Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Infect Control ; 52(6): 701-706, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38181902

RESUMO

BACKGROUND: Wastewater surveillance for SARS-CoV-2 has been used widely in the United States for indication of community incidence during the COVID-19 pandemic, but less is known about the feasibility of its use on a building level in nursing homes to provide early warning and prevent transmission. METHODS: A pilot study was conducted at 8 Department of Veterans Affairs nursing homes across the United States to examine operational feasibility. Wastewater from the participating facilities was sampled daily during the week for 6 months (January 11, 2021-July 2, 2021) and analyzed for SARS-CoV-2 genetic material. Wastewater results were compared to new SARS-CoV-2 infections in nursing home residents and employees to determine if wastewater surveillance could provide early warning of a COVID-19-positive occupant. RESULTS: All 8 nursing homes had wastewater samples positive for SARS-CoV-2 and COVID-19-positive occupants. The sensitivity of wastewater surveillance for early warning of COVID-19-positive residents was 60% (3/5) and for COVID-19-positive employees was 46% (13/28). CONCLUSIONS: Wastewater surveillance may provide additional information for reinforcing infection control practices and lead to preventing transmission in a setting with high-risk residents. The low sensitivity for early warning in this real-world pilot highlights limitations and insights for applicability in buildings.


Assuntos
COVID-19 , Casas de Saúde , SARS-CoV-2 , Águas Residuárias , Humanos , COVID-19/prevenção & controle , COVID-19/epidemiologia , COVID-19/diagnóstico , COVID-19/transmissão , Projetos Piloto , Águas Residuárias/virologia , SARS-CoV-2/isolamento & purificação , Estados Unidos/epidemiologia
2.
SAGE Open Med ; 8: 2050312120962372, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33101679

RESUMO

OBJECTIVES: Hospitals and healthcare facilities rely largely on isolation and environmental disinfection to prevent transmission of pathogens. The use of no-touch technology is an accepted practice for environmental decontamination in medical care facilities, but little has been published about the effect of ultraviolet light generated by a portable pulsed-xenon device use on Mycobacteria. We used Mycobacterium fortuitum which is more resistant to ultraviolet radiation and less virulent than Mycobacterium tuberculosis, to determine the effectiveness of portable pulsed-xenon devices on Mycobacterium in a laboratory environment. METHODS: To determine the effectiveness of pulsed-xenon devices, we measured the bactericidal effect of pulsed-xenon devices on Mycobacterium fortuitum. RESULTS: In five separate experiments irradiating an average of 106 organisms, the mean (standard deviation) log-kill at 5 min was 3.98 (0.60), at 10 min was 4.96 (0.42), and at 15 min was 5.64 (0.52). CONCLUSIONS: Our results demonstrate that using pulsed-xenon devices is a highly effective modality to reduce microbial counts with this relatively ultraviolet germicidal irradiation-resistant mycobacterium in a time-dependent manner.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA