Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Clin Pharmacol Ther ; 53(4): 335-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25669614

RESUMO

OBJECTIVES: To establish the relative bioavailability (rBA) between two p.o. 5-mg levomethadone hydrochloride formulations, i.e., L-Polamidon® 5 mg tablets (test) vs. L-Polamidon® solution for substitution (reference). To assess the safety and tolerability of both formulations. SUBJECT AND METHODS: A total of 33 healthy male subjects, aged 29 ± 6 years (BMI: 23.9 ± 2.5 kg/m2) completed this single center, open-label, randomized, 2-period cross-over study with single dose administrations under fasting conditions and coadministration with naltrexone for safety reasons. Administrations of both investigational products were separated by a washout period of at least 2 weeks, i.e., 13 treatmentfree days. The total dose for each subject was 2 x 5 mg resulting in 10 mg levomethadone hydrochloride. For pharmacokinetic evaluation, blood samples were withdrawn until 72 hours postdose. A validated non-stereoselective liquid chromatography-tandem mass spectroscopy method (LC-MS/MS) was applied for the determination of levomethadone in plasma. The lower limit of quantitation was 0.100 ng/mL. Adverse events were descriptively analyzed in the study population. RESULTS: The geometric means of the parameters related with the extent of total exposure of levomethadone, i.e., AUC(0-tlast) and AUC(0-∞), were 244.422 ng x h/mL and 332.999 ng x h/mL for test and 246.837 ng x h/mL and 329.467 ng×h/mL for reference, respectively. The geometric means of the peak exposure for levomethadone, i.e., Cmax, were 8.923 ng/mL for test and 8.635 ng/mL for reference. The point estimates (PEs) of the Test/Reference (T/R) adjusted geometric mean ratios of AUC(0-last), AUC(0-∞), and C(max) were 99.20%, 101.42%, and 104.11%, respectively, and all of them showed 90%-confidence intervals (CIs) within the range of 80.00 - 125.00% as suggested by regulatory requirements for bioequivalence assessment In total, 21 subjects experienced 55 AEs during the study, the most frequently reported AE, i.e., headache, accounted for 13 out of the total 55 AEs (23.6%) and no AEs of severe intensity were reported. CONCLUSIONS: Bioequivalence could be demonstrated in terms of rate and extent of absorption after administration of test and reference products under naltrexone protection. Concerning the safety evaluation, no negative implications on the possible use of the test formulation could be determined.


Assuntos
Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/farmacocinética , Metadona/administração & dosagem , Metadona/farmacocinética , Administração Oral , Adulto , Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/sangue , Analgésicos Opioides/química , Área Sob a Curva , Disponibilidade Biológica , Química Farmacêutica , Cromatografia Líquida , Estudos Cross-Over , Alemanha , Humanos , Masculino , Metadona/efeitos adversos , Metadona/sangue , Metadona/química , Soluções Farmacêuticas , Comprimidos , Espectrometria de Massas em Tandem , Adulto Jovem
2.
Eur J Pharm Biopharm ; 86(3): 337-50, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24075979

RESUMO

The so-called pharmaceutical solid chain, which encompasses drug substance micronisation to the final tablet production, at pilot plant scale is presented as a case study for a novel, highly potent, pharmaceutical compound: SAR114137. Various solid-state analytical methods, such as solid-state Nuclear Magnetic Resonance (ssNMR), Differential Scanning Calorimetry (DSC), Dynamic Water Vapour Sorption Gravimetry (DWVSG), hot-stage Raman spectroscopy and X-ray Powder Diffraction (XRPD) were applied and evaluated to characterise and quantify amorphous content during the course of the physical treatment of crystalline active pharmaceutical ingredient (API). DSC was successfully used to monitor the changes in amorphous content during micronisation of the API, as well as during stability studies. (19)F solid-state NMR was found to be the method of choice for the detection and quantification of low levels of amorphous API, even in the final drug product (DP), since compaction during tablet manufacture was identified as a further source for the formation of amorphous API. The application of different jet milling techniques was a critical factor with respect to amorphous content formation. In the present case, the change from spiral jet milling to loop jet milling led to a decrease in amorphous API content from 20-30 w/w% to nearly 0 w/w% respectively. The use of loop jet milling also improved the processability of the API. Stability investigations on both the milled API and the DP showed a marked tendency for recrystallisation of the amorphous API content on exposure to elevated levels of relative humidity. No significant impact of amorphous API on either the chemical stability or the dissolution rate of the API in drug formulation was observed. Therefore, the presence of amorphous content in the oral formulation was of no consequence for the clinical trial phases I and II.


Assuntos
Analgésicos/síntese química , Descoberta de Drogas/métodos , Análise Espectral Raman/métodos , Difração de Raios X/métodos , Química Farmacêutica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA