Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Int J Cardiol ; 417: 132545, 2024 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-39265788

RESUMO

AIMS: Infective endocarditis (IE) poses a significant clinical challenge, necessitating nuanced diagnostic tools for early and accurate detection. The diagnostic role of the hybrid technique of single-photon emission tomography-computed tomography with technetium-99 m-hexamethylpropyleneamine oxime-labelled leukocytes ([99mTc]Tc-HMPAO-SPECT/CT) has evolved in recent years. This single-center study assessed whether the recent inclusion in the 2023 European Society of Cardiology modified diagnostic criteria of IE (2023 ESC) of infectious lesions detected with [99mTc]Tc-HMPAO-SPECT/CT affects their diagnostic performance. METHODS AND RESULTS: Between 2015 and 2019, we enrolled 205 consecutive adults with suspected IE. All participants underwent [99mTc]Tc-HMPAO-SPECT/CT scans (370-740 MBq). Scans were deemed positive in the presence of intracardiac abnormal tracer uptake and/or within the cardiac implantable electronic device. Patients were prospectively followed-up for 12 ± 10 months. Local device infection (LDI) or IE was diagnosed in 75 (36.6 %) patients, while 72 (35.1 %) [99mTc]Tc-HMPAO-SPECT/CT results returned positive. Moreover, extracardiac infectious foci were detected in 25 % of [99mTc]Tc-HMPAO-SPECT/CT scans. The inclusion of both intracardiac and extracardiac lesions detected with [99mTc]Tc-HMPAO-SPECT/CT yields significantly higher sensitivity (p = 0.003) and negative predictive value (NPV) (p = 0.009). CONCLUSION: The inclusion of [99mTc]Tc-HMPAO-SPECT/CT into the IE diagnostic work-up improves the appropriate classification of patients. For patients with IE, the extended inclusion of lesions detected with [99mTc]Tc-HMPAO-SPECT/CT in the ESC 2023 diagnostic criteria significantly improves sensitivity and NPV while reducing potential IE misdiagnoses. This pioneering imaging modality is poised to become an integral component of clinical practice, promising to advance IE diagnosis and management.


Assuntos
Endocardite , Leucócitos , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tecnécio Tc 99m Exametazima , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Endocardite/diagnóstico por imagem , Leucócitos/metabolismo , Estudos Prospectivos , Seguimentos , Adulto
4.
J Clin Med ; 13(11)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38892799

RESUMO

Cardiac amyloidosis, a condition characterized by abnormal protein deposition in the heart, leads to restrictive cardiomyopathy and is notably associated with an increased risk of arrhythmias and conduction disorders. This article reviews the current understanding and management strategies for these cardiac complications, with a focus on recent advancements and clinical challenges. The prevalence and impact of atrial arrhythmias, particularly atrial fibrillation, are examined, along with considerations for stroke risk and anticoagulation therapy. The article also addresses the complexities of managing rate and rhythm control, outlining the utility and limitations of pharmacological agents and interventions such as catheter ablation. Furthermore, it reviews the challenges in the treatment of ventricular arrhythmias, including the contentious use of implantable cardioverter-defibrillators for primary and secondary prevention. Individualized approaches, considering the unique characteristics of cardiac amyloidosis, are paramount. Continuous research and clinical exploration are essential to refine treatment strategies and improve outcomes in this challenging patient population.

5.
Adv Clin Exp Med ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38934334

RESUMO

BACKGROUND: The path and interaction of leads within the cardiovascular system are influenced by various factors, including the implantation technique. Furthermore, the multifaceted composition of these leads, often comprising multiple materials, can contribute to their potential degradation and wear over time. OBJECTIVES: Our aim was to investigate the wear of lead insulation following the removal of transvenous leads and pinpoint the regions of the lead most vulnerable to damage. MATERIAL AND METHODS: We undertook a prospective analysis of patients from a single tertiary center who underwent transvenous lead explantation (TLE) between October 1, 2013, and July 31, 2015. Specifically, our examination focused on endocardial leads removed using simple screw-out and gentle traction techniques. Subsequent lead evaluations were conducted utilizing scanning electron and optical microscopes. RESULTS: Among the 86 patients who underwent the TLE procedure, 26 patients (30%) required the removal of 39 leads through simple traction. Inspection using scanning electron microscopy consistently indicated insulation damage across all leads. A total of 347 damaged sites were identified: 261 without lead unsealing and 86 exhibiting unsealing. Notably, the sections of the leads located within the intra-pocket area demonstrated the highest vulnerability to damage (odds ratio (OR): = 9.112, 95% confidence interval (95% CI): 3.326-24.960), whereas the intravenous regions displayed the lowest susceptibility (OR: 0.323, 95% CI: 0.151-0.694). CONCLUSIONS: Our study reveals that all evaluated leads exhibited insulation damage, with the intra-pocket segments manifesting a notably higher prevalence of damage than the intravenous segments.

7.
Echocardiography ; 40(10): 1068-1078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632153

RESUMO

BACKGROUND: His bundle pacing (HBP) has proved to be a valuable alternative enabling the physiological activation of cardiac contraction in cardiac resynchronization therapy (CRT). At present, however, little is known about the optimal method of programming of the His bundle-paced CRT systems in terms of achieving the best cardiac output. AIM: The aim of this study was to evaluate the impact of cardiac resynchronization therapy with conduction system pacing (CRT+CSP) on echo-based hemodynamic parameters in the early post-operative measurements. METHODS: The study enrollment criteria included: permanent atrial fibrillation, heart failure and bundle branch block. All patients underwent implantation of CRT + HBP. During the post-operative phase, we aimed to optimize HOT-CRT settings in order to achieve the greatest cardiac output assessed by complex echocardiographic measurements. RESULTS: The study included 21 patients, mean age 71.2 (6.3) years, predominantly men (71.4%) with non-ischemic cardiomyopathy 62%. All patients had heart failure with NYHA functional class III and IV (81%). Mean left ventricular ejection fraction was 27.5 (9.7%). The mean duration of the QRS complex was 148.8 ms. The effects of resynchronization pacing: HBP alone, HBP with left ventricular pacing, HBP with biventricular pacing (BiV) and BiV without HBP ​​were analyzed consecutively. HBP combined with left ventricular pacing demonstrated the best hemodynamic response. CONCLUSION: His bundle pacing coupled with LV pacing proved to be the most advantageous pacing program setting with regard to cardiac output. Moreover, it performed better than biventricular pacing and significantly better than RV pacing.

11.
Vaccines (Basel) ; 11(2)2023 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-36851297

RESUMO

Infective endocarditis (IE) is a growing epidemiological challenge. Appropriate diagnosis remains difficult due to heterogenous etiopathogenesis and clinical presentation. The disease may be followed by increased mortality and numerous diverse complications. Developing molecular imaging modalities may provide additional insights into ongoing infection and support an accurate diagnosis. We present the current evidence for the diagnostic performance and indications for utilization in current guidelines of the hybrid modalities: single photon emission tomography with technetium99m-hexamethylpropyleneamine oxime-labeled autologous leukocytes (99mTc-HMPAO-SPECT/CT) along with positron emission tomography with fluorodeoxyglucose (18F-FDG PET/CT). The role of molecular imaging in IE diagnostic work-up has been constantly growing due to technical improvements and the increasing evidence supporting its added diagnostic and prognostic value. The various underlying molecular processes of 99mTc-HMPAO-SPECT/CT as well as 18F-FDG PET/CT translate to different imaging properties, which should be considered in clinical practice. Both techniques provide additional diagnostic value in the assessment of patients at risk of IE. Nuclear imaging should be considered in the IE diagnostic algorithm, not only for the insights gained into ongoing infection at a molecular level, but also for the determination of the optimal clinical therapeutic strategies.

12.
Europace ; 25(3): 1100-1109, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36660771

RESUMO

AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Resultado do Tratamento , Estudos Retrospectivos
13.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36607529

RESUMO

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Assuntos
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudos Transversais , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Eletrocardiografia , Estimulação Cardíaca Artificial , Resultado do Tratamento
14.
J Nucl Cardiol ; 30(1): 343-353, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35819715

RESUMO

AIMS: This prospective, single-center study sought to assess to what extent there is interference between the hybrid technique of single-photon emission tomography-computed tomography with technetium99m-hexamethylpropyleneamine oxime-labeled leukocytes (99mTc-HMPAO-SPECT/CT) and antimicrobial therapy in patients with infective endocarditis (IE). METHODS AND RESULTS: During the years 2015-2019, we enrolled 205 consecutive adults with suspected IE, all underwent 99mTc-HMPAO-SPECT/CT. The study population was divided into those who had received antimicrobial therapy up to 30 days prior to 99mTc-HMPAO-SPECT/CT (group 1, n = 96) and those who had not (group 2, n = 109). Patients were prospectively observed for 12 ± 10 months. Group 1 presented higher positive predictive values (91.89% vs. 60.00%, = 0.001), and decreased negative predictive values (77.97% vs. 90.54%, P = 0.04). Patients treated with antimicrobial therapy displayed false-negative 99mTc-HMPAO-SPECT/CT results more often [odds ratio (OR), 4.63; 95% confidence interval (CI), 1.41-15.23, P = .01], particularly when intravenous (OR 5.37; 95% CI 1.73-16.62, P = .004), definite (OR 9.43; 95% CI 2.65-33.51, P = .001), and combination antibiotic regimens (OR 8.1; 95% CI 2.57-25.64, P = .001) had been administered. CONCLUSION: Prior antibiotic therapy affects 99mTc-HMPAO-SPECT/CT diagnostic properties. Patients treated with antimicrobial therapy display false-negative 99mTc-HMPAO-SPECT/CT results more often, especially if intravenous, definite, or combination regimens are administered.


Assuntos
Anti-Infecciosos , Endocardite Bacteriana , Endocardite , Adulto , Humanos , Tecnécio Tc 99m Exametazima , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Leucócitos
18.
J Electrocardiol ; 72: 1-5, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35219111

RESUMO

Algorithms designed to reduce the right ventricular (RV) pacing burden are widely available in modern dual-chamber implantable pacing devices. These algorithms allow the atrioventricular delay for sensed ventricular events to be longer than for ventricular paced events. However, since these features are unique to pacemaker manufacturers, they often produce unfamiliar electrocardiographic (ECG) appearances that suggest pacemaker dysfunction. We describe a Vp suppression algorithm used in Biotronik dual-chamber pacemakers and implantable cardioverter-defibrillator devices.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Algoritmos , Estimulação Cardíaca Artificial , Eletrocardiografia , Ventrículos do Coração , Humanos
19.
Acta Cardiol ; 77(2): 114-121, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34006173

RESUMO

In patients with significantly impaired left ventricle function permanent atrial fibrillation (AF) often coexists with symptoms of heart failure. Based on various studies, it is assumed that in patients with heart failure in functional class III and IV AF occurs in 40-50% of patients. AF adversely affects cardiac hemodynamics, and its harmfulness increases particularly in the failing heart. The lack of mechanical function of the left atrium, the usually fast ventricular rate and the irregular sequence of ventricular contraction constitute the spectrum of harmful effects of this arrhythmia. Therefore, the only way to address the underlying problem of AF, which is irregular ventricular rhythm, is to pace the ventricles and to slow or block the AV conduction. Classic, right ventricular pacing is contraindicated in this population as it promotes the abovementioned disorders by initiating additional dyssynchrony of left ventricular contraction with reduction of its contractility and aggravation of AF-related mitral regurgitation. The possibility of direct His bundle pacing (DHBP) significantly extended the clinical armamentarium of cardiac pacing. The restoration of the physiological electrical activation could significantly contribute to echocardiographic and clinical improvement. With time and the development of dedicated tools for direct His bundle pacing the success rate of implantations became more than 90% and the acceptable pacing thresholds under 2.0 V (1 ms) could be achieved in most patients. This contributed to the broader clinical application of DHBP in different patient' groups with various pacing indications. The authors of the paper discuss different electrocardiographic and clinical indications for DHBP.


Assuntos
Fibrilação Atrial/terapia , Fascículo Atrioventricular/fisiologia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Fibrilação Atrial/complicações , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/fisiopatologia , Humanos , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 44(1): 148-150, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33165971

RESUMO

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. We present an interesting ECG with a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with atrial fibrillation, pacing beats, ventricular ectopic beats, and couple of ventricular beats. This report shows unexceptional occurrence of tricky ECG finding in patient with Biotronik ICDs.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Impedância Elétrica , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA