Clin Orthop Relat Res ; (248): 21-5; discussion 25-6, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2805481

RESUMO

Successful posterior cruciate ligament-sparing total knee arthroplasty functions in an equivalent fashion to a contralateral normal limb during the mechanical stresses of stair ascent and descent. Motion and force plate analysis reveal highly symmetric gait patterns. Sagittal angles are greater than previously reported for the total condylar prosthesis and are nearly equal to those recorded for the age-matched normal population.


Assuntos
Marcha , Prótese do Joelho , Idoso , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Ligamentos Articulares/fisiologia , Masculino , Movimento , Desenho de Prótese , Estresse Mecânico
2.
J Orthop Res ; 7(5): 732-7, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2760746

RESUMO

The purpose of this study was to determine whether surface and internal fine-wire electromyography electrodes had an effect on gait. The subjects for the experiments were 38 children with the spastic diplegic type of cerebral palsy. The children were filmed using the high-speed cinematographic technique while they walked (a) with no electrodes (unencumbered), (b) with only surface electrodes, and (c) with internal electrodes. Single stance time, step length, cadence, and walking velocity were compared with analysis of variance and Bonferroni t tests. The results included a significant decrease in cadence (-6.3% of unencumbered walking; p less than 0.05) when comparing walking with surface electrodes with walking without any electrodes. The internal electrodes caused significant decreases from normal walking in the following parameters: step length for both the measured leg (-18.6%; p less than 0.005) and the nonmeasured leg (-18.0%; p less than 0.005), cadence (-7.9%; p less than 0.02), and walking velocity (-23.5%; p less than 0.005). Internal electrodes caused significant decreases as compared with surface electrodes in the step length for both the measured leg (15.7%; p less than 0.01) and the nonmeasured leg (15.6%; p less than 0.005) and walking velocity (19.7%; p less than 0.005). Single stance phase did not change significantly in any of the comparisons. It appears that the addition of the surface electrode apparatus does change the normal gait of a subject, causing a large decrease in cadence. The measurement of gait with internal electrodes causes further change in gait, resulting in large decreases in step length and walking velocity.(ABSTRACT TRUNCATED AT 250 WORDS)