Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
J Clin Med ; 13(16)2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39200913

RESUMO

Fabry disease (FD) is an X-linked lysosomal storage disorder which leads to the accumulation of globotriaosylceramide (Gb3) in various organs, including the heart. FD can be subdivided into classic disease resulting from negligible residual enzyme activity and a milder, atypical phenotype with later onset and less severe clinical presentation. The use of multimodality cardiac imaging including echocardiography, cardiac magnetic resonance and nuclear imaging is important for the diagnostic and prognostic evaluation in these patients. There are gaps in the literature regarding the comprehensive description of cardiac findings of FD and its evaluation by multimodality imaging. In this review, we describe the contemporary practices and roles of multimodality cardiac imaging in individuals affected with Fabry disease.

3.
J Interv Card Electrophysiol ; 67(2): 319-328, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37392273

RESUMO

BACKGROUND: Adults with congenital heart disease (ACHD) have increased risk of arrhythmias warranting implantation of cardiac implantable electronic devices (CIEDs), which may parallel the observed increase in survival of ACHD patients over the past few decades. We sought to characterize the trends and outcomes of CIED implantation in the inpatient ACHD population across US from 2005 to 2019. METHODS: A retrospective analysis of the Nationwide Inpatient Sample (NIS) identified 1,599,519 unique inpatient ACHD admissions (stratified as simple (85.1%), moderate (11.5%), and complex (3.4%)) using the International Classification of Diseases 9/10-CM codes. Hospitalizations for CIED implantation (pacemaker, ICD, CRT-p/CRT-d) were identified and the trends analyzed using regression analysis (2-tailed p < 0.05 was considered significant). RESULTS: A significant decrease in the hospitalizations for CIED implantation across the study period [3.3 (2.9-3.8)% in 2005 vs 2.4 (2.1-2.6)% in 2019, p < 0.001] was observed across all types of devices and CHD severities. Pacemaker implantation increased with each age decade, whereas ICD implantation rates decreased over 70 years of age. Complex ACHD patients receiving CIED were younger with a lower prevalence of age-related comorbidities, however, had a greater prevalence of atrial/ventricular tachyarrhythmias and complete heart block. The observed inpatient mortality rate was 1.2%. CONCLUSIONS: In a nationwide analysis, we report a significant decline in CIED implantation between 2005 and 2019 in ACHD patients. This may either be due to a greater proportion of hospitalizations resulting from other complications of ACHD or reflect a declining need for CIED due to advances in medical/surgical therapies. Future prospective studies are needed to elucidate this trend further.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA