Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Am Acad Orthop Surg ; 30(9): 428-436, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35171846

RESUMO

INTRODUCTION: Surgical specialties are at an increased risk for occupational hazards, including sharps-related injuries. The objective of this study was to report the frequency of sharps injuries and evaluate which characteristics influence the number of injuries and reporting behaviors. METHODS: A web-based, anonymous survey was available for 10 weeks to 46 US orthopaedic surgery residency programs (1,207 potential residents) participating in an education research collaborative. The survey was divided into the following areas: demographics, training and attitudes concerning occupational hazards, and sharps injuries and reporting. Logistic regression was used to evaluate the association between the above variables on experiencing sharps injuries with significance threshold set at P < 0.05. RESULTS: In this study, 518 surveys were included yielding a response rate of 42.9% (518/1,207). Nearly 80% of the residents recalled some form of safety training during intern orientation and 62% of the respondents felt that they received adequate occupation safety training specifically related to orthopaedic surgery. Four hundred seventeen residents (80.5%) experienced a sharps injury (mean 2.8). Nearly 20% of the respondents experienced ≥5 sharps injuries. Needle sticks (38.8%) were responsible for the greatest percentage of injuries, followed by Kirschner wires (33.6%), scalpel (22.5%), and bone (17.3%). Only 42% of the residents consistently reported all injuries. Reasons included feelings of no risk (63.1%), too much hassle (58.9%), embarrassment (14.5%), other (8.7%), forgot (5.8%), and unclear what to do (3.3%). Inadequate safety training specific to orthopaedic surgery (odds ratio, 2.32 [95% confidence interval, 1.20 to 4.46]; P = 0.012) and greater training seniority (odds ratio, 2.04 [95% confidence interval, 1.64 to 2.52]; P < 0.0001) were associated with acquiring five or more sharps injuries. DISCUSSION: Sharps injuries are a prevalent and concerning reality for orthopaedic surgical trainees. Despite this common occurrence, only 42% of the residents always reported their injuries. Inadequate training specific to orthopaedic surgery and each subsequent year of postgraduate training are associated with increased sharps injuries. STUDY TYPE: Level III, retrospective observational survey.


Assuntos
Internato e Residência , Ferimentos Penetrantes Produzidos por Agulha , Procedimentos Ortopédicos , Ortopedia , Humanos , Ferimentos Penetrantes Produzidos por Agulha/epidemiologia , Ferimentos Penetrantes Produzidos por Agulha/etiologia , Ortopedia/educação , Estudos Retrospectivos , Inquéritos e Questionários , Local de Trabalho
2.
J Surg Educ ; 77(6): 1638-1645, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32505670

RESUMO

INTRODUCTION: Orthopedic surgery residents are at risk for daily work-related hazards and exposures. Hazards related specific to this specialty includes radiation exposure, smoke inhalation (from electrocautery), and disease transmission through contact with surgical instruments or sharps during procedures. However, minimal research has been focused on other occupational hazard risks in orthopedic surgery including surgical splash events and workplace violence. This study focused on determining (1) whether or not use of protective eyewear in the workplace would be related to the availability of personal protective equipment (PPE); (2) resident education; and (3) the rate of workplace violence toward orthopedic surgery residents during their training. METHODS: An invitation to participate in a web-based, anonymous survey to 46 US allopathic orthopedic surgery residency programs (1207 potential resident respondents). The survey was conceptually divided into the following areas: (1) demographics; (2) training and attitudes concerning occupational hazards; (3) PPE provision and use; (4) sharps injuries and reporting; and (5) general safety knowledge and violence in the workplace. Those who answered yes to having a splatter event or receiving a threat at the hospital were compared to those who did not. Logistic regression was used to estimate odds ratios (ORs) and 95% confidence intervals (CIs) for the association between these outcomes and selected independent variables of interest. p-Values of <0.05 were considered statistically significant. RESULTS: From January 18 to March 31, 2016, 518 surveys were received and included for analysis for a response rate of 42.9% (518/1207). One survey was excluded from analysis due to <50% completed response items. Self-reported program types were 64.5% (334/518) public university-affiliated, 23.2% (120/518) private university affiliated, 7.1% (37/518) community, and 5.2% (27/518) military. Residents were 83.0% = male and 17.0% = female. Overall, reported eye protection usage was 95% amongst all residents and 22% of residents reported experiencing a violent threat in the workplace. The risk of experiencing a splatter event was not statistically associated with residency type, gender, or geographic region. Senior residents were at an increased likelihood of experiencing a splatter event (OR 1.22, [95% CI 1.06-1.41], p = 0.006) when compared to PGY-1 residents. The risk of a violent experience at work was not statistically associated with residency type, year of residency training, or gender. Residents in the Northeast were more likely to have a violent experience (OR 2.78 [95% CI 1.41-5.49] p = 0.003). Overall, residents felt that they had adequate training to prevent occupational hazards (mean of 3.9/5 on Likert scale) and respond to hazards (mean of 3.7/5 Likert). CONCLUSIONS: Occupational hazards are not uncommon in orthopedic surgery training with high rates of improper eyewear PPE use and poor awareness of Occupational Safety and Health Administration and AAOS guidelines. Violence in the workplace impacts over one in 4 residents and training programs and hospitals should improve education and report efforts. Continual yearly PPE training and awareness of AAOS guidelines could be intertwined with duty hour and/or case logs in order to ensure residents are exposed to this material on a regular basis.


Assuntos
Cirurgia Geral , Internato e Residência , Procedimentos Ortopédicos , Ortopedia , Violência no Trabalho , Feminino , Cirurgia Geral/educação , Humanos , Masculino , Ortopedia/educação , Inquéritos e Questionários , Local de Trabalho , Violência no Trabalho/prevenção & controle
3.
J Bone Joint Surg Am ; 100(3): e16, 2018 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-29406352

RESUMO

BACKGROUND: Excessive radiation to health-care providers has been linked to risks of cancer and cataracts, but its negative effects can be substantially reduced by lead aprons, thyroid shields, and leaded glasses. Hospitals are required to provide education and proper personal protective equipment, yet discrepancies exist between recommendations and compliance. This article presents the results of a survey of U.S. orthopaedic surgery residents concerning attitudes toward radiation exposure and personal protective equipment behavior. METHODS: An invitation to participate in a web-based, anonymous survey was distributed to 46 U.S. allopathic orthopaedic surgery residency programs (1,207 potential resident respondents). The survey was conceptually divided into the following areas: demographic characteristics, training and attitudes concerning occupational hazards, personal protective equipment provision and use, and general safety knowledge. Prevalence ratios (PRs) and 95% confidence intervals (CIs) were calculated for the association between these characteristics and compliance with thyroid shield or lead gown wear. RESULTS: In this study, 518 surveys were received, with 1 survey excluded because of insufficient response, leaving 517 surveys for analysis (42.8% response rate). Ninety-eight percent of residents believed that personal protective equipment should be provided by the hospital or residency program. However, provision of personal protective equipment was not universal, with 33.8% reporting none and 54.2% reporting provision of a gown and thyroid shield. The prevalence of leaded glasses usage was 21%. Poor lead gown compliance and thyroid shield wear were associated with difficulty finding the corresponding equipment: PR, 2.51 (95% CI, 1.75 to 3.62; p < 0.001) for poor lead gown compliance and PR, 2.14 (95% CI, 1.46 to 3.16; p < 0.0001) for poor thyroid shield wear. Not being provided with personal protective equipment was also significantly associated with low compliance with both lead gowns (PR, 1.47 [95% CI, 1.04 to 2.08]; p = 0.03) and thyroid shields (PR, 1.69 [95% CI, 1.18 to 2.41]; p = 0.004). Respondents from the Southeast, West, or Midwest had lower compliance with lead gown usage. Forgetting was the number 1 reason to not wear a lead apron (42%). CONCLUSIONS: Radiation exposure is associated with increased risk of serious health problems. Our findings identified that the availability of lead personal protective equipment leads to increased compliance among residents surveyed. In addition to yearly occupational hazard training specific to orthopaedic surgery, greater efforts by residency programs and hospitals are needed to improve access to lead personal protective equipment and compliance for orthopaedic residents.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Internato e Residência , Exposição Ocupacional/prevenção & controle , Ortopedia/educação , Médicos/psicologia , Exposição à Radiação/prevenção & controle , Proteção Radiológica , Adulto , Feminino , Humanos , Masculino , Inquéritos e Questionários , Estados Unidos
4.
Acta Biomater ; 7(1): 203-15, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20727992

RESUMO

We describe the structural and functional properties of three-dimensional (3D) nerve guides fabricated from poly-ε-caprolactone (PCL) using the air gap electrospinning process. This process makes it possible to deposit nano-to-micron diameter fibers into linear bundles that are aligned in parallel with the long axis of a cylindrical construct. By varying starting electrospinning conditions it is possible to modulate scaffold material properties and void space volume. The architecture of these constructs provides thousands of potential channels to direct axon growth. In cell culture functional assays, scaffolds composed of individual PCL fibers ranging from 400 to 1500 nm supported the penetration and growth of axons from rat dorsal root ganglion. To test the efficacy of our guide design we reconstructed 10mm lesions in the rodent sciatic nerve with scaffolds that had fibers 1 µm in average diameter and void volumes >90%. Seven weeks post implantation, microscopic examination of the regenerating tissue revealed dense, parallel arrays of myelinated and non-myelinated axons. Functional blood vessels were scattered throughout the implant. We speculate that end organ targeting might be improved in nerve injuries if axons can be directed to regenerate along specific tissue planes by a guide composed of 3D fiber arrays.


Assuntos
Ar , Regeneração Tecidual Guiada/métodos , Regeneração Nervosa/fisiologia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Células Cultivadas , Análise de Fourier , Implantes Experimentais , Teste de Materiais , Nervos Periféricos/fisiologia , Nervos Periféricos/ultraestrutura , Ratos , Soluções
5.
Biologicals ; 38(6): 619-28, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20705479

RESUMO

Experimental salmon thrombin/fibrinogen dressings have been shown to provide effective hemostasis in severe hemorrhage situations. The hypothesis for this study was that swine would still remain healthy without coagulopathy six months after exposure to salmon thrombin/fibrinogen dressings. Initial exposure was by insertion of the salmon dressing into the peritoneal cavity. Three months after the initial exposure, the same animals were subjected to two full thickness dermal wounds on the dorsal surface. One wound was bandaged with the salmon thrombin/fibrinogen bandage and the other wound was dressed with a standard bandage. The animals were monitored for an additional three months. Blood was drawn every 14 days over the six months for immunological and coagulation function analysis. All of the animals (8 pigs) remained healthy during the six month period and the dermal wounds healed without incidence. Lymph nodes and spleen showed signs of normal immune response and Western blots showed development of antibodies against salmon fibrinogen, but none of the animals made antibodies that recognized any species of thrombin. Coagulation parameters (fibrinogen concentration, thrombin time, PT and aPTT) and hematological parameters remained normal over the course of the study when compared to initial values of the subject swine.


Assuntos
Bandagens , Fibrinogênio/imunologia , Hemostasia , Trombina/imunologia , Animais , Feminino , Fibrinogênio/administração & dosagem , Salmão , Suínos , Trombina/administração & dosagem , Cicatrização
6.
Acta Biomater ; 5(1): 518-29, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18676212

RESUMO

We cross-linked scaffolds of electrospun collagen to varying degrees with glutaraldehyde using an ethanol-based solvent system and subsequently defined how the percentage of cross-linking impacts bulk and microscale material properties and fiber structure. At hydration, electrospun fibers underwent coiling; the extent of coiling was proportional to the percentage of cross-linking introduced into the samples and was largely suppressed as cross-linking approached saturation. These data suggest that electrospun collagen fibers are not deposited in a minimal energy state; fiber coiling may reflect a molecular reorganization. This result has functional/structural implications for protein-based electrospun scaffolds. Changes in fiber topology that develop during post-electrospinning processing may alter monomer organization, mask or unmask receptor binding sites, and/or change the biological properties of these nanomaterials. Hydrated scaffolds were mounted into a custom stretching device installed on a microscope stage and photographed after incremental changes in strain. Changes in fiber alignment were measured using the two-dimensional fast Fourier transform method. Fibers in all scaffolds underwent alignment in response to strain; however, the rate and extent of alignment that could be achieved varied as a function of cross-linking. We propose four distinct modes of scaffold response to strain: fiber uncoiling, fiber reorientation, fiber elongation and interfiber sliding. We conclude that bulk material properties and local microscale architecture must be simultaneously considered to optimize the performance of electrospun scaffolds.


Assuntos
Materiais Biocompatíveis/química , Engenharia Tecidual/métodos , Animais , Anisotropia , Bovinos , Colágeno/química , Reagentes de Ligações Cruzadas/química , Eletroquímica/métodos , Análise de Fourier , Teste de Materiais , Conformação Molecular , Nanoestruturas/química , Nanotecnologia , Propriedades de Superfície , Temperatura
7.
J Biomater Sci Polym Ed ; 19(5): 603-21, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18419940

RESUMO

In this study we describe how to use a two-dimensional fast Fourier transform (2D FFT) approach to measure fiber alignment in electrospun materials. This image processing function can be coupled with a variety of imaging modalities to assign an objective numerical value to scaffold anisotropy. A data image of an electrospun scaffold is composed of pixels that depict the spatial organization of the constituent fibers. The 2D FFT function converts this spatial information into a mathematically defined frequency domain that maps the rate at which pixel intensities change across the original data image. This output image also contains quantitative information concerning the orientation of objects in a data image. We discuss the theory and practice of using the frequency plot of the 2D FFT function to measure relative scaffold anisotropy and identify the principal axis of fiber orientation. We note that specific degrees of scaffold anisotropy may represent a critical design feature in the fabrication of tissues that will be subjected to well-defined uniaxial mechanical loads. This structural property may also represent a source of guidance cues that can be exploited to regulate cell phenotype.


Assuntos
Materiais Biocompatíveis/química , Análise de Fourier , Engenharia Tecidual/métodos , Anisotropia , Microscopia Eletrônica de Varredura
8.
J Biol Eng ; 1: 2, 2007 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-18271978

RESUMO

BACKGROUND: Electrospinning is a non-mechanical processing strategy that can be used to process a variety of native and synthetic polymers into highly porous materials composed of nano-scale to micron-scale diameter fibers. By nature, electrospun materials exhibit an extensive surface area and highly interconnected pore spaces. In this study we adopted a biological engineering approach to ask how the specific unique advantages of the electrospinning process might be exploited to produce a new class of research/diagnostic tools. METHODS: The electrospinning properties of nitrocellulose, charged nylon and blends of these materials are characterized. RESULTS: Nitrocellulose electrospun from a starting concentration of < 110 mg/ml acetone deposited as 4-8 mum diameter beads; at 110 mg/ml-to-140 mg/ml starting concentrations, this polymer deposited as 100-4000 nm diameter fibers. Nylon formed fibers when electrospun from 60-140 mg/ml HFIP, fibers ranged from 120 nm-6000 nm in diameter. Electrospun nitrocellulose exhibited superior protein retention and increased sensitivity in slot blot experiments with respect to the parent nitrocellulose material. Western immunoblot experiments using fibronectin as a model protein demonstrated that electrospun nylon exhibits increased protein binding and increased dynamic range in the chemiluminescence detection of antigens than sheets of the parent starting material. Composites of electrospun nitrocellulose and electrospun nylon exhibit high protein binding activity and provide increased sensitivity for the immuno-detection of antigens. CONCLUSION: The flexibility afforded by electrospinning process makes it possible to tailor blotting membranes to specific applications. Electrospinning has a variety of potential applications in the clinical diagnostic field of use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA