Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Hyperthermia ; 35(1): 44-55, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29806513

RESUMO

PURPOSE: This study evaluates the effects of active electrode cooling, via internal fluid circulation, on the irreversible electroporation (IRE) lesion, deployed electric current and temperature changes using a perfused porcine liver model. MATERIALS AND METHODS: A bipolar electrode delivered IRE electric pulses with or without activation of internal cooling to nine porcine mechanically perfused livers. Pulse schemes included a constant voltage, and a preconditioned delivery combined with an arc-mitigation algorithm. After treatment, organs were dissected, and treatment zones were stained using triphenyl-tetrazolium chloride (TTC) to demonstrate viability. RESULTS: Thirty-nine treatments were performed with an internally cooled applicator and 21 with a non-cooled applicator. For the constant voltage scenario, the average final electrical current measured was 26.37 and 29.20 A for the cooled and uncooled electrodes respectively ([Formula: see text]). The average final temperature measured was 33.01 and 42.43 °C for the cooled and uncooled electrodes respectively ([Formula: see text]). The average measured ablations (fixed lesion) were 3.88-by-2.08 cm and 3.86-by-2.12 cm for the cooled and uncooled electrode respectively ([Formula: see text], [Formula: see text]). Similarly, the preconditioned/arc-mitigation scenario yielded an average final electrical current measurement of a 41.07 and 47.20 A for the cooled and uncooled electrodes respectively ([Formula: see text]). The average final temperature measured was 34.93 and 44.90 °C for the cooled and uncooled electrodes respectively ([Formula: see text]). The average measured ablations (fixed lesion) were 3.67-by-2.27 cm and 3.58-by-2.09 cm for the cooled and uncooled applicators ([Formula: see text]). CONCLUSIONS: The internally-cooled bipolar applicator offers advantages that could improve clinical outcomes. Thermally mitigating internal perfusion technology reduced tissue temperatures and electric current while maintaining similar lesion sizes.


Assuntos
Técnicas de Ablação/métodos , Eletroporação/métodos , Fígado/cirurgia , Animais , Temperatura Baixa , Modelos Animais de Doenças , Eletrodos , Fígado/patologia , Suínos
2.
J Vasc Interv Radiol ; 27(12): 1913-1922.e2, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27663353

RESUMO

PURPOSE: To develop and validate a perfused organ model for characterizing ablations for irreversible electroporation (IRE)-based therapies. MATERIALS AND METHODS: Eight excised porcine livers were mechanically perfused with a modified phosphate-buffered saline solution to maintain viability during IRE ablation. IRE pulses were delivered using 2 monopolar electrodes over a range of parameters, including voltage (1,875-3,000 V), pulse length (70-100 µsec), number of pulses (50-600), electrode exposure (1.0-2.0 cm), and electrode spacing (1.5-2.0 cm). Organs were dissected, and treatment zones were stained with triphenyl tetrazolium chloride to demonstrate viability and highlight the area of ablation. Results were compared with 17 in vivo ablations performed in canine livers and 35 previously published ablations performed in porcine livers. RESULTS: Ablation dimensions in the perfused model correlated well with corresponding in vivo ablations (R2 = 0.9098) with a 95% confidence interval of < 2.2 mm. Additionally, the validated perfused model showed that the IRE ablation zone grew logarithmically with increasing pulse numbers, showing small difference in ablation size over 200-600 pulses (3.2 mm ± 3.8 width and 5.2 mm ± 3.9 height). CONCLUSIONS: The perfused organ model provides an alternative to animal trials for investigation of IRE treatments. It may have an important role in the future development of new devices, algorithms, and techniques for this therapy.


Assuntos
Técnicas de Ablação , Eletroporação , Fígado/cirurgia , Perfusão , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/instrumentação , Animais , Cães , Eletrodos , Eletroporação/instrumentação , Desenho de Equipamento , Técnicas In Vitro , Modelos Lineares , Fígado/patologia , Masculino , Especificidade da Espécie , Suínos , Sobrevivência de Tecidos
3.
Am J Physiol Heart Circ Physiol ; 310(9): H1129-39, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-26945081

RESUMO

Our laboratory previously demonstrated that perfusate sodium and potassium concentrations can modulate cardiac conduction velocity (CV) consistent with theoretical predictions of ephaptic coupling (EpC). EpC depends on the ionic currents and intercellular separation in sodium channel rich intercalated disk microdomains like the perinexus. We suggested that perinexal width (WP) correlates with changes in extracellular calcium ([Ca(2+)]o). Here, we test the hypothesis that increasing [Ca(2+)]o reduces WP and increases CV. Mathematical models of EpC also predict that reducing WP can reduce sodium driving force and CV by self-attenuation. Therefore, we further hypothesized that reducing WP and extracellular sodium ([Na(+)]o) will reduce CV consistent with ephaptic self-attenuation. Transmission electron microscopy revealed that increasing [Ca(2+)]o (1 to 3.4 mM) significantly decreased WP Optically mapping wild-type (WT) (100% Cx43) mouse hearts demonstrated that increasing [Ca(2+)]o increases transverse CV during normonatremia (147.3 mM), but slows transverse CV during hyponatremia (120 mM). Additionally, CV in heterozygous (∼50% Cx43) hearts was more sensitive to changes in [Ca(2+)]o relative to WT during normonatremia. During hyponatremia, CV slowed in both WT and heterozygous hearts to the same extent. Importantly, neither [Ca(2+)]o nor [Na(+)]o altered Cx43 expression or phosphorylation determined by Western blotting, or gap junctional resistance determined by electrical impedance spectroscopy. Narrowing WP, by increasing [Ca(2+)]o, increases CV consistent with enhanced EpC between myocytes. Interestingly, during hyponatremia, reducing WP slowed CV, consistent with theoretical predictions of ephaptic self-attenuation. This study suggests that serum ion concentrations may be an important determinant of cardiac disease expression.


Assuntos
Potenciais de Ação , Sinalização do Cálcio , Cálcio/metabolismo , Comunicação Celular , Modelos Cardiovasculares , Miócitos Cardíacos/metabolismo , Sódio/metabolismo , Animais , Simulação por Computador , Conexina 43/deficiência , Conexina 43/genética , Espectroscopia Dielétrica , Impedância Elétrica , Junções Comunicantes/metabolismo , Genótipo , Hiponatremia/sangue , Hiponatremia/fisiopatologia , Preparação de Coração Isolado , Cinética , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica de Transmissão , Miócitos Cardíacos/ultraestrutura , Fenótipo , Imagens com Corantes Sensíveis à Voltagem
4.
Cancer Lett ; 380(1): 330-9, 2016 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-26724680

RESUMO

Tumors are highly heterogeneous at the patient, tissue, cellular, and molecular levels. This multi-scale heterogeneity poses significant challenges for effective therapies, which ideally must not only distinguish between tumorous and healthy tissue, but also fully address the wide variety of tumorous sub-clones. Commonly used therapies either leverage a biological phenotype of cancer cells (e.g. high rate of proliferation) or indiscriminately kill all the cells present in a targeted volume. Tumor microenvironment (TME) targeting represents a promising therapeutic direction, because a number of TME hallmarks are conserved across different tumor types, despite the underlying genetic heterogeneity. Historically, TME targeting has largely focused on the cells that support tumor growth (e.g. vascular endothelial cells). However, by viewing the intrinsic physical and chemical alterations in the TME as additional therapeutic opportunities rather than barriers, a new class of TME-inspired treatments has great promise to complement or replace existing therapeutic strategies. In this review we summarize the physical and chemical hallmarks of the TME, and discuss how these tumor characteristics either currently are, or may ultimately be targeted to improve cancer therapies.


Assuntos
Técnicas de Ablação , Antineoplásicos/administração & dosagem , Sistemas de Liberação de Medicamentos , Neoplasias/terapia , Microambiente Tumoral , Técnicas de Ablação/métodos , Animais , Portadores de Fármacos , Sistemas de Liberação de Medicamentos/métodos , Resistencia a Medicamentos Antineoplásicos , Humanos , Concentração de Íons de Hidrogênio , Neoplasias/metabolismo , Neoplasias/patologia , Hipóxia Tumoral
5.
Biophys J ; 110(2): 503-513, 2016 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-26789772

RESUMO

The blood-brain barrier, mainly composed of brain microvascular endothelial cells, poses an obstacle to drug delivery to the brain. Controlled permeabilization of the constituent brain endothelial cells can result in overcoming this barrier and increasing transcellular transport across it. Electroporation is a biophysical phenomenon that has shown potential in permeabilizing and overcoming this barrier. In this study we developed a microengineered in vitro model to characterize the permeabilization of adhered brain endothelial cells to large molecules in response to applied pulsed electric fields. We found the distribution of affected cells by reversible and irreversible electroporation, and quantified the uptaken amount of naturally impermeable molecules into the cells as a result of applied pulse magnitude and number of pulses. We achieved 81 ± 1.7% (N = 6) electroporated cells with 17 ± 8% (N = 5) cell death using an electric-field magnitude of ∼580 V/cm and 10 pulses. Our results provide the proper range for applied electric-field intensity and number of pulses for safe permeabilization without significantly compromising cell viability. Our results demonstrate that it is possible to permeabilize the endothelial cells of the BBB in a controlled manner, therefore lending to the feasibility of using pulsed electric fields to increase drug transport across the BBB through the transcellular pathway.


Assuntos
Barreira Hematoencefálica/metabolismo , Permeabilidade Capilar , Eletroporação/métodos , Células Endoteliais/metabolismo , Animais , Linhagem Celular , Eletroporação/instrumentação , Camundongos , Microfluídica/instrumentação , Microfluídica/métodos
6.
IEEE Trans Biomed Eng ; 62(11): 2674-84, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26057529

RESUMO

SIGNIFICANCE: Irreversible electroporation (IRE) is gaining popularity as a focal ablation modality for the treatment of unresectable tumors. One clinical limitation of IRE is the absence of methods for real-time treatment evaluation, namely actively monitoring the dimensions of the induced lesion. This information is critical to ensure a complete treatment and minimize collateral damage to the surrounding healthy tissue. GOAL: In this study, we are taking advantage of the biophysical properties of living tissues to address this critical demand. METHODS: Using advanced microfabrication techniques, we have developed an electrical impedance microsensor to collect impedance data along the length of a bipolar IRE probe for treatment verification. For probe characterization and interpretation of the readings, we used potato tuber, which is a suitable platform for IRE experiments without having the complexities of in vivo or ex vivo models. We used the impedance spectra, along with an electrical model of the tissue, to obtain critical parameters such as the conductivity of the tissue before, during, and after completion of treatment. To validate our results, we used a finite element model to simulate the electric field distribution during treatments in each potato. RESULTS: It is shown that electrical impedance spectroscopy could be used as a technique for treatment verification, and when combined with appropriate FEM modeling can determine the lesion dimensions. CONCLUSIONS: This technique has the potential to be readily translated for use with other ablation modalities already being used in clinical settings for the treatment of malignancies.


Assuntos
Técnicas de Ablação/instrumentação , Espectroscopia Dielétrica/instrumentação , Eletroquimioterapia/instrumentação , Técnicas de Ablação/métodos , Espectroscopia Dielétrica/métodos , Eletroquimioterapia/métodos , Eletrodos , Desenho de Equipamento , Estudos de Viabilidade , Análise de Elementos Finitos , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA