Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(15): 152502, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38682998

RESUMO

^{134}Xe is a candidate isotope for neutrinoless double beta decay (0νßß) search. In addition, the two-neutrino case (2νßß) allowed by the standard model of particle physics has not yet been observed. With the 656-kg natural xenon in the fiducial volume of the PandaX-4T detector, which contains 10.4% of ^{134}Xe, and its initial 94.9-day exposure, we have established the most stringent constraints on 2νßß and 0νßß of ^{134}Xe half-lives, with limits of 2.8×10^{22} yr and 3.0×10^{23} yr at 90% confidence level, respectively. The 2νßß (0νßß) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors for double beta decay searches.

2.
NPJ Digit Med ; 6(1): 204, 2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37925578

RESUMO

Big data serves as the cornerstone for constructing real-world deep learning systems across various domains. In medicine and healthcare, a single clinical site lacks sufficient data, thus necessitating the involvement of multiple sites. Unfortunately, concerns regarding data security and privacy hinder the sharing and reuse of data across sites. Existing approaches to multi-site clinical learning heavily depend on the security of the network firewall and system implementation. To address this issue, we propose Relay Learning, a secure deep-learning framework that physically isolates clinical data from external intruders while still leveraging the benefits of multi-site big data. We demonstrate the efficacy of Relay Learning in three medical tasks of different diseases and anatomical structures, including structure segmentation of retina fundus, mediastinum tumors diagnosis, and brain midline localization. We evaluate Relay Learning by comparing its performance to alternative solutions through multi-site validation and external validation. Incorporating a total of 41,038 medical images from 21 medical hosts, including 7 external hosts, with non-uniform distributions, we observe significant performance improvements with Relay Learning across all three tasks. Specifically, it achieves an average performance increase of 44.4%, 24.2%, and 36.7% for retinal fundus segmentation, mediastinum tumor diagnosis, and brain midline localization, respectively. Remarkably, Relay Learning even outperforms central learning on external test sets. In the meanwhile, Relay Learning keeps data sovereignty locally without cross-site network connections. We anticipate that Relay Learning will revolutionize clinical multi-site collaboration and reshape the landscape of healthcare in the future.

3.
Phys Rev Lett ; 131(19): 191002, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000419

RESUMO

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30 MeV/c^{2} to 2 GeV/c^{2}. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

4.
Phys Rev Lett ; 131(4): 041001, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37566838

RESUMO

We report a search for light dark matter produced through the cascading decay of η mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasielastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne·year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross section is set at 5.9×10^{-37} cm^{2} for a dark matter mass of 0.1 MeV/c^{2} and mediator mass of 300 MeV/c^{2}. The lowest upper limit of η to the dark matter decay branching ratio is 1.6×10^{-7}.

5.
Phys Rev Lett ; 130(26): 261001, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450819

RESUMO

We report the search results of light dark matter through its interactions with shell electrons and nuclei, using the commissioning data from the PandaX-4T liquid xenon detector. Low energy events are selected to have an ionization-only signal between 60 to 200 photoelectrons, corresponding to a mean nuclear recoil energy from 0.77 to 2.54 keV and electronic recoil energy from 0.07 to 0.23 keV. With an effective exposure of 0.55 tonne·year, we set the most stringent limits within a mass range from 40 MeV/c^{2} to 10 GeV/c^{2} for pointlike dark matter-electron interaction, 100 MeV/c^{2} to 10 GeV/c^{2} for dark matter-electron interaction via a light mediator, and 3.2 to 4 GeV/c^{2} for dark matter-nucleon spin-independent interaction. For DM interaction with electrons, our limits are closing in on the parameter space predicted by the freeze-in and freeze-out mechanisms in the early Universe.


Assuntos
Núcleo Celular , Elétrons
6.
Diagnostics (Basel) ; 13(4)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36832135

RESUMO

Lung cancer remains the most commonly diagnosed cancer and the leading cause of death from cancer. Recent research shows that the human eye can provide useful information about one's health status, but few studies have revealed that the eye's features are associated with the risk of cancer. The aims of this paper are to explore the association between scleral features and lung neoplasms and develop a non-invasive artificial intelligence (AI) method for detecting lung neoplasms based on scleral images. A novel instrument was specially developed to take the reflection-free scleral images. Then, various algorithms and different strategies were applied to find the most effective deep learning algorithm. Ultimately, the detection method based on scleral images and the multi-instance learning (MIL) model was developed to predict benign or malignant lung neoplasms. From March 2017 to January 2019, 3923 subjects were recruited for the experiment. Using the pathological diagnosis of bronchoscopy as the gold standard, 95 participants were enrolled to take scleral image screens, and 950 scleral images were fed to AI analysis. Our non-invasive AI method had an AUC of 0.897 ± 0.041(95% CI), a sensitivity of 0.836 ± 0.048 (95% CI), and a specificity of 0.828 ± 0.095 (95% CI) for distinguishing between benign and malignant lung nodules. This study suggested that scleral features such as blood vessels may be associated with lung cancer, and the non-invasive AI method based on scleral images can assist in lung neoplasm detection. This technique may hold promise for evaluating the risk of lung cancer in an asymptomatic population in areas with a shortage of medical resources and as a cost-effective adjunctive tool for LDCT screening at hospitals.

7.
Phys Rev Lett ; 130(2): 021802, 2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36706410

RESUMO

A search for interactions from solar ^{8}B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne year, and no significant excess of events is observed. Among the results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar ^{8}B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c^{2}.

8.
Phys Rev Lett ; 129(16): 161803, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306747

RESUMO

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the 95.0-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be 1.5×10^{-50} cm^{2} for a fermionic dark matter mass of 40 MeV/c^{2} with 90% confidence level.

9.
Phys Rev Lett ; 129(16): 161804, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306755

RESUMO

We report a search on sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne year exposure collected by the PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and the electron. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such a dark matter candidate into photon final states. In particular, we present the first direct detection limits for a vector (axial-vector) interaction which are the strongest in the mass range from 35 to 55 (25 to 45) keV/c^{2} in comparison to other astrophysical and cosmological constraints.

10.
Front Chem ; 10: 946157, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36105308

RESUMO

Identifying new biomarkers is necessary and important to diagnose and treat malignant lung cancer. However, existing protein marker detection methods usually require complex operation steps, leading to a lag time for diagnosis. Herein, we developed a rapid, minimally invasive, and convenient nucleic acid biomarker recognition method, which enabled the combined specific detection of 11 lung cancer typing markers in a microliter reaction system after only one sampling. The primers for the combined specific detection of 11 lung cancer typing markers were designed and screened, and the microfluidic chip for parallel detection of the multiple markers was designed and developed. Furthermore, a miniaturized microfluidic-based analyzer was also constructed. By developing a microfluidic chip and a miniaturized nucleic acid analyzer, we enabled the detection of the mRNA expression levels of multiple biomarkers in rice-sized tissue samples. The miniaturized nucleic acid analyzer could detect ≥10 copies of nucleic acids. The cell volume of the typing reaction on the microfluidic chip was only 0.94 µL, less than 1/25 of that of the conventional 25-µL Eppendorf tube PCR method, which significantly reduced the testing cost and significantly simplified the analysis of multiple biomarkers in parallel. With a simple injection operation and reverse transcription loop-mediated isothermal amplification (RT-LAMP), real-time detection of 11 lung cancer nucleic acid biomarkers was performed within 45 min. Given these compelling features, 86 clinical samples were tested using the miniaturized nucleic acid analyzer and classified according to the cutoff values of the 11 biomarkers. Furthermore, multi-biomarker analysis was conducted by a machine learning model to classify different subtypes of lung cancer, with an average area under the curve (AUC) of 0.934. This method shows great potential for the identification of new nucleic acid biomarkers and the accurate diagnosis of lung cancer.

11.
Phys Rev Lett ; 128(17): 171801, 2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35570440

RESUMO

We report a novel search for the cosmic-ray boosted dark matter using the 100 tonne·day full dataset of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10^{-31} and 10^{-28} cm^{2} for dark matter masses from 0.1 MeV/c^{2} to 0.1 GeV/c^{2}, with a large parameter space previously unexplored by experimental collaborations.

12.
Research (Wash D C) ; 2022: 9798721, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38645679

RESUMO

Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of 136Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a 136Xe exposure of 15.5 kg-year, we establish the half-life as 2.27 ± 0.03(stat.) ± 0.10(syst.) × 1021 years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.

13.
Patterns (N Y) ; 2(2): 100197, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33659913

RESUMO

Intracranial aneurysm (IA) is an enormous threat to human health, which often results in nontraumatic subarachnoid hemorrhage or dismal prognosis. Diagnosing IAs on commonly used computed tomographic angiography (CTA) examinations remains laborious and time consuming, leading to error-prone results in clinical practice, especially for small targets. In this study, we propose a fully automatic deep-learning model for IA segmentation that can be applied to CTA images. Our model, called Global Localization-based IA Network (GLIA-Net), can incorporate the global localization prior and generates the fine-grain three-dimensional segmentation. GLIA-Net is trained and evaluated on a big internal dataset (1,338 scans from six institutions) and two external datasets. Evaluations show that our model exhibits good tolerance to different settings and achieves superior performance to other models. A clinical experiment further demonstrates the clinical utility of our technique, which helps radiologists in the diagnosis of IAs.

14.
Phys Rev Lett ; 127(26): 261802, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35029500

RESUMO

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7 tonne of liquid xenon target and an exposure of 0.63 tonne·year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of 3.8×10^{-47} cm^{2} at a dark matter mass of 40 GeV/c^{2}.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA