Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Toxicol ; 43(7): 1039-1049, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36735643

RESUMO

Maca (Lepidium meyenii Walp.) has been used in folk medicine to treat fertility disturbances, a claim that has been evidenced in some studies. However, the clinical trials validating this use have shown paradoxical findings and then maca safety is not well known. This study investigated the effects and mechanisms by which maca affects the reproductive system using an in vivo model, the nematode Caenorhabditis elegans. Tuber maca powder, obtained from local commerce, was used to prepare the aqueous extract. Worms were acutely exposed to maca extracts (40, 120, 240, and 330 µg/µl), and 48 h after treatments, physiological and biochemical assays were conducted. Maca extract caused a significant decrease in total number of eggs and in the number of eggs per worm. These effects were associated to increased lipid peroxidation, reduced triacylglycerol levels, and also impaired vit-2 (vitellogenin) expression, besides increase in the number of apoptotic germline cells. We have found quantifiable levels of alkaloids in this maca extract, which presence could be related to this toxicity. Collectively, our data suggest that maca extract exposure causes reproductive toxicity to worms that could be, at least in part, associated to both an increase in apoptosis of germline cells and also to a decrease in vitellogenin expression, needed for egg yolk production and, consequently, successful reproduction.


Assuntos
Lepidium , Extratos Vegetais , Animais , Extratos Vegetais/farmacologia , Caenorhabditis elegans , Peru , Vitelogeninas , Água
2.
J Chromatogr Sci ; 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36585772

RESUMO

A new stability-indicating liquid chromatography method was developed for the quantification of empagliflozin and two synthetic impurities. The chromatographic conditions included Spherisorb® RP-18 column (150 × 4.6 mm, 5 µm) with a PDA detector, using acetonitrile and formic acid (pH 4.0) as mobile phase in gradient elution and flow-rate of 1.2 mL·min-1. The gradient increasing from 51 to 100% acetonitrile until 11.00 min, followed by decreasing the solvent from 100% to the initial ratio from 11.01 to 15.00 min. The method was validated according to International Council of Harmonization guidelines. The LOD and LOQ values for impurities A and B were 35 and 15 ng·mL-1, respectively, (for LOD) and 115 and 35 ng.mL-1, respectively (for LOQ). The method was linear in the range of 80-140, 115-1150 and 35-350 ng·mL-1 for EMPA, impurities A and B, respectively, and the correlation coefficient were > 0.999 in all situations, indicating the method good linearity. The developed method showed a good recovery for empagliflozin and added impurities. The method has proven to be precise, demonstrated values less than 2.0% to empagliflozin and 5.0% to synthetic impurities, robust and selective with no interference from other products in the determination of analytes. The in silico toxicity prediction suggested that the impurities do not present any toxicity risk for the parameters evaluated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA