Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Sensors (Basel) ; 22(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35214566

RESUMO

Nocturnal hypoglycemia (NH) is one of the most challenging events for multiple dose insulin therapy (MDI) in people with type 1 diabetes (T1D). The goal of this study is to design a method to reduce the incidence of NH in people with T1D under MDI therapy, providing a decision-support system and improving confidence toward self-management of the disease considering the dataset used by Bertachi et al. Different machine learning (ML) algorithms, data sources, optimization metrics and mitigation measures to predict and avoid NH events have been studied. In addition, we have designed population and personalized models and studied the generalizability of the models and the influence of physical activity (PA) on them. Obtaining 30 g of rescue carbohydrates (CHO) is the optimal value for preventing NH, so it can be asserted that this is the value with which the time under 70 mg/dL decreases the most, with almost a 35% reduction, while increasing the time in the target range by 1.3%. This study supports the feasibility of using ML techniques to address the prediction of NH in patients with T1D under MDI therapy, using continuous glucose monitoring (CGM) and a PA tracker. The results obtained prove that BG predictions can not only be critical in achieving safer diabetes management, but also assist physicians and patients to make better and safer decisions regarding insulin therapy and their day-to-day lives.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Aprendizado de Máquina
2.
Sensors (Basel) ; 21(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064157

RESUMO

The time spent in glucose ranges is a common metric in type 1 diabetes (T1D). As the time in one day is finite and limited, Compositional Data (CoDa) analysis is appropriate to deal with times spent in different glucose ranges in one day. This work proposes a CoDa approach applied to glucose profiles obtained from six T1D patients using continuous glucose monitor (CGM). Glucose profiles of 24-h and 6-h duration were categorized according to the relative interpretation of time spent in different glucose ranges, with the objective of presenting a probabilistic model of prediction of category of the next 6-h period based on the category of the previous 24-h period. A discriminant model for determining the category of the 24-h periods was obtained, achieving an average above 94% of correct classification. A probabilistic model of transition between the category of the past 24-h of glucose to the category of the future 6-h period was obtained. Results show that the approach based on CoDa is suitable for the categorization of glucose profiles giving rise to a new analysis tool. This tool could be very helpful for patients, to anticipate the occurrence of potential adverse events or undesirable variability and for physicians to assess patients' outcomes and then tailor their therapies.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia , Automonitorização da Glicemia , Análise de Dados , Diabetes Mellitus Tipo 1/diagnóstico , Glucose , Humanos , Modelos Estatísticos
3.
J Clin Endocrinol Metab ; 106(1): 55-63, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32852548

RESUMO

OBJECTIVE: To evaluate the safety and performance of a new multivariable closed-loop (MCL) glucose controller with automatic carbohydrate recommendation during and after unannounced and announced exercise in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: A randomized, 3-arm, crossover clinical trial was conducted. Participants completed a heavy aerobic exercise session including three 15-minute sets on a cycle ergometer with 5 minutes rest in between. In a randomly determined order, we compared MCL control with unannounced (CLNA) and announced (CLA) exercise to open-loop therapy (OL). Adults with T1D, insulin pump users, and those with hemoglobin (Hb)A1c between 6.0% and 8.5% were eligible. We investigated glucose control during and 3 hours after exercise. RESULTS: Ten participants (aged 40.8 ± 7.0 years; HbA1c of 7.3 ± 0.8%) participated. The use of the MCL in both closed-loop arms decreased the time spent <70 mg/dL of sensor glucose (0.0%, [0.0-16.8] and 0.0%, [0.0-19.2] vs 16.2%, [0.0-26.0], (%, [percentile 10-90]) CLNA and CLA vs OL respectively; P = 0.047, P = 0.063) and the number of hypoglycemic events when compared with OL (CLNA 4 and CLA 3 vs OL 8; P = 0.218, P = 0.250). The use of the MCL system increased the proportion of time within 70 to 180 mg/dL (87.8%, [51.1-100] and 91.9%, [58.7-100] vs 81.1%, [65.4-87.0], (%, [percentile 10-90]) CLNA and CLA vs OL respectively; P = 0.227, P = 0.039). This was achieved with the administration of similar doses of insulin and a reduced amount of carbohydrates. CONCLUSIONS: The MCL with automatic carbohydrate recommendation performed well and was safe during and after both unannounced and announced exercise, maintaining glucose mostly within the target range and reducing the risk of hypoglycemia despite a reduced amount of carbohydrate intake.Register Clinicaltrials.gov: NCT03577158.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Carboidratos da Dieta/administração & dosagem , Exercício Físico/fisiologia , Pâncreas Artificial , Adulto , Glicemia/análise , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Controle Glicêmico/instrumentação , Controle Glicêmico/métodos , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Espanha , Sugestão
4.
J Healthc Eng ; 2020: 1414597, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32399164

RESUMO

The artificial pancreas (AP) is a system intended to control blood glucose levels through automated insulin infusion, reducing the burden of subjects with type 1 diabetes to manage their condition. To increase patients' safety, some systems limit the allowed amount of insulin active in the body, known as insulin-on-board (IOB). The safety auxiliary feedback element (SAFE) layer has been designed previously to avoid overreaction of the controller and thus avoiding hypoglycemia. In this work, a new method, so-called "dynamic rule-based algorithm," is presented in order to adjust the limits of IOB in real time. The algorithm is an extension of a previously designed method which aimed to adjust the limits of IOB for a meal with 60 grams of carbohydrates (CHO). The proposed method is intended to be applied on hybrid AP systems during 24 h operation. It has been designed by combining two different strategies to set IOB limits for different situations: (1) fasting periods and (2) postprandial periods, regardless of the size of the meal. The UVa/Padova simulator is considered to assess the performance of the method, considering challenging scenarios. In silico results showed that the method is able to reduce the time spent in hypoglycemic range, improving patients' safety, which reveals the feasibility of the approach to be included in different control algorithms.


Assuntos
Algoritmos , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Insulina/uso terapêutico
5.
Sensors (Basel) ; 20(6)2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32204318

RESUMO

(1) Background: nocturnal hypoglycemia (NH) is one of the most challenging side effects of multiple doses of insulin (MDI) therapy in type 1 diabetes (T1D). This work aimed to investigate the feasibility of a machine-learning-based prediction model to anticipate NH in T1D patients on MDI. (2) Methods: ten T1D adults were studied during 12 weeks. Information regarding T1D management, continuous glucose monitoring (CGM), and from a physical activity tracker were obtained under free-living conditions at home. Supervised machine-learning algorithms were applied to the data, and prediction models were created to forecast the occurrence of NH. Individualized prediction models were generated using multilayer perceptron (MLP) and a support vector machine (SVM). (3) Results: population outcomes indicated that more than 70% of the NH may be avoided with the proposed methodology. The predictions performed by the SVM achieved the best population outcomes, with a sensitivity and specificity of 78.75% and 82.15%, respectively. (4) Conclusions: our study supports the feasibility of using ML techniques to address the prediction of nocturnal hypoglycemia in the daily life of patients with T1D on MDI, using CGM and a physical activity tracker.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Hipoglicemia/diagnóstico , Monitorização Fisiológica , Adulto , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/fisiopatologia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/sangue , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Exercício Físico/fisiologia , Feminino , Monitores de Aptidão Física , Glucose/metabolismo , Humanos , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/patologia , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Aprendizado de Máquina , Masculino , Redes Neurais de Computação , Máquina de Vetores de Suporte
6.
IEEE J Biomed Health Inform ; 24(1): 259-267, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30763250

RESUMO

The purpose of this study was to develop an algorithm that detects aerobic exercise and triggers disturbance rejection actions to prevent exercise-induced hypoglycemia. This approach can provide a solution to poor glycemic control during and after aerobic exercise, a major hindrance in the participation of exercise by patients with type 1 diabetes. This novel exercise-induced hypoglycemia reduction algorithm (EHRA) detects exercise using a threshold on a disturbance term, a parameter estimated from an augmented minimal model using an unscented Kalman filter. After detection, the EHRA triggers the following three actions: First, a carbohydrate suggestion, second, a reduction in basal insulin and the insulin-on-board maximum limit, and finally, a 30% reduction of the next insulin meal bolus. The EHRA was tested in silico using a 15-day scenario with 8 exercise sessions of 50 min at [Formula: see text] on alternating days. The EHRA was able to obtain improved results when compared to strategies with and without exercise announcement. The unannounced, announced, and EHRA strategies all obtained an overall percentage of time in range (70-180 mg/dl) of 94% and a percentage of time 70 mg/dl of 2%, 0%, and 0%, respectively. The EHRA was tested for robustness during exercise sessions of +25% and -25% intensity and results suggest that the EHRA is able to account for variability in exercise intensity, duration, and patient dynamics such as glucose uptake rate and insulin sensitivity.


Assuntos
Diabetes Mellitus Tipo 1 , Exercício Físico/fisiologia , Pâncreas Artificial , Algoritmos , Glicemia/análise , Glicemia/metabolismo , Simulação por Computador , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/fisiopatologia , Diabetes Mellitus Tipo 1/terapia , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Monitorização Fisiológica
7.
Health Informatics J ; 26(1): 703-718, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31195880

RESUMO

Tight blood glucose control reduces the risk of microvascular and macrovascular complications in patients with type 1 diabetes. However, this is very difficult due to the large intra-individual variability and other factors that affect glycaemic control. The main limiting factor to achieve strict control of glucose levels in patients on intensive insulin therapy is the risk of severe hypoglycaemia. Therefore, hypoglycaemia is the main safety problem in the treatment of type 1 diabetes, negatively affecting the quality of life of patients suffering from this disease. Decision support tools based on machine learning methods have become a viable way to enhance patient safety by anticipating adverse glycaemic events. This study proposes the application of four machine learning algorithms to tackle the problem of safety in diabetes management: (1) grammatical evolution for the mid-term continuous prediction of blood glucose levels, (2) support vector machines to predict hypoglycaemic events during postprandial periods, (3) artificial neural networks to predict hypoglycaemic episodes overnight, and (4) data mining to profile diabetes management scenarios. The proposal consists of the combination of prediction and classification capabilities of the implemented approaches. The resulting system significantly reduces the number of episodes of hypoglycaemia, improving safety and providing patients with greater confidence in decision-making.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Diabetes Mellitus Tipo 1/complicações , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Aprendizado de Máquina , Qualidade de Vida
8.
Comput Methods Programs Biomed ; 178: 175-180, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31416546

RESUMO

BACKGROUND: Diabetic patients treated with intensive insulin therapies require a tight glycemic control and may benefit from advanced tools to predict blood glucose (BG) concentration levels and hypo/hyperglycemia events. Prediction systems using machine learning techniques have mainly focused on applications for sensor augmented pump (SAP) therapy. In contrast, insulin bolus calculators that rely on BG prediction for multiple daily insulin (MDI) injections for patients under self-monitoring blood glucose (SMBG) are scarce because of insufficient data sources and limited prediction capability of forecasting models. METHODS: We trained individualized models that can predict postprandial hypoglycemia via different machine learning algorithms using retrospective data from 10 real patients. In addition, we designed and tested a hypoglycemia reduction strategy for a similar in silico population. The system generates a bolus reduction suggestion as the scaled weighted sum of the predictions. We evaluated the general and postprandial glycemic outcomes of the in silico population to assess the systems capability of avoiding hypoglycemias. RESULTS: The median [IQR] sensitivity and specificity for hypoglycemia cases where the BG level was below 70 mg/dL were 0.49 [0.2-0.5] and 0.74 [0.7-0.9], respectively. For hypoglycemia cases where the BG level was below 54 mg/dL, the median [IQR] sensitivity and specificity were 0.51 [0.4-0.6] and 0.74 [0.7-0.8], respectively. CONCLUSIONS: The results indicated a decrease of 37% in the median number of postprandial hypoglycemias median decrease of 44% for hypoglycemias of 70 mg/dL and 54 mg/dL, respectively. This dramatic reduction makes this method a good candidate to be integrated into any Decision Support System for diabetes management.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Hipoglicemia/sangue , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Aprendizado de Máquina , Adulto , Algoritmos , Teorema de Bayes , Glicemia , Capilares/patologia , Simulação por Computador , Reações Falso-Positivas , Feminino , Humanos , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Masculino , Pessoa de Meia-Idade , Distribuição Normal , Período Pós-Prandial , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Stat Methods Med Res ; 28(12): 3550-3567, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30380996

RESUMO

The aim of this study was to apply a methodology based on compositional data analysis (CoDA) to categorise glucose profiles obtained from continuous glucose monitoring systems. The methodology proposed considers complete daily glucose profiles obtained from six patients with type 1 diabetes (T1D) who had their glucose monitored for eight weeks. The glucose profiles were distributed into the time spent in six different ranges. The time in one day is finite and limited to 24 h, and the times spent in each of these different ranges are co-dependent and carry only relative information; therefore, CoDA is applied to these profiles. A K-means algorithm was applied to the coordinates obtained from the CoDA to obtain different patterns of days for each patient. Groups of days with relatively high time in the hypo and/or hyperglycaemic ranges and with different glucose variability were observed. Using CoDA of time in different ranges, individual glucose profiles were categorised into groups of days, which can be used by physicians to detect the different conditions of patients and personalise patient's insulin therapy according to each group. This approach can be useful to assist physicians and patients in managing the day-to-day variability that hinders glycaemic control.


Assuntos
Glicemia/análise , Análise de Dados , Algoritmos , Sistemas de Apoio a Decisões Clínicas , Diabetes Mellitus Tipo 1 , Humanos
10.
Diabetes Technol Ther ; 20(4): 285-295, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29608335

RESUMO

BACKGROUND: Moderate physical activity improves overall health conditions in subjects with type 1 diabetes. However, insulin management during and after exercise is challenging due to the effects of exercise on glycemic control. Artificial pancreas (AP) systems aim to automatically control blood glucose levels, but exercise-induced hypoglycemia is a major challenge for these systems, especially in uni-hormonal configurations. The aim of this work was to evaluate the ability of several feed-forward (FF) actions to prevent exercise-induced hypoglycemia in a closed-loop setting. METHODS: A closed-loop control algorithm combined with FF actions aimed at eliminating exercise-induced hypoglycemia was evaluated in silico using the UVa/Padova type 1 diabetes simulator. The simulator was modified with an exercise model fitted to clinical data. The FF actions were evaluated in two scenarios: (1) exercise sessions during postprandial period and (2) exercise sessions during fasting period. RESULTS: The mitigation methods proposed in this work were able to minimize the occurrence of hypoglycemic events related with exercise in both scenarios. The time spent in hypoglycemic range in the 2-h period after exercise decreased from 33.3% to 0.0% (P < 0.01) and from 41.3% to 0.0% (P < 0.01) in both scenarios tested. Besides that, the occurrence of hypoglycemic events after exercise sessions was also reduced. CONCLUSIONS: The combination of the FF actions presented in this article within an AP system showed to be an effective strategy to mitigate the risk of hypoglycemia in front of aerobic exercise.


Assuntos
Simulação por Computador , Exercício Físico/fisiologia , Hipoglicemia/prevenção & controle , Modelos Biológicos , Pâncreas Artificial , Algoritmos , Humanos , Hipoglicemia/etiologia , Hipoglicemia/fisiopatologia , Medição de Risco
11.
Biosensors (Basel) ; 8(1)2018 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-29522429

RESUMO

Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes management as well as for CGM systems. In this work, the accuracy of CGM in the context of exercise is addressed. Six adults performed aerobic and anaerobic exercise sessions and used two Medtronic Paradigm Enlite-2 sensors under closed-loop therapy. CGM readings were compared with plasma glucose during different periods: one hour before exercise, during exercise, and four hours after the end of exercise. In aerobic sessions, the median absolute relative difference (MARD) increased from 9.5% before the beginning of exercise to 16.5% during exercise (p < 0.001), and then decreased to 9.3% in the first hour after the end of exercise (p < 0.001). For the anaerobic sessions, the MARD before exercise was 15.5% and increased without statistical significance to 16.8% during exercise realisation (p = 0.993), and then decreased to 12.7% in the first hour after the cessation of anaerobic activities (p = 0.095). Results indicate that CGM might present lower accuracy during aerobic exercise, but return to regular operation a few hours after exercise cessation. No significant impact for anaerobic exercise was found.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Exercício Físico , Adulto , Automonitorização da Glicemia , Feminino , Humanos , Masculino
12.
Endocrinol Diabetes Nutr (Engl Ed) ; 65(6): 342-347, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29483036

RESUMO

AIM: To assess an artificial pancreas system during aerobic (AeE) and anaerobic exercise (AnE). METHODS: A pilot clinical trial on five subjects with type 1 diabetes (4 males) aged 37±10.9 years, diabetes diagnosed 21.2±12.2 years before, insulin pump users, and with a mean HbA1c level of 7.8±0.5%. Every subject did three AeE and three AnE sessions. Blood glucose levels were monitored by the artificial pancreas system during exercise and up to four hours later. Before the start of exercise, 23g of carbohydrates were administered orally. RESULTS: The mean glucose level was 124.0±25.1mg/dL in the AeE studies and 152.1±34.1mg/dL in the AnE studies. Percent times in the different glucose ranges of 70-180, >180 and <70mg/dL were 89.8±18.6% and 75.9±27.6%; 7.7±18.4% and 23.2±28.0%; and 2.5±6.3% and 1.0±3.6% during the AeE and AnE sessions, respectively. Only six rescues with carbohydrates (15g) were required during the studies (4 in AeE and 2 in AnE). Total insulin dose during the five hours of the study was 3.1±1.0IU in the AeE studies and 3.5±1.3IU in the AnE studies. CONCLUSIONS: Blood glucose response to AeE and AnE exercise is different. The evaluated artificial pancreas system appeared to achieve effective and safe blood glucose control during exercise and up to four hours later. However, new control strategies that minimize patient intervention should be designed.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Exercício Físico , Pâncreas Artificial , Adulto , Automonitorização da Glicemia , Feminino , Humanos , Masculino
13.
Endocrinol Diabetes Nutr (Engl Ed) ; 65(3): 172-181, 2018 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29279252

RESUMO

Since the 2000s, research teams worldwide have been working to develop closed-loop (CL) systems able to automatically control blood glucose (BG) levels in patients with type 1 diabetes. This emerging technology is known as artificial pancreas (AP), and its first commercial version just arrived in the market. The main objective of this paper is to present an extensive review of the clinical trials conducted since 2011, which tested various implementations of the AP for different durations under varying conditions. A comprehensive table that contains key information from the selected publications is provided, and the main challenges in AP development and the mitigation strategies used are discussed. The development timelines for different AP systems are also included, highlighting the main evolutions over the clinical trials for each system.


Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Pâncreas Artificial , Automação , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Ensaios Clínicos como Assunto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Desenho de Equipamento , Exercício Físico , Previsões , Humanos , Hiperglicemia/sangue , Hiperglicemia/tratamento farmacológico , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Bombas de Infusão Implantáveis , Insulina/administração & dosagem , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
14.
J Diabetes Sci Technol ; 11(6): 1089-1095, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28633537

RESUMO

BACKGROUND: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. METHODS: We performed an extensive analysis of sensor's performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. RESULTS: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2 ± 8.6% in euglycemic range and 9.3 ± 9.3% in hyperglycemic range). The overall MARD was 12.1 ± 8.2%. We have also observed lower MARD for rates of change between 0 and 2 mg/dl. In CL therapy, the 10 trials with the best sensor spent less time in hypoglycemia (PG < 70 mg/dl) than the 10 trials with the worst sensors (2 ± 7 minutes vs 32 ± 38 minutes, respectively). CONCLUSIONS: In terms of accuracy, our results resemble to previously reported. Furthermore, our results showed that sensors with the lowest MARD spent less time in hypoglycemic range, indicating that the performance of CL algorithm to control PP was related to sensor accuracy.


Assuntos
Automonitorização da Glicemia , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Período Pós-Prandial , Adulto , Algoritmos , Biomarcadores/sangue , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Transdutores , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA