Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Ann Vasc Surg ; 108: 84-91, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942373

RESUMO

BACKGROUND: Our objective is twofold: determining if simulation allows residents to reach proficient surgeons' performance concerning fundamental technical skills of endovascular surgery (FEVS) while investigating effects of the program on surgeons' stress. METHODS: Using a FEVS training simulator, 8 endovascular FEVS were performed by vascular surgery residents (simulator-naive or simulator-experienced residents [SER]) and seniors. Total time needed to complete the 8 tasks, called total completion time (TCT), was the main evaluation criterion. Analgesia Nociception Index (ANI) was monitored during simulation. Likert scale questionnaire was filled out after each simulation. RESULTS: For each task, TCT was significantly lower for SER and seniors than simulator-naive residents (P = 0.0163). After only 5 simulations, SER were able to reach and even exceed the seniors' level in terms of TCT, with a median time of 10.8 min for SER and 11.9 min for seniors, and wire's movements with a median distance during cannulation of 4.44 m for SER and 4.17 m for seniors. Seniors remained better than SER in terms of precise wire manipulation (wire movement after cannulation), 4.17 m against 4.44 m (3.72-5.96), respectively. Based on the Likert scale stress analysis, seniors felt less stressed than both residents' groups (P = 0.0618). Seniors' initial ANI and mean ANI over the session were significantly lower than those of the residents, P = 0.0358 and P = 0.0250, respectively. CONCLUSIONS: We showed that 5 simulation sessions allowed residents to reach experienced surgeons' capacities on FEVS concerning TCT. Subjectively, seniors felt less stressed than residents, contrary to the results of our objective measures of stress.

2.
J Cardiovasc Dev Dis ; 11(6)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38921681

RESUMO

BACKGROUND: Extracellular volume fraction (ECV), measured with contrast-enhanced magnetic resonance imaging (CE-MRI), has been utilized to study myocardial fibrosis, but its role in peripheral artery disease (PAD) remains unknown. We hypothesized that T1 mapping and ECV differ between PAD patients and matched controls. METHODS AND RESULTS: A total of 37 individuals (18 PAD patients and 19 matched controls) underwent 3.0T CE-MRI. Skeletal calf muscle T1 mapping was performed before and after gadolinium contrast with a motion-corrected modified look-locker inversion recovery (MOLLI) pulse sequence. T1 values were calculated with a three-parameter Levenberg-Marquardt curve fitting algorithm. ECV and T1 maps were quantified in five calf muscle compartments (anterior [AM], lateral [LM], and deep posterior [DM] muscle groups; soleus [SM] and gastrocnemius [GM] muscles). Averaged peak blood pool T1 values were obtained from the posterior and anterior tibialis and peroneal arteries. T1 values and ECV are heterogeneous across calf muscle compartments. Native peak T1 values of the AM, LM, and DM were significantly higher in PAD patients compared to controls (all p < 0.028). ECVs of the AM and SM were significantly higher in PAD patients compared to controls (AM: 26.4% (21.2, 31.6) vs. 17.3% (10.2, 25.1), p = 0.046; SM: 22.7% (19.5, 27.8) vs. 13.8% (10.2, 19.1), p = 0.020). CONCLUSIONS: Native peak T1 values across all five calf muscle compartments, and ECV fractions of the anterior muscle group and the soleus muscle were significantly elevated in PAD patients compared with matched controls. Non-invasive T1 mapping and ECV quantification may be of interest for the study of PAD.

4.
Am J Cardiol ; 220: 56-66, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38580040

RESUMO

Peripheral artery disease (PAD) is associated with impaired blood flow in the lower extremities and histopathologic changes of the skeletal calf muscles, resulting in abnormal microvascular perfusion. We studied the use of convolution neural networks (CNNs) to differentiate patients with PAD from matched controls using perfusion pattern features from contrast-enhanced magnetic resonance imaging (CE-MRI) of the skeletal calf muscles. We acquired CE-MRI based skeletal calf muscle perfusion in 56 patients (36 patients with PAD and 20 matched controls). Microvascular perfusion imaging was performed after reactive hyperemia at the midcalf level, with a temporal resolution of 409 ms. We analyzed perfusion scans up to 2 minutes indexed from the local precontrast arrival time frame. Skeletal calf muscles, including the anterior muscle, lateral muscle, deep posterior muscle group, and the soleus and gastrocnemius muscles, were segmented semiautomatically. Segmented muscles were represented as 3-dimensional Digital Imaging and Communications in Medicine stacks of CE-MRI perfusion scans for deep learning (DL) analysis. We tested several CNN models for the 3-dimensional CE-MRI perfusion stacks to classify patients with PAD from matched controls. A total of 2 of the best performing CNNs (resNet and divNet) were selected to develop the final classification model. A peak accuracy of 75% was obtained for resNet and divNet. Specificity was 80% and 94% for resNet and divNet, respectively. In conclusion, DL using CNNs and CE-MRI skeletal calf muscle perfusion can discriminate patients with PAD from matched controls. DL methods may be of interest for the study of PAD.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Músculo Esquelético , Redes Neurais de Computação , Doença Arterial Periférica , Humanos , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Perna (Membro)/irrigação sanguínea , Fluxo Sanguíneo Regional/fisiologia , Aprendizado Profundo
5.
J Vasc Surg Venous Lymphat Disord ; 12(4): 101895, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679142

RESUMO

OBJECTIVE: Iliocaval thrombotic obstruction is a challenging condition, especially because thrombus age and corresponding pathological remodeling at presentation are unknown, which directly impacts management. Our aim was to assess the ability of magnetic resonance imaging (MRI) in determining age thresholds of experimentally created inferior vena cava (IVC) thrombosis in pigs. METHODS: We used a previously described swine model of IVC thrombosis. The animals underwent MRI at baseline, immediately after thrombosis creation, and after a follow-up period extending from 2 to 28 days. Thirteen pigs were divided into three groups according to disease chronicity: acute group (AG; n = 5), subacute group (SAG; n = 4), and chronic group (CG; n = 4), with a mean thrombosis age of 6.4 ± 2.5 days, 15.7 ± 2.8 days, and 28 ± 5.7 days, respectively. A T1-weighted volumetric interpolated breath-hold examination sequence was used to anatomically delineate IVC thrombus as a region of interest. Three other MRI sequences were used to assess the thrombus signal. RESULTS: The Kruskal-Wallis test showed a statistically significant difference in T1 relaxation times after contrast injection (P = .026) between the three groups of chronicity. The AG (360.2 ± 102.5 ms) was significantly different from the CG (336.7 ± 55.2 ms; P = .003), and the SAG (354.1 ± 89.7 ms) was significantly different from the AG (P = .027). There was a statistically significant difference in native T2 relaxation times (P = .038) between the three groups. The AG (160 ± 86.7 ms) was significantly different from the SAG (142.3 ± 55.4 ms; P = .027), and the SAG was significantly different from the CG (178.4 ± 11.7 ms; P = .004). CONCLUSIONS: This study highlighted MRI characteristics in a swine model that might have the potential to significantly differentiate subacute and chronic stages from an acute stage of deep vein thrombosis in humans. Further clinical studies in humans are warranted. CLINICAL RELEVANCE: In addition to providing a better understanding of venous thrombosis remodeling over time, magnetic resonance imaging has the potential to be a tool that could allow us to characterize the composition of venous thrombus over an interval, allowing for a refined analysis of the local evolution of venous thrombosis. We propose a noninvasive and innovative method to characterize different thresholds of chronicity with magnetic resonance imaging features of central deep vein thrombosis of the inferior vena cava experimentally obtained using a totally endovascular in vivo swine model, mimicking human pathophysiology. Being able to determine these features noninvasively is critical for vascular specialists when it comes to choosing between fibrinolytic therapy, percutaneous thrombectomy, or surgical management.


Assuntos
Modelos Animais de Doenças , Veia Ilíaca , Imageamento por Ressonância Magnética Multiparamétrica , Veia Cava Inferior , Trombose Venosa , Animais , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/patologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/patologia , Suínos , Fatores de Tempo , Valor Preditivo dos Testes , Sus scrofa , Doença Crônica , Doença Aguda
6.
Magn Reson Imaging ; 106: 31-42, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38065273

RESUMO

Diagnosing and assessing the risk of peripheral artery disease (PAD) has long been a focal point for medical practitioners. The impaired blood circulation in PAD patients results in altered microvascular perfusion patterns in the calf muscles which is the primary location of intermittent claudication pain. Consequently, we hypothesized that changes in perfusion and increase in connective tissue could lead to alterations in the appearance or texture patterns of the skeletal calf muscles, as visualized with non-invasive imaging techniques. We designed an automatic pipeline for textural feature extraction from contrast-enhanced magnetic resonance imaging (CE-MRI) scans and used the texture features to train machine learning models to detect the heterogeneity in the muscle pattern among PAD patients and matched controls. CE-MRIs from 36 PAD patients and 20 matched controls were used for preparing training and testing data at a 7:3 ratio with cross-validation (CV) techniques. We employed feature arrangement and selection methods to optimize the number of features. The proposed method achieved a peak accuracy of 94.11% and a mean testing accuracy of 84.85% in a 2-class classification approach (controls vs. PAD). A three-class classification approach was performed to identify a high-risk PAD sub-group which yielded an average test accuracy of 83.23% (matched controls vs. PAD without diabetes vs. PAD with diabetes). Similarly, we obtained 78.60% average accuracy among matched controls, PAD treadmill exercise completers, and PAD exercise treadmill non-completers. Machine learning and imaging-based texture features may be of interest in the study of lower extremity ischemia.


Assuntos
Diabetes Mellitus , Doença Arterial Periférica , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Claudicação Intermitente , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/irrigação sanguínea
7.
J Endovasc Ther ; : 15266028231210228, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37936418

RESUMO

OBJECTIVE: In many studies on aortic disease, women are underrepresented. The present study aims to assess sex-specific morphometric differences and gain more insight into endovascular treatment of the ascending aorta (AA) and arch. METHODS: Electrocardiogram-gated cardiac computed tomography scans of 116 consecutive patients who were evaluated for transcatheter aortic valve replacement were retrospectively reviewed. Measurements of the AA and aortic arch were made in multiplanar views, perpendicular to the semi-automatic centerline. Multiple linear regression analysis was performed to identify predictors affecting AA and aortic arch diameter in men and women. Propensity score matching was used to investigate whether sex influences aortic morphology. RESULTS: In both sexes, body surface area (BSA) was identified as a positive predictor and diabetes as a negative predictor for aortic diameters. In men, age was identified as a positive predictor and smoking as a negative predictor for aortic diameters. Propensity score matching identified 40 pairs. Systolic and diastolic mean diameters and AA length were significantly wider in men. On average, male aortas were 7.4% wider than female aortas, both in systole and diastole. CONCLUSIONS: The present analysis demonstrates that, in women, increased BSA is associated with increased aortic arch diameters, while diabetes is associated with decreased AA and arch diameters. In men, increased BSA and age are associated with increased AA and arch diameters, while smoking and diabetes are associated with decreased AA and arch diameters. Men were confirmed to have 7.4% greater AA and arch diameters than women. CLINICAL IMPACT: Men had 7.4% greater ascending aorta and arch diameters than women in a retrospective cohort, gated computed tomography-based study of 116 patients. Sex-specific differences in ascending aortic and arch size should be considered by aortic endovascular device manufacturers and physicians when developing ascending and arch endografts and planning aortic interventions.

8.
Eur J Vasc Endovasc Surg ; 66(6): 775-782, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37201718

RESUMO

OBJECTIVE: To describe the trends in management and outcomes of patients with acute type B aortic dissection in the International Registry of Acute Aortic Dissection. METHODS: From 1996 - 2022, 3 908 patients were divided into similar sized quartiles (T1, T2, T3, and T4). In hospital outcomes were analysed for each quartile. Survival rates following admission were compared using Kaplan-Meier analyses with Mantel-Cox Log rank tests. RESULTS: Endovascular treatment increased from 19.1% in T1 to 37.2% in T4 (ptrend < .001). Correspondingly, medical therapy decreased from 65.7% in T1 to 54.0% in T4 (ptrend < .001), and open surgery from 14.8% in T1 to 7.0% in T4 (ptrend < .001). In hospital mortality decreased in the overall cohort from 10.7% in T1 to 6.1% in T4 (ptrend < .001), as well as in medically, endovascularly and surgically treated patients (ptrend = .017, .033, and .011, respectively). Overall post-admission survival at three years increased (T1: 74.8% vs. T4: 77.3%; p = .006). CONCLUSION: Considerable changes in the management of acute type B aortic dissection were observed over time, with a significant increase in the use of endovascular treatment and a corresponding reduction in open surgery and medical management. These changes were associated with a decreased overall in hospital and three year post-admission mortality rate among quartiles.

9.
J Vasc Interv Radiol ; 34(8): 1345-1352, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37028705

RESUMO

PURPOSE: To evaluate the radiation protection offered by an exoskeleton-based radiation protection system (Stemrad MD) and to compare it with that offered by conventional lead aprons. METHODS: The experimental setup involved 2 anthropomorphic phantoms, an operator, a patient, and a C-arm as the x-ray radiation source. Thermoluminescent detectors were used to measure radiation doses to different radiosensitive body parts on the operator phantom both with the exoskeleton and a conventional lead apron at the left radial and right femoral positions. Detected radiation doses for the exoskeleton and lead apron for different body parts and positions were compared. RESULTS: At the left radial position, the mean radiation dose (mGy) reduction by the exoskeleton compared with that by the lead apron was >90% for the left eye lens (0.22 ± 0.13 vs 5.18 ± 0.08; P < .0001), right eye lens (0.23 ± 0.13 vs 4.98 ± 0.10; P < .0001), left head (0.11 ± 0.16 vs 3.53 ± 0.07; P < .0001), right head (0.27 ± 0.09 vs 3.12 ± 0.10; P < .0001), and left brain (0.04 ± 0.08 vs 0.46 ± 0.07; P < .0001). At the right femoral position, radiation reduction was >90% for the left eye lens (0.14 ± 0.10 vs 4.16 ± 0.09; P < .0001), right eye lens (0.06 ± 0.08 vs 1.90 ± 0.11; P < .0001), left head (0.10 ± 0.08 vs 4.39 ± 0.08; P < .0001), left brain (0.03 ± 0.07 vs 1.44 ± 0.08; P < .0001), right brain (0.00 ± 0.14 vs 0.11 ± 0.13; P = .06), and thyroid (0.04 ± 0.07 vs 0.27 ± 0.09; P < .0001). Protection of the torso was equivalent to that offered by conventional lead aprons. CONCLUSIONS: The exoskeleton-based system provided superior radiation protection to the physician compared with that provided by conventional lead aprons. The effects are particularly impactful for the brain, eye lens, and head areas.


Assuntos
Exoesqueleto Energizado , Exposição Ocupacional , Proteção Radiológica , Humanos , Doses de Radiação , Roupa de Proteção , Cabeça , Exposição Ocupacional/prevenção & controle
10.
J Endovasc Ther ; : 15266028231160661, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36942629

RESUMO

OBJECTIVE: Poor ergonomic posture during interventional procedures might lead to increased physical discomfort and work-related musculoskeletal disorders. Adjunctive equipment such as lead aprons (LAs) has been shown to increase ergonomic posture risk (EPR). The objective of this study was to evaluate the effectiveness of StemRad MD (StemRad Ltd., Tel Aviv, Israel), a weightless exoskeleton-based radiation protective ensemble, in reducing EPR on the operator using wearable inertial measurement unit (IMU) sensors. METHODS: A prospective, observational study was conducted at an academic hospital. Inertial measurement unit sensors were affixed to the upper back of 9 interventionalists to assess ergonomic risk posture during endovascular procedures while wearing a traditional LA or the StemRad MD radiation protection system. Total fluoroscopy time, procedure type, and ergonomic risk postures were recorded and analyzed. RESULTS: Twenty-one cases were performed with StemRad MD and 30 with LAs. Mean procedure time for the StemRad MD procedures was 48.4±23.3 minutes (range: 24-106 min), and for LA procedures, it was 34.66±25.83 minutes (range: 6-100 min) (p=.060). The operators assumed low-risk ergonomic positions in 96.1% of StemRad MD cases and in 62.9% of LA cases (p=.001), and high-risk ergonomic positions in 0% and 6.2%, respectively (p=.80). Mean EPR score for StemRad MD was 1.16, and for the LA, it was 1.49 (p=.001). CONCLUSIONS: StemRad MD significantly reduces the EPR to the torso compared with a LA-based radiation protection system. CLINICAL IMPACT: Poor ergonomic posture during interventional procedures might leas to work-related musculoskeletal disorders for healthcare workers. StemRad MD, a weightless, exoskeleton-based radiation protection system was shown to significantly reduce ergonomic posture risk to the torso compared to conventional lead aprons. This might lead to reduced physical discomfort for procedure-based specialists.

11.
J Am Heart Assoc ; 12(3): e027649, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36688362

RESUMO

Background Computational fluid dynamics has shown good agreement with contrast-enhanced magnetic resonance imaging measurements in cardiovascular disease applications. We have developed a biomechanical model of microvascular perfusion using contrast-enhanced magnetic resonance imaging signal intensities derived from skeletal calf muscles to study peripheral artery disease (PAD). Methods and Results The computational microvascular model was used to study skeletal calf muscle perfusion in 56 individuals (36 patients with PAD, 20 matched controls). The recruited participants underwent contrast-enhanced magnetic resonance imaging and ankle-brachial index testing at rest and after 6-minute treadmill walking. We have determined associations of microvascular model parameters including the transfer rate constant, a measure of vascular leakiness; the interstitial permeability to fluid flow which reflects the permeability of the microvasculature; porosity, a measure of the fraction of the extracellular space; the outflow filtration coefficient; and the microvascular pressure with known markers of patients with PAD. Transfer rate constant, interstitial permeability to fluid flow, and microvascular pressure were higher, whereas porosity and outflow filtration coefficient were lower in patients with PAD than those in matched controls (all P values ≤0.014). In pooled analyses of all participants, the model parameters (transfer rate constant, interstitial permeability to fluid flow, porosity, outflow filtration coefficient, microvascular pressure) were significantly associated with the resting and exercise ankle-brachial indexes, claudication onset time, and peak walking time (all P values ≤0.013). Among patients with PAD, interstitial permeability to fluid flow, and microvascular pressure were higher, while porosity and outflow filtration coefficient were lower in treadmill noncompleters compared with treadmill completers (all P values ≤0.001). Conclusions Computational microvascular model parameters differed significantly between patients with PAD and matched controls. Thus, computational microvascular modeling could be of interest in studying lower extremity ischemia.


Assuntos
Doença Arterial Periférica , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Claudicação Intermitente , Perna (Membro)/irrigação sanguínea , Músculo Esquelético , Perfusão
12.
J Endovasc Ther ; : 15266028221144590, 2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36565274
13.
EJVES Vasc Forum ; 57: 5-11, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36388464

RESUMO

Objective: Assessment of the quality of the final product (QFP) is critical in simulation training, such as the clock face suture (CFS) exercise that is used to assess trainees' needle handling and suturing accuracy. Objective Structured Assessment of Technical Skill (OSATS) scores are the gold standard for the evaluation of trainees. The aim was to investigate variability in the use of OSATS checklists and to evaluate a semi-automatic method of suture analysis vs. OSATS scores. Methods: Details of 287 CFSs performed by trainees during Fundamentals in Vascular Surgery examinations were collected. All were rated according to a seven item OSATS checklist, including QFP score and an overall score by one or two expert surgeons immediately after completion. Interassessor variability was assessed for the CFS that were assessed by two assessors.In order to assess intra- and interassessor variability, 50 CFS pictures were chosen randomly and submitted to three expert surgeons to rate the QFP twice and to carry out a semi-automatic image analysis of each CFS and the estimated cumulative error (CE; mm) recorded. It was hypothesised that the CE correlates to OSATS checklist items or overall score. Variables were compared for correlation with OSATS results using a linear regression. A Pearson's test was used to confirm the proposed hypothesis. Results: Mean ± standard deviation overall score for the OSATS checklist was 20.61 ± 6.33. Inter- and intra-assessor correlation were statistically significant regarding OSATS checklist items. Both correlations presented a low coefficient of determination, indicating variability. The mean CE was 16.07 ± 4.84 mm, and the correlation between the QFP and CE was statistically significant, proving that CE is an objective metric by which to assess the QFP. Conclusion: OSATS score demonstrated intra- and interassessor variability, although there was a significant correlation between scores. CE is an objective metric that is not subject to assessor subjectivity or interassessor variability and is correlated with the gold standard of evaluation.

15.
J Endovasc Ther ; : 15266028221113752, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35869618

RESUMO

PURPOSE: To demonstrate the feasibility of Octafen technique, a novel endovascular configuration for the treatment of thoracoabdominal aortic aneurysms (TAAA). TECHNIQUE: Two patients with complex TAAA and high surgical risk were treated with Octafen endograft configuration in a hybrid operating room with computed tomography (CT)-fluoroscopy image fusion guidance, using 3D-3D fusion techniques to facilitate procedural success. The procedure is a modification of the previously-described Octopus technique for endovascular repair of TAAA. The main advantage of this technique is the ability to use devices to repair a TAAA with the combination of off-the-shelf and noninvestigational custom-made devices. The devices used are readily available to most practicing vascular surgeons, which provides an alternative treatment in case of limited access to investigational devices, in time-sensitive cases, and in patients with limited functional capacity who cannot undergo open repair. In the modification described herein, we use a combination of standard bifurcated endovascular aneurysm repair (EVAR) devices (Excluder; W.L. Gore & Associates, Flagstaff, Arizona) in combination with a 2-vessel renal fenestrated device (Z-Fen; Cook Medical, Bloomington, Indiana). The article describes a step-by-step approach to this technique to elucidate pitfalls, benefits, and advantages. CONCLUSION: The Octafen technique might offer an alternative option for thoracoabdominal aneurysm treatment circumventing the need for access to custom-made, investigational devices. CLINICAL IMPACT: In this manuscript, we describe a technique for endovascular repair of thoraco-abdominal aortic aneurysms that involves the combination of off-the-shelf and non-investigational, custom-made devices. The 'Octafen' technique provides a treatment alternative in case of limited access to investigational devices and can be adjusted according to patient anatomy.

16.
Eur J Vasc Endovasc Surg ; 63(4): 623-630, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272950

RESUMO

OBJECTIVE: To develop a large animal model of iliocaval deep venous thrombosis (DVT), which enables development and evaluation of interventional management and existing imaging modalities. METHODS: The experimental protocol consisted of a total endovascular approach. Pigs were percutaneously accessed through the right internal jugular and bilateral femoral veins. Three balloon catheters were inflated to induce venous stasis in the infrarenal inferior vena cava (IVC) and bilateral common iliac veins (CIVs). Hypercoagulability was induced by injecting 10 000 IU of thrombin. After 2.5 hours, the balloon catheters were removed before animal recovery. After seven, 14, 21, 28, or 35 days, animals were euthanised; the IVC and CIV were harvested en bloc, cross sectioned and prepared for histological examination. Multimodal imaging was performed before and after thrombus creation, and before animal euthanasia. RESULTS: Thirteen female domestic pigs with a mean weight of 59.3 kilograms were used. The mean maximum IVC diameter and area were 16.4 mm and 1.2 cm2, respectively. The procedure was successful in 12 animals with occlusive venous thrombosis in the region of interest on immediate post-operative magnetic resonance venography and a mean thrombus volume of 19.8 cm3. Clinical pathology results showed platelet consumption, D dimer increase, and inflammatory response. Histological evaluation demonstrated a red cell, fibrin, and platelet rich thrombus on day 1, with progressive inflammatory cell infiltration from day 7. Collagen deposition appeared in week 2 and neovascularisation in week 3. CONCLUSION: Endovascular occlusion combined with thrombin infusion is a reliable minimally invasive approach to produce acute and subacute DVT in a large animal model.


Assuntos
Procedimentos Endovasculares , Trombose Venosa , Animais , Modelos Animais de Doenças , Procedimentos Endovasculares/métodos , Feminino , Humanos , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/cirurgia , Stents , Suínos , Trombina , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Trombose Venosa/terapia
18.
J Cardiovasc Surg (Torino) ; 62(6): 527-534, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34581554

RESUMO

INTRODUCTION: Since the outbreak of the 2019 coronavirus (COVID-19), vascular specialists have faced dramatic changes in clinical and surgical practice. Although COVID-19 pulmonary signs and symptoms were the most pertinent problems initially, in the long term, cardiovascular complications became the most fearsome, with poor outcomes in terms of morbidity and mortality. Algorithms and decision-making procedures have been modified, not only to treat new clinical findings in COVID-19 positive patients, but also to avoid complications related to pulmonary and systemic infections. Additionally, COVID-19-negative patients experienced challenging management, due to hospital crowding, the risk of nosocomial COVID-19 transmission, and pandemic emergencies. In this context, aortic interventions were subject to several difficulties. First, in COVID-19-positive patients, there was the onset of new pathological scenarios including thrombotic manifestations and the subsequent complications. Second, in both COVID-19-negative and positive patients, there was a need to deliver optimal treatment with acceptable perioperative risks, forcing a rethinking of decision-making especially in terms of indications for treatments. The aim of this systematic review is to present evidence published on COVID-19 and aortic-related issues, highlighting some challenging aspects regarding management, treatment and outcomes. EVIDENCE ACQUISITION: Data search was performed on PubMed, Scopus and Web of Science, using as time range "January 1st, 2000 - May 1st, 2021." Only articles in English language were included. Key words used for the query were "Aorta" AND "COVID-19" OR "SARS-CoV-2." Furthermore, the NCBI database of "SARS-CoV-2 Resources" was interrogated to find further relevant studies. EVIDENCE SYNTHESIS: The search retrieved 416 papers; among these, 46 studies were eligible and reviewed in depth. The published literature suggests the existence of a hypercoagulable state in patients with COVID-19 disease occurring via direct and indirect mechanisms. COVID-19 infection seems to promote a prothrombotic status that aggravates vascular disease. Regardless of clinical laboratory or status, active COVID-19 infection is considered a risk factor for poor vascular surgery outcomes. Specifically, it is associated with a fourfold increased risk of death and a threefold increased risk of major adverse events. Prognosis of patients hospitalized with COVID-19 disease is often determined by the extent of pulmonary disease, although vascular complications also greatly affect outcomes. Nevertheless, although COVID­19 is highly morbid, in high­risk operations good outcomes can still be achieved even in elderly patients with COVID­19. CONCLUSIONS: In the case of aortic disease during active COVID-19 infection, poor outcomes are associated with COVID-19 vascular and non-vascular complications, while for COVID-19-negative patients not much changed in terms of outcomes, despite the difficulties in management. Endovascular repair, when possible, minimized the impact of treatment, reducing the risk of COVID-related postoperative complications or acquired infection in negative patients.


Assuntos
Anticoagulantes/uso terapêutico , Doenças da Aorta/cirurgia , Coagulação Sanguínea/efeitos dos fármacos , COVID-19/terapia , Procedimentos Endovasculares , Trombofilia/tratamento farmacológico , Procedimentos Cirúrgicos Vasculares , Anticoagulantes/efeitos adversos , Doenças da Aorta/sangue , Doenças da Aorta/mortalidade , COVID-19/sangue , COVID-19/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Humanos , Complicações Pós-Operatórias/etiologia , Medição de Risco , Fatores de Risco , Trombofilia/sangue , Trombofilia/mortalidade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
19.
Ann Vasc Surg ; 72: 383-389, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32890642

RESUMO

BACKGROUND: Central venous occlusive disease (CVOD) is a prevalent problem in patients with end-stage renal disease (ESRD) and can lead to access malfunction or ligation for symptomatic relief. The purpose of this study is to evaluate the efficacy of the TriForce® Peripheral Crossing Set (Cook Medical), a novel reinforced telescoping catheter set designed to provide additional support for crossing difficult central venous occlusions. METHODS: This is a single-center retrospective study from a quaternary referral center. We identified 37 patients over a 17-month period who underwent 56 attempts at endovascular recanalization for the treatment of central venous occlusion. Technical success rates, procedural data, and outcomes were compared between those undergoing recanalization using traditional wire/catheter sets versus the TriForce catheter set. RESULTS: Average age was 48 ± 2 years. Comorbidities were similar between the two cohorts and included ESRD (61%), deep venous thrombosis (30%), and May-Thurner syndrome (7%). Forty attempts were made with traditional wire/catheter sets and 16 attempts with the TriForce catheter set to treat 2.1 ± 0.2 and 1.9 ± 0.3 occluded venous segments, respectively (P = 0.74). Technical success rates were significantly higher for the group undergoing recanalization using the TriForce catheter (69% versus 38%, P = 0.04) and 4 patients were successfully recanalized using the TriForce catheter set after a failed attempt with traditional wire/catheter sets. Mean fluoroscopy time and radiation dose were 13 ± 3 min and 14,623 ± 2,775 µGy∗m2 for traditional techniques versus 30 ± 6 min and 30,408 ± 10,433 µGy∗m2 for the novel telescoping catheter set (P = 0.01 and 0.09, respectively). Freedom from reintervention at 1 year was 60% for the TriForce cohort versus 44% for the traditional wire/catheter cohort (P = 0.25). CONCLUSIONS: The novel TriForce reinforced telescoping catheter set is a useful adjunct that may improve recanalization rates of CVOD compared with traditional wire/catheter sets.


Assuntos
Procedimentos Endovasculares/instrumentação , Dispositivos de Acesso Vascular , Doenças Vasculares/terapia , Veias , Obstrução do Cateter , Cateterismo Venoso Central/efeitos adversos , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
20.
Am J Cardiol ; 140: 140-147, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33144163

RESUMO

Peripheral artery disease (PAD) is associated with impaired lower extremity function. We hypothesized that contrast-enhanced magnetic resonance imaging (CE-MRI) based arterial signal enhancement (SE) measures are associated with markers of PAD. A total of 66 participants were enrolled, 10 were excluded due to incomplete data, resulting in 56 participants for the final analyses (36 PAD, 20 matched controls). MR imaging was performed postreactive hyperemia using bilateral thigh blood-pressure cuffs. First pass-perfusion images were acquired at the mid-calf region with a high-resolution saturation recovery gradient echo pulse sequence, and arterial SE was measured for the lower extremity arteries. As expected, peak walking time (PWT) was reduced in PAD patients compared with controls (282 [248 to 317] sec, vs 353 [346 to 360] sec; p = 0.002), and postexercise ankle brachial index (ABI) decreased in PAD patients but not in controls (PAD: 0.75 ± 0.2, 0.60 [0.5 to 0.7]; p <0.001; vs Controls: 1.17 ± 0.1, 1.19 [1.1 to 1.2]; p = 0.50). Intraclass correlation coefficients were excellent for inter- and intraobserver variability of arterial tracings (n = 10: 0.95 (95%-confidence interval [CI]: 0.94 to 0.96), n = 9: 1.0 (CI: 1.0 to 1.0). Minimum arterial SE was reduced in PAD patients compared with matched controls (128 [110 to 147] A.U. vs 192 [149 to 234] A.U., p = 0.003). Among PAD patients but not in controls the maximum arterial SE was associated with the estimated glomerular filtration rate (eGFR), a marker of renal function (n = 36, ß = 1.37, R2 = 0.12, p = 0.025). In conclusion, CE-MRI first-pass arterial perfusion is impaired in PAD patients compared with matched controls and associated with markers of lower extremity ischemia.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Perna (Membro)/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico , Fluxo Sanguíneo Regional/fisiologia , Caminhada/fisiologia , Idoso , Índice Tornozelo-Braço/métodos , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Doença Arterial Periférica/fisiopatologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA