Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Acta Physiol (Oxf) ; 240(3): e14111, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38314948

RESUMO

AIM: This study aimed to investigate the effects of caffeine on pathways associated with mitochondrial quality control and mitochondrial capacity during skeletal muscle regeneration, focusing on the role of Parkin, a key protein involved in mitophagy. METHODS: We used in vitro C2C12 myoblast during differentiation with and without caffeine in the medium, and we evaluated several markers of mitochondrial quality control pathways and myotube growth. In vivo experiments, we used C57BL/6J (WT) and Parkintm 1Shn lineage (Parkin-/- ) mice and injured tibial anterior muscle. The mice regenerated TA muscle for 3, 10, and 21 days with or without caffeine ingestion. TA muscle was used to analyze the protein content of several markers of mitochondrial quality pathways, muscle satellite cell differentiation, and protein synthesis. Furthermore, it analyzed mtDNA, mitochondrial respiration, and myofiber growth. RESULTS: C2C12 differentiation experiments showed that caffeine decreased Parkin content, potentially leading to increased DRP1 and PGC-1α content and altered mitochondrial population, thereby enhancing growth capacity. Using Parkin-/- mice, we found that caffeine intake during the regenerative process induces an increase in AMPKα phosphorylation and PGC-1α and TFAM content, changes that were partly Parkin-dependent. In addition, the absence of Parkin potentiates the ergogenic effect of caffeine by increasing mitochondrial capacity and myotube growth. Those effects are related to increased ATF4 content and activation of protein synthesis pathways, such as increased 4E-BP1 phosphorylation. CONCLUSION: These findings demonstrate that caffeine ingestion changes mitochondrial quality control during skeletal muscle regeneration, and Parkin is a central player in those mechanisms.


Assuntos
Cafeína , Músculo Esquelético , Camundongos , Animais , Cafeína/farmacologia , Músculo Esquelético/metabolismo , Camundongos Endogâmicos C57BL , Ubiquitina-Proteína Ligases/genética , Ubiquitina-Proteína Ligases/metabolismo , Regeneração
2.
J Dent Res ; 103(4): 427-433, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38284313

RESUMO

The phosphate ester monomer 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) is capable of bonding to hydroxyapatite and, for this reason, is a key component of several self-etch adhesives. In this study, dicalcium phosphate dihydrate particles (DCPD; CaHPO4.2H2O) were functionalized with 10-MDP and used to formulate an experimental composite with 50 vol% inorganic content (3:1 DCPD:silanated barium glass ratio) dispersed in a BisGMA/TEGDMA matrix. The tested hypothesis was that DCPD functionalization would improve the composite's mechanical performance without compromising Ca2+ release. Composites containing nonfunctionalized DCPD or only reinforcing glass (in both cases, with or without 10-MDP mixed in the resin phase) were used as controls. Materials were tested for degree of conversion (DC; by Fourier transform infrared spectroscopy), water sorption (WS) and solubility (SL; according to ISO 4049), biaxial flexural strength (BFS)/modulus (FM) after 24 h and 5 mo in water, and 28-d Ca2+ release in water (by plasma-coupled optical emission spectroscopy). Data were analyzed using analysis of variance/Tukey test (alpha: 5%). DCPD functionalization did not interfere with DC. The composite containing functionalized DCPD showed significantly lower WS and SL in comparison with the material formulated with nonfunctionalized particles. The presence of 10-MDP (as a functionalizing agent or dispersed in the resin phase) reduced the composite's initial BFS and FM. After 5 mo in water, the composite with functionalized DCPD and both glass-only composites were able to maintain their mechanical properties at levels statistically similar to what was observed after 24 h. Ca2+ release was significantly reduced in both formulations containing 10-MDP. In conclusion, DCPD functionalization with 10-MDP increased the composite's resistance to hydrolytic degradation, improving its mechanical stability after prolonged water storage. However, the impaired water transit at the particle-matrix interface led to a reduction in Ca2+ release.


Assuntos
Resinas Compostas , Metacrilatos , Resinas Compostas/química , Teste de Materiais , Metacrilatos/química , Fosfatos de Cálcio/química , Água , Cálcio
3.
Oper Dent ; 45(6): E308-E316, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32516396

RESUMO

CLINICAL RELEVANCE: Bulk-fill materials show a similar or better performance than control flowable materials regarding interfacial integrity. However, some self-adhesive composites need improvements to achieve competitive performance. SUMMARY: Objective: This laboratory study compared the polymerization stress and gap formation of self-adhesive, bulk-fill and control flowable composites. The degree of conversion (DC) and post-gel shrinkage were also assessed.Methods: Two self-adhesive (Vertise Flow and Fusio Liquid Dentin), two bulk-fill (Tetric N-Flow Bulk-Fill and Filtek Bulk-Fill Flowable Restorative), and two control flowable (Z350 XT Flowable Restorative and Tetric N-Flow) composites were evaluated. Polymerization stress (PS) was determined in a universal testing machine (n=5). Gap formation was evaluated by scanning electron microscopy in class I restorations (n=6). DC was measured by Fourier transform infrared spectroscopy (n=3). Post-gel volumetric shrinkage (VS) was measured using the strain gauge method (n=5). Data were submitted to one-way analysis of variance or a Kruskal-Wallis test (α=0.05).Results: Vertise Flow and Fusio Liquid Dentin presented the highest interfacial gap (27%±5% and 21%±6%, respectively), which was associated with their highest PS (4.1±0.8 MPa and 3.5±0.6 MPa, respectively) and DC (63%±2% and 60%±2%, respectively) in spite of the lowest VS (1.0%±0.2% and 1.0%±0.3%, respectively). Tetric N-Flow Bulk-Fill and Filtek Bulk-Fill Flowable Restorative presented similar PS (2.9± 0.3 MPa and 2.4±0.2 MPa, respectively) to both control materials. However, the Tetric N-Flow Bulk-Fill showed the lowest gap (7%±2%) and the highest DC (64.3%±0.4%), and the Filtek Bulk-fill presented a marginal gap (17.8%±3.4%) and a DC (54.5%±2.7%) similar to the control materials. The VS values of both bulk-fill materials were similar to those of Tetric N-Flow and lower than that of Z350 XT Flowable Restorative.Conclusions: Bulk-fill composites showed either similar or significantly lower interfacial gaps and PS than the control flowable composites. The self-adhesive composites showed a significantly higher gap percentage and PS than the control and bulk-fill materials.


Assuntos
Materiais Dentários , Cimentos de Resina , Resinas Compostas , Cimentos Dentários , Análise do Estresse Dentário , Teste de Materiais , Polimerização
4.
Oper Dent ; 45(3): E114-E123, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32053454

RESUMO

OBJECTIVE: The objective of this study was to evaluate the effect of erosion or erosion-abrasion on bioactive materials and adjacent enamel/dentin areas. METHODS AND MATERIALS: Enamel and dentin blocks (4×4×2 mm) were embedded side by side in acrylic resin, and a standardized cavity (1.2×4×1.5 mm) was prepared between them. Preparations were restored with the following materials: composite resin (Filtek Z350, control); experimental composite containing di-calcium phosphate dihydrate particles (DCPD); Giomer (Beautifil II), high viscosity glass ionomer cement (GIC, Fuji IX); and a resin-modified GIC (Fuji II LC). The specimens were submitted to two cycling models (n=10): erosion or erosion-abrasion. The challenges consisted of five-minute immersion in 0.3% citric acid solution, followed by 60-minute exposure to artificial saliva. Toothbrushing was carried out twice daily, 30 minutes after the first and last exposures to acid. Dental and material surface loss (SL, in µm) were determined by optical profilometry. Data were analyzed with Kruskal-Wallis and Dunn tests (α=0.05). RESULTS: Under erosion, for enamel, only the GIC groups presented lower SL values than Z350 (p<0.001 for Fuji IX and p=0.018 for Fuji II LC). For dentin, none of the materials showed significantly lower SL values than Z350 (p>0.05). For material, the GICs had significantly higher SL values than those of Z350 (p<0.001 for Fuji IX and p=0.002 for Fuji II LC). Under erosion-abrasion, the enamel SL value was significantly lower around Fuji II LC compared with the other materials (p<0.05). No significant differences were observed among groups for dentin SL (p=0.063). The GICs and Giomer showed higher SL values than Z350 (p<0.001 for the GICs and p=0.041 for Giomer). CONCLUSION: Both GIC-based materials were susceptible to erosive wear; however, they promoted the lowest erosive loss of adjacent enamel. Against erosion-abrasion, only Fuji II LC was able to reduce enamel loss. For dentin, none of the materials exhibited a significant protective effect.


Assuntos
Esmalte Dentário , Cimentos de Ionômeros de Vidro , Materiais Dentários , Dentina , Saliva Artificial , Escovação Dentária
5.
Oper Dent ; 45(3): E141-E155, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32053458

RESUMO

OBJECTIVES: This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. METHODS AND MATERIALS: Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (α=0.05). RESULTS: The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric EvoCeram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. CONCLUSIONS: Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Materiais Dentários , Dureza , Humanos , Teste de Materiais , Dente Molar , Polimerização , Propriedades de Superfície
6.
J Helminthol ; 94: e97, 2019 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-31679527

RESUMO

Several factors influence the dynamics and structure of parasite communities. Our goal was to investigate how the community composition, prevalence and abundance of parasites change across seven populations of the exotic lizard Hemidactylus mabouia in Northeast Brazil, and to describe ontogenetic and sex variations. We found differences in the composition of component communities and patterns of infection according to the host body size across the lizard populations. We did not find any variation between the sexes regarding epidemiological patterns, which can probably be explained by the similar diet and habitat use of male and female H. mabouia. An unusually high abundance and prevalence of trematodes infecting this host lizard was apparent when we compared other native lizard hosts, and we suggest that local environmental conditions might be advantageous to the development and life cycle of these parasites due to the abundance of all the intermediate and definitive hosts.


Assuntos
Lagartos/parasitologia , Parasitos/isolamento & purificação , Doenças Parasitárias em Animais/parasitologia , Animais , Tamanho Corporal , Brasil/epidemiologia , Ecossistema , Feminino , Lagartos/classificação , Lagartos/crescimento & desenvolvimento , Masculino , Parasitos/classificação , Parasitos/genética , Parasitos/fisiologia , Doenças Parasitárias em Animais/epidemiologia
8.
Eur J Prosthodont Restor Dent ; 26(3): 122-128, 2018 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-30063306

RESUMO

This study verified if experimental composites containing calcium phosphate nanoparticles exert a protective effect against enamel demineralization. Three experimental resin-based composites containing 60 vol% of fillers were manipulated. Filler phase was constituted by silanized barium glass and 0%, 10% or 20% (by volume) of dicalcium phosphate dihydrate (DPCD) nanoparticles functionalized with the monomer triethylene glycol dimethacrylate (TEGDMA). Cavities (10 x 2 x 2 mm) were prepared in bovine enamel and restored using one of the experimental materials (n=10). Specimens were exposed to pH cycling (demineralizing solution: pH 5.0/4h, remineralizing solution: pH 7.0/20h, 14 days). Enamel Knoop microhardness (100g/10s) was measured on the surface (SH) and after transversal sectioning up to 90 µm depth (cross-sectional microhardness, CSH). Microhardness values and the percent of microhardness loss were analyzed ANOVA/Tukey test and Student's paired t-test (alpha: 5%). The materials did not differ in respect to SH. Enamel adjacent to DCPD-containing composite restorations showed smaller reductions in CSH (-1.2% to -3.5%) than the enamel from control group (-12.5%), while CSH of enamel restored with resin-modified glass ionomer was similar to the other groups (-4.5%). DCPD-containing composites reduced enamel demineralization in comparison to a conventional composite.


Assuntos
Fosfatos de Cálcio/química , Resinas Compostas/química , Esmalte Dentário/efeitos dos fármacos , Materiais Dentários/química , Animais , Bovinos , Cárie Dentária/terapia , Esmalte Dentário/patologia , Dureza , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Teste de Materiais , Nanopartículas , Propriedades de Superfície
9.
Vet Parasitol ; 227: 20-5, 2016 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-27523932

RESUMO

The objective of this paper was to investigate prevalence and parasite load of the trematode Platynosomum fastosum infection and the risk of developing cholangitis/cholangiohepatitis among infected domestic cats in a city of northeastern Brazil, and to characterize the influence of fluke burden in the formation of lesions in liver and gallbladder. A total of 141 cats was necropsied and examined for the presence of P. fastosum. The observed prevalence was 42.6% (60/141, 95% CI=34.2-50.9). Parasite load varied from 1 to 219 flukes per animal. Adult cats were more frequently infected than kittens (p<0.01). Risk of cholangitis was about three times higher in infected animals (RR=3.23, 95% CI=2.01-5.07, p<0.01). Centrolobular congestion, portal cholangitis and cholestasis was significantly more common in infected as compared to non-infected cats (p<0.01). Similarly, fibrosis, cholangitis and mucous gland hyperplasia were significantly more prevalent in the bile duct of infected animals (p<0.01). Mild fibrosis and cholecystitis were observed principally in infected cats. Hyperplastic precursor lesions of cholangiocarcinoma were observed, but no solid tumor was diagnosed. These results reveal high prevalence of P. fastosum in free roaming cats in northeastern Brazil, with increased risk of liver disease.


Assuntos
Doenças do Gato/parasitologia , Trematódeos/classificação , Infecções por Trematódeos/veterinária , Animais , Brasil/epidemiologia , Doenças do Gato/epidemiologia , Gatos , Feminino , Doenças da Vesícula Biliar/epidemiologia , Doenças da Vesícula Biliar/parasitologia , Doenças da Vesícula Biliar/veterinária , Hepatopatias Parasitárias/epidemiologia , Hepatopatias Parasitárias/parasitologia , Hepatopatias Parasitárias/veterinária , Masculino , Prevalência , Infecções por Trematódeos/epidemiologia , Infecções por Trematódeos/parasitologia
10.
Int Endod J ; 48(8): 768-73, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25156123

RESUMO

AIM: To use computerized microtomography (micro-CT) to evaluate the efficacy of passive ultrasonic irrigation (PUI), with or without an additional file (F5), in removing calcium hydroxide medication. METHODOLOGY: The root canals of single-rooted human teeth were prepared with a ProTaper(®) F4 file (Dentsply Maillefer) and filled with calcium hydroxide/propylene glycol 400 paste. After 30 days of storage under 100% humidity, the teeth were divided into four groups (n = 8) according to the removal technique: passive ultrasonic irrigation (PUI) only, additional file only (file F5), PUI + additional file and master apical file only (F4, control). The specimens were scanned (SkyScan 1174, resolution: 14.36 µm) after chemomechanical preparation, 30 days after the application of Ca(OH)2 paste and following its removal. The percentage of medicament remaining was calculated in terms of total canal volume and medicament volume after storage, based on microtomographic images. Data were analysed using three-way anova/Tukey's test or Kruskal-Wallis/Student-Newman-Keuls test (alpha: 5%). RESULTS: The use of PUI resulted in lower Ca(OH)2 residue volumes (3.7%) compared to when PUI was not used (6.4%; P < 0.001). The use of the additional file did not significantly influence the percentage of remaining Ca(OH)2 . The percentage of Ca(OH)2 residue was greater in the apical region (6.4%) than in the cervical region (3.8%; P < 0.01). CONCLUSIONS: The use of PUI resulted in more effective Ca(OH)2 paste removal relative to the control regardless of the use of the additional file. The apical region had the highest residue volumes in all techniques.


Assuntos
Hidróxido de Cálcio/química , Materiais Restauradores do Canal Radicular/química , Irrigação Terapêutica/métodos , Ultrassom , Humanos , Técnicas In Vitro , Propilenoglicol/química , Fatores de Tempo , Microtomografia por Raio-X
11.
Int Endod J ; 48(1): 89-94, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24646329

RESUMO

AIM: To compare the ion release and mechanical properties of a calcium hydroxide (Dycal) and two calcium silicate (MTA Angelus and Biodentine) cements. METHODOLOGY: Calcium and hydroxyl ion release in water from 24-h set cements were calculated from titration with HCl (n = 3). Calcium release after 7, 14, 21 and 28 days at pH 5.5 and 7.0 was measured using ICP-OES (n = 6). Flexural strength (FS) and modulus (E) were tested after 48-h storage, and compressive strength (CS) was tested after 48 h and 7 days (n = 10). Ion release and mechanical data were subjected to anova/Tukey and Kruskal-Wallis/Mann-Whitney tests, respectively (α = 0.05). RESULTS: Titration curves revealed that Dycal released significantly fewer ions in solution than calcium silicates (P < 0.001). Calcium release remained constant at pH 7.0, whilst at pH 5.5, it dropped significantly by 24% after 21 days (P < 0.05). At pH 5.5, MTA Angelus released significantly more calcium than Dycal (P < 0.01), whilst Biodentine had superior ion release than Dycal at pH 7.0 (P < 0.01). Biodentine had superior flexural strength, flexural modulus and compressive strength than the other cements, whilst MTA Angelus had higher modulus than Dycal (P < 0.001). CONCLUSIONS: Immediate calcium and hydroxyl ion release in solution was significantly lower for Dycal. In general, all materials released constant calcium levels over 28 days, but release from Dycal was significantly lower than Biodentine and MTA Angelus depending on pH conditions. Biodentine had substantially higher strength and modulus than MTA Angelus and Dycal, both of which demonstrated low stress-bearing capabilities.


Assuntos
Compostos de Alumínio/química , Compostos de Cálcio/química , Hidróxido de Cálcio/química , Capeamento da Polpa Dentária/métodos , Íons/química , Minerais/química , Óxidos/química , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Silicatos/química , Bismuto , Força Compressiva , Análise do Estresse Dentário , Combinação de Medicamentos , Módulo de Elasticidade , Concentração de Íons de Hidrogênio , Espectrofotometria Atômica
12.
Dent Mater ; 30(11): 1274-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25249004

RESUMO

OBJECTIVES: To evaluate conversion, bulk mechanical properties and camphorquinone (CQ) consumption in methacrylate resins, comprising a range of overall initiator concentrations and CQ/amine ratios. METHODS: BisGMA (Bisphenol-A glycidyl dimethacrylate), TEGDMA (triethyleneglycol dimethacrylate) and UDMA (urethane dimethacrylate) were mixed at a 1:1:1 molar ratio. CQ was used as the visible light photosensitizer, in combination with EDMAB (Ethyl p-dimethylamino benzoate), at 3:1, 2:1, 1:1, 1:2 and 1:3 weight ratios, at 0.5, 1.0, 1.5, 2.0 and 3.0 wt% overall initiator concentration. Butylhydroxytoluene was added at 0.05 wt% as an inhibitor. Unfilled resins were photoactivated with a dental light source (VIP Jr, Bisco) for 60 s at 600 mW/cm(2). Flexural strength/modulus were assessed in 2×1×10 mm bars, tested in three-point bending. Degree of conversion was assessed at the bottom of the same specimens using FT-RAMAN. CQ consumption was measured using a UV-vis spectrometer. Data were analyzed with two-way ANOVA/Tukey test (α=5%). RESULTS: Lower conversion and inferior mechanical properties were observed with lower overall initiator concentrations and higher amine/CQ ratios. The lowest overall initiator concentration (0.5%) presented the statistically lowest conversion/properties results, except for the 1:3 amine/CQ ratio. For overall concentrations equal or greater to 1.5%, the amine/CQ ratio did not influence conversion or mechanical properties. CQ consumption was less efficient for the highest overall initiator concentrations and lower amine/CQ ratios. CLINICAL RELEVANCE: Above 1.5 wt% overall initiator concentration, the conversion and general mechanical properties were independent of the initiator concentration. Therefore, there seems to be no benefit to increasing the initiator concentration above that level. At higher camphorquinone concentrations, light transmission and photosensitizer consumption becomes impaired, which could lead to decreased depth of cure and yellowing of the restoration.


Assuntos
Aminas/análise , Cânfora/análogos & derivados , Metacrilatos/química , Cânfora/química , Teste de Materiais , Espectrofotometria Ultravioleta
13.
J Fish Biol ; 85(2): 246-63, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24919949

RESUMO

The diets of six shark species, Sphyrna lewini, Sphyrna zygaena, Carcharhinus obscurus, Carcharhinus limbatus, Rhizoprionodon lalandii and Galeocerdo cuvier, were investigated in a subtropical coastal ecosystem of southern Brazil. Stomach content data were obtained to assess foraging niche segregation and ontogenetic shifts in the diets of these sharks. Five of the shark species off the Paraná coast were ichthyophagous, with the exception of S. zygaena, which was teutophagous. With the exception of G. cuvier, which had a generalist diet, the other five species displayed specialization in their feeding. Ontogenetic shifts were observed in C. obscurus and S. lewini with large individuals consuming elasmobranchs. Owing to the diet overlap between C. obscurus and S. lewini, C. obscurus and C. limbatus and R. lalandii and C. limbatus, future studies on the spatial and temporal distributions of these species are needed to understand the extent of competitive interactions.


Assuntos
Dieta , Cadeia Alimentar , Tubarões , Animais , Brasil , Ecossistema , Comportamento Predatório , Tubarões/classificação , Especificidade da Espécie
14.
Oper Dent ; 39(3): 264-72, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23875819

RESUMO

OBJECTIVE: The objective of this study was to evaluate the surface roughness (SR), water sorption (WS), and solubility (SO) of four composite resins after finishing/polishing and after one year of water storage. MATERIALS AND METHODS: Two low-shrinkage composites (Filtek Silorane [3M ESPE] and Aelite LS [Bisco Inc]) and two composites of conventional formulations (Heliomolar and Tetric N-Ceram [Ivoclar Vivadent]) were tested. Their respective finishing and polishing systems (Sof-Lex Discs, 3M ESPE; Finishing Discs Kit, Bisco Inc; and Astropol F, P, HP, Ivoclar Vivadent) were used according to the manufacturers' instructions. Ten disc-shaped specimens of each composite resin were made for each evaluation. Polished surfaces were analyzed using a profilometer after 24 hours and one year. For the WS and SO, the discs were stored in desiccators until constant mass was achieved. Specimens were then stored in water for seven days or one year, at which time the mass of each specimen was measured. The specimens were dried again and dried specimen mass determined. The WS and SO were calculated from these measurements. Data were analyzed by two-way analysis of variance and Tukey post hoc test (α=0.05). RESULTS: Filtek Silorane showed the lowest SR, WS, and SO means. Water storage for one year increased the WS means for all composite resins tested. CONCLUSIONS: The silorane-based composite resin results were better than those obtained for methacrylate-based resins. One-year water storage did not change the SR and SO properties in any of the composite resins.


Assuntos
Resinas Acrílicas/uso terapêutico , Resinas Compostas/uso terapêutico , Poliuretanos/uso terapêutico , Resinas de Silorano/uso terapêutico , Polimento Dentário , Restauração Dentária Permanente/métodos , Humanos , Solubilidade , Propriedades de Superfície , Água
15.
J Dent Res ; 90(5): 596-601, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21282725

RESUMO

Progress in polymer science has led to continuous reduction of polymerization shrinkage, exemplified by a new generation of "low-shrink composites". The common inference that shrinkage stress effects will be reduced in teeth restored with such restoratives with lower shrinkage was tested in extracted human premolars. Mesio-occluso-distal slot-shaped cavities were cut and restored with a conventional (SupremePlus) or low-shrink (RefleXions, Premise, Kalore, and LS) composite (N = 5). We digitized the coronal surfaces before and 10 min after restoration to determine cuspal deflection from the buccal and lingual volume change/area. We also determined the main properties involved (total shrinkage, post-gel shrinkage, degree of conversion, and elastic modulus), as well as microleakage, to verify adequate bonding. It was shown that, due to shrinkage stresses, buccal and lingual surfaces pulled inward after restoration (9-14 microns). Only Kalore and LS resulted in significantly lower tooth deformation (ANOVA/Student-Newman-Keuls post hoc, p = 0.05). The other two low-shrink composites, despite having the lowest and highest total shrinkage values, did not cause significant differences in cuspal deflection. Deflection seemed most related to the combination of post-gel shrinkage and elastic modulus. Therefore, even for significantly lower total shrinkage values, shrinkage stress is not necessarily reduced.


Assuntos
Resinas Compostas/química , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Análise de Variância , Infiltração Dentária , Módulo de Elasticidade , Dureza , Humanos , Teste de Materiais , Polimerização , Siloxanas , Estatísticas não Paramétricas , Estresse Mecânico , Coroa do Dente
16.
J Dent Res ; 90(3): 365-70, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21098474

RESUMO

The literature shows contradictory results regarding the role of composite shrinkage and elastic modulus as determinants of polymerization stress. The present study aimed at a better understanding of the test mechanics that could explain such divergences among studies. The hypothesis was that the effects of composite shrinkage and elastic modulus on stress depend upon the compliance of the testing system. A commonly used test apparatus was simulated by finite element analysis, with different compliance levels defined by the bonding substrate (steel, glass, composite, or acrylic). Composites with moduli between 1 and 12 GPa and shrinkage values between 0.5% and 6% were modeled. Shrinkage was simulated by thermal analogy. The hypothesis was confirmed. When shrinkage and modulus increased simultaneously, stress increased regardless of the substrate. However, if shrinkage and modulus were inversely related, their magnitudes and interaction with rod material determined the stress response.


Assuntos
Resinas Compostas/química , Análise do Estresse Dentário/métodos , Teste de Materiais/métodos , Complacência (Medida de Distensibilidade) , Análise do Estresse Dentário/instrumentação , Módulo de Elasticidade , Análise de Elementos Finitos , Teste de Materiais/instrumentação , Estresse Mecânico , Temperatura de Transição
17.
J Dent Res ; 89(12): 1499-504, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20940353

RESUMO

The long-term effectiveness of chlorhexidine as a matrix metalloproteinase (MMP) inhibitor may be compromised when water is incompletely removed during dentin bonding. This study challenged this anti-bond degradation strategy by testing the null hypothesis that wet-bonding with water or ethanol has no effect on the effectiveness of chlorhexidine in preventing hybrid layer degradation over an 18-month period. Acid-etched dentin was bonded under pulpal pressure simulation with Scotchbond MP and Single Bond 2, with water wet-bonding or with a hydrophobic adhesive with ethanol wet-bonding, with or without pre-treatment with chlorhexidine diacetate (CHD). Resin-dentin beams were prepared for bond strength and TEM evaluation after 24 hrs and after aging in artificial saliva for 9 and 18 mos. Bonds made to ethanol-saturated dentin did not change over time with preservation of hybrid layer integrity. Bonds made to CHD pre-treated acid-etched dentin with commercial adhesives with water wet-bonding were preserved after 9 mos but not after 18 mos, with severe hybrid layer degradation. The results led to rejection of the null hypothesis and highlight the concept of biomimetic water replacement from the collagen intrafibrillar compartments as the ultimate goal in extending the longevity of resin-dentin bonds.


Assuntos
Colagem Dentária/métodos , Adesivos Dentinários/química , Etanol/química , Solventes/química , Condicionamento Ácido do Dente , Bis-Fenol A-Glicidil Metacrilato/química , Clorexidina/química , Clorexidina/farmacologia , Colágeno/ultraestrutura , Resinas Compostas/química , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Dentina/ultraestrutura , Humanos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Inibidores de Metaloproteinases de Matriz , Microscopia Eletrônica de Transmissão , Cimentos de Resina/química , Saliva Artificial/química , Estresse Mecânico , Fatores de Tempo , Água/química
18.
Dent Mater ; 26(7): 704-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20378161

RESUMO

OBJECTIVES: The role of inorganic content on physical properties of resin composites is well known. However, its influence on polymerization stress development has not been established. The aim of this investigation was to evaluate the influence of inorganic fraction on polymerization stress and its determinants, namely, volumetric shrinkage, elastic modulus and degree of conversion. METHODS: Eight experimental composites containing 1:1 BisGMA (bisphenylglycidyl dimethacrylate):TEGDMA (triethylene glycol dimethacrylate) (in mol) and barium glass at increasing concentrations from 25 to 60 vol.% (5% increments) were tested. Stress was determined in a universal test machine using acrylic as bonding substrate. Nominal polymerization stress was obtained diving the maximum load by the cross-surface area. Shrinkage was measured using a water picnometer. Elastic modulus was obtained by three-point flexural test. Degree of conversion was determined by FT-Raman spectroscopy. RESULTS: Polymerization stress and shrinkage showed inverse relationships with filler content (R(2)=0.965 and R(2)=0.966, respectively). Elastic modulus presented a direct correlation with inorganic content (R(2)=0.984). Degree of conversion did not vary significantly. Polymerization stress showed a strong direct correlation with shrinkage (R(2)=0.982) and inverse with elastic modulus (R(2)=0.966). SIGNIFICANCE: High inorganic contents were associated with low polymerization stress values, which can be explained by the reduced volumetric shrinkage presented by heavily filled composites.


Assuntos
Resinas Compostas/química , Adaptação Marginal Dentária , Análise de Variância , Compostos de Bário , Bis-Fenol A-Glicidil Metacrilato , Resinas Compostas/efeitos da radiação , Análise do Estresse Dentário , Módulo de Elasticidade , Dureza , Compostos Inorgânicos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Tamanho da Partícula , Transição de Fase , Maleabilidade , Polietilenoglicóis , Ácidos Polimetacrílicos , Análise de Regressão , Dióxido de Silício , Espectroscopia de Infravermelho com Transformada de Fourier
19.
Res Vet Sci ; 88(1): 101-3, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19505703

RESUMO

In this study, we evaluated the anthelmintic activity of the liquid extracted from the bark of the green coconut (LBGC), as well as butanol extract obtained from LBGC, on mouse intestinal nematodes. Thirty-six naturally infected mice were distributed into six groups receiving the following treatments: Group I: 1000 mg/kg of LBGC; Group II: 2000 mg/kg of LBGC; Group III: 500 mg/kg of butanol extract; Group IV: 1000 mg/kg of butanol extract; Group V: 0.56 mg/kg febendazole; and Group VI: 3% dimethylsulfoxide. The chemical composition of the LBGC and its butanol extract was determined by phytochemical tests. A dose of 1000 mg/kg of butanol extract had 90.70% efficacy in reducing the mouse worm burden (p<0.05). Phytochemical tests revealed the presence of triterpens, saponnins and condensed tannins in the LBGC and butanol extracts. These results suggest that Cocos nucifera extracts may be useful in the control of intestinal nematodes.


Assuntos
Anti-Helmínticos/farmacologia , Cocos , Nematoides/efeitos dos fármacos , Infecções por Nematoides/tratamento farmacológico , Casca de Planta , Extratos Vegetais/farmacologia , Animais , Relação Dose-Resposta a Droga , Intestinos/parasitologia , Camundongos/parasitologia , Fitoterapia/veterinária , Doenças dos Roedores/dietoterapia , Doenças dos Roedores/parasitologia
20.
Int Endod J ; 42(10): 867-73, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19751288

RESUMO

AIM: To compare two resin-based root canal sealers (AH Plus and dual cure Epiphany) in terms of flow, polymerization stress and bond strength to dentine. METHODOLOGY: Flow was evaluated by measuring the diameter of uncured discs of sealer (0.5 mL) after 7 min compression (20N) between two glass plates (n = 5). Polymerization stress was monitored for 60 min in 1-mm thick discs bonded to two glass rods (Ø = 5 mm) attached to a universal testing machine (n = 3). Bond strength was analyzed through micropush-out test (n = 10) and failure mode was examined with scanning electron microscope (100x and 2500x). Data were statistically analyzed using the Student's t-test (alpha = 0.05). RESULTS: Polymerization stress was 0.32 +/- 0.07 MPa for Epiphany self-cure, 0.65 +/- 0.08 MPa for Epiphany light-cure and zero for AH Plus (P < 0.05). Flow data and bond strength values were 30.9 +/- 1.1, 28.6 +/- 0.7 mm and 6.3 +/- 5.3, 17.8 +/- 7.5 MPa for Epiphany and AH Plus, respectively (P < 0.001). Failure mode was predominantly cohesive in the sealer for both materials. CONCLUSIONS: Epiphany had higher flow and polymerization stress and lower bond strength values to dentine than AH Plus. In view of these findings it can be implied that AH Plus would provide a better seal.


Assuntos
Colagem Dentária , Dentina/ultraestrutura , Cimentos de Resina/química , Materiais Restauradores do Canal Radicular/química , Análise do Estresse Dentário/instrumentação , Resinas Epóxi/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Polímeros/química , Reologia , Estresse Mecânico , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA