Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Biofabrication ; 15(2)2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36689776

RESUMO

Three-dimensional (3D) bioprinting is an emerging technology, which turned out to be an optimal tool for tissue engineering approaches. To date, different printing systems have been developed. Among them, the extrusion-based approach demonstrated to be the most suitable for skeletal muscle tissue engineering, due to its ability to produce and deposit printing fibers in a parallel pattern that well mimic the native skeletal muscle tissue architecture. In tissue bioengineering, a key role is played by biomaterials, which must possess the key requisite of 'printability'. Nevertheless, this feature is not often well correlated with cell requirements, such as motives for cellular adhesion and/or absorbability. To overcome this hurdle, several efforts have been made to obtain an effective bioink by combining two different biomaterials in order to reach a good printability besides a suitable biological activity. However, despite being efficient, this strategy reveals several outcomes limitations. We report here the development and characterization of a novel extrusion-based 3D bioprinting system, and its application for correction of volumetric muscle loss (VML) injury in a mouse model. The developed bioprinting system is based on the use of PEG-Fibrinogen, a unique biomaterial with excellent biocompatibility, well-suited for skeletal muscle tissue engineering. With this approach, we obtained highly organized 3D constructs, in which murine muscle progenitors were able to differentiate into muscle fibers arranged in aligned bundles and capable of spontaneously contracting when culturedin vitro. Furthermore, to evaluate the potential of the developed system in future regenerative medicine applications, bioprinted constructs laden with either murine or human muscle progenitors were transplanted to regenerate theTibialis Anteriormuscle of a VML murine model, one month after grafting.


Assuntos
Bioimpressão , Engenharia Tecidual , Camundongos , Humanos , Animais , Engenharia Tecidual/métodos , Alicerces Teciduais , Bioimpressão/métodos , Impressão Tridimensional , Músculo Esquelético , Materiais Biocompatíveis
5.
ESMO Open ; 6(3): 100170, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34090171

RESUMO

Epithelioid hemangioendothelioma (EHE) is an ultra-rare, translocated, vascular sarcoma. EHE clinical behavior is variable, ranging from that of a low-grade malignancy to that of a high-grade sarcoma and it is marked by a high propensity for systemic involvement. No active systemic agents are currently approved specifically for EHE, which is typically refractory to the antitumor drugs used in sarcomas. The degree of uncertainty in selecting the most appropriate therapy for EHE patients and the lack of guidelines on the clinical management of the disease make the adoption of new treatments inconsistent across the world, resulting in suboptimal outcomes for many EHE patients. To address the shortcoming, a global consensus meeting was organized in December 2020 under the umbrella of the European Society for Medical Oncology (ESMO) involving >80 experts from several disciplines from Europe, North America and Asia, together with a patient representative from the EHE Group, a global, disease-specific patient advocacy group, and Sarcoma Patient EuroNet (SPAEN). The meeting was aimed at defining, by consensus, evidence-based best practices for the optimal approach to primary and metastatic EHE. The consensus achieved during that meeting is the subject of the present publication.


Assuntos
Hemangioendotelioma Epitelioide , Sarcoma , Adulto , Criança , Consenso , Hemangioendotelioma Epitelioide/diagnóstico , Hemangioendotelioma Epitelioide/tratamento farmacológico , Humanos , Oncologia , Defesa do Paciente , Sarcoma/diagnóstico , Sarcoma/tratamento farmacológico
7.
Ann Oncol ; 29(Suppl 4): iv79-iv95, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30285218
8.
Eur Rev Med Pharmacol Sci ; 22(17): 5438-5446, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30229814

RESUMO

OBJECTIVE: The purpose of this study is to verify the effectiveness and complications occurrence of radiofrequency ablation (RFA) in the treatment of osteoid osteoma (OO) in non-operating room anesthesia (N.O.R.A.). PATIENTS AND METHODS: From 2014 to 2017, 61 patients affected by OO (40 men and 21 women) with an age of 20.7 years on average (range, 4-51 years; 12 patients aged 20 years or younger) underwent computed tomography-guided percutaneous radiofrequency ablation (RFA) in N.O.R.A. (Non-Operating Room Anesthesia). Lesion sites treated were: femur (27), tibia (22), pelvis (2), talar bone (3), distal radius (1), and humerus (6). Mean follow-up time was 36 months. In each case, anesthesiologic support followed a new protocol (N.O.R.A. protocol), approved by our Institute. Primary success rate, complications, symptom-free intervals, and follow-up results were evaluated. RESULTS: Pain relief (evaluated with Visual Analogue Scale - VAS) was significant in 97% of patients; it disappeared within 24 hours of the procedure in 44 patients, within 3 days in 10 patients, and within 7 days in 7 patients. After 6 months of observation time, 60 of 61 patients were successfully treated and had no more complaints. In 2 patients, two major complications were found: infection of the site treated, healed with antibiotics, and a nerve lesion, healed with steroid therapy. No other complications were observed. CONCLUSIONS: RFA is a highly effective, efficient, minimally invasive and safe method for the treatment of OO following N.O.R.A.


Assuntos
Anestesia Local/métodos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Osteoma Osteoide/diagnóstico por imagem , Osteoma Osteoide/cirurgia , Ablação por Radiofrequência/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Manejo da Dor/métodos , Resultado do Tratamento , Adulto Jovem
10.
Injury ; 49(8): 1612-1616, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29903579

RESUMO

INTRODUCTION: Core biopsy is today recognized as the gold standard for the diagnosis of bone lesions; unfortunately, when the bone is too solid it can be very difficult to penetrate it; in case of failure, open biopsy is indicated but it is associated with greater contamination and complications. A possible solution is to connect a common orthopedic drill to the core biopsy needle. The aim of the presenting study was to present a technique useful for performing biopsies in case of very strong bone lesions and to evaluate the adequacy and quality of the obtained specimen. MATERIALS AND METHODS: A standard bone biopsy set was connected to a commercial drill to perform bone biopsies. Data was collected over a 2-year period (2015-2016). Information regarding technical success, diagnostic data and complication rates was all collated to assess the technical feasibility of this technique. RESULTS: Out of 357 bone biopsies, 34 patients underwent the procedure using a common orthopedic drill connected to a core biopsy needle. Diagnostic material was obtained in each patient and the artifacts were considered irrelevant. No major complications occurred in any patient. DISCUSSION: The use of a core biopsy needle connected to a common orthopedic drill facilitates the penetration of thick cortical bone by simply applying continuous speed and pressure; nevertheless, the biopsy needle we use is not designed for a drilling procedure and for this reason it can be damaged, but if the biopsy is performed with particular attention, the mechanical failure can be avoided CONCLUSIONS: Bone biopsy using a commercial hand drill has a technically high success rate with minimal complications. Further studies with more cases are necessary to verify our results.


Assuntos
Biópsia com Agulha de Grande Calibre , Neoplasias Ósseas/patologia , Osso e Ossos/patologia , Equipamentos Ortopédicos , Adolescente , Adulto , Artefatos , Biópsia com Agulha de Grande Calibre/instrumentação , Neoplasias Ósseas/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Adulto Jovem
11.
Ann Oncol ; 29(Suppl 4): iv51-iv67, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29846498
12.
Ann Oncol ; 29(Suppl 4): iv68-iv78, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29846513
13.
J Biol Regul Homeost Agents ; 28(1): 65-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24750792

RESUMO

The objective is to reconstruct the subchondral bone after curettage of benign tumors located in the epiphysis, a relevant topic in oncological orthopedics. Several bones substituted are commercially available, yet none of these are suitably moldable to repair or be placed in the bone defect; although autologous bone for little defects and homologous for bigger defects are still considered the standard in reconstruction, we verify the ability to adapt and support articular cartilage through the application of Plexur M (Registered Trademark), a newly engineered biomaterial bone. In the present study, we enrolled the first ten consecutive cases referred to our department, where patients were affected by a benign epiphyseal tumor destroying the subchondral bone through to the articular cartilage. Every patient underwent curettage of the disease, apposition of a newly engineered biomaterial bone and filling with homologous morselized bone. The quality of reconstruction was evaluated by two surgeons and by a radiologist based on the achievement of surgical objectives and comparing pre and postoperative imaging. In seven out of eight cases of lesions located in the lower limbs the quality of reconstruction was considered good, restoring an adequate support to the articular cartilage. The quality of the remaining case was considered poor probably due to the extent of the spread of the disease, which destroyed the entire proximal tibial epiphysis. In the two cases where the disease was located in the upper limbs, the Plexur M application restored support to the articular cartilage sufficiently well. However, in the case of a giant cell tumor of the distal radial epiphysis there was a slight reabsorption of the morselized homologous bone. Our series suggest that Plexur M should be considered a valid option for orthopedic surgeons in restoring adequate mechanical support to the articular cartilage; nevertheless, considering its high cost, its use might be reserved to selected cases until further studies can verify the integration process, the effects on the survival of the articular cartilage and on the prevention of premature osteoarthritis.


Assuntos
Neoplasias Ósseas/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Engenharia Tecidual , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos
14.
Orthop Traumatol Surg Res ; 99(7): 875-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24074762

RESUMO

Peripheral chondrosarcoma is a rare tumor particularly insidious when arising from the pelvis, becoming symptomatic later in time when surgery may be too difficult and dangerous due to this complex area. In the present case, the tumor arose from an exostosis located on the medial surface of the left iliac wing. Its diameter was 25 cm × 20 cm × 15 cm, adhering to the last three vertebrae, involving the left iliac vein and artery, displacing the left ureter. In a similar case, a hindquarter amputation is indicated but, if the patient refuses, a resection remains possible. In this paper, we describe a multistage technique consisting of an extra-anatomic vascular bypass, a lumbar stabilization, a neurovascular bundles anterior isolation and a postero-lateral resection of this mass. After a five-year follow-up, the patient is alive and able to stand and walk with support, after undergoing twice lung metastasis removal.


Assuntos
Neoplasias Ósseas/cirurgia , Parafusos Ósseos , Condrossarcoma/cirurgia , Vértebras Lombares/cirurgia , Ossos Pélvicos , Sacro/cirurgia , Fusão Vertebral/métodos , Angiografia , Biópsia por Agulha , Neoplasias Ósseas/irrigação sanguínea , Neoplasias Ósseas/diagnóstico , Condrossarcoma/irrigação sanguínea , Condrossarcoma/diagnóstico , Artéria Femoral/diagnóstico por imagem , Seguimentos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
16.
Lupus ; 19(14): 1614-22, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20937624

RESUMO

Elevated serum IgE has been described in systemic lupus erythematosus (SLE), but associations with disease risk and characteristics remain unresolved. We assessed total serum IgE levels and atopy (IgE > 100 IU/ml) in recently diagnosed SLE patients (n = 228) compared with population controls (n = 293) and in relation to disease activity, autoantibodies, clinical features, total immunoglobulins, C-reactive protein, and allergy history. Multivariate models estimated determinants of IgE and atopy in patients and controls, and associations of SLE with allergy and atopy. Total IgE levels were higher in patients than controls (median = 42 vs. 29 IU/ml); 32% of patients and 25% of controls were atopic (p = 0.06). IgE levels were significantly higher in non-Whites and patients reporting childhood onset (<18 years) asthma and hives, and in controls reporting childhood asthma, hay fever, eczema, and adult onset hives. After accounting for racial differences, atopy was not associated with SLE, nephritis, or other clinical and laboratory parameters. In sum, our findings provide limited evidence of a direct association between total serum IgE and SLE overall or with other disease characteristics after adjusting for demographic characteristics and allergy history. Future studies may want to explore potentially shared risk factors for development of allergy, atopy, and SLE.


Assuntos
Hipersensibilidade/imunologia , Imunoglobulina E/sangue , Lúpus Eritematoso Sistêmico/imunologia , Adolescente , Adulto , Idade de Início , Autoanticorpos/imunologia , Proteína C-Reativa/metabolismo , Estudos de Casos e Controles , Feminino , Humanos , Hipersensibilidade/epidemiologia , Nefrite Lúpica , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
17.
Clin Exp Allergy ; 37(9): 1349-56, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17845416

RESUMO

BACKGROUND: Long-term avoidance of natural rubber latex [Hevea brasiliensis (Hev b)] is currently recommended for health-care workers (HCWs) with established natural rubber latex (NRL) allergy. Percutaneous sensitivity to eight Hev b NRL allergens was evaluated in HCWs in 2000. To date, no studies have evaluated the longitudinal effects of NRL avoidance on percutaneous sensitivity to NRL allergens. OBJECTIVE: The aims of this study were to evaluate changes in percutaneous reactivity to non-ammoniated latex (NAL) and NRL allergens in HCWs 5 years after a recommendation to avoid NRL and to evaluate factors that predict the persistence of in vivo sensitivity to NAL and NRL allergens. METHODS: Skin prick testing was performed with NAL, seven NRL allergens (Hev b 1, 2, 3, 4, 6.01, 7.01, and 13), and recombinant Hev b 5 (rHev b 5) in 34 HCWs who were initially evaluated in 2000 for occupationally related NRL allergy. Serial 10-fold dilutions of NAL and NRL allergens were employed in skin testing. Sera from the HCWs were assayed for latex and enhanced latex (rHev b 5-enriched allergosorbent)-specific IgE antibodies using the ImmunoCAP assay. RESULTS: The prevalence of work-related symptoms significantly decreased between 2000 and 2005 with avoidance of NRL (P<0.05). A >/=100-fold reduction in percutaneous sensitivity to Hev b 2 and Hev b 7 was less likely in those with prior history of systemic reactions to NRL (P=0.0053), reported history of reaction to cross-reactive foods (P=0.014), continued local reactions to NRL gloves (P<0.0001), or high NRL glove exposure since the initial study (P=0.0075). The diagnostic sensitivity and specificity of the latex-specific IgE serology was 54% and 87.5%, respectively, in comparison with NAL skin tests. The addition of rHev b 5 to the ImmunoCAP (enhanced latex) allergosorbent altered the diagnostic sensitivity and specificity of the ImmunoCAP to 77% and 75%, respectively. CONCLUSION: While symptoms may resolve quickly with NRL avoidance therapy, detectable IgE indicating continued sensitization remains beyond 5 years, and thus continued avoidance of NRL should be recommended.


Assuntos
Hevea/imunologia , Hipersensibilidade ao Látex/diagnóstico , Látex/imunologia , Exposição Ocupacional/efeitos adversos , Borracha/efeitos adversos , Adulto , Idoso , Feminino , Pessoal de Saúde , Humanos , Imunoglobulina E/sangue , Hipersensibilidade ao Látex/epidemiologia , Hipersensibilidade ao Látex/imunologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Sensibilidade e Especificidade , Testes Cutâneos , Fatores de Tempo
18.
Clin Exp Allergy ; 36(8): 1078-86, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16911364

RESUMO

BACKGROUND: Hevea brasiliensis latex serum is commonly used as the in vivo and in vitro reference antigen for latex allergy diagnosis as it contains the full complement of latex allergens. OBJECTIVE: This study quantifies the concentrations of the significant allergens in latex serum and examines its suitability as an antigen source in latex allergy diagnosis and immunotherapy. METHODS: The serum phase was extracted from centrifuged latex that was repeatedly freeze-thawed or glycerinated. Quantitation of latex allergens was performed by two-site immunoenzymetric assays. The abundance of RNA transcripts of the latex allergens was estimated from the number of their clones in an Expressed Sequence Tags library. RESULTS: The latex allergens, Hev b 1, 2, 3, 4, 5, 6, 7 and 13, were detected in freeze-thawed and glycerinated latex serum at levels ranging from 75 (Hev b 6) to 0.06 nmol/mg total proteins (Hev b 4). Hev b 6 content in the latex was up to a thousand times higher than the other seven latex allergens, depending on source and/or preparation procedure. Allergen concentration was reflected in the abundance of mRNA transcripts. When used as the antigen, latex serum may bias the outcome of latex allergy diagnostic tests towards sensitization to Hev b 6. Tests that make use of latex serum may fail to detect latex-specific IgE reactivity in subjects who are sensitized only to allergens that are present at low concentrations. CONCLUSION: Latex allergy diagnostics and immunotherapy that use whole latex serum as the antigen source may not be optimal because of the marked imbalance of its constituent allergens.


Assuntos
Alérgenos/análise , Hevea , Hipersensibilidade ao Látex/diagnóstico , Proteínas de Plantas/imunologia , Borracha/química , Alérgenos/genética , Alérgenos/imunologia , Antígenos de Plantas/análise , Antígenos de Plantas/genética , Antígenos de Plantas/imunologia , Etiquetas de Sequências Expressas , Biblioteca Gênica , Humanos , Imunoglobulina E/sangue , Hipersensibilidade ao Látex/imunologia , Fosfolipases/análise , Fosfolipases/genética , Fosfolipases/imunologia , Proteínas de Plantas/análise , Proteínas de Plantas/genética , RNA Mensageiro/análise , Sensibilidade e Especificidade , Testes Cutâneos
19.
Anal Bioanal Chem ; 382(4): 1027-34, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15931499

RESUMO

Select Agents are defined by CDC and the USDA Animal and Plant Health Inspection Service (APHIS) as biological agents or toxins deemed a threat to public, animal, or plant health, or to animal or plant products. They are classified on the basis of their ease of dissemination, mortality/morbidity rate, and potential for social disruption. A subset of these agents includes Bacillus anthracis, Yersinia pestis, Francisella tularensis, ricin toxin (RT), and staphylococcal enterotoxin B (SEB). Infection or intoxication with these agents has been shown to elicit an antigen-specific serum IgG response. We describe a fluorescent covalent microsphere immunoassay (FCMIA) for measurement of specific IgG antibodies to seven different antigens from five different select agents; B. anthracis [protective antigen (PA) and lethal factor (LF)], Y. pestis (F1 and V antigens), F. tularensis, RT and SEB simultaneously in human B. anthracis vaccinee sera (containing anti-PA and anti-LF IgG) which had been spiked with animal specific IgG antibodies to the other select agents. Inter-assay and intra-assay coefficients of variation were 6.5 and 13.4%, respectively (N = 4). There were no significant differences (P > 0.70) between assay responses when the assays were performed individually or multiplexed. When the observed versus expected interpolated concentrations were compared, highly linear relationships were observed (r2 values from 0.981 to 0.999, P < 0.001). Minimum detectable concentrations (MDC) ranged from 0.3 ng mL(-1) (Y. pestis F1) to 300 ng mL(-1) (RT). Finally, the curves showed responses were linear for most analytes from their MDC to 125 (SEB) to 1,300 (Y. pestis F1) x their MDC. These data indicate that multiplexed FCMIA is a sensitive and accurate method for simultaneous measurement of specific IgG in serum to CDC select agents and may be of value in screening either decontamination workers or the general population for exposure to/infection with these agents.


Assuntos
Bacillus anthracis/imunologia , Enterotoxinas/imunologia , Francisella tularensis/imunologia , Imunoglobulina G , Ricina/imunologia , Yersinia pestis/imunologia , Animais , Anticorpos Antibacterianos/análise , Anticorpos Antibacterianos/imunologia , Reações Antígeno-Anticorpo , Antígenos de Bactérias/análise , Antígenos de Bactérias/imunologia , Fluorimunoensaio/métodos , Humanos , Imunoglobulina G/análise , Imunoglobulina G/imunologia , Microesferas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Occup Environ Med ; 61(8): 703-8, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15258278

RESUMO

AIMS: To evaluate potential exposure to Bacillis anthracis (Ba) spores in sampling/decontamination workers in the aftermath of an anthrax terror attack. METHODS: Fifty six serum samples were obtained from workers involved in environmental sampling for Ba spores at the American Media, Inc. (AMI) building in Boca Raton, FL after the anthrax attack there in October 2001. Nineteen sera were drawn from individuals both pre-entry and several weeks after entrance into the building. Nine sera each were drawn from unique individuals at the pre-entry and follow up blood draws. Thirteen donor control sera were also evaluated. Individuals were surveyed for Ba exposure by measurement of serum Ba anti-protective antigen (PA) specific IgG antibodies using a newly developed fluorescent covalent microsphere immunoassay (FCMIA). RESULTS: Four sera gave positive anti-PA IgG results (defined as anti-PA IgG concentrations > or = the mean microg/ml anti-PA IgG from donor control sera (n = 13 plus 2 SD which were also inhibited > or = 85% when the serum was pre-adsorbed with PA). The positive sera were the pre-entry and follow up samples of two workers who had received their last dose of anthrax vaccine in 2000. CONCLUSION: It appears that the sampling/decontamination workers of the present study either had insufficient exposure to Ba spores to cause the production of anti-PA IgG antibodies or they were exposed to anthrax spores without producing antibody. The FCMIA appears to be a fast, sensitive, accurate, and precise method for the measurement of anti-PA IgG antibodies.


Assuntos
Anticorpos Antibacterianos/sangue , Antígenos de Bactérias/imunologia , Bacillus anthracis/imunologia , Bioterrorismo , Imunoglobulina G/sangue , Exposição Ocupacional/efeitos adversos , Adulto , Descontaminação/métodos , Monitoramento Ambiental/métodos , Florida , Fluorescência , Humanos , Imunoensaio/métodos , Microesferas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA