RESUMO
Purpose: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligence (AI)-based coronary artery calcium scoring were assessed. Methods: In a clinical registry of 10481 patients undergoing heart and lung CT, GCCT was applied in 44 patients on a dual-source CT. Coronary calcium scans (CCS) with 120 kVp, 100 kVp, and tin-filtered 100 kVp (Sn100) of controls, matched with regard to age, sex, and body-mass index, were retrieved from the registry (ntotal=176, 66.5 (59.4-74.0) years, 52 men). Automatic tube current modulation was used in all scans. In 20 patients undergoing GCCT and Sn100 CCS, Agatston scores were measured both semi-automatically by experts and by AI, and classified into six groups (0, <10, <100, <400, <1000, ≥1000). Results: Effective dose decreased significantly from 120 kVp CCS (0.50 (0.41-0.61) mSv) to 100 kVp CCS (0.34 (0.26-0.37) mSv) to Sn100 CCS (0.14 (0.11-0.17) mSv). GCCT showed higher values (0.28 (0.21-0.32) mSv) than Sn100 CCS but lower than 120 kVp and 100 kVp CCS (all p < 0.05) despite greater scan length. Agatston scores correlated strongly between GCCT and Sn100 CCS in semi-automatic and AI-based measurements (both ρ = 0.98, p < 0.001) resulting in high agreement in Agatston score classification (κ = 0.97, 95% CI 0.92-1.00; κ = 0.89, 95% CI 0.79-0.99). Regarding chest findings, further diagnostic steps were recommended in 28 patients. Conclusions: GCCT allows for reliable coronary artery disease and lung cancer screening with ultra-low radiation exposure. GCCT-derived Agatston score shows excellent agreement with standard CCS, resulting in equivalent risk stratification.
RESUMO
OBJECTIVES: Since the safety of coronary CT angiography (CTA) is of great importance, especially with regard to widening indications and increasing morbidity, the aim of this study was to assess influencing factors. METHODS: Patients undergoing coronary CTA in a third-generation dual-source CT in a radiological centre were included in a clinical registry. Up to 20 mg metoprolol was administered intravenously to attain a heart rate ≤65/min. Glyceryl trinitrate (GTN) was administered in doses of 0.8 mg and 0.4 mg. Blood pressure was measured before the administration and after the CTA. RESULTS: Out of 5500 consecutive patients (3194 men, 62.3 (54.9-70.0) years), adverse events occurred in 68 patients (1.2%) with mild anaphylactoid reactions (0.4%), vasovagal symptoms (0.3%) and extravasation (0.3%) being most frequent. Anti-allergic drugs were given in 17 patients, atropine in 3 patients and volume in 1 patient. Drug administration resulted in a significant mean arterial pressure decline (96.0 (88.3-106.0) vs 108.7 (99.7-117.3) mmHg; p<0.001). Patients who suffered systolic blood pressure drops >20 mmHg or >40 mmHg were older (66.5 (58.6-73.3) vs 60.5 (53.6-68.3) years; 70.2 (63.3-76.5) vs 62.1 (54.7-69.6) years), more often male (65.1% vs 54.4%; 68.9% vs 57.3%) and had higher Agatston score equivalents (83.0 (2.0-432.0) vs 15.0 (0.0-172.0); 163.0 (16.3-830.8) vs 25.0 (0.0-220.0); all p<0.001). GTN dose reduction lowered the fraction of patients suffering from blood pressure drops >20 mmHg or >40 mmHg from 34.5% to 27.4% and from 6.1% to 3.5% (both p<0.001), respectively. The proportion of coronary segments with impaired image quality did not differ significantly. CONCLUSIONS: Coronary CTA with intravenous beta-blocker administration is a safe procedure in an outpatient setting as adverse events are rare and mostly mild. Reduced GTN doses can further improve safety by lowering the rate of significant blood pressure drops, which occurred especially in elderly men with increased plaque burden. TRIAL REGISTRATION NUMBER: NCT03815123.
Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Idoso , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Masculino , Nitroglicerina/efeitos adversos , Pacientes Ambulatoriais , Sistema de Registros , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodosRESUMO
BACKGROUND: Machine-Learning Computed Tomography-Based Fractional Flow Reserve (CT-FFRML) is a novel tool for the assessment of hemodynamic relevance of coronary artery stenoses. We examined the diagnostic performance of CT-FFRML compared to stress perfusion cardiovascular magnetic resonance (CMR) and tested if there is an additional value of CT-FFRML over coronary computed tomography angiography (cCTA). METHODS: Our retrospective analysis included 269 vessels in 141 patients (mean age 67 ± 9 years, 78% males) who underwent clinically indicated cCTA and subsequent stress perfusion CMR within a period of 2 months. CT-FFRML values were calculated from standard cCTA. RESULTS: CT-FFRML revealed no hemodynamic significance in 79% of the patients having ≥ 50% stenosis in cCTA. Chi2 values for the statistical relationship between CT-FFRML and stress perfusion CMR was significant (p < 0.0001). CT-FFRML and cCTA (≥ 70% stenosis) provided a per patient sensitivity of 88% (95%CI 64-99%) and 59% (95%CI 33-82%); specificity of 90% (95%CI 84-95%) and 85% (95%CI 78-91%); positive predictive value of 56% (95%CI 42-69%) and 36% (95%CI 24-50%); negative predictive value of 98% (95%CI 94-100%) and 94% (95%CI 90-96%); accuracy of 90% (95%CI 84-94%) and 82% (95%CI 75-88%) when compared to stress perfusion CMR. The accuracy of cCTA (≥ 50% stenosis) was 19% (95%CI 13-27%). The AUCs were 0.89 for CT-FFRML and 0.74 for cCTA (≥ 70% stenosis) and therefore significantly different (p < 0.05). CONCLUSION: CT-FFRML compared to stress perfusion CMR as the reference standard shows high diagnostic power in the identification of patients with hemodynamically significant coronary artery stenosis. This could support the role of cCTA as gatekeeper for further downstream testing and may reduce the number of patients undergoing unnecessary invasive workup.
Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Idoso , Vasos Coronários/fisiopatologia , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos RetrospectivosRESUMO
Background: Coronary artery disease (CAD) shows a chronic but heterogeneous clinical course. Coronary CT angiography (CTA) allows for the visualization of the entire coronary tree and the detection of early stages of CAD. The aim of this study was to assess short-time changes in non-calcified and mixed plaques and their clinical impact using coronary CTA in a real-world setting. Methods: Between 11/2014 and 07/2019, 6,701 patients had a coronary CTA with a third-generation dual-source CT, of whom 77 patients (57 males, 63.8 ± 10.8 years) with a chronic CAD received clinically indicated follow-up CTA. Non-calcified and mixed plaques were analyzed in 1,211 coronary segments. Patients were divided into groups: stable, progressive, or regressive plaques. Results: Within the follow-up period of 22.3 ± 10.4 months, 44 patients (58%) showed stable plaques, 27 (36%) showed progression, 5 (7%) showed regression. One patient was excluded due to an undetermined CAD course showing both, progressive and regressive plaques. Age did not differ significantly between groups. Patients with plaque regression were predominantly female (80 vs. 20%), whereas patients showing progression were mainly male (85 vs. 15%; p < 0.01 for both). Regression was only observed in patients with mild CAD or one-vessel disease. The follow-up CTA led to changes in patient management in the majority of subjects (n = 50; 66%). Conclusions: Changes in coronary artery plaques can be observed within a short period resulting in an adjustment of the clinical management in the majority of CAD patients. Follow-up coronary CTA renders the non-invasive assessment of plaque development possible and allows for an individualized diagnostics and therapy optimization.
RESUMO
BACKGROUND: The usage of coronary CT angiography (CTA) is appropriate in patients with acute or chronic chest pain; however the diagnostic accuracy may be challenged with increased Agatston score (AS), increased heart rate, arrhythmia and severe obesity. Thus, we aim to determine the potential of the recently introduced third-generation dual-source CT (DSCT) for CTA in a 'real-life' clinical setting. METHODS: Two hundred and sixty-eight consecutive patients (age: 67 ± 10 years; BMI: 27 ± 5 kg/m²; 61% male) undergoing clinically indicated CTA with DSCT were included in the retrospective single-center analysis. A contrast-enhanced volume dataset was acquired in sequential (SSM) (n = 151) or helical scan mode (HSM) (n = 117). Coronary segments were classified in diagnostic or non-diagnostic image quality. A subset underwent invasive angiography to determine the diagnostic accuracy of CTA. RESULTS: SSM (96.8 ± 6%) and HSM (97.5 ± 8%) provided no significant differences in the overall diagnostic image quality. However, AS had significant influence on diagnostic image quality exclusively in SSM (B = 0.003; p = 0.0001), but not in HSM. Diagnostic image quality significantly decreased in SSM in patients with AS ≥2,000 (p = 0.03). SSM (sensitivity: 93.9%; specificity: 96.7%; PPV: 88.6%; NPV: 98.3%) and HSM (sensitivity: 97.4%; specificity: 94.3%; PPV: 86.0%; NPV: 99.0%) provided comparable diagnostic accuracy (p = n.s.). SSM yielded significantly lower radiation doses as compared to HSM (2.1 ± 2.0 vs. 5.1 ± 3.3 mSv; p = 0.0001) in age and BMI-matched cohorts. CONCLUSION: SSM in third-generation DSCT enables significant dose savings and provides robust diagnostic image quality in patients with AS ≤2000 independent of heart rate, heart rhythm or obesity.