Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Chem ; 60(12): 1185-1188, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35919948

RESUMO

Codeine N-oxide 2 is an active metabolite of codeine obtained by oxidation and observed as a degradant in codeine drug products such as syrups. Oxidation of codeine's N-methyl function can deliver two regio-isomers due to chirality of the tetra-substituted nitrogen. Hydrogen peroxide oxidation of codeine was performed and induced two different isomers in a 9:1 ratio; these isomers were isolated using preparative high performance liquid chromatography (HPLC) and fully characterized by nuclear magnetic resonance (NMR) techniques. We describe the complete assignment of the minor isomer of codeine N-oxide 3 and attribute a (S) configuration (N-methyl axial) of the tetra-substituted nitrogen. The effects of N-oxidation on the 15 N chemical shifts of the codeine are presented. The 15 N shifts were determined using the CIGAR-HMBC experiment at natural abundance, and the nitrogen resonance of codeine shifted downfield from 42.8 to 118.7 ppm for both N-oxide isomers.


Assuntos
Codeína , Nitrogênio , Isomerismo , Oxirredução , Óxidos , Isótopos de Carbono , Isótopos de Nitrogênio
2.
J Pharm Biomed Anal ; 155: 298-305, 2018 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-29679874

RESUMO

Calcium gluconate glucoheptonate (GGCa) is known to interact with glass containers, leading to the leaching of aluminum from the glass into the solution at toxic level. Therefore, plastic containers seem to be a preferable packaging alternative. Nevertheless, plastics contain potentially toxic additives which could be released into the solution. In order to study content container interaction between GGCa and two plastic containers (polypropylene PP and polyethylene PE containers), an HPLC-PDA method was developed to separate, detect and quantify eleven additives commonly found in plastic materials, with good limit of detection and quantification. This method was then applied to evaluate the compatibility between GGCa and the two plastic containers. After 3 months of storage at 25 °C, none of the eleven additives were detected in GGCa solutions. The safety concern threshold (SCT) and of the analytical evaluation threshold (AET) were evaluated to discriminate the need to identify and qualify unknown peaks.


Assuntos
Gluconato de Cálcio/química , Cromatografia Líquida de Alta Pressão/métodos , Gluconatos/química , Plásticos/análise , Plásticos/química , Açúcares Ácidos/química , Contaminação de Medicamentos/prevenção & controle , Embalagem de Medicamentos/métodos , Vidro/análise , Vidro/química , Polipropilenos/química , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA