Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
J Dent ; 148: 105151, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38909644

RESUMO

OBJECTIVES: The present study aimed to evaluate the trueness and precision of monolithic zirconia crowns (MZCs) fabricated by 3D printing and milling techniques. METHODS: A premolar crown was designed after scanning a prepared typodont. Twenty MZCs were fabricated using milling and 3D-printing techniques (n = 10). All the specimens were scanned with an industrial scanner, and the scanned data were analyzed using 3D measurement software to evaluate the trueness and precision of each group. Root mean square (RMS) deviations were measured and statistically analyzed (One-way ANOVA, Tukey's, p ≤ 0.05). RESULTS: The trueness of the printed MZC group (140 ± 14 µm) showed a significantly higher RMS value compared to the milled MZCs (96 ± 27 µm,p < 0.001). At the same time, the precision of the milled MZCs (61 ± 17 µm) showed a significantly higher RMS value compared to that of the printed MZCs (31 ± 5 µm,p < 0.001). CONCLUSIONS: The Fabrication techniques had a significant impact on the accuracy of the MZCs. Milled MZCs showed the highest trueness, while printed MZCs showed the highest precision. All the results were within the clinically acceptable error values. CLINICAL SIGNIFICANCE: Although the trueness of the milled MZCs is higher, the manufacturing accuracy of the 3D-printed MZCs showed clinically acceptable results in terms of trueness and precision. However, additional clinical studies are recommended. Furthermore, the volumetric changes of the material should be considered.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Impressão Tridimensional , Zircônio , Zircônio/química , Humanos , Planejamento de Prótese Dentária/métodos , Materiais Dentários/química , Dente Pré-Molar , Propriedades de Superfície , Teste de Materiais
2.
Orthod Craniofac Res ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38887908

RESUMO

OBJECTIVES: Investigating the impact of thermal and mechanical loading on the force generation of orthodontic aligners made from various thermoplastic materials and different compositions. MATERIALS AND METHODS: Five distinct materials were utilized including, three multi-layer (Zendura FLX, Zendura VIVA, CA Pro) and two single-layer (Zendura A and Duran). A total of 50 thermoformed aligners (n = 10) underwent a 48-hour ageing protocol, which involved mechanical loading resulting from a 0.2 mm facial malalignment of the upper right central incisor (Tooth 11) and thermal ageing through storage in warm distilled water at 37°C. The force exerted on Tooth 11 of a resin model was measured both before and after ageing using pressure-sensitive films and a biomechanical setup. RESULTS: Before ageing, pressure-sensitive films recorded normal contact forces ranging from 83.1 to 149.7 N, while the biomechanical setup measured resultant forces ranging from 0.1 to 0.5 N, with lingual forces exceeding facial forces. Multi-layer materials exhibited lower force magnitudes compared to single-layer materials. After ageing, a significant reduction in force was observed, with some materials experiencing up to a 50% decrease. Notably, multi-layer materials, especially Zendura VIVA, exhibited lower force decay. CONCLUSIONS: The force generated by aligners is influenced by both the aligner material and the direction of movement. Multi-layer materials exhibit superior performance compared to single-layer materials, primarily because of their lower initial force, which enhances patient comfort, and their capability to maintain consistent force application even after undergoing ageing.

3.
Materials (Basel) ; 17(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38930391

RESUMO

This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (µ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement.

4.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807109

RESUMO

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Dureza , Teste de Materiais , Cerâmica/química , Silicatos de Alumínio/química , Análise do Estresse Dentário , Propriedades de Superfície , Cristalização
5.
Clin Oral Implants Res ; 35(8): 864-875, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38629760

RESUMO

OBJECTIVES: This study investigates effects of surgical guide manufacturing process on 3D transfer accuracy of planned dental implant position, using three production methods: additive 3D-printed (3DF), subtractive milled (MF), and analog laboratory fabricated templates (LF). MATERIAL AND METHODS: Implant position for a single-tooth gap (#26) planned digitally. 3DF and MF templates were designed digitally, while LF templates were analogously created. For each manufacturing type, 10 surgical guides were fabricated. Each guide was used for template-guided implant placement in model replicas. For evaluation of implant placement, cone beam computed tomography scans of all implanted models were superimposed, and implant positions were determined. Deviations at implant shoulder/apex were measured, and median and inter-quartile range (IQR) were determined for mesio-distal, oro-facial, coronal apico, 3D spaces, and angles. RESULTS: At implant shoulder, vertical components dominated position deviations (up to 1.04 mm, IQR 0.28 mm for 3DF). Horizontal deviations were much lower (mesio-distally up to 0.38 mm, IQR 0.36 mm (LF)). Implant apex shows similar vertical deviations, while horizontal deviations clearly increased compared to shoulder, especially in mesio-distal direction. Median angular deviations were between 2.1° (IQR 2.0 mm, max. 4.2°) for 3DF and 3.3° (IQR 1.9 mm, max. 5.3°) for MF. No statistical differences were found between manufacturing types (Kruskal-Wallis test, p = .05). CONCLUSIONS: The study showed the method of implant guide fabrication did not affect the accuracy of implant placement within the limits of an in vitro environment. All methods resulted in implant placement which did not exceed the accepted safety deviation envelope (1.5-2.0 mm).


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Impressão Tridimensional , Humanos , Implantação Dentária Endóssea/métodos , Técnicas In Vitro , Cirurgia Assistida por Computador/métodos , Implantes Dentários , Desenho Assistido por Computador
6.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622680

RESUMO

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Assuntos
Implantes Dentários , Zircônio , Humanos , Análise de Elementos Finitos , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Estresse Mecânico
7.
Materials (Basel) ; 17(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38591373

RESUMO

The aim of this study was to assess the effect of body temperature (37 °C) on the cyclic fatigue resistance of three endodontic single-file systems using a new testing setup. One Shape® new generation (OS), WaveOne™ (WO) and WaveOne® GOLD (WOG), which are made from different NiTi alloys and operated in different motions (rotation/reciprocation), were evaluated. The study design included four groups. Each group comprised 30 files, 10 files of each of the three file systems, tested at 20 ± 2 °C (group 1 and 3) and at 37 ± 1 °C (group 2 and 4). All files were tested in a custom-made metal block with artificial canals of 60° angle, and a 5 mm and 3 mm radius of curvature, respectively. A heating element was attached to replicate a temperature of 37 °C. Files were introduced 18 mm into the canals and operated until failure. Transformation temperatures of five samples of each of the tested file systems were determined via the bend and free recovery (BFR) method. With the exception of WOG in canals with a 3 mm radius of curvature (p = 0.075), all the tested file systems showed statistically significantly less time needed to fracture when operated at 37 ± 1 °C compared to at 20 ± 2 °C in canals with a 5 mm and 3 mm radius of curvature using Mann-Whitney U test (p < 0.05). All file systems showed transformation temperatures below the body temperature. We concluded that body temperature directly affects the cyclic fatigue resistance of all tested file systems. Bend and free recovery can be suitable for the determination of austenite finish temperatures (Af) of endodontic instruments as it allows testing a longer portion of the instrument.

8.
J Clin Med ; 13(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38592077

RESUMO

OBJECTIVES: Aligners are an effective and esthetic orthodontic treatment option for permanent and mixed dentition. There are only a few studies dealing with the effectiveness of orovestibular tooth movement using aligners and applying adequate examination methods. In the present retrospective study, the aligner efficiency of orovestibular movements for the entire dentition was systematically evaluated using 3D superimposition, taking into account the influence of jaw, tooth type and Invisalign® system. METHODS: Group 1 (n = 18 adults, Invisalign®) and Group 2 (n = 17 adolescents, Invisalign® Teen) were treated with Invisalign® Ex30 aligner material and Invisalign® specific auxiliary means. In this non-interventional retrospective study, pre- and post-treatment maxillary and mandibular plaster cast models were scanned and superimposed with ClinChecks® via Surface-Surface Matching Algorithm on unmoved teeth providing stable references. Effectivity of planned versus clinically realized movements was evaluated for each tooth. Statistics were performed with a t-test and Bonferroni-Holm correction (α = 0.05). RESULTS: Orovestibular movement efficiency was excellent without statistical significance regarding jaw, tooth type or Invisalign® system. Mandibular translational tooth movements were highly effective, and outstanding for premolars (91-98%). Maxillary translational tooth movements were successful for incisors and premolars, but less effective for canines and molars. Almost all teeth were moderately or very effectively corrected by crown tipping, performing better for mandibular (70-92%) than maxillary (22-31%) canines as much as for adolescent upper front teeth (81-85%) and lower canines (92%). CONCLUSIONS: Aligners are able to effectively implement translational orovestibular movements, supported by tilting the crowns for even more efficient implementation of the movements. This phenomenon was observed in our studies for all teeth in both jaws, regardless of the Invisalign® system used. Treatment planning should nevertheless take into account the individual patient parameters with regard to the movements to be performed in order to make the aligner therapy as successful as possible in terms of realizing the desired therapeutic goal.

9.
J Orofac Orthop ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653792

RESUMO

PURPOSE: The aim was to investigate the effect of aging by thermocycling and mechanical loading on forces and moments generated by orthodontic clear aligners made from different thermoplastic materials. METHODS: A total of 25 thermoformed aligners made from 5 different materials, i.e., Essix ACE® and Essix® PLUS™ (Dentsply Sirona, Bensheim, Germany), Invisalign® (Align Technology, San Jose, CA, USA), Duran®+ (Iserlohn, Germany), Zendura™ (Fremont, CA, USA), underwent a 14-day aging protocol involving mechanical loading (a 0.2 mm vestibular malalignment of the upper left second premolar [tooth 25]) and thermocycling in deionized water (temperature range 5-55 °C). The 3D forces/moments exerted on tooth 25 of a resin model were measured at three time points: before aging (day 0), after 2 days and after 14 days of aging. RESULTS: Before aging, extrusion-intrusion forces were 0.6-3.0 N, orovestibular forces were 1.7-2.3 N, and moments as mesiodistal rotation were 0.3-42.1 Nmm. In all directions, multilayer Invisalign® exhibited the lowest force/moment magnitudes. After aging, all materials showed a significant force/moment decay within the first 2 days, except Invisalign® for orovestibular and vertical translation. However, following thermomechanical aging, Duran®+ and Zendura™ aligners had equivalent or even higher vestibular forces (direction of mechanical load). CONCLUSION: Thermomechanical aging significantly reduced forces and moments during the first 48 h. Multilayer aligner materials exhibit lower initial forces and moments than single-layer ones, and were less influenced by aging. Material hardening was observed after subjecting some of the aligner materials to mechanical loading. Thus, orthodontists should be aware of possible deterioration of orthodontic aligners over time. This work also sheds light on how material selection impacts the mechanical behavior of aligners and may provide valuable guidance regarding optimal timing for the aligner changing protocol.

10.
J Clin Med ; 13(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38673571

RESUMO

Background: The attainment of precise posterior occlusion alignment necessitates a deeper understanding of the clinical efficacy of aligner therapy. This study aims to determine whether the treatment goals defined in the virtual planning of aligner therapy are effectively implemented in clinical practice, with a particular focus on the influence of distalization distances on potential vertical side effects. Methods: In this retrospective, non-interventional investigation, a cohort of 20 individuals undergoing Invisalign® treatment was examined. Pre- and post-treatment maxillary clinical and ClinCheck® casts were superimposed utilizing a surface-surface matching algorithm on palatal folds, median palatine raphe, and unmoved teeth as the stable references. The effectivity of planned versus clinical movements was evaluated. Groupings were based on distalization distances, planned vertical movements, and Class II elastic prescription. Statistics were performed with a two-sample t-test and p-value < 0.05. Results: Clinically achieved distalization was significantly lower than virtually planned distalization, regardless of additional vertical movements, where a lack of implementation was contingent upon the extent of distalization, with no mitigating effects observed with the application of Class II elastics. Intriguingly, no adverse vertical side effects were noted; however, the intended intrusions or extrusions, as per the therapeutic plans, remained unattainable regardless of the magnitude of distalization. Conclusions: These findings underscore the imperative for future investigations to delve deeper into the intricacies surrounding translational mesio-distal and vertical movements, thereby enhancing predictability within orthodontic practice. To facilitate successful clinical implementation of vertical and translational movements via aligners, the incorporation of sliders emerges as a promising strategy for bolstering anchorage reinforcement.

11.
Clin Oral Investig ; 28(5): 258, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637429

RESUMO

OBJECTIVES: To investigate the effects of material type and thickness on force generation and distribution by aligners. MATERIALS AND METHODS: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. RESULTS: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. CONCLUSIONS: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. CLINICAL RELEVANCE: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Humanos , Fenômenos Biomecânicos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos
12.
Orthod Craniofac Res ; 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459802

RESUMO

OBJECTIVES: To use the finite element method (FEM) to investigate the effect of various attachment configurations and trimming line designs of orthodontic aligners on their biomechanical performance. METHOD: A 3D upper jaw model was imported into 3D design software. The upper right central incisor tooth (Tooth 11) was made mobile, and its periodontal ligament (PDL) and bone structures were designed. Aligners were modelled with three distinct attachment configurations: No attachment, rectangular horizontal, rectangular vertical, and two trimming line designs; scalloped and straight extended, with a homogeneous thickness of 0.6 mm. These models were then imported into an FE software. Simulations were conducted for three different movements, including facial translation, distalization, and extrusion. RESULTS: Forces were recorded at 1.3-2.6 N during facial translation, 1.4-5.9 N in distalization, and 0.0-2.0 N in extrusion. The straight extended trimming line consistently generated higher forces than the scalloped design. Attachments had no significant impact on force components during facial translation but were more effective in distalization and extrusion. The combination of a straight extended trimming line with horizontal attachments exhibited the least stresses at the apical third during distalization, and the highest stresses during extrusion, suggesting superior retention. CONCLUSIONS: Rectangular attachments offer limited benefits in facial translation, but horizontal rectangular attachments can intensify load in distalization and are crucial for force generation in extrusion. Horizontal attachments are preferred over vertical options. Additionally, the straight extended trim line enhances control of tooth movement and can replace attachments in certain cases. CLINICAL RELEVANCE: These findings provide biomechanical evidence and an optimal protocol to guide clinical practice in planning diverse teeth movements. The emphasis is on the influence of attachment utilization and the specific design of aligner trimming lines to enhance control over tooth movement.

13.
J Orofac Orthop ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345616

RESUMO

PURPOSE: Using a commercial orthodontic treatment planning system, tooth movements were simulated to analyse how precise predefined movements can be determined by three different superimposition methods. Additionally, a retrospective analysis on clinical patient models before and after orthodontic treatment was performed to analyse possible differences in determination of clinical tooth movements with these methods. METHODS: (1) A hexapod system was used to perform the tooth movements in physical maxillary dental models (N = 70). The initial and final situations were scanned, superimpositions executed, movements calculated, and their accuracy compared to the predefined movements was determined. (2) Digital three-dimensional (3D) maxillary dental models representing pre- and postorthodontic treatment situations (N = 100 patients) were superimposed. Selected tooth movements were calculated (N = 3600), and the results of the different superimposition methods were compared pairwise. RESULTS: (1) The experimental study delivered only small location and scale shifts. Furthermore, concordance correlation coefficients above 0.99 for all three methods. This verified that all methods deliver values corresponding well to the predefined movements. (2) The retrospective analysis of the clinically performed orthodontic tooth movements comparing pairwise the three different methods intraindividually also showed small location and scale shifts. Furthermore, concordance correlation coefficients between 0.68 and 0.98 were observed, with only three of them below 0.8. This verified that the applied superimposition methods delivered values sufficiently close to each other. CONCLUSIONS: As the experimental study showed very good agreement between the predefined and determined movements, and as the retrospective clinical study showed that the methods compared pairwise delivered values close to each other for the performed orthodontic tooth movements, it can be concluded that orthodontic tooth movements can be determined adequately correct by each of the examined methods.

14.
J World Fed Orthod ; 13(2): 65-71, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38395726

RESUMO

BACKGROUND: A finite element model was used to investigate the effect of different designs and thicknesses of orthodontic aligner margins on their biomechanical behavior. METHODS: A three-dimensional data set of an upper jaw was imported into the 3-matic software. The upper right central incisor tooth (Tooth 11) was separated from the remaining model, and its periodontal ligament and surrounding bone were designed. Aligners were designed with four different trimming lines (scalloped, straight, scalloped extended, straight extended), each with four different thicknesses (0.3, 0.4, 0.5, and 0.6 mm). The models were imported into a finite element package (Marc/Mentat). A linear elastic constitutive material model was applied. A facial 0.2 mm bodily malalignment of tooth 11 was simulated. RESULTS: The maximum resultant force was in the range of 1.0 N to 2.2 N. The straight trimming designs deliver higher resultant forces compared with scalloped trimming designs. Increasing the aligner thickness and/or extending the aligner edge beyond the gingival line leads to an increase in the resultant force. All designs showed an uneven distribution of the normal contact forces over the tooth surface with a predominant concentration toward the cervical third and distal third, particularly with the extended trimming designs. All designs showed uncontrolled tipping of the tooth. CONCLUSIONS: Based on the current model outcomes, the use of a straight extended trimming line design for aligners is favored because of its positive impact on force distribution and, consequently, the control of tooth movement. CLINICAL RELEVANCE: These findings provide aligner companies and orthodontists a valuable biomechanical evidence and guidance to enhance control over tooth movement and therefore optimize treatment outcomes. This can be achieved by trimming the edges of aligners with a straight extended design and selecting the appropriate aligner thickness.


Assuntos
Fenômenos Mecânicos , Desenho de Aparelho Ortodôntico , Análise de Elementos Finitos , Software , Maxila , Técnicas de Movimentação Dentária/métodos
15.
BMC Oral Health ; 24(1): 99, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233794

RESUMO

BACKGROUND: While conventional threaded implants (TI) have proven to be effective for replacing missing teeth, they have certain limitations in terms of diameter, length, and emergence profile when compared to customised root analogue implants (RAI). To further investigate the potential benefits of RAIs, the aim of this study was to experimentally evaluate the micromotion of RAIs compared to TIs. METHODS: A 3D model of tooth 47 (mandibular right second molar) was segmented from an existing cone beam computed tomography (CBCT), and a RAI was designed based on this model. Four RAI subgroups were fabricated as follows: 3D-printed titanium (PT), 3D-printed zirconia (PZ), milled titanium (MT), milled zirconia (MZ), each with a sample size of n = 5. Additionally, two TI subgroups (B11 and C11) were used as control, each with a sample size of n = 5. All samples were embedded in polyurethane foam artificial bone blocks and subjected to load application using a self-developed biomechanical Hexapod Measurement System. Micromotion was quantified by analysing the load/displacement curves. RESULTS: There were no statistically significant differences in displacement in Z-axis (the loading direction) between the RAI group and the TI group. However, within the RAI subgroups, PZ exhibited significantly higher displacement values compared to the other subgroups (p < 0.05). In terms of the overall total displacement, the RAI group showed a statistically significant higher displacement than the TI group, with mean displacement values of 96.5 µm and 55.8 µm for the RAI and TI groups, respectively. CONCLUSIONS: The RAI demonstrated promising biomechanical behaviour, with micromotion values falling within the physiological limits. However, their performance is less predictable due to varying anatomical designs.


Assuntos
Implantes Dentários , Humanos , Titânio , Zircônio , Software
16.
J Mech Behav Biomed Mater ; 150: 106337, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38154364

RESUMO

OBJECTIVES: To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. MATERIALS AND METHODS: Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). RESULTS: DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. CONCLUSIONS: TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. CLINICAL RELEVANCE: The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.


Assuntos
Materiais Inteligentes , Fenômenos Mecânicos , Vidro , Temperatura de Transição , Impressão Tridimensional
17.
J Mater Sci Mater Med ; 34(11): 60, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37962680

RESUMO

Half a million different plant species are occurring worldwide, of which only 1% has been phytochemically considered. Thus, there is great potential for discovering novel bioactive compounds. In dentistry, herbal extracts have been used as antimicrobial agents, analgesics, and intracanal medicaments. Glass-ionomer cement (GIC) and bioactive glass (BAG) are attractive materials in dentistry due to their bioactivity, adhesion, and remineralisation capabilities. Thus, this review summarizes the evidence around the use of phytotherapeutics in dental glass-based materials. This review article covers the structure, properties, and clinical uses of GIC and BAG materials within dentistry, with an emphasis on all the attempts that have been made in the last 20 years to enhance their properties naturally using the wisdom of traditional medicines. An extensive electronic search was performed across four databases to include published articles in the last 20 years and the search was concerned only with the English language publications. Publications that involved the use of plant extracts, and their active compounds for the green synthesis of nanoparticles and the modification of GIC and BAG were included up to May 2023. Plant extracts are a potential and effective candidate for modification of different properties of GIC and BAG, particularly their antimicrobial activities. Moreover, natural plant extracts have shown to be very effective in the green synthesis of metal ion nanoparticles in an ecological, and easy way with the additional advantage of a synergistic effect between metal ions and the phytotherapeutic agents. Medicinal plants are considered an abundant, cheap source of biologically active compounds and many of these phytotherapeutics have been the base for the development of new lead pharmaceuticals. Further research is required to assess the safety and the importance of regulation of phytotherapeutics to expand their use in medicine.


Assuntos
Medicina Herbária , Nanopartículas Metálicas , Extratos Vegetais , Cimentos de Ionômeros de Vidro , Odontologia
18.
Dent Res J (Isfahan) ; 20: 100, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020252

RESUMO

Background: This study compared the effect of various grafting materials on the area and volume of minerals attached to dental implants. Materials and Methods: In this animal study, 13 dogs were divided into three groups according to the time of sacrificing (2 months, 4 months, or 6 months). The implants were placed in oversized osteotomies, and the residual defects were filled with autograft, bovine bone graft (Cerabone), or a synthetic substitute (Osteon II). At the designated intervals, the dogs were sacrificed and the segmented implants underwent micro-computed tomography analysis. The bone-implant area (BIA) and bone-implant volume (BIV) of bone and graft material were calculated in the region of interest around the implant. The data were analyzed by two-way analysis of variance (ANOVA) at P < 0.05. Results: There was no significant difference in BIA and BIV between the healing intervals for any of the grafting materials (P > 0.05). ANOVA exhibited comparable BIA and BIV between the grafting materials at 2 and 4 months after surgery (P > 0.05), although a significant difference was observed after 6 months (P < 0.05). Pairwise comparisons revealed that BIA was significantly greater in the autograft-stabilized than the synthetic-grafted sites (P = 0.035). The samples augmented with autograft also showed significantly higher BIV than those treated by the xenogenic (P = 0.017) or synthetic (P = 0.002) particles. Conclusion: All graft materials showed comparable performance in providing mineral support for implants up to 4 months after surgery. At the long-term (6-month) interval, autogenous bone demonstrated significant superiority over xenogenic and synthetic substitutes concerning the bone area and volume around the implant.

19.
Clin Oral Investig ; 27(11): 6677-6688, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37775587

RESUMO

OBJECTIVES: Disinfection of alginate impression materials is a mandatory step to prevent cross-infection in dental clinics. However, alginate disinfection methods are time-consuming and exert a negative impact on accuracy and mechanical properties. Thus, this study aimed to prepare disinfecting agents (CHX and AgNO3) and silver nanoparticles reduced by a natural plant extract to produce a self-disinfecting dental alginate. METHODS: Conventional alginate impression material was used in this study. Silver nitrate (0.2% AgNO3 group) and chlorohexidine (0.2% CHX group) solutions were prepared using distilled water, and these solutions were later employed for alginate preparation. Moreover, a 90% aqueous plant extract was prepared from Boswellia sacra (BS) oleoresin and used to reduce silver nitrate to form silver nanoparticles that were incorporated in the dental alginate preparation (BS+AgNPs group). The plant extract was characterized by gas chromatography/mass spectrometry (GC/MS) analysis while green-synthesized silver nanoparticles (AgNPs) were characterized by UV-visible (UV-vis) spectroscopy and scanning electron microscopy (SEM). An agar disc diffusion assay was used to test the antimicrobial activity against Candida albicans, Streptococcus mutans, Escherichia coli, methicillin-resistant and susceptible Staphylococcus aureus strains, and Micrococcus luteus. Agar plates were incubated at 37 ± 1 °C for 24 h to allow microbial growth. Diameters of the circular inhibition zones formed around each specimen were measured digitally by using ImageJ software. RESULTS: Chemical analysis of the plant extract revealed the presence of 41 volatile and semi-volatile active compounds. UV-Vis spectrophotometry, SEM, and EDX confirmed the formation of spherical silver nanoparticles using the BS extract. CHX, AgNO3, and the BS+AgNPs modified groups showed significantly larger inhibition zones than the control group against all tested strains. BS+AgNPs and CHX groups showed comparable efficacy against all tested strains except for Staphylococcus aureus, where the CHX-modified alginate had a significantly higher effect. CONCLUSIONS AND CLINICAL RELEVANCE: CHX, silver nitrate, and biosynthesized silver nanoparticles could be promising inexpensive potential candidates for the preparation of a self-disinfecting alginate impression material without affecting its performance. Green synthesis of metal nanoparticles using Boswellia sacra extract could be a very safe, efficient, and nontoxic way with the additional advantage of a synergistic action between metal ions and the phytotherapeutic agents of the plant extract.


Assuntos
Alginatos , Nanopartículas Metálicas , Alginatos/farmacologia , Desinfecção , Nitrato de Prata/farmacologia , Nanopartículas Metálicas/química , Ágar/farmacologia , Cromatografia Gasosa-Espectrometria de Massas , Prata , Extratos Vegetais/farmacologia , Staphylococcus aureus , Nanotecnologia/métodos , Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana
20.
J Mech Behav Biomed Mater ; 146: 106102, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37660448

RESUMO

OBJECTIVES: Lithium disilicate (LDS) based glass ceramics are indispensable materials in the field of prosthetic dentistry due to their strength and excellent esthetics. Recently, novel fully crystallized LDS for the milling process have been introduced to the market, requiring only chairside polishing before delivery. Since limited data is available about subjecting this material to glazing, this study aimed to evaluate the wear properties, fracture resistance, and optical properties of the newly introduced fully crystallized LDS after glazing. METHODS: Lithium disilicate glass-ceramics (fully crystallized (LiSiCAD) and partially crystallized types (EmaxCAD), of shade A3, were used in the present study. The fully crystallized specimens were subjected to a glazing firing cycle in a furnace (LiSiCAD-G) and compared to a polished fully crystallized counterpart (LiSiCAD-P, negative control) and a glazed partially crystallized LDS (EmaxCAD, positive control). Rectangular-shaped ceramic specimens (n = 10, 12 × 6.5 × 1.5 mm) and enamel antagonists were used to test the wear resistance in a specially designed wear machine built at the Department of Oral Technology, University of Bonn, Germany. The volumetric enamel loss of antagonists was measured by means of overlapping virtual 3D models derived from micro-CT scans for the teeth before and after the wear test. The weight loss of ceramic specimens in milligrams was measured after 100,000 and 200,000 wear cycles. A spectrophotometer was used to calculate the CIELAB color parameters of the ceramic specimens against black and white backgrounds to measure the translucency. Fracture resistance was also assessed after thermodynamic fatigue using a universal testing machine until fracture at a 1 mm/min crosshead speed. Statistical analysis was performed using one-way ANOVA and the significance level was set at α = 0.05. RESULTS: EmaxCAD and LisiCAD-G groups showed significantly higher mean ceramic weight loss after 100,000 cycles (2 ± 0.3 mg and 1.93 ± 0.2 mg, respectively) than LisiCAD-P group (0.78 ± 0.19 mg). Glazed LiSiCAD specimens demonstrated significantly higher ΔE values from shade A3 compared to polished LiSiCAD. There was no significant difference in ΔE between LiSiCAD-G and EmaxCAD. For fracture resistance, no significant difference was observed between LiSiCAD-G and LiSiCAD-P before or after aging. CONCLUSIONS: The glazed fully crystallized LDS was superior to the partially crystallized one with regard to wear resistance but showed more color changes than the polished fully crystallized one. Furthermore, polishing of fully crystallized LDS could still be considered a better option than glazing when aesthetics is a primary prerequisite.


Assuntos
Porcelana Dentária , Fraturas Ósseas , Humanos , Cerâmica , Análise de Variância
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA