100 %, respectively. Receiver operating characteristic analysis for CIA and ELISA yielded area under the curve values of 0.99. The presence of anti-HMGCR antibodies may be a useful biomarker of IMNM in statin-exposed patients. There is a good correlation between the two anti-HMGCR antibody assays evaluated in the present study.


Assuntos
Autoanticorpos/sangue , Doenças Autoimunes/diagnóstico , Hidroximetilglutaril-CoA Redutases/imunologia , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Doenças Musculares/diagnóstico , Autoanticorpos/imunologia , Doenças Autoimunes/sangue , Doenças Autoimunes/tratamento farmacológico , Doenças Autoimunes/imunologia , Biomarcadores/sangue , Linhagem Celular Tumoral , Ensaio de Imunoadsorção Enzimática , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Medições Luminescentes , Doenças Musculares/sangue , Doenças Musculares/induzido quimicamente , Doenças Musculares/imunologia , Sensibilidade e Especificidade
4.
Lupus ; 25(8): 864-72, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27252263

RESUMO

OBJECTIVE: Anti-double stranded desoxyribonucleic acid (anti-dsDNA) antibodies are considered fairly specific for systemic lupus erythematosus (SLE) and their quantification is useful for the clinical management of SLE patients. We assessed the diagnostic performance of the QUANTA Flash dsDNA chemiluminescent immunoassay (CIA) in comparison to an ELISA, using patients from five participating countries. The main focus was to evaluate the correlation between anti-dsDNA antibody results from the CIA and global SLE disease activity, as measured by the SLE Disease Activity Index 2000 (SLEDAI-2K). PATIENTS AND METHODS: A total of 1431 samples (SLE, n = 843; disease controls, n = 588) from five countries (Canada, USA, Portugal, Sweden and Spain) were tested with QUANTA Flash dsDNA (Inova Diagnostics, San Diego, CA, USA). Data obtained with the QUANTA Lite dsDNA SC ELISA (Inova Diagnostics) were available for samples from three sites (Canada, USA and Sweden, n = 566). The SLEDAI-2K scores were available for 805 SLE patients and a cut-off of > 4 was used to define active disease. RESULTS: QUANTA Flash dsDNA had a sensitivity of 54.3% for the diagnosis of SLE, combined with 89.8% specificity. Anti-dsDNA antibody levels were significantly higher (p < 0.0001) in active SLE (SLEDAI-2K > 4; n = 232; median value 83.0 IU/mL) versus the inactive patients (n = 573; median value 22.3 IU/mL), and the SLEDAI-2K scoring correlated with their dsDNA antibody levels (Spearman's rho = 0.44, p < 0.0001). Similar but less pronounced findings were also found for the ELISA, in relation to disease activity. CONCLUSIONS: The QUANTA Flash dsDNA assay showed good clinical performance in a large international multi-center study. Additionally, the strong correlation between anti-dsDNA antibody results and SLEDAI-2K scores supported the potential utility of QUANTA Flash dsDNA for monitoring disease activity.


Assuntos
Anticorpos Antinucleares/sangue , DNA/imunologia , Medições Luminescentes/métodos , Lúpus Eritematoso Sistêmico/imunologia , Adulto , Canadá , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Lúpus Eritematoso Sistêmico/diagnóstico , Masculino , Pessoa de Meia-Idade , Portugal , Sensibilidade e Especificidade , Espanha , Suécia , Estados Unidos
5.
Lupus ; 25(8): 897-904, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27252267

RESUMO

OBJECTIVE: Antinuclear antibodies (ANA) represent a hallmark in the diagnosis of ANA-associated rheumatic diseases (AARD). However, anti-DFS70 antibodies are present in a higher portion of the healthy individuals (HI) than in patients with AARD. Consequently, we developed a novel, highly specific indirect immunofluorescence (IIF) method that blocks anti-DFS70 antibodies from binding to HEp-2 cells and to evaluate the method in a multi-center study. METHODS: A total of 18 samples from systemic lupus erythematosus patients (SLE, n = 7) and HI (n = 11) were used for the initial development of the immunoadsorption method. For the multi-center evaluation, samples with a dense fine speckled (DFS) pattern (n = 99) were collected at three different sites based on their established IIF screening procedure at the respective laboratories. Additionally, four characterized samples with established clinically relevant IIF patterns (centromere, nucleolar, speckled, homogeneous) were blended in five different ratios (10%, 25%, 50%, 75%, 90%) with a sample positive for anti-DFS70 antibodies, which by itself showed a dense fine speckled (DFS) IIF pattern. All samples were tested by IIF with NOVA Lite HEp-2 ANA and NOVA Lite HEp-2 Select on the NOVA View® instrument, and also tested by QUANTA Flash DFS70 chemiluminescent immunoassay (CIA) for confirmation of anti-DFS70 antibodies (Inova Diagnostics, San Diego, CA, USA). RESULTS: For the development of the immunoadsorption method, only 1/7 ANA-positive samples from SLE patients, but 8/10 ANA-positive samples from healthy individuals turned negative using the immunoadsorption. Subsequently, 73/99 (73.7%) of the DFS pattern samples were positive by CIA for anti-DFS70 antibodies showing a strong quantitative Spearman's correlation (rho = 0.57 (95% CI, 0.39-0.71, p < 0.0001)) between light intensity units (LIU) measured by NOVA View and CIA. Intensities measured with NOVA Lite HEp-2 and NOVA Lite HEp-2 Select demonstrated significantly lower intensity values after inhibition with DFS70 antigen (p < 0.0001). When samples were processed to mimic samples with mixed patterns (DFS + clinically relevant pattern), the new immunoadsorption method demonstrated that all clinically relevant patterns remained unchanged whereas the LIUs from NOVA View analysis significantly decreased after inhibition (p < 0.0001). CONCLUSION: The data showed that the NOVA Lite HEp-2 Select kit effectively inhibits anti-DFS70 antibody binding to its cellular target antigen.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/imunologia , Anticorpos Antinucleares/sangue , Técnica Indireta de Fluorescência para Anticorpo/métodos , Medições Luminescentes/métodos , Lúpus Eritematoso Sistêmico/imunologia , Fatores de Transcrição/imunologia , Estudos de Casos e Controles , Humanos
7.
Clin Dev Immunol ; 2013: 978202, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24376466

RESUMO

OBJECTIVE: We aimed to compare a chemiluminescent immunoassay (CIA, QUANTA Flash) on BIO-FLASH with a multiplex flow immunoassay (MFI) on BioPlex 2200 for the detection of antibodies to Ro60, Ro52, and SS-B. METHODS: The study included 241 samples, from patients suffering from systemic autoimmune diseases (n = 108) as well as disease controls (n = 133). All samples were tested for anti-Ro52, anti-Ro60, and anti-SS-B (La) antibodies on QUANTA Flash (INOVA Diagnostics, San Diego, USA) and BioPlex 2200 (Bio-Rad Laboratories Inc., Hercules, USA). Discrepant samples were tested by two independent methods: BlueDot/ANA and QUANTRIX Microarray (both D-tek, Belgium). RESULTS: The overall qualitative agreements were 95.4% (95% confidence interval, CI 92.0-97.7%) for anti-Ro52, 98.8% (95% CI 96.4-99.7%) for anti-Ro60, and 91.7% (95% CI 87.5-94.9%) for anti-SS-B antibodies. There were 34 discrepant samples among all assays (20 anti-SS-B, 11 anti-Ro52, 3 anti-Ro60). 30/33 of retested samples (by D-tek dot blot) agreed with the QUANTA Flash results. Similar findings were obtained with QUANTRIX Microarray kit. CONCLUSION: QUANTA Flash and BioPlex 2200 show good qualitative agreement. The clinical performances were similar for anti-Ro52 and anti-Ro60 autoantibodies while differences were observed for anti-SS-B (La) antibodies.


Assuntos
Autoanticorpos/imunologia , Autoantígenos/imunologia , Fluorimunoensaio/métodos , Ribonucleoproteínas/imunologia , Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Antígeno SS-B
8.
Clin Chim Acta ; 413(7-8): 719-26, 2012 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-22265712

RESUMO

BACKGROUND: The detection of anti-proteinase 3 (PR3) and anti-myeloperoxidase (MPO) autoantibodies represents a serological hallmark in the diagnosis of small vessel vasculitis such as granulomatosis with polyangiitis (GPA) and microscopic polyangiitis (MPA). We evaluated novel chemiluminescence assays (CIAs) for PR3- and MPO-ANCA detection and investigated their utility for disease activity monitoring. METHODS: Sera collected from GPA (n=41) and MPA (n=30) patients were tested by QUANTA Lite® PR-3 and MPO ELISAs (INOVA Diagnostics) and by the QUANTA Flash™ PR3 and MPO CIAs (INOVA). Precision and linearity were analyzed following reference guidelines. The recently launched reference sera for PR3-and MPO-ANCA (Centers of Disease Control and prevention, CDC) were used to establish international units for the new assays. Disease activity was determined using the Birmingham Vasculitis Activity Score. RESULTS: The international standards for PR3-and MPO-ANCA yielded results of 403 CU and 332 CU in the novel CIAs, respectively. The linearity analysis showed linear regression values>0.97 with slopes between 0.96 and 1.04. Total variation obtained from the precision study showed CV% of ≤7.4 for PR3-ANCA and ≤12.8 for MPO-ANCA. Good agreement (Spearman rho ≥ 0.89) was observed between CIA and ELISA. PR3-ANCA determined by CIA, but not by ELISA, was correlated with disease activity. No correlation was found for MPO-ANCA. CONCLUSION: The novel PR3- and MPO-ANCA CIAs show good precision, linearity and correlation to ELISA. In addition, PR3-ANCA by CIA show correlation with disease activity.


Assuntos
Autoanticorpos/sangue , Mieloblastina/imunologia , Peroxidase/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Luminescência , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA